Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Cw and Q-switched Nd:NaLa(MoO{sub 4}){sub 2} laser noncritical to the temperature drift of the diode pump laser wavelength

Lasing in Nd:NaLa(MoO{sub 4}){sub 2} crystals is obtained without stabilisation of the diode pump wavelength. A dependence of the cw laser power (at a wavelength of 1059 nm) on the pump diode temperature is found within a range of 10-458C. It is shown that the variations in the diode temperature within this region change the lasing efficiency no more than by 30%. In the passive Q-switching regime, the experiments were performed under both pulsed and cw pumping. Upon pulsed pumping, the laser energy was 16 {mu}J at the output pulse duration of 11 ns. The laser wavelength was 1059 nm, as well as in the case of cw operation. Upon cw pumping with a power of 1.5 W, laser pulses were obtained with an energy of 15 {mu}J. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-power pulsed laser diodes emitting in the range 1.5 – 1.6 μm

This paper examines approaches for increasing the output pulse power of laser diodes based on MOVPE InGaAs/AlGaInAs/InP heterostructures and emitting in the range 1.5 – 1.6 μm. We demonstrate that optimising waveguide layer parameters may ensure an increase in the quantum efficiency of the laser diodes and a reduction in their internal optical loss. Characterisation results are presented for laser diodes based on the proposed heterostructures. (lasers)

36 MATERIALS SCIENCE↗

Spectral features and thermal resistance of 976-nm cw laser diodes with a power up to 15 W

The spectral characteristics of cw laser diodes with a maximum reliable power of 15 W mounted on F-mount heat sinks are studied. It is found that the spectrum envelopes have features at emission powers exceeding 5 – 7 W. A method for determining the maximum of a spectrum envelope under the conditions of its broadening and appearance of features is discussed. The thermal resistance of diodes is determined experimentally at pump currents from threshold to maximum (14 A) and is found to be 2.25 K W{sup -1} at a current of 10 A and 1.5 K W{sup -1} at a current of 4 A. The results obtained are compared with the literature data. The adequacy of using the thermal resistance parameter for comparing and estimating thermal characteristics of laser diodes is considered. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametric amplification of broadband radiation of a cw superluminescent diode under picosecond pumping

It is proposed to use cw superluminescent diodes with a spectral width of about 300 cm{sup −1} and high spatial coherence as seed radiation sources in parametric amplifiers with picosecond pumping in order to form broadband picosecond pulses. A two-cascade parametric amplifier based on BaB{sub 2}O{sub 4} (BBO) crystals is pumped by 20-ps pulses of the second harmonic of an Nd : YAG laser. For a superluminescent diode spectral width of 275 cm{sup −1} (centre wavelength 790 nm), the spectral width of picosecond pulses at the parametric amplifier output is 203 cm{sup −1}. At a total pump energy of 7.2 mJ for BBO crystals, the energy of the enhanced emission of the superluminescent diode is found to be 0.6 mJ.

42 ENGINEERING↗

Magnus induced diode effect for skyrmions in channels with periodic potentials

Using a particle based model, we investigate the skyrmion dynamical behavior in a channel where the upper wall contains divots of one depth and the lower wall contains divots of a different depth. Under an applied driving force, skyrmions in the channels move with a finite skyrmion Hall angle that deflects them toward the upper wall for -x direction driving and the lower wall for +x direction driving. When the upper divots have zero height, the skyrmions are deflected against the flat upper wall for -x direction driving and the skyrmion velocity depends linearly on the drive. For +x direction driving, the skyrmions are pushed against the lower divots and become trapped, giving reduced velocities and a nonlinear velocity-force response. When there are shallow divots on the upper wall and deep divots on the lower wall, skyrmions get trapped for both driving directions; however, due to the divot depth difference, skyrmions move more easily under -x direction driving, and become strongly trapped for +x direction driving. Further, the preferred -x direction motion produces what we call a Magnus diode effect since it vanishes in the limit of zero Magnus force, unlike the diode effects observed for asymmetric sawtooth potentials. We show that the transport curves can exhibit a series of jumps or dips, negative differential conductivity, and reentrant pinning due to collective trapping events. We also discuss how our results relate to recent continuum modeling on a similar skyrmion diode system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of the junction voltage on the overflow current in light-emitting diodes

Quantum-well (QW)-based light emitters, such as light-emitting diodes (LEDs) and lasers, of various semiconductor materials experience a reduction in their efficiency when operating at higher temperatures, a phenomenon referred to as “thermal droop.” Among the various claims on the origins of thermal droop, an increased overflow current with increasing temperatures is a common contender. Since overflow of carriers can only occur when the junction voltage 𝑉 Junction approaches the built-in voltage 𝑉 BI of any diodes, we develop a simple method relating the difference between 𝑉 Junction and 𝑉 BI to approximate the upper limit of overflow occurring in QW-based light-emitting diodes. The measured difference between 𝑉 Junction and 𝑉 BI of state-of-the-art commercial blue and green In⁢Ga⁢N-based LEDs at temperatures up to ∼450 K suggests negligible overflow. To further experimentally verify the absence of overflow, we perform temperature-dependent electron emission spectroscopy on the same commercial blue and green LEDs and find no evidence of thermally enhanced overflow carriers up to ∼450 K. In agreement with our claims that 𝑉 Junction must approach 𝑉 BI for overflow to occur, two-dimensional temperature-dependent electrical simulations of violet, blue, and green LEDs including alloy disorder and V-defects demonstrate that overflow can be significant in violet LEDs, where the small band offset between the In⁢Ga⁢N QW and Ga⁢N cladding layers due to the larger QW bandgap requires larger 𝑉 Junction to reach standard operating current densities, thereby approaching 𝑉 BI . By contrast, simulations indicate that overflow is negligible in blue and green LEDs, whose smaller QW bandgaps result in smaller quasi-Fermi levels difference to reach significant carrier injection, resulting in a 𝑉 Junction much smaller than 𝑉 BI up to large operating current densities. Considering that overflow is negligible in blue and longer-wavelength LEDs, and our observations of the large thermal droop occurring at low current densities, where Shockley-Read-Hall (SRH) recombination dominates, we conclude that thermally enhanced SRH processes are the most significant contributor to thermal droop. Finally, we also simulate the carrier densities in the different QWs of a multiple-QW LED and observe a reduction in the total carrier density at a given operating current density, which results in a decrease in the total Auger-Meitner current of the LED from just the thermally enhanced carrier redistribution among QWs without taking any possible additional temperature dependence of their recombination coefficients. Taking all this into account, minimizing thermal droop effects in LEDs can be achieved by a reduction in defect density, using wider band gap p-n junction-defining cladding layers, and operating at higher currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

All-optical diode action in asymmetric nonlinear photonic multilayers with perfect transmission resonances

Light propagation in asymmetric Kerr-nonlinear multilayers with perfect transmission resonances is theoretically investigated. It is found that hybrid Fabry-Perot-resonator-photonic-crystal structures of the type (BA){sup k}(AB){sup k}(AABB){sup m} exhibit both pronounced unidirectionality (due to strong spatial asymmetry of the resonant mode) and high transmission (due to the existence of a perfect transmission resonance). This results in nonlinear optical diode action with low reflection losses without need for a pumping beam or input pulse modulation. By slightly perturbing the perfect transmission resonance condition, the operating regime of the optical diode can be tuned, with a tradeoff between minimizing the reflection losses and maximizing the frequency bandwidth where unidirectional transmission exists. Optical diode action is demonstrated in direct numerical simulation, showing >92% transmittance in one direction and about 22% in the other. The effect of perfect transmission resonance restoration induced by nonlinearity was observed analytically and numerically. The proposed geometry is shown to have advantages over previously reported designs based on photonic quasicrystals.

36 MATERIALS SCIENCE↗

Analysis of Diode Reverse Recovery Effect on ZVS Condition for GaN-Based LLC Resonant Converter

LLC resonant converter can achieve zero voltage switching (ZVS) for primary-side devices and zero current switching (ZCS) for secondary-side rectifiers. However, the reverse recovery and junction capacitance (C j ) of secondary-side diode critically affect the ZVS condition of primary-side switches. The effect of C j has been discussed in literature, but not the reverse recovery. In this paper, the reverse recovery charge (Q rr ) is converted to an equivalent capacitance (C rr_eq ) for the study of primary-side ZVS performance. An accurate model during deadtime is derived and further applied to characterize ZVS performance with different reverse recovery charges in different regions. The concept of establishing parameter C total to consider both C j and C rr_eq is proposed to evaluate the effect of the secondary-side rectifiers. This concept provides the guideline for diode and synchronous rectification MOSFET selection to ensure ZVS condition for LLC converters. To verify the concept and the derived model,a 200/400 V 400 W LLC resonant converter prototype operating from 200 to 700 kHz is built and its ZVS performances with different diodes are compared. Two issues caused by Q rr effect, including V ds reverse charging and asymmetrical waveform during deadtime, are explained thoroughly as well.

42 ENGINEERING↗

Low-temperature electrical properties and barrier inhomogeneities in ITO/β-Ga2O3 Schottky diode

This study reports the electronic properties of the indium tin oxide (ITO)/β-Ga2O3 Schottky diode through the temperature (50–320 K)-dependent current density–voltage, capacitance–voltage, and admittance spectroscopy experiments. The room-temperature turn-on voltage of the ITO/β-Ga2O3 diode was observed to be 0.83 V, and it exhibited a slow increase with decreasing temperature. The ITO/β-Ga2O3 diode's ideality factor (n) varied from 3.92 to 1.05, and the zero-bias Schottky barrier height (φbo) varied from 0.31 to 1.28 eV. The temperature-dependent n and φbo indicate the spatial inhomogeneities of the potential barrier at the Ga2O3-ITO interface. We exploit the Gaussian distribution model to explain the Schottky barrier inhomogeneities, which could be associated with the defects observed by the admittance spectroscopy method.

Engineering↗

A synthetic diamond diode in volumetric modulated arc therapy dosimetry

Purpose: The aim of this work is to investigate the behavior of a single crystal diamond diode (SCDD) for volumetric modulated arc therapy (VMAT) dose verifications. This delivery technique is one of the most severe test of a dosimeter performance due to the modulation of the dose rate achieved by simultaneously changing the velocity of the gantry and the position of the collimator leaves. The performed measurements with VMAT photon beams can therefore contribute to an overall global validation of the device to be used in dose distribution verifications.Methods: The SCDD response to 6 MVRX has been tested and compared with reference ionization chambers and treatment planning system (TPS) calculations in different experiments: (a) measurements of output factors for small field sizes (square fields of side ranging between 8 mm and 104 mm) by SCDD and A1SL ionization chamber; (b) angular dependence evaluation of the entire experimental set-up by SCDD, A1SL, and Farmer ionization chambers; and (c) acquisition of dose profiles for a VMAT treatment of a pulmonary disease in latero-lateral and gantry-target directions by SCDD and A1SL ionization chamber.Results: The output factors measured by SCDD favorably compare with the ones obtained by A1SL, whose response is affected by the lack of charged particle equilibrium and by averaging effect when small fields are involved. From the experiment on angular dependence, a good agreement is observed among the diamond diode, the ion chambers, and the TPS. In VMAT profiles, the absorbed doses measured by SCDD and A1SL compare well with the TPS calculated ones. An overall better agreement is observed in the case of the diamond dosimeter, which is also showing a better accuracy in terms of distance to agreement in the high gradient regions.Conclusions: Synthetic diamond diodes, whose performance were previously studied for conformal and IMRT radiotherapy techniques, were found to be suitable detectors also for dosimetric measurements in volumetric arc therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality assurance of asymmetric jaw alignment using 2D diode array

Purpose: A method using a 2D diode array is proposed to measure the junction gap (or overlap) and dose with high precision for routine quality assurance of the asymmetric jaw alignment.Methods: The central axis (CAX) of the radiation field was determined with a 15 × 15 cm{sup 2} photon field at four cardinal collimator angles so that the junction gap (or overlap) can be measured with respect to the CAX. Two abutting fields having a field size of 15 cm (length along the axis parallel to the junction) × 7.5 cm (width along the axis perpendicular to the junction) were used to irradiate the 2D diode array (MapCHECK2) with 100 MU delivered at the photon energy of 6 MV. The collimator was slightly rotated at 15° with respect to the beam central axis to increase the number of diodes effective on the measurement of junction gap. The junction gap and dose measured in high spatial resolution were compared to the conventional methods using an electronic portal imaging device (EPID) and radiochromic film, respectively. In addition, the reproducibility and sensitivity of the proposed method to the measurements of junction gap and dose were investigated.Results: The junction gap (or overlap) and dose measured by MapCHECK2 agreed well to those measured by the conventional methods of EPID and film (the differences ranged from −0.01 to 0 cm and from −1.34% to 0.6% for the gap and dose, respectively). No variation in the repeat measurements of the junction gap was found whereas the measurements of junction dose were found to vary in quite a small range over the days of measurement (0.21%–0.35%). While the sensitivity of the measured junction gap to the actual junction gap applied was the ideal value of 1 cm/cm as expected, the sensitivity of the junction dose to the actual junction gap increased as the junction gap (or overlap) decreased (maximum sensitivity: 201.7%/cm).Conclusions: The initial results suggest that the method is applicable for a comprehensive quality assurance of the asymmetric jaw alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRE-06: Evaluation of Patient CT Dose Reconstruction From 3D Diode Array Measurements Using Anthropomorphic Phantoms

Purpose: To compare 3D reconstructed dose of IMRT plans from 3D diode array measurements with measurements in anthropomorphic phantoms. Methods: Six IMRT plans were created for the IROC Houston (RPC) head and neck (H and N) and lung phantoms following IROC Houston planning protocols. The plans included flattened and unflattened beam energies ranging from 6 MV to 15 MV and both static and dynamic MLC tecH and Niques. Each plan was delivered three times to the respective anthropomorphic phantom, each of which contained thermoluminescent dosimeters (TLDs) and radiochromic films (RCFs). The plans were also delivered to a Delta4 diode array (Scandidos, Uppsala, Sweden). Irradiations were done using a TrueBeam STx (Varian Medical Systems, Palo Alto, CA). The dose in the patient was calculated by the Delta4 software, which used the diode measurements to estimate incident energy fluence and a kernel-based pencil beam algorithm to calculate dose. The 3D dose results were compared with the TLD and RCF measurements. Results: In the lung, the average difference between TLDs and Delta4 calculations was 5% (range 2%–7%). For the H and N, the average differences were 2.4% (range 0%–4.5%) and 1.1% (range 0%–2%) for the high- and low-dose targets, respectively, and 12% (range 10%-13%) for the organ-at-risk simulating the spinal cord. For the RCF and criteria of 7%/4mm, 5%/3mm, and 3%/3mm, the average gamma-index pass rates were 95.4%, 85.7%, and 76.1%, respectively for the H and N and 76.2%, 57.8%, and 49.5% for the lung. The pass-rate in the lung decreased with increasing beam energy, as expected for a pencil beam algorithm. Conclusion: The H and N phantom dose reconstruction met the IROC Houston acceptance criteria for clinical trials; however, the lung phantom dose did not, most likely due to the inaccuracy of the pencil beam algorithm in the presence of low-density inhomogeneities. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: The dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-375: Evaluation of a MapCHECK2(tm) Planar 2-D Diode Array for High-Dose-Rate Brachytherapy Treatment Delivery Verifications

Purpose: Despite improvements of HDR brachytherapy delivery systems, verification of source position is still typically based on the length of the wire reeled out relative to the parked position. Yet, the majority of errors leading to medical events in HDR treatments continue to be classified as missed targets or wrong treatment sites. We investigate the feasibility of using dose maps acquired with a two-dimensional diode array to independently verify the source locations, dwell times, and dose during an HDR treatment. Methods: Custom correction factors were integrated into frame-by-frame raw counts recorded for a Varian VariSource™ HDR afterloader Ir-192 source located at various distances in air and in solid water from a MapCHECK2™ diode array. The resultant corrected counts were analyzed to determine the dwell position locations and doses delivered. The local maxima of polynomial equations fitted to the extracted dwell dose profiles provided the X and Y coordinates while the distance to the source was determined from evaluation of the full width at half maximum (FWHM). To verify the approach, the experiment was repeated as the source was moved through dwell positions at various distances along an inclined plane, mimicking a vaginal cylinder treatment. Results: Dose map analysis was utilized to provide the coordinates of the source and dose delivered over each dwell position. The accuracy in determining source dwell positions was found to be +/−1.0 mm of the preset values, and doses within +/−3% of those calculated by the BrachyVision™ treatment planning system for all measured distances. Conclusion: Frame-by-frame data furnished by a 2 -D diode array can be used to verify the dwell positions and doses delivered by the HDR source over the course of treatment. Our studies have verified that measurements provided by the MapCHECK2™ can be used as a routine QA tool for HDR treatment delivery verification.

60 APPLIED LIFE SCIENCES↗

SU-E-T-524: In-Vivo Diode Dosimetry Proton Therapy Range Verification Validation Study for Pediatric CSI

Purpose: With the aim of reducing acute esophageal radiation toxicity in pediatric patients receiving craniospinal irradiation (CSI), we investigated the implementation of an in-vivo, adaptive proton therapy range verification methodology. Simulation experiments and in-phantom measurements were conducted to validate the range verification technique for this clinical application. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification for a prostate treatment case by correlating properties of the detector signal to the water equivalent path length (WEPL). We propose to extend the methodology to verify range distal to the vertebral body for pediatric CSI cases by placing this small volume dosimeter in the esophagus of the anesthetized patient immediately prior to treatment. A set of calibration measurements was performed to establish a time signal to WEPL fit for a “scout” beam in a solid water phantom. Measurements are compared against Monte Carlo simulation in GEANT4 using the Tool for Particle Simulation (TOPAS). Results: Measurements with the diode array in a spread out Bragg peak of 14 cm modulation width and 15 cm range (177 MeV passively scattered beam) in solid water were successfully validated against proton fluence rate simulations in TOPAS. The resulting calibration curve allows for a sensitivity analysis of detector system response with dose rate in simulation and with individual diode position through simulation on patient CT data. Conclusion: Feasibility has been shown for the application of this range verification methodology to pediatric CSI. An in-vivo measurement to determine the WEPL to the inner surface of the esophagus will allow for personalized adjustment of the treatment plan to ensure sparing of the esophagus while confirming target coverage. A Toltz acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

SU-F-T-273: Using a Diode Array to Explore the Weakness of TPS DoseCalculation Algorithm for VMAT and Sliding Window Techniques

Purpose: To identify the weakness of dose calculation algorithm in a treatment planning system for volumetric modulated arc therapy (VMAT) and sliding window (SW) techniques using a two-dimensional diode array. Methods: The VMAT quality assurance(QA) was implemented with a diode array using multiple partial arcs that divided from a VMAT plan; each partial arc has the same segments and the original monitor units. Arc angles were less than ± 30°. Multiple arcs delivered through consecutive and repetitive gantry operating clockwise and counterclockwise. The source-toaxis distance setup with the effective depths of 10 and 20 cm were used for a diode array. To figure out dose errors caused in delivery of VMAT fields, the numerous fields having the same segments with the VMAT field irradiated using different delivery techniques of static and step-and-shoot. The dose distributions of the SW technique were evaluated by creating split fields having fine moving steps of multi-leaf collimator leaves. Calculated doses using the adaptive convolution algorithm were analyzed with measured ones with distance-to-agreement and dose difference of 3 mm and 3%.. Results: While the beam delivery through static and step-and-shoot techniques showed the passing rate of 97 ± 2%, partial arc delivery of the VMAT fields brought out passing rate of 85%. However, when leaf motion was restricted less than 4.6 mm/°, passing rate was improved up to 95 ± 2%. Similar passing rate were obtained for both 10 and 20 cm effective depth setup. The calculated doses using the SW technique showed the dose difference over 7% at the final arrival point of moving leaves. Conclusion: Error components in dynamic delivery of modulated beams were distinguished by using the suggested QA method. This partial arc method can be used for routine VMAT QA. Improved SW calculation algorithm is required to provide accurate estimated doses.

60 APPLIED LIFE SCIENCES↗

SU-F-T-326: Diode Array Transmission Detector Systems Evaluation

Purpose: A new transmission detector, Delta4 Discover, developed by Scandidos (Uppsala, Sweden) was evaluated for external photon beam verification and quality assurance. The device is an array of 4040 diodes designed to be mounted on the linac accessory tray to measure photon field shape, position and fluence during patient treatment. Interfractional measurements are compared to a baseline measurement made during delivery quality assurance. The aim of this work is to evaluate the stability of the device and its effect on the shape and magnitude of the treatment beam. Methods: Beam profiles, percent depth dose, and beam attenuation was measured for 6, 10, and 15 MV photon beams with and without the device in place for 1×1 and 30×30 cm2 fields. Changes in profile and percent depth dose was quantified to evaluate the need to recommission the treatment beam, or account for the device with a tray factor. The stability of the radiation measurements was evaluated by measuring the deviation of each diode measurement during repeated prostate VMAT treatment delivery. Results: Photon beam profiles changed by < 1.25% in the nonpenumbra regions of the 30×30 cm2 beam. Percent depth dose curves show a 5–7% increased dose at depths < 2.5cm, but agreed within 1% at depths > 2.5cm. This indicates increased skin dose, similar to the use of a physical beam wedge. The device attenuated 6, 10, and 15 MV photon beams by 1.71±0.02%, 1.36±0.03%, and 1.17±0.03%, respectively. The diode array reproduced dosimetric measurements within 0.5% standard deviation for repeated prostate VMAT measurement. Conclusion: The device demonstrated stabile radiation measurements, while not changing the treatment beam shape in a clinically significantly manner. Use of this device can be accounted for with a tray factor, as opposed to recommissioning the treatment beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of the Insulating Magnetic Field in an Accelerating Ion Diode

The results of examination of the insulating magnetic field in an accelerating ion diode are presented. This field is produced in order to suppress the electron current and thus enhance the neutron yield of the D(d, n){sup 3}He nuclear reaction. The following two designs are discussed: a gas-filled diode with inertial electrostatic confinement of ions and a vacuum diode with a laser-plasma ion source and pulsed magnetic insulation. Although the insulating field of permanent magnets is highly nonuniform, it made it possible to extend the range of accelerating voltages to U = 200 kV and raise the neutron yield to Q = 10{sup 7} in the first design. The nonuniform field structure is less prominent in the device with pulsed magnetic insulation, which demonstrated efficient deuteron acceleration with currents up to 1 kA at U = 400 kV. The predicted neutron yield is as high as 109 neutrons/pulse.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗