Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Abundances of Planetary Nebula NGC 5315

The ISO and IUE spectra of the elliptical nebula NGC 5315 is presented. These spectra axe combined with the spectra in the visual wavelength region to obtain a complete, extinction corrected, spectrum. The chemical composition of the nebulae is then calculated and compared to previous determinations. The HST Nicmos observations of the nebula in 3 emission lines are also presented. These observations are used to determine the helium abundance as a function of position in the nebula. A discussion is given of possible evolutionary effects.

Pottasch, S. R.↗

Experimental Verification Of The Osculating Cones Method For Two Waverider Forebodies At Mach 4 and 6

The NASA Langley Research Center Unitary Plan Wind Tunnel and the 20-Inch Mach 6 Tunnel were used to test two osculating cones waverider models. The Mach-4 and Mach-6 shapes were generated using the interactive design tool WIPAR. WIPAR performance predictions are compared to the experimental results. Vapor screen results for the Mach-4 model at the on- design Mach number provide visual verification that the shock is attached along the entire leading edge, within the limits of observation. WIPAR predictions of pressure distributions and aerodynamic coefficients show general agreement with the corresponding experimental values.

Miller, Rolf W.↗

Quantitative image analysis of laminin immunoreactivity in skin basement membrane irradiated with 1 GeV/nucleon iron particles

We previously reported that laminin immunoreactivity in mouse mammary epithelium is altered shortly after whole-body irradiation with 0.8 Gy from 600 MeV/nucleon iron ions but is unaffected after exposure to sparsely ionizing radiation. This observation led us to propose that the effect could be due to protein damage from the high ionization density of the ion tracks. If so, we predicted that it would be evident soon after radiation exposure in basement membranes of other tissues and would depend on ion fluence. To test this hypothesis, we used immunofluorescence, confocal laser scanning microscopy, and image segmentation techniques to quantify changes in the basement membrane of mouse skin epidermis. At 1 h after exposure to 1 GeV/nucleon iron ions with doses from 0.03 to 1.6 Gy, neither the visual appearance nor the mean pixel intensity of laminin in the basement membrane of mouse dorsal skin epidermis was altered compared to sham-irradiated tissue. This result does not support the hypothesis that particle traversal directly affects laminin protein integrity. However, the mean pixel intensity of laminin immunoreactivity was significantly decreased in epidermal basement membrane at 48 and 96 h after exposure to 0.8 Gy 1 GeV/nucleon iron ions. We confirmed this effect with two additional antibodies raised against affinity-purified laminin 1 and the E3 fragment of the long-arm of laminin 1. In contrast, collagen type IV, another component of the basement membrane, was unaffected. Our studies demonstrate quantitatively that densely ionizing radiation elicits changes in skin microenvironments distinct from those induced by sparsely ionizing radiation. Such effects may might contribute to the carcinogenic potential of densely ionizing radiation by altering cellular signaling cascades mediated by cell-extracellular matrix interactions.

Non-NASA Center↗

Crew Health and Performance Improvements with Reduced Carbon Dioxide Levels and the Resource Impact to Accomplish Those Reductions

Carbon dioxide (CO2) removal is one of the primary functions of the International Space Station (ISS) atmosphere revitalization systems. Primary CO2 removal is via the ISS s two Carbon Dioxide Removal Assemblies (CDRAs) and the Russian carbon dioxide removal assembly (Vozdukh); both of these systems are regenerable, meaning that their CO2 removal capacity theoretically remains constant as long as the system is operating. Contingency CO2 removal capability is provided by lithium hydroxide (LiOH) canisters, which are consumable, meaning that their CO2 removal capability disappears once the resource is used. With the advent of 6 crew ISS operations, experience showing that CDRA failures are not uncommon, and anecdotal association of crew symptoms with CO2 values just above 4 mmHg, the question arises: How much lower do we keep CO2 levels to minimize the risk to crew health and performance, and what will the operational cost to the CDRAs be to do it? The primary crew health concerns center on the interaction of increased intracranial pressure from fluid shifts and the increased intracranial blood flow induced by CO2. Typical acute symptoms include headache, minor visual disturbances, and subtle behavioral changes. The historical database of CO2 exposures since the beginning of ISS operations has been compared to the incidence of crew symptoms reported in private medical conferences. We have used this database in an attempt to establish an association between the CO2 levels and the risk of crew symptoms. This comparison will answer the question of the level needed to protect the crew from acute effects. As for the second part of the question, operation of the ISS s regenerable CO2 removal capability reduces the limited life of constituent parts. It also consumes limited electrical power and thermal control resources. Operation of consumable CO2 removal capability (LiOH) uses finite consumable materials, which must be replenished in the long term. Therefore, increased CO2 removal means increased resource use, with increased logistical capability to maintain necessary resources on board ISS. We must strike a balance between sufficiently low CO2 levels to maintain crew health and CO2 levels which are operationally feasible for the ISS program

James, John T.↗

Effects of Motion Cues on the Training of Multi-Axis Manual Control Skills

The study described in this paper investigated the effects of two different hexapod motion configurations on the training and transfer of training of a simultaneous roll and pitch control task. Pilots were divided between two groups which trained either under a baseline hexapod motion condition, with motion typically provided by current training simulators, or an optimized hexapod motion condition, with increased fidelity of the motion cues most relevant for the task. All pilots transferred to the same full-motion condition, representing motion experienced in flight. A cybernetic approach was used that gave insights into the development of pilots use of visual and motion cues over the course of training and after transfer. Based on the current results, neither of the hexapod motion conditions can unambiguously be chosen as providing the best motion for training and transfer of training of the used multi-axis control task. However, the optimized hexapod motion condition did allow pilots to generate less visual lead, control with higher gains, and have better disturbance-rejection performance at the end of the training session compared to the baseline hexapod motion condition. Significant adaptations in control behavior still occurred in the transfer phase under the full-motion condition for both groups. Pilots behaved less linearly compared to previous single-axis control-task experiments; however, this did not result in smaller motion or learning effects. Motion and learning effects were more pronounced in pitch compared to roll. Finally, valuable lessons were learned that allow us to improve the adopted approach for future transfer-of-training studies.

flight simulators↗

Noise Reduction and Calibration for Aeroacoustic Loads from Unsteady Pressure-Sensitive Paint

Unsteady pressure-sensitive paint (uPSP) is a significant new technology for high spatial resolution measurement of complex dynamic surface pressure loading on a wind tunnel model, to better define flight vehicle buffet and aeroacoustic loads. Compared with the very sparse surface pressure measurements of traditional sensors, the pressure sensitivity of uPSP light reflectivity provides a visual measure of surface pressure fluctuations over a wide area illuminated by high intensity light, captured by a high-speed digital camera. Panda et al (AIAA Journal, May 2019) have shown good data is recoverable up to 10 kHz. In cases where available uPSP luminescence is low for a painted wind tunnel test model, significant noise levels have been observed primarily due to the discrete photon arrival variability of low intensity light (termed “shot noise”). In this case, uPSP measurements can exhibit unusually low signal to noise ratio (SNR of 0.1 or less). This paper will report on latest work to recover calibrated uPSP measurements which are noise free over a useful dynamic range of 10-15 dB. It will be shown how the distinct spatial correlations of both the shot noise and the underlying aeroacoustic surface pressure play an important role in obtaining a reliable measurement.

pressure-sensitive paint↗

Current State of NASA Continuously Rotating Detonation Cycle Engine Development

NASA is currently investigating continuous detonation cycle engines for the application of lander and interplanetary space exploration missions. The performance benefits of a detonation cycle engine may allow for a broader design trade space and more compact geometry required for future missions to the Moon and onwards towards Mars. However, the technology readiness level (TRL) within the US was found to be low with several major risk factors that require understanding prior to full engine system development. One area of uncertainty is the extreme heat loads expected during thermal steady state conditions. To achieve this, an announcement for collaborative opportunity (ACO) partnership between IN Space LLC and NASA Marshall Space Flight Center (MSFC) was established to explore integration of additive manufacturing (AM) processes and the high conductance copper-based alloys, GRCop-42 and GRCop-84. This work outlines the hot fire testing of a 7K lbf thrust class fully AM GRCop-alloy rotating detonation rocket engine (RDRE). Two annular thrust chamber configurations emulating a lander engine system were tested with LOx/GH2 and LOx/LCH4. In both configurations, select hardware was actively cooled using de-ionized water and regeneratively cooled using LCH4. All primary hardware survived long duration tests to thermal steady state up to 133 seconds in a single burn. In total, 18 starts and 802 seconds of duration were achieved with and without visual confirmation of waves present. The proportion of burned propellant, or level of complete combustion, was found to be high compared to the theoretically achievable mean chamber pressure in all cases.

Thomas Teasley↗

Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station

Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. cones ) of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of Maximum Eye Movement. However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of Easy Eye Movement, though all were within the cone of Maximum Eye Movement. All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Most instrument displays in conventional aircraft lay within the cone of Easy Eye Movement, though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight. The learning objectives include: 1) Know three physiologic cones of eye/head movement; 2) Understand how instrument displays comply with these design principles in conventional aircraft and an uninhabited aerial vehicle system. Which of the following is NOT a recognized physiologic principle of instrument display design? Cone of Easy Eye Movement 2) Cone of Binocular Eye Movement 3) Cone of Maximum Eye Movement 4) Cone of Head Movement 5) None of the above. Answer: # 2) Cone of Binocular Eye Movement

Kamine, Tovy Haber↗

NASA Radiation Track Image GUI for Assessing Space Radiation Biological Effects

The high-charge high-energy (HZE) ion components of the galactic cosmic rays when compared to terrestrial forms of radiations present unique challenges to biological systems. In this paper we present a deoxyribonucleic acid (DNA) breakage model to visualize and analyze the impact of chromatin domains and DNA loops on clustering of DNA damage from X rays, protons, and HZE ions. Our model of DNA breakage is based on a stochastic process of DNA double-strand break (DSB) formulation that includes the amorphous model of the radiation track and a polymer model of DNA packed in the cell nucleus. Our model is a Monte-Carlo simulation based on a randomly located DSB cluster formulation that accomodates both high- and low-linear energy transfer radiations. We demonstrate that HZE ions have a strong impact on DSB clustering, both along the chromosome length and in the nucleus volume. The effects of chromosomal domains and DNA loops on the DSB fragment-size distribution and the spatial distribution of DSB in the nucleus were studied. We compare our model predictions with the spatial distribution of DSB obtained from experiments. The implications of our model predictions for radiation protection are discussed.

Ponomarev, Artem L.↗

Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station

Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. "cones") of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement" (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Methods: Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. Results: The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of "Maximum Eye Movement". However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of "Easy Eye Movement", though all were within the cone of "Maximum Eye Movement". All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Discussion: Most instrument displays in conventional aircraft lay within the cone of "Easy Eye Movement", though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight.

Bendrick, Gregg A.↗

The use of spatial characteristics for the improvement of multispectral classification of remotely sensed data

Two techniques for the classification of multispectral remotely sensed data - the image processing technique of texture features, which is modeled after the human visual system, and the ECHO (Extraction and Classification of Homogeneous Objects) numerical technique - are examined. These two spatial analysis techniques are compared using Landsat imagery of an area of Indiana as an example, and it is found that the numerical approach is superior in classification accuracy and more efficient computationally.

Wiersma, D. J.↗

Investigations of eddy coherence in jet flows

In turbulent shear flow the term coherent structures refers to eddies which are both spatially coherent, i.e., large eddies, aand also temporally coherent, i.e., they retain their identities for times which are long compared with their time scales in fixed point measurements. In transitional flows, the existence of such structures is evident from flow visualizations. In many other flows, such structures are not so evident. The reasons for the existence of these two classes of flows are discussed and attention is focused upon the more difficult flows, where coherent structures are not so evident. Techniques by which the existence (or nonexistence) of such structures in these flows can be established from point measurements, are also discussed. A major problem is shown to be the need to discriminate between real losses in eddy coherence and apparent losses in coherence introduced by phase scrambling effects which 'smear' multipoint correlations. The analysis of multiprobe time dependent data in cold and reacting round turbulent jets is described and it is shown how evidence of strong eddy coherence can be extracted from data.

Yule, A. J.↗

Optical polarization of the Seyfert galaxies IC 4329A and MRK 376

Measurements of the optical polarizations of the two highly polarized Seyfert 1 galaxies IC 4329A and Mrk 376 are presented. Continuum and line polarization of the two objects were observed with the Steward Observatory 2.25-m telescope using a two-channel photoelectric Pockels cell polarimeter, a single-channel scanner, and a digicon attached to a flint prism spectrograph. Results indicate that, for both galaxies, the emission line polarization and underlying continuum polarization are identical, rising toward short wavelengths, and therefore must be explained by a common mechanism. Such a mechanism is suggested to involve polarization produced by aligned grains in the galactic disk. A model for polarization in IC 4329A by this mechanism predicts a grain size three times smaller than Galactic polarizing grains, as well as a visual extinction of about 2 magnitudes, a gas to dust mass ratio close to 100 and a polarization to extinction ratio comparable to the Galactic ratio.

Martin, P. G.↗

Interpretation of remotely sensed data and its applications in oceanography

The methodology of interpretation of remote sensing data and its oceanographic applications are described. The elements of image interpretation for different types of sensors are discussed. The sensors utilized are the multispectral scanner of LANDSAT, and the thermal infrared of NOAA and geostationary satellites. Visual and automatic data interpretation in studies of pollution, the Brazil current system, and upwelling along the southeastern Brazilian coast are compared.

Parada, N. D. J.↗

Comparison of simulator fidelity model predictions with in-simulator evaluation data

A full factorial in simulator experiment of a single axis, multiloop, compensatory pitch tracking task is described. The experiment was conducted to provide data to validate extensions to an analytic, closed loop model of a real time digital simulation facility. The results of the experiment encompassing various simulation fidelity factors, such as visual delay, digital integration algorithms, computer iteration rates, control loading bandwidths and proprioceptive cues, and g-seat kinesthetic cues, are compared with predictions obtained from the analytic model incorporating an optimal control model of the human pilot. The in-simulator results demonstrate more sensitivity to the g-seat and to the control loader conditions than were predicted by the model. However, the model predictions are generally upheld, although the predicted magnitudes of the states and of the error terms are sometimes off considerably. Of particular concern is the large sensitivity difference for one control loader condition, as well as the model/in-simulator mismatch in the magnitude of the plant states when the other states match.

Parrish, R. V.↗

A study of multi-body aerodynamic interference at transonic Mach numbers

A wind tunnel experiment involving single, double, and triple combinations of mutually interfering generic, unfinned aircraft stores has been conducted. Each combination of stores was tested at Mach numbers from 0.60 to 1.20 and at angles of attack from 0 to 25 deg for the single store and from 0 to 6 deg for the double and triple store configurations. Extensive axial and circumferential pressure and flow visualization data at each store location were obtained. Euler solutions for each configuration at 0 deg incidence have been generated and compared with experimental data. This comparison indicates an Euler flow solver can yield accurate predictions of the location and magnitude of multibody interference provided an appropriate grid is used and the viscous effects associated with these configurations remain small. The data indicate multibody interference in the transonic region increases as the freestream Mach number approaches 1 from either direction, and subsides as the Mach number moves away from sonic conditions. This interference is characterized by a large, localized reduction in pressure on the inboard surfaces of the bodies which results in forces that draw the configuration closer together.

Cottrell, Charles J.↗

Thermocapillary migration of liquid droplets in a temperature gradient in a density matched system

An experimental investigation of thermocapillary flow in droplets of a vegetable oil (partially hydrogenated soybean oil) immersed in silicone oil was conducted in a test cell with a heated top wall and a cooled bottom wall. The liquids are nearly immiscible and have equal densities at a temperature below the room temperature, thus providing a simulation of low-gravity conditions by reducing the buoyancy forces. The interfacial tension between the two oils was measured in the temperature range 20 to 50 C using a capillary tube and (d sigma)/(d T) was determined to be negative. Droplets ranging in sizes from 3 mm to 1 cm diameter were injected into the silicone oil. The vertical temperature profile in the bulk liquid (silicone oil) produces temperature variations along the interface which induce variations in the interfacial tension. The flow inside the droplet driven by the resulting interfacial shear stresses was observed using a laser light-sheet flow visualization technique. The flow direction is consistent with the sign of (d sigma)/(d T). The observed maximum surface velocities are compared to the theoretical predictions of Young et al. (1959).

Rashidnia, N.↗

Thermocapillary migration of liquid droplets in a temperature gradient in a density matched system

An experimental investigation of thermocapillary flow in droplets of a vegetable oil (partially hydrogenated soybean oil) immersed in silicone oil was conducted in a test cell with a heated top wall and a cooled bottom wall. The liquids are nearly immiscible and have equal densities at a temperature below the room temperature, thus providing a simulation of low-gravity conditions by reducing the buoyancy forces. The interfacial tension between the two oils was measured in the temperature range 20 to 50 C using a capillary tube and (d sigma)/(d T) was determined to be negative. Droplets ranging in sizes from 3 mm to 1 cm diameter were injected into the silicone oil. The vertical temperature profile in the bulk liquid (silicone oil) produces temperature variations along the interface which induce variations in the interfacial tension. The flow inside the droplet driven by the resulting interfacial shear stresses was observed using a laser light-sheet flow visualization technique. The flow direction is consistent with the sign of (d sigma)/(d T). The observed maximum surface velocities are compared to the theoretical predictions of Young et al. (1959).

Rashidnia, N.↗