Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Impact of regadenoson-induced myocardial creep on dynamic Rubidium-82 PET myocardial blood flow quantification

Background: Repositioning of the heart during myocardial perfusion imaging (MPI) using Rubidium-82 (Rb-82) PET may occur when using regadenoson. Our aim was to determine the prevalence and the effect of correcting for this myocardial creep on myocardial blood flow (MBF) quantification. Methods: We retrospectively included 119 consecutive patients who underwent dynamic rest- and regadenoson-induced stress MPI using Rb-82 PET. The presence of myocardial creep was visually assessed in the dynamic stress PET series by identifying differences between the automatically drawn myocardium contour and the activity. Uncorrected and corrected stress MBFs were compared for the three vascular territories (LAD, LCX, and RCA) and for the whole myocardium. Results: Myocardial creep was observed in 52% of the patients during stress. Mean MBF values decreased after correction in the RCA from 4.0 to 2.7 mL/min/g (P < 0.001), in the whole myocardium from 2.7 to 2.6 mL/min/g (P = 0.01), and increased in the LAD from 2.5 to 2.6 mL/min/g (P = 0.03) and remained comparable in the LCX (P = 0.3). Conclusions: Myocardial creep is a frequent phenomenon when performing regadenoson-induced stress Rb-82 PET and has a significant impact on MBF values, especially in the RCA territory. As this may hamper diagnostic accuracy, myocardial creep correction seems necessary for reliable quantification. [French] French Abstract: Contexte: Un repositionnement du cœur lors de l’imagerie de perfusion myocardique (MPI) à l’aide de la TEP au rubidium-82 (RB-82) peut survenir lors de l’utilisation du regadenoson. Notre objectif était de déterminer la prévalence et l’effet de la correction du fluage sur la quantification du débit sanguin myocardique (DSM). Méthodes: dans cette étude rétrospective, nous avons inclus 119 patients consécutifs ayant beneficié d’un examen au repos suivi d’un stress pharamacologique au régadénoson en utilisant le RB-82. La présence de fluage myocardique a été évaluée visuellement sur les images TEP de stress dynamique en utilisant les différences entre les contours automatiques et les images myocardiques. Les DSM de stress non corrigés et corrigés ont été comparés pour les trois territoires vasculaires (coronaire gauche-CG, la circonflexe-CX, et coronaire droite-CD) et pour l’ensemble du myocarde. Résultats: le fluage myocardique a été observé chez 52% des patients sur les examens de stress. Les valeurs moyennes de DSM ont diminué après correction dans le territoire de la CD de 4,0 à 2,7 mL/min/g (p < 0,001), dans le myocarde entier de 2,7 à 2,6 mL/min/g (p = 0,01) et augmenté dans le territoire de la CG de 2,5 à 2,6 mL/min/g (p = 0,03) et est resté comparable dans le territoire de la CX (p = 0,3). Conclusions: le fluage myocardique est un phénomène fréquent lors de l’exécution du stress phramacologique au régadénoson à l’aide du RB-82. Il a un impact significatif sur les valeurs de DSM, en particulier dans le territoire de la CD. La correction du fluage myocardique semble donc nécessaire pour une quantification fiable des flux coronariens. [Spanish] Spanish Abstract: Antecedentes: El movimiento del corazón durante la imagen de perfusión miocárdica usando Rubidio-82 (Rb-82) PET puede ocurrir cuando se usa regadenosón. Nuestro enfoque fue determinar la prevalencia y efecto de la corrección de este Artefacto de movimiento en la cuantificación del flujo sanguíneo miocárdico. Métodos: Se incluyeron de forma retrospectiva 119 pacientes que se realizaron estudio dinámico en reposo y estudio de perfusión miocárdica en estrés inducido por regadenosón usando Rb-82 PET. La presencia de el artefacto de movimiento fue evaluado visualmente en el estudio en serie de PET dinámico en estrés identificando las diferencias entre el contorno miocárdico dibujado automáticamente y la actividad. La perfusión miocárdica en estrés corregida y sin corregir se compararon para los tres territorios vasculares (Descendente Anterior, Circunfleja, Coronaria Derecha) y para todo el miocardio. Resultados: El artefacto de movimiento miocárdico se observo en un 52% de los pacientes durante el estrés. El promedio de los valores de flujo sanguíneo miocárdico disminuyen después de la corrección en la arteria coronaria derecha de 4.0 a 2.7 ml/min/g (p < 0.001), en todo el miocardio de 2.7 a 2.6 mL/min/g (p = 0.01) y un aumento en la arteria descendente anterior de 2.5 a 2.6 mL/min/g (p = 0.03) y se mantuvo comparable en la arteria circunfleja (p = 0.3). Conclusiones: El artefacto de movimiento miocárdico es un fenómeno frecuente cuando se realiza la prueba de estrés inducido con regadenosón Rb-82 PET y tiene un impacto significativo en los valores de flujo sanguíneo miocárdico, principalmente en el territorio de la coronaria derecha. Esto puede disminuir la precisión diagnostica, la corección del artefacto de movimiento es necesario para una cuantificación confiable. [Chinese] Chinese Abstract: 背景: 铷-82 (Rb-82) PET心肌灌注成像 (MPI) 过程在使用类伽腺苷时可能会发生心脏重定位。我们的目的是确定心肌蠕动 (myocardial creep) 校正对心肌血流灌注定量的影响及其普遍性。 方法: 我们连续回顾了119 名使用 Rb-82 PET 进行动态的静息与类伽腺苷负荷MPI的患者。通过识别自动绘制的心肌轮廓和心肌活动之间的差异, 在动态负荷 PET 检查中肉眼评估心肌蠕动的存在。分别在已校正和未校正的负荷 MBF上, 对三个血管区域 (LAD, LCX, RCA) 和整个心肌灌注情况进行比较。 结果: 负荷检查中, 52% 的患者观察到心肌蠕动。 RCA 校正后平均MBF值从4.0降至 2.7 mL / min / g (p <0.001), 整个心肌从 2.7降至 2.6 mL / min / g (p = 0.01) , LAD 从 2.5 升至 2.6mL / min / g (p = 0.03) 并且在LCX中保持不变 (p = 0.3) 。 结论: 类伽腺苷负荷 Rb-82 PET 检查中, 心肌蠕动是一种常见的现象, 并且对 MBF 值有显著影响, 特别在 RCA 区域。这可能妨碍诊断准确性, 因此心肌蠕动校正是准确定量的必要条件。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anisotropy effects on the kinetics of colloidal crystallization and melting: comparison of spheres and ellipsoids

We use alternating current (AC) electric field assisted self-assembly to produce two-dimensional, millimeter scale arrays of ellipsoidal colloids and study the kinetics of their phase reconfiguration by means of confocal microscopy, light scattering, and computer simulation. We find that the kinetics of orientational and positional ordering can be manipulated by changing the shape of the colloids: ellipsoids with aspect ratio 2.0 melt into disordered structures 5.7 times faster compared to spheres. On the other hand, ellipsoids self-assemble into ordered crystals at a similar rate to spheres. Confocal microscopy is used to directly visualize defects in the self-assembled structures. Small-angle light scattering (SALS) quantifies the light diffraction response, which is sensitive to the kinetics of positional and orientational ordering in the self-assembled anisotropic structures. We find three different light diffraction patterns: a phase with high orientational order (with chain-like structure in real space), a phase with high positional and orientational order (characteristic of a close-packed structure), and a phase that is disordered in position but with intermediate orientational order. The large influence of aspect ratio on the kinetics of the positionally and orientationally ordered phase is explored through simulation; it is found that the number of particle degrees of freedom controls the difference between the melting rates of the ellipsoids and spheres. This research contributes to the understanding of reconfiguration kinetics and optical properties of colloidal crystals produced from anisotropic colloids.

36 MATERIALS SCIENCE↗

A WFC3 GRISM emission line Redshift catalog in the Goods-South Field

We combine Hubble Space Telescope (HST)/Wide Field Camera3 (WFC3) imaging and G141 grism observations from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) and 3D-HST surveys to produce a catalog of grism spectroscopic redshifts for galaxies in the CANDELS/GOODS-South field. The WFC3/G141 grism spectra cover a wavelength range of 1.1⩽λ⩽1.7 μm with a resolving power of R∼130 for point sources, thus providing rest-frame optical spectra for galaxies out to z∼3.5. The catalog is selected in the H-band (F160W) and includes both galaxies with and without previously published spectroscopic redshifts. Grism spectra are extracted for all H-band detected galaxies with H ⩽ 24 and a CANDELS photometric redshift z{sub phot}⩾0.6. The resulting spectra are visually inspected to identify emission lines, and redshifts are determined using cross-correlation with empirical spectral templates. To establish the accuracy of our redshifts, we compare our results against high-quality spectroscopic redshifts from the literature. Using a sample of 411 control galaxies, this analysis yields a precision of σ{sub NMAD}=0.0028 for the grism-derived redshifts, which is consistent with the accuracy reported by the 3D-HST team. Our final catalog covers an area of 153 arcmin{sup 2} and contains 1019 redshifts for galaxies in GOODS-S. Roughly 60% (608/1019) of these redshifts are for galaxies with no previously published spectroscopic redshift. These new redshifts span a range of 0.677⩽z⩽3.456 and have a median redshift of z = 1.282. The catalog contains a total of 234 new redshifts for galaxies at z>1.5. In addition, we present 20 galaxy pair candidates identified for the first time using the grism redshifts in our catalog, including four new galaxy pairs at z∼2, nearly doubling the number of such pairs previously identified.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and evaluation of a method of calibrating medical displays based on fixed adaptation

Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrast levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.

60 APPLIED LIFE SCIENCES↗

TU-G-BRA-03: Predicting Radiation Therapy Induced Ventilation Changes Using 4DCT Jacobian Calculations

Purpose: Longitudinal changes in lung ventilation following radiation therapy can be mapped using four-dimensional computed tomography(4DCT) and image registration. This study aimed to predict ventilation changes caused by radiation therapy(RT) as a function of pre-RT ventilation and delivered dose. Methods: 4DCT images were acquired before and 3 months after radiation therapy for 13 subjects. Jacobian ventilation maps were calculated from the 4DCT images, warped to a common coordinate system, and a Jacobian ratio map was computed voxel-by-voxel as the ratio of post-RT to pre-RT Jacobian calculations. A leave-one-out method was used to build a response model for each subject: post-RT to pre-RT Jacobian ratio data and dose distributions of 12 subjects were applied to the subject’s pre-RT Jacobian map to predict the post-RT Jacobian. The predicted Jacobian map was compared to the actual post-RT Jacobian map to evaluate efficacy. Within this cohort, 8 subjects had repeat pre-RT scans that were compared as a reference for no ventilation change. Maps were compared using gamma pass rate criteria of 2mm distance-to-agreement and 6% ventilation difference. Gamma pass rates were compared using paired t-tests to determine significant differences. Further analysis masked non-radiation induced changes by excluding voxels below specified dose thresholds. Results: Visual inspection demonstrates the predicted post-RT ventilation map is similar to the actual map in magnitude and distribution. Quantitatively, the percentage of voxels in agreement when excluding voxels receiving below specified doses are: 74%/20Gy, 73%/10Gy, 73%/5Gy, and 71%/0Gy. By comparison, repeat scans produced 73% of voxels within the 6%/2mm criteria. The agreement of the actual post-RT maps with the predicted maps was significantly better than agreement with pre-RT maps (p<0.02). Conclusion: This work validates that significant changes to ventilation post-RT can be predicted. The differences between the predicted and actual outcome are similar to differences between repeat scans with equivalent ventilation. This work was supported by NIH grant CA166703 and a Pilot Grant from University of Iowa Carver College of Medicine.

60 APPLIED LIFE SCIENCES↗

ML-based Dimension Reduction Strategies

Deep learning (DL)--based surrogate models have achieved success in various applications in carbon capture and storage (CCS). However, the model training on high-dimensional spaces is computationally expensive and impractical for large-scale and complex geological models, because the models usually contain hundreds of thousands to millions of grid cells, each with a set of parameters. Furthermore, the high cost of generating training data with sufficient variation is another limitation of model training on high-dimensional spaces, which may result in overfitting and reduce the model efficiency and prediction performance. We proposed the workflow incorporating dimension reduction methods and deep learning models, which aim to extract the latent variables of input parameters and output state variables, and then build the mapping function at the latent spaces. The proposed workflow can significantly reduce the computational complexity in solving both forward and inverse problems compared to models trained on high-dimensional spaces. Dimensionality reduction models showed great potential in workflows for fast reservoir simulation, history matching, prior model generation, visualization, and more, ultimately enhancing DL model performance in related SMART Work Packages.

Hosseini, Seyyed↗

Upgrading Linear Fluorescent Fixtures to LED in Schools

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. Light-emitting diode or LED lighting fixtures have gained traction in common commercial building applications and quality replacement options for common fixture types are widely available. Compared to most fluorescent lighting systems, using LEDs can reduce energy consumption and therefore decrease carbon dioxide emissions, reduce maintenance and operation cost, and improve the visual appearance and lighting quality of the classroom and school environments. When additional controls are considered, more energy can be saved and some controls, like dimming, can offer amenities to occupants. As LEDs become an even more prominent lighting technology, fluorescent equipment may become challenging or expensive to replace. Additionally, school buildings are typically in use for many decades; maintaining a long-term view can be important when deciding which upgrade path to take. This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for fluorescent lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracing Interstellar Magnetic Field Using Velocity Gradient Technique: Application to Atomic Hydrogen Data

The advancement of our understanding of MHD turbulence opens ways to develop new techniques to probe magnetic fields. In MHD turbulence, the velocity gradients are expected to be perpendicular to magnetic fields and this fact was used by González-Casanova and Lazarian to introduce a new technique to trace magnetic fields using velocity centroid gradients (VCGs). The latter can be obtained from spectroscopic observations. We apply the technique to GALFA-H i survey data and then compare the directions of magnetic fields obtained with our technique to the direction of magnetic fields obtained using PLANCK polarization. We find an excellent correspondence between the two ways of magnetic field tracing, which is obvious via the visual comparison and through the measuring of the statistics of magnetic field fluctuations obtained with the polarization data and our technique. This suggests that the VCGs have a potential for measuring of the foreground magnetic field fluctuations, and thus provide a new way of separating foreground and CMB polarization signals.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-303-03: A Scheme for Real-Time, Marker-Less and Low-Dose Tumor Tracking Using Scattering Imaging: Monte Carlo Simulation Study

Purpose: In-treatment tumor localization is critical for the management of tumor motion in lung cancer radiotherapy. Conventional tumor-tracking methods using a kV or MV x-ray projection has limited contrast. To facilitate real-time, marker-less and low-dose in-treatment image tumor tracking, we propose a novel scheme using Compton scatter imaging. This study reports Monte Carlo (MC) simulations on this scheme for the purpose of proof-of-principle. Methods: A slit x-ray beam along the patient superior-inferior (SI) direction is directed to the patient, intersecting the patient lung at a 2D plane containing majority part of the tumor motion trajectory. X-ray photons are scattered due to Compton effect from this plane, which are spatially collimated by, e.g., a pinhole, on one side of the plane and then captured by a detector behind it. The captured image, after correcting for x-ray attenuation and scatter angle variation, reflects the electron density, which allows visualization of the instantaneous anatomy on this plane. We performed MC studies on a phantom and a patient case for the initial test of this proposed method. Results: In the phantom case, the contrast-resolution calculated using tumor/lung as foreground/background for kV fluoroscopy, cone-beam CT, and scattering image were 0.0625, 0.6993, and 0.5290, respectively. In the patient case, tumor motion can be clearly observed in the scatter images. Compared to fluoroscopy, scattering imaging also significantly reduced imaging dose because of its narrower beam design. Conclusion: MC simulation studies demonstrated the potential of the proposed scheme in terms of capturing the instantaneous anatomy of a patient on a 2D plane. Clear visualization of the tumor will probably facilitate ‘marker-less’ and ‘real-time’ tumor tracking with low imaging dose. NIH (1R01CA154747-01, 1R21CA178787-01A1 and 1R21EB017978-01A1)

60 APPLIED LIFE SCIENCES↗

Different conformational dynamics of β-arrestin1 and β-arrestin2 analyzed by hydrogen/deuterium exchange mass spectrometry

Highlights: • The conformational dynamics of β-arrestin1 or β-arrestin2 were analyzed by HDX-MS. • β-Strands II through IV were more dynamic in β-arrestin2 than in β-arrestin1. • The middle loop was less dynamic in β-arrestin2 than in β-arrestin1. • Upon pre-activation by the R169E mutation, β-arrestins became more dynamic. • Pre-activation affected a wider region of β-arrestin1 compared to β-arrestin2. - Abstract: Arrestins have important roles in G protein-coupled receptor (GPCR) signaling including desensitization of GPCRs and G protein-independent signaling. There have been four arrestins identified: arrestin1, arrestin2 (e.g. β-arrestin1), arrestin3 (e.g. β-arrestin2), and arrestin4. β-Arrestin1 and β-arrestin2 are ubiquitously expressed and regulate a broad range of GPCRs, while arrestin1 and arrestin4 are expressed in the visual system. Although the functions of β-arrestin1 and β-arrestin2 widely overlap, β-arrestin2 has broader receptor selectivity, and a few studies have suggested that β-arrestin1 and β-arrestin2 have distinct cellular functions. Here, we compared the conformational dynamics of β-arrestin1 and β-arrestin2 by hydrogen/deuterium exchange mass spectrometry (HDX-MS). We also used the R169E mutant as a pre-activation model system. HDX-MS data revealed that β-strands II through IV were more dynamic in β-arrestin2 in the basal state, while the middle loop was more dynamic in β-arrestin1. With pre-activation, both β-arrestin1 and β-arrestin2 became more flexible, but broader regions of β-arrestin1 became flexible compared to β-arrestin2. The conformational differences between β-arrestin1 and β-arrestin2 in both the basal and pre-activated states might determine their different receptor selectivities and different cellular functions.

60 APPLIED LIFE SCIENCES↗

Thermodynamics of emergent magnetic charge screening in artificial spin ice

Electric charge screening is a fundamental principle governing the behaviour in a variety of systems in nature. Through reconfiguration of the local environment, the Coulomb attraction between electric charges is decreased, leading, for example, to the creation of polaron states in solids or hydration shells around proteins in water. Here, we directly visualize the real-time creation and decay of screened magnetic charge configurations in a two-dimensional artificial spin ice system, the dipolar dice lattice. By comparing the temperature dependent occurrence of screened and unscreened emergent magnetic charge defects, we determine that screened magnetic charges are indeed a result of local energy reduction and appear as a transient minimum energy state before the system relaxes towards the predicted ground state. These results highlight the important role of emergent magnetic charges in artificial spin ice, giving rise to screened charge excitations and the emergence of exotic low-temperature configurations.

36 MATERIALS SCIENCE↗

Consistent and reproducible computation of the glass transition temperature from molecular dynamics simulations

In many fields, from semiconductors for opto-electronic applications to ionic liquids (ILs) for separations, the glass transition temperature (Tg) of a material is a useful gauge for its potential use in practical settings. As a result, there is a great deal of interest in predicting Tg using molecular simulations. However, the uncertainty and variation in the trend shift method, a common approach in simulations to predict Tg, can be high. This is due to the need for human intervention in defining a fitting range for linear fits of density with temperature assumed for the liquid and glass phases across the simulated cooling. The definition of such fitting ranges then defines the estimate for the Tg as the intersection of linear fits. We eliminate this need for human intervention by leveraging the Shapiro–Wilk normality test and proposing an algorithm to define the fitting ranges and, consequently, Tg. Through this integration, we incorporate into our automated methodology that residuals must be normally distributed around zero for any fit, a requirement that must be met for any regression problem. Consequently, fitting ranges for realizing linear fits for each phase are statistically defined rather than visually inferred, obtaining an estimate for Tg without any human intervention. The method is also capable of finding multiple linear regimes across density vs temperature curves. We compare the predictions of our proposed method across multiple IL and semiconductor molecular dynamics simulation results from the literature and compare other proposed methods for automatically detecting Tg from density–temperature data. We believe that our proposed method would allow for more consistent predictions of Tg. We make this methodology available and open source through GitHub.

Chemistry↗

Leveraging gradient weighted class activation mapping to improve classification effectiveness: Case study in transportation infrastructure characterization

Roadway “corners†are common for pedestrian use, whether designated with markings or not. Different types of markings have been deployed, ranging from simple parallel lines to more complex designs. Understanding the impact of different types of crosswalks is important for public safety. In this work we explore methods to improve the logging of marked crosswalk types. We used the Roadway Information Database from the Second Strategic Highway Research Project and used active learning methods with transfer learning to identify the crosswalk types (marked or unmarked). Upon completion we found our classifiers were unable to perform above roughly 94% correct classifications. To improve their efficacy, we separated the crosswalks into their “fine grained†types and used Gradient-Weighted Class Activation Mapping to isolate and study the features that classified the crosswalks. We compared this with sampled manually marked crosswalks and present findings. We believe this use case can represent a process to improve the active learning method for some visual machine learning applications.

Karnowski, Thomas↗

Subtask 1.1 – Advanced Characterization of Unconventional Oil and Gas Reservoirs to Enhance CO2 Storage Resource Estimates

The Energy & Environmental Research Center (EERC) developed methods and approaches for advanced characterization of unconventional oil and gas reservoirs to enhance CO2 storage resource estimates using samples collected from organic-rich shales of the Bakken Formation. The project was funded under U.S. Department of Energy (DOE) Cooperative Agreement No. DE-FE0024233, with nonfederal cost share provided by Hitachi High Technologies America. The project participants included the EERC, Hitachi High Technologies America, the team at the National Energy Technology Laboratory’s (NETL’s) computed tomography (CT) scanning laboratory in Morgantown, West Virginia, and several NETL staff who have worked on CO2 storage resource estimation. Investigations on the use of subsurface geologic formations for CO2 storage have been ongoing for many years. In the last decade, improvements in directional drilling technology and hydraulic fracturing of organic-rich shale and other tight rock formations have opened new opportunities for CO2 storage, with the potential cobenefit of enhancing gas and oil recovery. Gas-bearing, organic-rich shales have been of particular interest as a carbon storage target because their ability to store large volumes of CO2 is implied by their ability to store methane; however, estimating the CO2 storage resource of organic-rich shales and other unconventional reservoirs is challenging because of the lack of detailed geologic and petrophysical data that are needed to develop improved volumetric equations. According to NETL’s method for estimating regional-scale CO2 storage resources, the key factors that control CO2 storage in geologic formations include void space within induced fractures, natural fractures and matrix pores, as well as the occurrence and distribution of organic matter (OM) and clay minerals. A key goal of this effort was to use field emission scanning electron microscopy (FESEM) analysis of fine-grain unconventional reservoir rocks coupled with advanced image analysis and machine learning techniques to quantify the occurrence and distribution of porosity, OM, and clay minerals. By better understanding the potential migration pathways of CO2 within tight rocks and quantifying the occurrence of sorptive components (OM and clays) along potential flow pathways, methods to estimate the CO2 storage resource of such rocks can be refined. The Bakken petroleum system (Bakken) was used as the source of rock samples for this effort because it includes organic-rich shales with contrasting degrees of thermal maturity as well as tight, nonshale clastic rocks with varying clay mineral content. To better understand the key components of interest in tight rock samples, the EERC worked closely with Hitachi to optimize the FESEM settings necessary to resolve the sample mineralogy, porosity and OM content at micro- to nanoscale resolution. The EERC also worked closely with Hitachi to apply and improve its advanced mineral identification and characterization system (AMICS) software so that it is better suited for mineral identification at the high resolution necessary to resolve features of interest in fine-grained rocks such as organic-rich shales. The EERC also applied advanced image analysis software packages, including Ilastik, to classify and quantify the key components of interest within the samples using FESEM imagery. These advanced techniques allowed for quantification and differentiation of the void space within fractures, pores and OM, as well as a technique to determine and quantify the key mineral and OM components surrounding pore spaces. Being able to better quantify the void space and the potential accessibility of CO2 to sorptive minerals or OM within tight rocks allows for improved estimation of the CO2 storage resource potential of organic-rich shales and other unconventional formations. The information derived from the image analysis techniques was used to refine NETL’s method for estimating regional-scale CO2 storage resources in collaboration with staff from NETL. An additional goal of this work was to better understand rates of CO2 permeation, flow pathways, and sorption in organic-rich shales and nonshale reservoir rocks and to evaluate potential changes in CO2 flow over time. The EERC conducted long-duration (several weeks) CO2 flow-through testing at reservoir conditions using Bakken shale and nonshale samples to assess CO2 permeation rates and retention/sorption within core plugs to represent bulk matrix behavior. Conventional isothermal adsorption testing over a range of pressure conditions was also performed on pulverized Bakken samples to better assess potential maximum sorptive capacity of the samples. The results of this testing illustrated the higher sorptive capacity of the Bakken shales when compared to the sorptive capacity of the nonshale reservoir rock, which contains very little OM when compared to the Bakken shales. The results also illustrate the differences in permeation behavior as a function of fracture flow versus matrix flow. In an attempt to visualize CO2 permeation and flow behavior in Bakken shale samples over time, the EERC collaborated with NETL’s CT Lab in Morgantown, West Virginia. A variety of tests were performed at the NETL lab on unfractured and fractured samples of the Bakken shale. The unfractured Bakken shale samples did not result in CO2 migration within the samples over the testing duration; thus imagery of CO2 migration pathways within the matrix of Bakken samples was not obtained. The results of the flow-through testing within fractured samples illustrate changes in CO2 permeation rates over time, with a trend of decreasing CO2 flow over time. The results of this effort suggest that FESEM analysis coupled with advanced image analysis and machine learning techniques are effective in characterizing and quantifying the mineralogy, porosity, fractures, and OM content of 2-D imagery at the high resolution needed to identify features of interest in tight rocks. In addition, the image analysis techniques allow for identification and quantification of different porosity types as well as the key mineral components and/or OM that CO2 would contact in the reservoir as it migrates through pores and fracture networks. This is key information needed to better estimate the CO2 storage resource potential of organic-rich shales and other tight reservoirs. Additional work is needed to determine the sorptive capacity of the individual sample components (OM and clay minerals) at reservoir conditions so that this approach and the refined CO2 storage resource equation can be applied to other shale and unconventional reservoirs. In addition, subsequent work should be performed to better understand the number of images needed to use stereological approaches to estimate the volume of sample components using 2-D imagery, to explore machine learning techniques to differentiate between induced vs. natural fractures, and to estimate the connectivity of pores and fracture networks using 2-D imagery. Being able to derive this information at the microscale would facilitate scaling up of the sample characterization data used for reservoir modeling and simulation to estimate the CO2 storage resource potential of tight formations.

03 NATURAL GAS↗

Bats flying through a Y-maze are visually attracted to wind turbine surfaces

Wind energy’s rapid expansion has led to unintended consequences for wildlife, with migratory bats among the species most at risk. The behavioural mechanisms underlying collisions remain poorly understood, but one hypothesis is that bats are attracted to wind turbine structures. Vision is important to bat orientation and obstacle avoidance, yet it has been relatively understudied in the context of bat–turbine interactions. We hypothesize that light reflected off turbine surfaces could attract bats, acting as a sensory pollutant that may increase collision risk. To test whether reflective turbine surfaces elicit attraction, we flew 242 Lasiurus cinereus and 154 Lasionycteris noctivagans through Y-maze assays. Bats were at least twice as likely to fly towards white turbine blade sections compared to less reflective black ones. This attraction intensified when the alternative exit was a dark, empty flyway, with 74% of L. cinereus and 97% of L. noctivagans flying towards the white turbine blade. These findings provide evidence that visual sensory pollutants could underlie bat–turbine interactions, and if so, wind turbines could be ecological traps.

17 WIND ENERGY↗

Europium-doped aluminum oxide phosphors as indicators for frontal polymerization dynamics

In this study, we present an inexpensive and practical method that allows the monitoring and visualization of front polymerization, propagation, and dynamics. Commercially available europium-doped aluminum oxide powders were combined with video imaging to visualize free-radical propagating polymer fronts. In order to demonstrate the applicability of this method, frontal copolymerization reactions of propoxylated glycerin triacrylate (EB53), pentaerythritol triacrylate (PETA), and pentaerythritol tetra-acrylate (PETEA) with 1,1-Bis(tert-butylperoxy)-3,3,5-trimethylcyclohexane (Luperox 231®) as an initiator were studied and compared to the results obtained by IR imaging. Systems exhibiting higher filler loading, higher EB53 content, and less acrylated monomers showed a marked decrease in front velocity, while those with more acrylated monomers and higher crosslinking density showed a marked increase in front velocity. Finally, in order to show the potential of the imaging technique, we studied fronts propagating in planar and spherical geometries.

36 MATERIALS SCIENCE↗

Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report

Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations

08 HYDROGEN↗