Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Layered topological semimetal GaGeTe: New polytype with non-centrosymmetric structure

GaGeTe is a layered van der Waals material composed of germanene and GaTe sublayers that has been recently predicted to be a basic Z 2 topological semimetal. To date, only one polytype of GaGeTe is known with trigonal centrosymmetric structure (α phase, space group R-3m, No. 166). Here we show that as-grown samples of GaGeTe show traces of at least another polytype with hexagonal non-centrosymmetric structure (β phase, space group P6 3 mc, No. 186). Moreover, we suggest that another bulk hexagonal polytype (γ phase, space group P-3m1, No. 164) could also be found near room conditions. Both α and β polytypes have been identified and characterized by means of X-ray diffraction and Raman scattering measurements with the support of ab initio calculations. We provide the vibrational properties of both polytypes and show that the Raman spectrum reported for GaGeTe almost forty years ago and attributed to the α phase, was, in fact, that of the secondary β phase. Additionally, we show that a Fermi resonance occurs in α-GaGeTe under non-resonant excitation conditions, but not under resonant excitation conditions. Theoretical calculations show that bulk β-GaGeTe is a non-centrosymmetric weak topological semimetal with even smaller lattice thermal conductivity than centrosymmetric bulk α-GaGeTe. In perspective, our work paves the way for the control and engineering of GaGeTe polytypes to design and implement complex van der Waals heterostructures formed by a combination of centrosymmetric and non-centrosymmetric layers of up to three different polytypes in a single material, suitable for a number of fundamental studies and technological applications.

36 MATERIALS SCIENCE↗

Development of FeCrAl-ODS steels for ATF cladding

As an enhanced accident tolerant fuel (ATF) for LWR at severe accident condition, FeCrAl-ODS ferritic steels have been developed, and their applicability is being studied under the Japanese MEXT program. Alloying design of FeCrAl-ODS ferritic steels has been conducted, focusing on effect of mutual interaction of Cr-Al on oxidation resistance and α'-embrittlement. Effects of co-addition of Zr and excessive oxygen have also been studied to improve high-temperature strength. The ring tensile test of the manufactured claddings showed that tensile strength increases by Zr-addition and Zr-added FeCrAl-ODS steels have the highest strength among the existed steels at entire temperature range from room temperature up to 1000 Celsius degrees. Although Zr-addition sometimes leads to growth of alumina scale by rapid inward diffusion of oxygen through zirconia inside alumina, oxidation rate of Zr-added FeCrAl-ODS steels was successfully reduced to the level of Zr-free specimen by controlling oxygen content to form Y{sub 2}Zr{sub 2}O{sub 7} inside ODS steel matrix. This finding makes possible to improve not only high-temperature strength but also steam oxidation resistance in the Zr-added FeCrAl-ODS steels. (authors)

36 MATERIALS SCIENCE↗

A Computuerized Operator Support System Prototype

A report was published by the Idaho National Laboratory in September of 2012, entitled Design to Achieve Fault Tolerance and Resilience, which described the benefits of automating operator actions for transients. The report identified situations in which providing additional automation in lieu of operator actions would be advantageous. It recognized that managing certain plant upsets is sometimes limited by the operator’s ability to quickly diagnose the fault and to take the needed actions in the time available. Undoubtedly, technology is underutilized in the nuclear power industry for operator assistance during plant faults and operating transients. In contrast, other industry sectors have amply demonstrated that various forms of operator advisory systems can enhance operator performance while maintaining the role and responsibility of the operator as the independent and ultimate decision-maker. A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS does not supplant the role of the operator, but rather provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast-moving, complex events. This project proposes a general model for a control room COSS that addresses a sequence of general tasks required to manage any plant upset: detection, validation, diagnosis, recommendation, monitoring, and recovery. The model serves as a framework for assembling a set of technologies that can be interrelated to assist with each of these tasks. A prototype COSS has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Computuerized Operator Support System Prototype

A report was published by the Idaho National Laboratory in September of 2012, entitled Design to Achieve Fault Tolerance and Resilience, which described the benefits of automating operator actions for transients. The report identified situations in which providing additional automation in lieu of operator actions would be advantageous. It recognized that managing certain plant upsets is sometimes limited by the operator’s ability to quickly diagnose the fault and to take the needed actions in the time available. Undoubtedly, technology is underutilized in the nuclear power industry for operator assistance during plant faults and operating transients. In contrast, other industry sectors have amply demonstrated that various forms of operator advisory systems can enhance operator performance while maintaining the role and responsibility of the operator as the independent and ultimate decision-maker. A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS does not supplant the role of the operator, but rather provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast-moving, complex events. This project proposes a general model for a control room COSS that addresses a sequence of general tasks required to manage any plant upset: detection, validation, diagnosis, recommendation, monitoring, and recovery. The model serves as a framework for assembling a set of technologies that can be interrelated to assist with each of these tasks. A prototype COSS has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-Column Experimental Test Bed for Xe/Kr Separation

Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both tests. The effluent from the AgZ-PAN column was monitored via GC-TCD during the tests with no xenon being observed exiting the column during either test. Samples from each column were taken via evacuated sample bombs and were analyzed by GC-MS analysis. The results demonstrated the ability to separate xenon from krypton from a mixed gas feed utilizing the new multi-column system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanodiamond-based nanostructures for coupling nitrogen-vacancy centres to metal nanoparticles and semiconductor quantum dots

The ability to control the interaction between nitrogen-vacancy centres in diamond and photonic and/or broadband plasmonic nanostructures is crucial for the development of solid-state quantum devices with optimum performance. However, existing methods typically employ top-down fabrication, which restrict scalable and feasible manipulation of nitrogen-vacancy centres. Here, we develop a general bottom-up approach to fabricate an emerging class of freestanding nanodiamond-based hybrid nanostructures with external functional units of either plasmonic nanoparticles or excitonic quantum dots. Precise control of the structural parameters ( including size, composition, coverage and spacing of the external functional units) is achieved, representing a pre-requisite for exploring the underlying physics. Fine tuning of the emission characteristics through structural regulation is demonstrated by performing single-particle optical studies. Lastly, this study opens a rich toolbox to tailor properties of quantum emitters, which can facilitate design guidelines for devices based on nitrogen vacancy centres that use these freestanding hybrid nanostructures as building blocks.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A scanning Hall probe microscope for high resolution magnetic imaging down to 300 mK

We present the design, construction, and performance of a low-temperature scanning Hall probe microscope with submicron lateral resolution and a large scanning range. The detachable microscope head is mounted on the cold flange of a commercial {sup 3}He-refrigerator (Oxford Instruments, Heliox VT-50) and operates between room temperature and 300 mK. It is fitted with a three-axis slip-stick nanopositioner that enables precise in situ adjustment of the probe location within a 6x6x7 mm{sup 3} space. The local magnetic induction at the sample surface is mapped with an easily changeable microfabricated Hall probe [typically GsAs/AlGaAs or AlGaAs/InGaAs/GaAs Hall sensors with integrated scanning tunnel microscopy (STM) tunneling tips] and can achieve minimum detectable fields {>=}10 mG/Hz{sup 1/2}. The Hall probe is brought into very close proximity to the sample surface by sensing and controlling tunnel currents at the integrated STM tip. The instrument is capable of simultaneous tunneling and Hall signal acquisition in surface-tracking mode. We illustrate the potential of the system with images of superconducting vortices at the surface of a Nb thin film down to 372 mK, and also of labyrinth magnetic-domain patterns of an yttrium iron garnet film captured at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable thermal expansion and magnetism in Zr-doped ScF 3

The negative thermal expansion (NTE) behavior provides us an opportunity to design materials with controllable coefficient of thermal expansion (CTE). In this letter, we report a tunable isotropic thermal expansion in the cubic (Sc 1-x Zr x )F 3+δ over a wide temperature and CTE range ($α$ l = -4.0 to+ 16.8 x 10 -6 K -1 , 298–648 K). The thermal expansion can be well adjusted from strong negative to zero, and finally to large positive. Intriguingly, isotropic zero thermal expansion ($α$ l = 2.6 x 10 -7 K -1 , 298–648 K) has been observed in the composition of (Sc 0.8 Zr 0.2 )F 3+δ . The controllable thermal expansion in (Sc 1-x Zr x )F 3+δ is correlated to the local structural distortion. Interestingly, the ordered magnetic behavior has been found in the zero thermal expansion compound of (Sc 0.8 Zr 0.2 )F 3+δ at room temperature, which presumably correlates with the unpaired electron of the lower chemical valence of Zr cation. We conclude the present study provides a useful reference to control the thermal expansion and explore the multi-functionalization for NTE materials.

36 MATERIALS SCIENCE↗

An Optically Stimulated Luminescence Uranium Enrichment Monitor

The Pacific Northwest National Laboratory (PNNL) has pioneered the use of Optically Stimulated Luminescence (OSL) technology for use in personnel dosimetry and high dose radiation processing dosimetry. PNNL has developed and patented an alumina-based OSL dosimeter that is being used by the majority of medical X-ray and imaging technicians worldwide. PNNL has conceived of using OSL technology to passively measure the level of UF6 enrichment by attaching the prototype OSL monitor to pipes containing UF6 gas within an enrichment facility. The prototype OSL UF6 monitor utilizes a two-element approach with the first element open and unfiltered to measure both the low energy and high energy gammas from the UF6, while the second element utilizes a 3-mm thick tungsten filter to eliminate the low energy gammas and pass only the high energy gammas from the UF6. By placing a control monitor in the room away from the UF6 pipes and other ionizing radiation sources, the control readings can be subtracted from the UF6 pipe monitor measurements. The ratio of the shielded to the unshielded net measurements provides a means to estimate the level of uranium enrichment. PNNL has replaced the commercially available MicroStar alumina-based dosimeter elements with a composite of polyethylene plastic, high-Z glass powder, and BaFBr:Eu OSL phosphor powder at various concentrations. The high-Z glass was added in an attempt to raise the average “Z” of the composite dosimeter and increase the response. Additionally, since BaFBr:Eu OSL phosphor is optimally excited and emits light at different wavelengths compared to alumina, the commercially available MicroStar reader was modified for reading BaFBr:Eu in a parallel effort to increase reader sensitivity. PNNL will present the design and performance of our novel OSL uranium enrichment monitor based on a combination of laboratory and UF6 test loop measurements. PNNL will also report on the optimization effort to achieve the highest possible performance from both the OSL enrichment monitor and the new custom OSL reader modified for this application. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kinetics of moisture-induced phase transformation in inorganic halide perovskite

The high-temperature (high-T) phase of cesium lead iodide (CsPbI 3 ) presents great promise for photovoltaic applications; however, exposure to ambient moisture at room temperature transforms it into its less-desirable low-temperature (low-T) phase with a larger band gap. While there have been theoretical predictions on the influence of moisture level on the phase transformation kinetics, the corresponding quantitative experimental evidence has remained limited. Tracking CsPbI 3 phase transformation under controlled relative humidity (RH), we find that rising RH increases the nucleation rate of low-T CsPbI 3 exponentially, but has a weak effect on its growth. The overall transformation is nucleation limited, with higher RH leading to a lower nucleation barrier. Finally, we find that heating between 40°C and 80°C facilitates water desorption and suppresses phase transformation. Our findings elucidate the relationship between moisture and the phase energetics of CsPbI 3 , which can serve as references for thin film applications of CsPbI 3 and future designs of stable photovoltaics systems.

36 MATERIALS SCIENCE↗

Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)

Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.

01 COAL, LIGNITE, AND PEAT↗

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A versatile technique to enable sub-milli-Kelvin instrument stability for precise radial velocity measurements: tests with the habitable-zone planet finder

Insufficient instrument thermomechanical stability is one of the many roadblocks for achieving 10 cm s{sup −1} Doppler radial velocity precision, the precision needed to detect Earth-twins orbiting solar-type stars. Highly temperature and pressure stabilized spectrographs allow us to better calibrate out instrumental drifts, thereby helping in distinguishing instrumental noise from astrophysical stellar signals. We present the design and performance of the Environmental Control System (ECS) for the Habitable-zone Planet Finder (HPF), a high-resolution (R = 50,000) fiber-fed near-infrared (NIR) spectrograph for the 10 m Hobby–Eberly Telescope at McDonald Observatory. HPF will operate at 180 K, driven by the choice of an H2RG NIR detector array with a 1.7 μm cutoff. This ECS has demonstrated 0.6 mK rms stability over 15 days at both 180 and 300 K, and maintained high-quality vacuum (<10{sup −7} Torr) over months, during long-term stability tests conducted without a planned passive thermal enclosure surrounding the vacuum chamber. This control scheme is versatile and can be applied as a blueprint to stabilize future NIR and optical high-precision Doppler instruments over a wide temperature range from ∼77 K to elevated room temperatures. A similar ECS is being implemented to stabilize NEID, the NASA/NSF NN-EXPLORE spectrograph for the 3.5 m WIYN telescope at Kitt Peak, operating at 300 K. A [full SolidWorks 3D-CAD model] and a comprehensive parts list of the HPF ECS are included with this manuscript to facilitate the adaptation of this versatile environmental control scheme in the broader astronomical community.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrochemical Control of the Ultrafast Lattice Response of a Layered Semimetal

The unique layer-stacking in two-dimensional (2D) van der Waals materials facilitates the formation of nearly degenerate phases of matter and opens novel routes for the design of low-power, reconfigurable functional materials. Electrochemical ion intercalation between stacked layers offers a promising approach to stabilize bulk metastable phases and to explore the effects of extreme carrier doping and strain. However, in situ characterization methods to study the structural evolution and dynamical functional properties of these intercalated materials remains limited. Here a novel experimental platform is presented capable of simultaneously performing electrochemical lithium-ion intercalation and multimodal ultrafast characterization of the lattice using both electron diffraction and nonlinear optical techniques. Using the layered semimetal WTe 2 as a model system, the interlayer shear phonon mode that modulates stacking between 2Dlayers is probed, showing that small amounts of lithiation enhance the amplitude and lifetime of the phonon, contrary to expectations. This results from the dynamically fluctuating and anharmonic structure between nearly degenerate phases at room temperature, which can be stabilized by electronic carriers accompanying the inserted lithium ions. At high lithiation, the T d ’ structure emerges and quenches the phonon response. This work defines new approaches for using electrochemistry to engineer the dynamic structure of 2D materials.

36 MATERIALS SCIENCE↗

Deterministic incident-wave elevation prediction in intermediate water depth

Potential performance gains from optimal (non-causal) impedance-matching control of wave energy devices in irregular ocean waves are dependent on deterministic wave elevation prediction techniques that work well in practical applications. Although a number of devices are designed for operation in intermediate water depths, little work has been reported on deterministic wave prediction in such depths. Here, we investigated a deterministic wave-prediction technique based on an approximate propagation model that leads to an analytical formulation, which may be convenient to implement in practice. To improve accuracy, an approach to combine predictions based on multiple up-wave measurement points is evaluated. The overall method is tested using experimental time-series measurements recorded in the U.S. Navy MASK basin in Carderock, MD, USA. For comparison, an alternative prediction approach based on Fourier coefficients is also tested with the same data. Comparison of prediction approaches with direct measurements suggest room for improvement. Possible sources of error including tank reflections are estimated, and potential mitigation approaches are discussed.

16 TIDAL AND WAVE POWER↗

Computational fluid dynamic modeling to determine the indoor environment of an electron-ion collider service building

The design for the Electron-Ion Collider (EIC) calls for several service buildings that house various power supplies and control electronics for the collider ring itself. In order to operate within specified conditions, the ambient air entering the power supplies needs to be within a certain temperature range while dissipating the heat from losses. Proper cooling is therefore a necessity in the service buildings to ensure that every aspect of the EIC works as intended. Since the EIC is in the design stage, we are evaluating the indoor environment of the service building using the current design specifications. We have researched multiple forms of literature and performed the necessary calculations to compile a list of boundary conditions that accurately represent the situation at hand. We are using computational fluid dynamics modeling to solve the conservation equations for mass, momentum, and energy (Navier-Stokes). This allows us to perform a finite element analysis which will give us the flow distribution in the room as well as temperature profiles throughout the building. We have obtained a simulation result giving us the temperature profiles for the building and it shows that the placement of the racks and supply vents are essential to obtaining an even temperature distribution. This model will provide a basis for design decisions which will affect the overall cooling of the service building without extending the schedule and avoiding a costly reworking of the cooling system.

43 PARTICLE ACCELERATORS↗