Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

An overview of controls research on the NASA Langley Research Center grid

The NASA Langley Research Center has assembled a flexible grid on which control systems research can be accomplished on a two-dimensional structure that has many physically distributed sensors and actuators. The grid is a rectangular planar structure that is suspended by two cables attached to one edge so that out of plane vibrations are normal to gravity. There are six torque wheel actuators mounted to it so that torque is produced in the grid plane. Also, there are six rate gyros mounted to sense angular motion in the grid plane and eight accelerometers that measure linear acceleration normal to the grid plane. All components can be relocated to meet specific control system test requirements. Digital, analog, and hybrid control systems capability is provided in the apparatus. To date, research on this grid has been conducted in the areas of system and parameter identification, model estimation, distributed modal control, hierarchical adaptive control, and advanced redundancy management algorithms. The presentation overviews each technique and presents the most significant results generated for each area.

Montgomery, Raymond C.↗

Drug design from the cryptic inhibitor envelope

Conformational dynamics plays an important role in enzyme catalysis, allosteric regulation of protein functions and assembly of macromolecular complexes. Despite these well-established roles, such information has yet to be exploited for drug design. Here we show by nuclear magnetic resonance spectroscopy that inhibitors of LpxC—an essential enzyme of the lipid A biosynthetic pathway in Gram-negative bacteria and a validated novel antibiotic target—access alternative, minor population states in solution in addition to the ligand conformation observed in crystal structures. These conformations collectively delineate an inhibitor envelope that is invisible to crystallography, but is dynamically accessible by small molecules in solution. Drug design exploiting such a hidden inhibitor envelope has led to the development of potent antibiotics with inhibition constants in the single-digit picomolar range. The principle of the cryptic inhibitor envelope approach may be broadly applicable to other lead optimization campaigns to yield improved therapeutics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air Traffic Management Technology Demonstration - 3 (ATD-3) Dynamic Weather Routes Domestic En Route Concept of Operations Synopsis Version 1.0

NASA conducted a survey in 2015 of stakeholders in industry, flight operators, and others to collect data on the most pressing air traffic management (ATM) issues impacting en route operations. Weather related delays and interruptions were identified as the most significant and costly problem impacting en route operations in today's system. Additionally, future traffic demands will place greater demands on the FAA's air traffic control system, necessitate a more efficient and integrated traffic management system and provide controller tools to leverage human productivity. Consequently, NASA is assembling a suite of integrated ground and aircraft-based technologies and decision-making aids under the Airspace Technology Demonstrations 3 (ATD-3) project to continuously search for more efficient weather-avoidance routes and to rapidly respond to weather changes and associated traffic management initiatives. These route efficiency enhancements are targeted at en route airspace and will enable continued use of en route and arrival metering in the presence of weather. NASA's Dynamic Weather Routes (DWR) concept represents a subset of those technologies and focuses primarily on the cruise phase of flight. It leverages existing air traffic weather, airspace, and traffic data, as well as improvements in navigation, surveillance, communication and digital network technologies, and builds upon existing ATM automation to address the shortcomings associated with strategic traffic flow management initiatives and weather forecasting uncertainties. The potential benefits in the form of time, fuel, and cost savings are significant. This concept of operations synopsis provides a detailed description of DWR, its potential benefits and notional implementation paths.

DWR↗

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

Core Angular Momentum and the IERS Sub-Centers Activity for Monitoring Global Geophysical Fluids: Core Angular Momentum and Earth Rotation - Part 1

The part of the grant was to use recordings of seismic waves travelling through the earth's core (PKP waves) to study the inner core rotation and constraints on possible density anomalies in the fluid core. The shapes and relative arrival times of such waves associated with a common source were used to reduce the uncertainties in source location and excitation and the effect of unknown mantle structure. The major effort of the project is to assemble historical seismograms with long observing base lines. We have found original paper records of SSI earthquakes at COL between 1951 and 1966 in a warehouse of the U.S. Geological Survey office in Golden, Colorado, extending the previous measurements at COL by Song and Richards [1996] further back 15 years. Also in Alaska, the University of Alaska, Fairbanks Geophysical Institute (UAFGI) has been operating the Alaskan Seismic Network with over 100 stations since the late 1960s. Virtually complete archives of seismograms are still available at UAFGI. Unfortunately, most of the archives are in microchip form (develocorders), for which the use of waveforms is impossible. Paper seismograms (helicorders) are available for a limited number of stations, and digital recordings of analog signals started around 1989. Of the paper records obtained, stations at Gilmore Dome (GLM, very close to COL), Yukon (FYU), McKinley (MCK), and Sheep Creek Mountain (SCM) have the most complete continuous recordings.

Song, Xia-Dong↗

KBase Narrative - Porphyromonadaceae sp. W3.11 genome

Narratives for The phenotype and genotype of fermentative prokaryotes This is the Narrative for Porphyromonadaceae sp. W3.11. A complementary Narrative for Lachnospiraceae sp. C1.1 is available here. This is the Narrative for Lachnospiraceae sp. C1.1. A complementary Narrative for Porphyromonadaceae sp. W3.11 is available here. Background and Isolation This Narrative and its complementary Narrative contain assembly and annotation of two bacterial isolates that were isolated by our laboratory from the rumen of a Holstein heifer. All procedures with animals have been approved by University of California Davis’s Institutional Animal Care and Use Committee. Rumen contents were collected through a rumen fistula and strained through two layers of cheesecloth into a bottle. The bottle was sealed to exclude air and maintained at 39°C. Contents were brought to the laboratory and bubbled under O2-free CO2 within 15 min. At the laboratory, serial dilutions were made with anaerobic dilution solution for Lachnospiraceae sp. C1.1 and propionibacterium diluent for Porphyromonadaceae sp. W3.11 (table S2). Aliquots (0.1 ml) of each dilution were injected into anaerobic bottle plates (1) containing 9 ml of LH medium (table S2). After incubation at 37°C for 7 days, isolated colonies were picked. Lachnospiraceae sp. C1.1 was picked from a bottle inoculated with a 104 dilution of rumen contents, and Porphyromonadaceae sp. W3.11 was picked from a bottle inoculated with a 103 dilution. After initial isolation, these organisms were purified by growing on anaerobic roll tubes (2) and picking isolated colonies. We performed de novo sequencing of Lachnospiraceae sp. C1.1 and Porphyromonadaceae sp. W3.11. Aliquots of liquid culture (9 and 1.5 ml, respectively) were collected by syringe and centrifuged (21,000g for 10 min at 4°C). Cell pellets were submitted to Molecular Research LP for DNA extraction, library preparation, and sequencing. After resuspending pellets in 180 µl of ATL buffer (Qiagen), DNA was extracted using the MagAttract HMW DNA Kit (Qiagen). DNA was eluted in 100 µl of AE buffer (Qiagen) and then cleaned using the DNEasy PowerClean Pro Cleanup Kit (Qiagen). DNA was then sheared using the Covaris g-TUBE (Covaris). Sequencing libraries were prepared using the SMRTbell Express Template Prep Kit 2.0 (Pacific Biosciences) and 1500 ng of the sheared and purified DNA. The SMRTbell libraries were size-selected (>6 Kb) using a BluePippin instrument (Sage Science) and 0.75% agarose gel. Libraries were then sequenced using the PacBio Sequel II (Pacific Biosciences) platform and a 30-hour movie time. Narrative Summary In these Narratives, we filtered low-quality reads using Trimmomatic (v0.36), assembled filtered reads with SPAdes (v3.15.3), and then checked completeness and contamination of the assembled genomes with CheckM (v1.0.18). Statistics for sequencing and assembly are in table S3. Using the assembled contigs (genomes), we called genes and annotated them. Protein-coding genes were called using Prodigal (v2.6.3) (3) locally or using KBase via RASTtk (v1.073), with identical results. Genes were annotated with KO IDs using KAAS (4). They were further annotated with pfam and TIGRFAM IDs using KBase and the Annotate Domains in a Genome app. We classified putative genes for hydrogenases using HydDB. Genes for 16S ribosomal RNA (rRNA) were called using RASTtk (v1.073) in KBase. The contigs (genomes) were analyzed to determine whether they belonged to new species. Taxonomy was assigned using GTDB-Tk (v1.7.0) in KBase. The identity of 16S rRNA genes to other organisms was found using EzBioCloud (5). Values of digital DNA-DNA hybridization (dDDH) were found with Type (Strain) Genome Server (6). These analyses suggest that Lachnospiraceae sp. C1.1 and Porphyromonadaceae sp. W3.11 represent novel species or genera. GTDB-Tk assigned Lachnospiracae sp. C1.1 to family Lachnospiraceae and genus NK4A144, which contains no type strains. It assigned Porphyromonadaceae sp. W3.11 to Porphyromonadaceae and genus Porphyromonas_A. Values of 16S rRNA identity and dDDH with respect to type strains were low (table S4). Although more phenotypic data are needed, available evidence supports assignment of genomes to new species or genera. Related publication Hackmann TJ, Zhang B. The phenotype and genotype of fermentative prokaryotes. Sci Adv. 2023 Sep 29;9(39):eadg8687. doi: 10.1126/sciadv.adg8687. Epub 2023 Sep 27. PMID: 37756392; PMCID: PMC10530074.

Hackmann, Timothy↗

KBase Narrative - Lachnospiraceae sp. C1.1 genome

Narratives for The phenotype and genotype of fermentative prokaryotes This is the Narrative for Porphyromonadaceae sp. W3.11. A complementary Narrative for Lachnospiraceae sp. C1.1 is available here. This is the Narrative for Lachnospiraceae sp. C1.1. A complementary Narrative for Porphyromonadaceae sp. W3.11 is available here. Background and Isolation This Narrative and its complementary Narrative contain assembly and annotation of two bacterial isolates that were isolated by our laboratory from the rumen of a Holstein heifer. All procedures with animals have been approved by University of California Davis’s Institutional Animal Care and Use Committee. Rumen contents were collected through a rumen fistula and strained through two layers of cheesecloth into a bottle. The bottle was sealed to exclude air and maintained at 39°C. Contents were brought to the laboratory and bubbled under O2-free CO2 within 15 min. At the laboratory, serial dilutions were made with anaerobic dilution solution for Lachnospiraceae sp. C1.1 and propionibacterium diluent for Porphyromonadaceae sp. W3.11 (table S2). Aliquots (0.1 ml) of each dilution were injected into anaerobic bottle plates (1) containing 9 ml of LH medium (table S2). After incubation at 37°C for 7 days, isolated colonies were picked. Lachnospiraceae sp. C1.1 was picked from a bottle inoculated with a 104 dilution of rumen contents, and Porphyromonadaceae sp. W3.11 was picked from a bottle inoculated with a 103 dilution. After initial isolation, these organisms were purified by growing on anaerobic roll tubes (2) and picking isolated colonies. We performed de novo sequencing of Lachnospiraceae sp. C1.1 and Porphyromonadaceae sp. W3.11. Aliquots of liquid culture (9 and 1.5 ml, respectively) were collected by syringe and centrifuged (21,000g for 10 min at 4°C). Cell pellets were submitted to Molecular Research LP for DNA extraction, library preparation, and sequencing. After resuspending pellets in 180 µl of ATL buffer (Qiagen), DNA was extracted using the MagAttract HMW DNA Kit (Qiagen). DNA was eluted in 100 µl of AE buffer (Qiagen) and then cleaned using the DNEasy PowerClean Pro Cleanup Kit (Qiagen). DNA was then sheared using the Covaris g-TUBE (Covaris). Sequencing libraries were prepared using the SMRTbell Express Template Prep Kit 2.0 (Pacific Biosciences) and 1500 ng of the sheared and purified DNA. The SMRTbell libraries were size-selected (>6 Kb) using a BluePippin instrument (Sage Science) and 0.75% agarose gel. Libraries were then sequenced using the PacBio Sequel II (Pacific Biosciences) platform and a 30-hour movie time. Narrative Summary In these Narratives, we filtered low-quality reads using Trimmomatic (v0.36), assembled filtered reads with SPAdes (v3.15.3), and then checked completeness and contamination of the assembled genomes with CheckM (v1.0.18). Statistics for sequencing and assembly are in table S3. Using the assembled contigs (genomes), we called genes and annotated them. Protein-coding genes were called using Prodigal (v2.6.3) (3) locally or using KBase via RASTtk (v1.073), with identical results. Genes were annotated with KO IDs using KAAS (4). They were further annotated with pfam and TIGRFAM IDs using KBase and the Annotate Domains in a Genome app. We classified putative genes for hydrogenases using HydDB. Genes for 16S ribosomal RNA (rRNA) were called using RASTtk (v1.073) in KBase. The contigs (genomes) were analyzed to determine whether they belonged to new species. Taxonomy was assigned using GTDB-Tk (v1.7.0) in KBase. The identity of 16S rRNA genes to other organisms was found using EzBioCloud (5). Values of digital DNA-DNA hybridization (dDDH) were found with Type (Strain) Genome Server (6). These analyses suggest that Lachnospiraceae sp. C1.1 and Porphyromonadaceae sp. W3.11 represent novel species or genera. GTDB-Tk assigned Lachnospiracae sp. C1.1 to family Lachnospiraceae and genus NK4A144, which contains no type strains. It assigned Porphyromonadaceae sp. W3.11 to Porphyromonadaceae and genus Porphyromonas_A. Values of 16S rRNA identity and dDDH with respect to type strains were low (table S4). Although more phenotypic data are needed, available evidence supports assignment of genomes to new species or genera. Related publication Hackmann TJ, Zhang B. The phenotype and genotype of fermentative prokaryotes. Sci Adv. 2023 Sep 29;9(39):eadg8687. doi: 10.1126/sciadv.adg8687. Epub 2023 Sep 27. PMID: 37756392; PMCID: PMC10530074.

Hackmann, Timothy↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual file system for PSDS

This is a case study. It deals with the use of a 'virtual file system' (VFS) for Boeing's UNIX-based Product Standards Data System (PSDS). One of the objectives of PSDS is to store digital standards documents. The file-storage requirements are that the files must be rapidly accessible, stored for long periods of time - as though they were paper, protected from disaster, and accumulative to about 80 billion characters (80 gigabytes). This volume of data will be approached in the first two years of the project's operation. The approach chosen is to install a hierarchical file migration system using optical disk cartridges. Files are migrated from high-performance media to lower performance optical media based on a least-frequency-used algorithm. The optical media are less expensive per character stored and are removable. Vital statistics about the removable optical disk cartridges are maintained in a database. The assembly of hardware and software acts as a single virtual file system transparent to the PSDS user. The files are copied to 'backup-and-recover' media whose vital statistics are also stored in the database. Seventeen months into operation, PSDS is storing 49 gigabytes. A number of operational and performance problems were overcome. Costs are under control. New and/or alternative uses for the VFS are being considered.

Runnels, Tyson D.↗

Assessments and Applications of Terra and Aqua MODIS On-Orbit Electronic Calibration

MODIS has 36 spectral bands located on four focal plane assemblies (FPAs), covering wavelengths from 0.41 to 14.4 micrometers. MODIS bands 1-30 collect data using photovoltaic (PV) detectors and, therefore, are referred to as the PV bands. Similarly, bands 31-36 using photoconductive (PC) detectors are referred to as the PC bands.The MODIS instrument was built with a set of on-board calibrators (OBCs) in order to track on-orbit changes of its radiometric, spatial, and spectral characteristics. In addition, an electronic calibration (ECAL) function can be used to monitor on-orbit changes of its electronic responses (gains). This is accomplished via a series of stair step signals generated by the ECAL function. These signals, in place of the FPA detector signals, are amplified and digitized just like the detector signals. Over the entire mission of both Terra and Aqua MODIS,the ECAL has been performed for the PV bands and used to assess their on-orbit performance. This paper provides an overview of MODIS on-orbit calibration activities with a focus on the PV ECAL, including its calibration process and approaches used to monitor the electronic performance. It presents the results derived and lessons learned from Terra and Aqua MODIS on-orbit ECAL. Also discussed are some of the applications performed with the information provided by the ECAL data.

Xiong, Xiaoxiong↗

Design of Test Support Hardware for Advanced Space Suits

As a member of the Space Suit Assembly Development Engineering Team, I designed and built test equipment systems to support the development of the next generation of advanced space suits. During space suit testing it is critical to supply the subject with two functions: (1) cooling to remove metabolic heat, and (2) breathing air to pressurize the space suit. The objective of my first project was to design, build, and certify an improved Space Suit Cooling System for manned testing in a 1‐G environment. This design had to be portable and supply a minimum cooling rate of 2500 BTU/hr. The Space Suit Cooling System is a robust, portable system that supports very high metabolic rates. It has a highly adjustable cool rate and is equipped with digital instrumentation to monitor the flowrate and critical temperatures. It can supply a variable water temperature down to 34 deg., and it can generate a maximum water flowrate of 2.5 LPM. My next project was to design and build a Breathing Air System that was capable of supply facility air to subjects wearing the Z‐2 space suit. The system intakes 150 PSIG breathing air and regulates it to two operating pressures: 4.3 and 8.3 PSIG. It can also provide structural capabilities at 1.5x operating pressure: 6.6 and 13.2 PSIG, respectively. It has instrumentation to monitor flowrate, as well as inlet and outlet pressures. The system has a series of relief valves to fully protect itself in case of regulator failure. Both projects followed a similar design methodology. The first task was to perform research on existing concepts to develop a sufficient background knowledge. Then mathematical models were developed to size components and simulate system performance. Next, mechanical and electrical schematics were generated and presented at Design Reviews. After the systems were approved by the suit team, all the hardware components were specified and procured. The systems were then packaged, fabricated, and thoroughly tested. The next step was to certify the equipment for manned used, which included generating a Hazard Analysis and giving a presentation to the Test Readiness Review Board. Both of these test support systems will perform critical roles in the development of next‐generation space suits. They will used on a regular basis to test the NASA's new Z‐2 Space Suit. The Space Suit Cooling System is now the primary cooling system for all advanced suit tests.

Watters, Jeffrey A.↗

Isotopic Analysis of Spent Nuclear Fuel with an Ultra-High Rate HPGe Spectrometer

A longstanding challenge is the assay of spent nuclear fuel (SNF). Determining the isotopic content of SNF requires gamma-ray spectroscopy. PNNL has developed new digital filtering and analysis techniques to produce an ultra high-rate gamma-ray spectrometer from a standard coaxial high-purity germanium (HPGe) crystal. This ~40% efficient detector has been operated for SNF measurements at a throughput of about 400k gamma-ray counts per second (kcps) at an input rate of 1.3 Mcps. Optimized filtering algorithms preserve the spectroscopic capability of the system even at these high rates. This talk will present the results of a SNF measurement with aged SNF pellets at PNNL’s Radiochemical Processing Laboratory, first results with a FPGA front end processor capable of processing the data in real time, and the development path toward a multi-element system to assay fuel assemblies.

Fast, James E.↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗

Development of Monitoring Techniques for Binderjet Additive Manufacturing of Silicon Carbide Structures

The Transformational Challenge Reactor (TCR) program is leveraging additive manufacturing (AM) technologies to fabricate nuclear components to be assembled into a fully functional microreactor core. Compared with traditional manufacturing technologies, AM technologies allow (1) observation of the manufacturing process at a much higher resolution in real-time using in situ monitoring technologies to capture the sensor signature that scientifically describes each event occurring over time and space and (2) validation of the manufacturing process quality using domain-informed data analytics techniques as a potential qualification and certification methodology for the final component. This report provides an update on the program work on binder jetting in situ process monitoring and associated data analytics results, as well as sample placement and tracking for the subsequent chemical vapor infiltration (CVI) process. Examples are provided to illustrate the progress. Elements of the Digital Thread and data management are discussed in the main document, and an extensive supplemental material section is provided detailing the Digital Platform, as well as its implementation and components. In conclusion the path forward for the next fiscal year is discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Microfluidics Sample Analyzer

Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.

Pollack, Michael G.↗

Fuel Cycle Research & Development: Technical Monthly – June 2012

Topics are: (1) MPACT Campaign - (a) Management and Integration • Coordination meetings between NE and NA-22, NA-24, and NA-82 were conducted the week of June 11th. Preparations are being made for the next MPACT working group meeting, scheduled for Aug 28-30 at Idaho Falls. In addition to covering accomplishments and discussing future plans, a site tour of INL facilities (MFC, EBR, ATR, INTEC) is being organized. (2) Accounting and Control Technologies - (a) Microcalorimetry • Now operating 256-pixel array at LANL. We are in the process of tuning detector parameters to improve and optimize performance. Preliminary measurements show approximate number of live pixels is similar to that observed previously at NIST. Continuing to study contribution to systematic error from uncertainties in tabulated gamma-ray energies. (b) Electrochemical Sensor • Testing of sensors fashioned from different precursor materials continued. SEM analysis of all used sensors has been or will be performed. (c) Lead Slowing Down Spectrometer • Ongoing perturbation calculations are providing information on the fundamental systematic error limits of LSDS. In order to achieve separating the contribution of Pu and 235U to the signal, there will need to be tight controls on systematic errors. Continuing to look into a He4 detector. Research into local construction of a He4 detector continued. We have started to apply the algorithm to test the LSDS using experimental data from previous RPI measurements. PNNL also developed a plan to address the lack of statistics in the MCNP modeling of the NGSI 64 assemblies. The ISU graduate student built and tested a fission chamber to gain experience with them. (d) Fast Neutron Imaging to Quantify Nuclear Materials • The imaging detector design was modified for each pixel to have an 8 x 8 pixel array. Quotations and purchasing process for components, including the new PSD scintillator are in progress. (e) Fast Neutron Multiplicity Analysis • The team submitted two papers to the upcoming INMM meeting that are related to the fast neutron multiplicity R&D effort. Progress was made on the project's main goal of designing a concept for a prototype fast-neutron multiplicity counter. We started laying out the outline for the final report. We have been working with our ORNL collaborators to develop a new digitizer system to support our experimental campaign planned for next year. (3) MPACT Analysis Tools - (a) Multi-isotope Process Monitor • Fuel characterization framework development continued during June. A report describing the methodologies is being completed. Kenneth Dayman, from University of Texas, spent a week at PNNL wrapping up his master's research and working on a journal submission covering that work. The target journal is the IEEE transactions on Nuclear Science; submission is planned for the end of July. A proposal to instrument H-Canyon is being prepared in conjunction with SRNL and the NNSA's NGSI program. The impact of gamma-ray spectrum counting statistics on the precision of relative radioisotope component intensities as reconstructed via Principal Component Regression (PCR) continued in June with Monte Carlo simulations of a two-component (i.e., two radioisotope) system. This work generalizes earlier studies in FY12 in which Poisson counting variations of only a single spectrum component were simulated. (b) Modeling and Simulation for Analysis of Safeguards Performance (Electrochemical) • Preliminary insights into safeguards challenges and the initial design for an electrochemical plant have been written up into an INMM paper and will be presented at the INMM Summer Meeting. Work is currently adding a new visualization capability for integrating materials accountancy with physical protection. (c) Material Control including Process Monitoring (Pattern Recognition, Sensors) • Fabrication of quartz chips continued at an external foundry. Awaiting delivery of the heat exchange manifold and chip holder. (d) MPACT System Integration and Technical Support • The initial report on cost-basis metrics for nuclear material security risk and proliferation risk was completed as scheduled. (4) Safeguards and Security by Design - (a) Used fuels storage security analysis, guidance and best practices • RFP was finalized and sent out. Awaiting response from World Institute for Nuclear Security. Coordinated with Scott Demuth on joint report • LANL milestone on best practices. Attended Nuclear Energy Institute National Nuclear Security Conference. Developed plan for soliciting input on prioritized issues for used fuel storage security. Worked on setting up a meeting with the Nuclear Regulatory Commission. Worked on FY2013 work package planning.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lightning protection of full authority digital electronic systems

Modern electronic systems are vulnerable to transient and they now provide safety critical functions such as full authority digital electronic control (FADEC) units for fly by wire aircraft. Of the traditional suppression technologies available diodes have gained the wider acceptance, however, they lack the current handling capacity to meet existing threat levels. The development of high speed fold back devices where, at a specified voltage, the off state resistance switches to a very low on state one has provided the equivalent to a semiconductor spark gap. The size of the technology enables it to be integrated into connectors of interconnection cables. To illustrate the performance the technology was developed to meet the Lightning Protection requirements for FADEC units within aeroengines. Work was also carried out to study switching behavior with the waveform 5, the 500 us, 10 kA pulse applied to cable assemblies. This test enabled all the switches in a connector to be fired simultaneously.

Crofts, David↗