The development of 3D physical program with integrated control rod calculation for HTR - 18525
The accurate calculation of the control rod worth in pebble bed high temperature gas cooled reactor(HTR) requires special treatment, because the control rod system of HTR is located outside the active zone. The current version VSOP did not calculate the control rod value directly, but use a compromise method called the Equivalent Boron Concentration (EBC). To obtain the value of the control rod with higher precision directly, this paper embedded the discontinuity factor (DF) corrected diffusion calculation into the original procedure of the VSOP. The computational procedure to obtain the DF on the side of the absorber region was optimized. While an appropriate coupling method has been developed to take into account the neutron leakage feedback, data transform and so on. The new program can achieve accurate control rod calculation and more realistic 3D power distribution during the physical calculation. The numerical results demonstrated the correctness of the new program preliminarily. (authors)