Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Contribution of Nonsynchronous Generation to Bulk System Frequency Response

There is general concern in the power system industry regarding the degradation of frequency response due to various factors, such as the withdrawal of primary or governor response shortly after an event, the lack of in-service governors on conventional generation, and the unknown and changing nature of load frequency characteristics. Large penetrations of nonsynchronous or inverter-based generation (e.g., wind and solar photovoltaic) further contribute to the concerns. This paper reports on frequency stability research designed to explore the impact of high penetrations of inverter-based generation on the frequency response of a large interconnected grid as well as the potential contribution of those nonsynchronous resources to maintaining frequency stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Transient Simulation Algorithms for Evaluation of Large-Scale Extreme Fast Charging Systems (Distribution Grid Models)

The distribution and transmission grids are observing an increased penetration of power electronics in loads and generations. For example, there is increasing interest in integrating in extreme fast charging (XFC) systems for fast charging of electrical vehicles. As these systems are integrated, developing high-fidelity electromagnetic transient model of XFC systems in distribution grids and evaluating their interactions with the power grid would be of significant interest. This model will be utilized for design of XFC systems, to identify upgrades in distribution and/or transmission grids, for planning purposes by transmission planners or operators or owners, among others. It can also be utilized in operations for improved reliable performance of the grid and/or XFC station. The challenge with simulating these models is the high computational complexity introduced by the large number of states present in the system and the time-step needed to simulate the system. In this paper, advanced simulations algorithms are applied to reduce the computational complexity of simulating large-scale XFC systems. The algorithms include numerical stiffness-based segregation, time constant-based segregation, clustering and aggregation on differential algebraic equations (DAEs), and multi-order integration approaches. While the first three algorithms split the matrix that needs to be inverted from a large matrix to much smaller matrices, the final algorithm reduces the computational burden of applying higher-order integration approaches in the complete system. The comparison made in the previous sentence is with respect to use of homogeneous integration approaches used in conventional electromagnetic transient simulators like power systems computer aided design (PSCAD). The approaches mentioned here have resulted in speed-up of 36x in the simulation of a single distribution system with 15 XFCs.

Debnath, Suman↗

Wave resource spatial and temporal variability dependence on WEC size

As the wave energy sector grows and looks to the Blue Economy for commercialization opportunities, there is a distinct and pressing need to clearly understand and quantify the coupled impacts of wave energy converter (WEC) size and wave resource characteristics on the annual energy production, spatial variability and temporal variability. Utilizing generic frequency domain representations of the Oscilla Power Triton WEC and spectral wave conditions at PacWave (Oregon), Los Angeles (California) and WETS (Hawaii), a series of interesting results emerge. Firstly, the ‘optimal’ WEC size, from an energy standpoint, is fundamentally dependent on the frequency distribution of the incoming wave variance density spectrum. Secondly, and from a seasonality perspective, the seasonal WEC energy generation doesn’t necessarily follow the seasonal distribution of gross wave power. Finally, from an hourly power variability perspective, a reduction in WEC size generally decreases variability. However, for each of the locations investigated, there appears to be a WEC size threshold; a threshold where further reducing WEC size results in increased power variability.

16 TIDAL AND WAVE POWER↗

Wave Resource Spatial and Temporal Variability Dependence on WEC Size

As the wave energy sector grows and looks to the Blue Economy for commercialization opportunities, there is a distinct and pressing need to clearly understand and quantify the coupled impacts of wave energy converter (WEC) size and wave resource characteristics on the annual energy production, spatial variability and temporal variability. Utilizing generic frequency domain representations of the Oscilla Power Triton WEC and spectral wave conditions at PacWave (Oregon), Los Angeles (California) and WETS (Hawaii), a series of interesting results emerge. Firstly, the 'optimal' WEC size, from an energy standpoint, is fundamentally dependent on the frequency distribution of the incoming wave variance density spectrum. Secondly, and from a seasonality perspective, the seasonal WEC energy generation doesn't necessarily follow the seasonal distribution of gross wave power. Finally, from an hourly power variability perspective, a reduction in WEC size generally decreases variability. However, for each of the locations investigated, there appears to be a WEC size threshold; a threshold where further reducing WEC size results in increased power variability.

blue economy↗

A Data-Driven Framework for Residential Electric Vehicle Charging Load Profile Generation

Residential electric vehicle charging load profile is indispensable to achieve reliable control strategies for mitigating negative effects on power distribution system due to emerging electrified transportation. This paper introduces a data-driven framework of charging load profile generation for residential plug-in electric vehicles. Real world historical residential charging behavior data is utilized to construct empirical charging decision making model by using machine learning algorithm. A multiple channels method with kernel density estimation is proposed to construct probability density functions for estimating charging duration based on parking duration. A generation algorithm considering parking time and travel demand dependency is introduced to generate residential charging behaviors. This framework is extensible to generate various charging load profiles and simulate varied residential charging scenarios under different number of households and charging rates. This will be crucial for designing and validating residential charging control strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

behind-the-meter↗

Requirements for Robust DERMS Control and Cyber Attack Scenarios

A Distribution Management System (DMS) is responsible for monitoring and maintaining the health of a distribution grid. Common DMS applications include fault location isolation and service restoration, on-line power flow (OLPF), volt/VAR optimization (VVO), and switch order management. These systems were developed primarily in the area of top-down, unidirectional power flow, with large centralized generating plants moving electricity through the transmission grid and into the distribution grid from and thence to consumers. The recent and ongoing addition of distributed energy resources (DER) to the grid, including rooftop and community solar and wind, means that power is now flowing into the distribution grid from the edge, which complicates the functioning of the DMS. To ameliorate this problem, DMS use distributed energy resource management systems (DERMS) to control DER such as solar inverters. DERMS comprise software management tools that allow management and near real-time control of an array of DER. DERMS control devices and grid services including smart inverters, capacitor banks, on-load tap changes, voltage regulators, and customer loads.

14 SOLAR ENERGY↗

On the Low Risk of SSR in Type III Wind Turbines Operating in Grid-Forming Control: Preprint

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar +: Clean Energy Strategies for the Sunshine State (Final Technical Report (FTR) of the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR))

This reports on a four-year effort to provide foundational research, analysis, strategies and assistance to help Florida, and other states that might learn from this work, to grow solar energy in conjunction with other distributed energy resources by addressing and overcoming existing barriers, and in way that delivers increased value. The start of this effort coincided with an inflection point of sorts into a new dawn for solar energy in Florida, where the Sunshine state’s national ranking in total installed solar, according to the Solar Energy Industries Association (SEIA), has rose from 13th to 4th. Florida has now become the national leader in annual utility-scale solar growth as dozens of large plants have come online. Also, during this time, Florida utilities have expressed a strong and growing interest in understanding the role of energy storage and how to best plan for and deploy this unique resource as part of strategies to grow solar. The utility-scale solar growth experienced has been fueled by the economics of solar cost-parity with natural gas combined cycle plants and Florida Public Service Commission’s (PSC) approval of cost-recovery for the Investor-Owned Utilities (IOU’s), primarily through the Solar Base Rate Adjustment (SoBRA) mechanism. This has led to gigawatts (GW’s) of rate-based solar capacity additions over several years, along with fairly significant amounts of energy storage. Meanwhile, municipal electric utilities, which, collectively, are the third largest source of power in the state, have been increasing solar considerably through power purchase agreements (PPA’s) and are on track to have close to 1 GW of grid-connected solar by 2024. Florida’s municipal utilities and the Florida Municipal Electric Association (FMEA) have been key partners in the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR), formed to carry out this effort. The six largest of these have been Core Team utilities, engaging throughout the project in weekly calls, discussions, and project direction, participating in and hosting workshops and benefiting from technical assistance in several areas.

14 SOLAR ENERGY↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Smart Inverter Utility Experience in Hawaii

This publication on utility experience with advanced inverters is a part of a tutorial at the 2019 IEEE Power and Energy Society General Meeting titled 'Smart Inverters for Distributed Generators - Utility Applications and Experiences'. It describes lessons utilities can take from the experience of Hawaiian Electric with deployment of advanced inverter functionality. Hawaiian Electric is one of the leading U.S. utilities in terms of deployment of distributed solar photovoltaic systems and advanced inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Stochastic Generation Capacity Expansion Planning with Approximate Dynamic Programming

Failing to consider the many long-term uncertainties that affect the performance of a power generation portfolio can result in suboptimal generation expansion plans. Further, traditional deterministic approaches can omit flexible plans that are able to adapt to future events. In this paper, we explore the use of approximate dynamic programming (ADP) to create forward-looking generation expansion plans. A case study is included with three sequential decision periods; three generation technologies; and four uncertainties: demand growth, natural gas prices, renewable portfolio standards, and the adoption of customer-driven solar generation. The flexible plans found through ADP show a 3 % reduction in total expected cost when compared to myopic planning heuristics while circumventing the computational burdens that accompany high-dimensional dynamic programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗