Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Halo removal experiments with hollow electron lens in the BNL Relativistic Heavy Ion Collider

A hollow electron beam has been proposed as an active control tool to remove the beam halo from high-energy, high-current hadron or ion machines (such as the High-Luminosity Large Hadron Collider). To study the halo removal rate and assess the effect on the ion beam core, one of the two electron lenses in the Relativistic Heavy Ion Collider was changed from a Gaussian beam profile to a hollow profile. We describe the design and verification of the hollow electron beam parameters as well as the methods to minimize the hollow beam profile distortions, which can result in an ion beam emittance increase. The hollow beam alignment with the ion beam by using a backscattered electron detector has been demonstrated. Furthermore, experiments were carried out to explore the efficiency of the halo removal by scanning the current and inner radius of the hollow electron beam, which is pulsed either every turn or every nth turn. The effects of the hollow electron beam on the ion beam emittance and luminosity were also assessed experimentally by scanning the inner radius of the electron beam.

43 PARTICLE ACCELERATORS↗

Response of an implantable MOSFET dosimeter to {sup 192}Ir HDR radiation

New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with {sup 192}Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector response. The detectors exhibited a higher sensitivity to {sup 192}Ir energies than {sup 60}Co energies. A nonlinear accumulated dose effect was characterized by three third-order polynomials fit to data from detectors placed at three different distances from the source. The detectors were found to have minimal rotational angular dependence. A strong longitudinal angular dependence was found when the detector's copper coil and electronics assembly were aligned between the MOSFETs and incident radiation. This orientation showed a 16% decrease in response relative to other orientations tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

Prototypes of self-powered radiation detectors employing intrinsic high-energy current

Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm{sup 2} for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of features of hydrodynamics and heat transfer in the fuel assembly of prospective sodium reactor with a high rate of reproduction in the uranium-plutonium fuel cycle

The fast sodium reactor fuel assembly (FA) with U–Pu–Zr metallic fuel is described. In comparison with a “classical” fast reactor, this FA contains thin fuel rods and a wider fuel rod grid. Studies of the fluid dynamics and the heat transfer were carried out for such a new FA design. The verification of the ANSYS CFX code was provided for determination of the velocity, pressure, and temperature fields in the different channels. The calculations in the cells and in the FA were carried out using the model of shear stress transport (SST) selected at the stage of verification. The results of the hydrodynamics and heat transfer calculations have been analyzed.

42 ENGINEERING↗

Electric System Intra-hour Operation Simulator

ESIOS is a software program developed at Pacific Northwest National Laboratory (PNNL) that performs intra-hour dispatch and automatic generation control (AGC) simulations for electric power system frequency regulation and load/variable generation following. The program dispatches generation resources at minute interval to meet control performance requirements, while incorporating stochastic models of forecast errors and variability with generation, load, interchange and market behaviors. The simulator also contains an operator model that mimics manual actions to adjust resource dispatch and maintain system reserves. Besides simulating generation fleet intra-hour dispatch, ESIOS can also be used as a test platform for the design and verification of energy storage, demand response, and other technologies helping to accommodate variable generation.

Lu, Shuai↗

thermal-grid-jba v1.0.0

This is a software repository that contains models for a feasibility study of a thermal energy network for Joint Base Andrews. The work has been conducted under the ESTCP program in the project https://serdp-estcp.mil/projects/details/0694868a-3d58-4a14-a587-b8f638bfcd5c The repository contains models for energy system selection and for verification of design. The DoD management intends to give access to this code for future feasibility studies at Joint Base Andrews and possibly other bases.

Wetter, Michael [Lawrence Berkeley National Labora↗

Optimizing Dynamic Timing Analysis with Reinforcement Learning

There are multiple factors involved in successfully manufacturing ASICIVLSI chips, and ensuring operational specifications are maintained throughout the design and manufacturing process is often challenging. Dynamic timing analysis (DTA) is the principal method used to validate that a manufactured chip complies to its design specifications. In DTA functionality of both synchronous and asynchronous designs are verified by applying input signals and checking for correct output signals. In complex designs where the number of input signal permutations is extremely large, the computing resources required to properly verify the functionality of a chip is prohibitive. In this paper, a strategy using reinforcement learning (RL) for reducing DTA time and resources in such cases is discussed. RL assisted DTA holds much promise in ensuring that VLSI chip design and functionality are fully and optimally verified.

42 ENGINEERING↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Graph Theory and IC Component Design Analysis

Graph analysis in large integrated circuit (IC) designs is an essential tool for verifying design logic and timing via dynamic timing analysis (DTA). IC designs resemble graphs with each logic gate as a vertex and the conductive connections between gates as edges. Using DTA digital statistical correlations, graph condensation, and graph partitioning, it is possible to identify high-entropy component centers and paths within an IC design. Identification of high-entropy component centers (HECC) enables focused DTA, effectively lowering the computational complexity of DTA on large integrated circuit graphs. In this paper, a devised methodology termed IC layout subgraph component center identification (CCI) is used to identify described. CCI lowers DTA computationally complexity by condensing IC graphs into reduced subgraphs in which dominant logic functions are verified.

42 ENGINEERING↗

Effective Access Monitoring at Geological Repositories

Access points at a deep, mined geological repository (GR) for the disposal of spent nuclear fuel (SNF) and other nuclear wastes present potential diversion paths for nuclear material. Because C/S measures are not likely to be used underground, access to a GR will require unprecedented reliance on C/S measures to maintain continuity of knowledge (CoK) on SNF buried underground. We develop a model GR based on common features of GR designs from national programs in order to develop and optimize C/S measures for GR access points that maximize confidence that CoK is maintained on SNF underground. Critical access points identified in this study are surface entrances to (1) the GR ramp (2) the excavation shaft, (3) the main elevator shaft, and (4) the ventilation shaft. The first three are considered critical detection points (DPs), whereas the fourth is considered a non-critical DP. The reason for the distinction is due to the different design capabilities of shaft components: the first three (ramp, excavation shaft, main elevator) are all capable of being used to move material from the underground to the surface, whereas the ventilation shaft is not. Such capabilities are verified during periodic design information verification (DIV) inspections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements with Pinhole and Coded Aperture Gamma-Ray Imaging Systems

From a safeguards perspective, gamma-ray imaging has the potential to reduce manpower and cost for effectively locating and monitoring special nuclear material. The purpose of this project was to investigate the performance of pinhole and coded aperture gamma-ray imaging systems at Oak Ridge National Laboratory (ORNL). With the aid of the European Commission Joint Research Centre (JRC), radiometric data will be combined with scans from a three-dimensional design information verification (3D-DIV) system. Measurements were performed at the ORNL Safeguards Laboratory using sources that model holdup in radiological facilities. They showed that for situations with moderate amounts of solid or dense U sources, the coded aperture was able to predict source location and geometry within ~7% of actual values while the pinhole gave a broad representation of source distributions

Raffo-Caiado, Ana Claudia↗

Specification, space station program (modular)

The modular concepts of a long-term manned scientific laboratory in earth orbit using the space shuttle for orbital buildup and logistics delivery are presented. The specifications defining the performance, design and verification requirements for the Modular Space Program are included.

Source record↗

Biomedical ground lead system

The design and verification tests for the biomedical ground lead system of Apollo biomedical monitors are presented. Major efforts were made to provide a low impedance path to ground, reduce noise and artifact of ECG signals, and limit the current flowing in the ground electrode of the system.

Source record↗

Residual water bactericide monitor development program

A silver-ion bactericidal monitor is considered for the Space Shuttle Potable Water System. Potentiometric measurement using an ion-selective electrode is concluded to be the most feasible of available techniques. Four commercially available electrodes and a specially designed, solid-state, silver-sulfide electrode were evaluated for their response characteristics and suitability for space use. The configuration of the solid-state electrode with its Nernstian response of 10 to 10,000 ppb silver shows promise for use in space. A pressurized double-junction reference electrode with a quartz-fiber junction and a replaceable bellows electrolyte reservoir was designed verification-tested, and paired with a solid-state silver-sulfide electrode in a test fixture.

Source record↗