High–power density electric motor designs are a requirement in aerospace and automotive applications. Outer rotor permanent magnet motors can offer high power density but have mechanical challenges such as structural stability and rotodynamic issues. In this work, a rotodynamic study was performed for two outer rotor permanent magnet motor designs. The first design was a cantilever design in which the rotor was suspended at one end, supported by four bearings; in the second design, the rotor was simply supported by two bearings in each end. Two different finite element method–based approaches, solid rotor and beam rotor methods, were used to extract the critical speed.
Transmission and distribution (T&D) dynamic co-simulation is a practical and effective approach to leverage existing simulation tools for transmission and distribution systems to simulate dynamic stability and performance of T&D systems in a systematic manner. Given that these tools are developed as stand-alone programs and there are inherent differences between them, interface techniques become critical to “bridge” them. Two important unsolved questions are: 1) which interface technique is better and should be used, and 2) how the modeling and simulation capabilities in these tools that are available and can be exploited for co-simulation should be considered when selecting an interface technique. This paper presents a comprehensive study for different interface techniques that can be employed for T&D dynamic co-simulation. The study provided insights to the pros and cons of each interface technique, and helped researchers make informed decisions on choosing a proper interface technique.
Abstract not provided
Abstract not provided
The primary objective of this research work is two-fold: (i) determine the degradation rates of Siemens-Arco M55 modules exposed over 18 and 28 years in a hot-dry climate of Arizona and a temperate climate of California, and; (ii) identify the potential modes responsible for these degradation losses. The degradation rates were determined based on the I-V data obtained on exposed modules and on the corresponding control modules which were not exposed in the fields. The degradation modes responsible for these degradations were determined using several nondestructive tests and destructive tests performed on these control and exposed modules. The nondestructive tests included: current-voltage, visual inspection, cell-module quantum efficiency, and module level reflectance spectroscopy. The destructive tests included: transmittance spectroscopy of glass superstrates, and FTIR, DSC and TGA of encapsulant materials.
This study provides an overview of the magnetic field measurement and subsequent electromagnetic re-modeling of the CLAS12 torus during the commissioning of the magnet in the fall of 2016. The CLAS12 detector in Hall B is part of the 12 GeV Accelerator Upgrade project at Jefferson Lab. The torus magnet allows precise determination of particle momenta in the forward direction (~ 5 0 x 4 0 ) in the forward direction. The ability to do this requires we know the fB.dl of the torus to within an accuracy of 0.5 % or better. To achieve this, an accurate model of the field along the particle paths is required. The TOSCA code is used to generate a full 3D simulation of the magnetic envelope of the magnet as designed. Experimentally the actual magnetic field within the magnet was surveyed to confirm the model design and to measure the deviation from the ideal case. The magnetic field deviations are attributed to manufacturing variability and assembly tolerances. A final model was created with allowances for these deviations guided by the survey data to create a more precise field integral model which greatly improves momentum resolution capability allowing it to deliver the required specifications.
Abstract not provided.
Not provided.
Abstract The formation of Ce 2 O 3 from cerium metal requires complex reducing conditions. Alternatively, we show that different stoichiometries and structures of cerium oxides can be generated in high‐temperature laser experiments by varying the availability of oxygen and the use of either pulsed laser ablation (PLA) or continuous wave (CW) laser heating of cerium metal. X‐ray diffraction and Raman spectroscopy suggest that a low structural order Ce 2 O 3 /CeO 2 mixed structure is formed in a 1% O 2 atmosphere with PLA. For CW heating in a 1% O 2 environment, Raman measurements show the formation of crystalline A‐type Ce 2 O 3 in proximity to the point of laser impingement. These experiments were repeated in 18 O 2 and allowed us to report for the first time the corresponding Raman spectrum of Ce 2 18 O 3 .
Alkali vapor corrosion is critical for refractories used in the kilns and furnaces of diverse high-temperature processing and manufacturing sectors such as gasifiers, cement production, and glass making. Gahnite (ZnAl 2 O 4 ) is being investigated as a potential chrome-free refractory because of its similarity with the structure and properties of magnesium aluminate (MgAl 2 O 4 ) spinel. The alkali vapor corrosion of ZnAl 2 O 4 , MgAl 2 O 4 , and Mg 0.5 Zn 0.5 Al 2 O 4 was studied, according to ASTM C987-10, at 1371°C for 24 h using sodium carbonate (Na 2 CO 3 ). The surface and the polished cross-sections of the corroded ZnAl 2 O 4 , MgAl 2 O 4 , and Mg 0.5 Zn 0.5 Al 2 O 4 specimens were analyzed using x-ray diffraction (XRD), microscopy, and energy-dispersive spectroscopy (EDS) techniques. MgO in MgAl 2 O 4 , ZnO in ZnAl 2 O 4 , Mg 0.77 Zn 0.23 O, and NaAlO 2 were detected as the corrosion products for these specimens. The extent of corrosion substantially varied among the specimens despite the similarity in the corrosion products. The corrosion resistance increased in the following order: Mg 0.5 Zn 0.5 Al 2 O 4 > MgAl 2 O 4 > ZnAl 2 O 4 . The formation of a dense MgO and Mg 0.77 Zn 0.23 O layer for MgAl 2 O 4 and Mg 0.5 Zn 0.5 Al 2 O 4 , respectively, contributed to their superior resistance to alkali vapor corrosion. The underlying corrosion mechanisms are discussed based on experimental observations supported by thermodynamic analysis. Additionally, the results suggest that a partial Zn 2+ substitution for Mg 2+ in MgAl 2 O 4 can enhance the resistance to alkali vapor corrosion.
The very thin native oxide film on stainless steel, of the order of 2 nm, is known to be readily modified by immersion in aqueous media. In this paper, X-ray photoelectron spectroscopy (XPS) and time of flight secondary ions mass spectrometry are employed to investigate the nature of the air-formed film and modification after water emersion. The film is described in terms of oxide, hydroxide, and water content. The preferential dissolution of iron is shown to occur on immersion. It is shown that a water absorbed layer and a hydroxide layer are present above the oxide-like passive film. The concentrations of water and hydroxide appear to be higher in the case of exposure to water. A secure method for the peak fitting of Fe2p and Cr2p XPS spectra of such films on their metallic substrates is described. The importance of XPS survey spectra is underlined and the feasibility of C{sub 60}{sup +} SIMS depth profiling of a thin oxide layer is shown.