Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine

Purpose: The objective of the present work was to propose a design of a secondary multileaf collimator (MLC) for a telecobalt machine and optimize its design features through Monte Carlo simulation. Methods: The proposed MLC design consists of 72 leaves (36 leaf pairs) with additional jaws perpendicular to leaf motion having the capability of shaping a maximum square field size of 35 Multiplication-Sign 35 cm{sup 2}. The projected widths at isocenter of each of the central 34 leaf pairs and 2 peripheral leaf pairs are 10 and 5 mm, respectively. The ends of the leaves and the x-jaws were optimized to obtain acceptable values of dosimetric and leakage parameters. Monte Carlo N-Particle code was used for generating beam profiles and depth dose curves and estimating the leakage radiation through the MLC. A water phantom of dimension 50 Multiplication-Sign 50 Multiplication-Sign 40 cm{sup 3} with an array of voxels (4 Multiplication-Sign 0.3 Multiplication-Sign 0.6 cm{sup 3}= 0.72 cm{sup 3}) was used for the study of dosimetric and leakage characteristics of the MLC. Output files generated for beam profiles were exported to the PTW radiation field analyzer software through locally developed software for analysis of beam profiles in order to evaluate radiation field width, beam flatness, symmetry, and beam penumbra. Results: The optimized version of the MLC can define radiation fields of up to 35 Multiplication-Sign 35 cm{sup 2} within the prescribed tolerance values of 2 mm. The flatness and symmetry were found to be well within the acceptable tolerance value of 3%. The penumbra for a 10 Multiplication-Sign 10 cm{sup 2} field size is 10.7 mm which is less than the generally acceptable value of 12 mm for a telecobalt machine. The maximum and average radiation leakage through the MLC were found to be 0.74% and 0.41% which are well below the International Electrotechnical Commission recommended tolerance values of 2% and 0.75%, respectively. The maximum leakage through the leaf ends in closed condition was observed to be 8.6% which is less than the values reported for other MLCs designed for medical linear accelerators. Conclusions: It is concluded that dosimetric parameters and the leakage radiation of the optimized secondary MLC design are well below their recommended tolerance values. The optimized design of the proposed MLC can be integrated into a telecobalt machine by replacing the existing adjustable secondary collimator for conformal radiotherapy treatment of cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-274: Radiation Therapy with Very High-Energy Electron (VHEE) Beams in the Presence of Metal Implants

Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned using a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from RaySearch laboratories; B Hardemark and E Hynning are employees of RaySearch.

60 APPLIED LIFE SCIENCES↗

MO-E-18C-02: Hands-On Monte Carlo Project Assignment as a Method to Teach Radiation Physics

Purpose: To present a hands-on project on Monte Carlo methods (MC) recently added to the curriculum and to discuss the students' appreciation. Methods: Since 2012, a 1.5 hour lecture dedicated to MC fundamentals follows the detailed presentation of photon and electron interactions. Students also program all sampling steps (interaction length and type, scattering angle, energy deposit) of a MC photon transport code. A handout structured in a step-by-step fashion guides student in conducting consistency checks. For extra points, students can code a fully working MC simulation, that simulates a dose distribution for 50 keV photons. A kerma approximation to dose deposition is assumed. A survey was conducted to which 10 out of the 14 attending students responded. It compared MC knowledge prior to and after the project, questioned the usefulness of radiation physics teaching through MC and surveyed possible project improvements. Results: According to the survey, 76% of students had no or a basic knowledge of MC methods before the class and 65% estimate to have a good to very good understanding of MC methods after attending the class. 80% of students feel that the MC project helped them significantly to understand simulations of dose distributions. On average, students dedicated 12.5 hours to the project and appreciated the balance between hand-holding and questions/implications. Conclusion: A lecture on MC methods with a hands-on MC programming project requiring about 14 hours was added to the graduate study curriculum since 2012. MC methods produce “gold standard” dose distributions and slowly enter routine clinical work and a fundamental understanding of MC methods should be a requirement for future students. Overall, the lecture and project helped students relate crosssections to dose depositions and presented numerical sampling methods behind the simulation of these dose distributions. Research funding from governments of Canada and Quebec. PP acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

07 ISOTOPE AND RADIATION SOURCES↗

On the consistency of Monte Carlo track structure DNA damage simulations

Purpose: Monte Carlo track structures (MCTS) simulations have been recognized as useful tools for radiobiological modeling. However, the authors noticed several issues regarding the consistency of reported data. Therefore, in this work, they analyze the impact of various user defined parameters on simulated direct DNA damage yields. In addition, they draw attention to discrepancies in published literature in DNA strand break (SB) yields and selected methodologies. Methods: The MCTS code Geant4-DNA was used to compare radial dose profiles in a nanometer-scale region of interest (ROI) for photon sources of varying sizes and energies. Then, electron tracks of 0.28 keV–220 keV were superimposed on a geometric DNA model composed of 2.7 × 10{sup 6} nucleosomes, and SBs were simulated according to four definitions based on energy deposits or energy transfers in DNA strand targets compared to a threshold energy E{sub TH}. The SB frequencies and complexities in nucleosomes as a function of incident electron energies were obtained. SBs were classified into higher order clusters such as single and double strand breaks (SSBs and DSBs) based on inter-SB distances and on the number of affected strands. Results: Comparisons of different nonuniform dose distributions lacking charged particle equilibrium may lead to erroneous conclusions regarding the effect of energy on relative biological effectiveness. The energy transfer-based SB definitions give similar SB yields as the one based on energy deposit when E{sub TH} ≈ 10.79 eV, but deviate significantly for higher E{sub TH} values. Between 30 and 40 nucleosomes/Gy show at least one SB in the ROI. The number of nucleosomes that present a complex damage pattern of more than 2 SBs and the degree of complexity of the damage in these nucleosomes diminish as the incident electron energy increases. DNA damage classification into SSB and DSB is highly dependent on the definitions of these higher order structures and their implementations. The authors’ show that, for the four studied models, different yields are expected by up to 54% for SSBs and by up to 32% for DSBs, as a function of the incident electrons energy and of the models being compared. Conclusions: MCTS simulations allow to compare direct DNA damage types and complexities induced by ionizing radiation. However, simulation results depend to a large degree on user-defined parameters, definitions, and algorithms such as: DNA model, dose distribution, SB definition, and the DNA damage clustering algorithm. These interdependencies should be well controlled during the simulations and explicitly reported when comparing results to experiments or calculations.

60 APPLIED LIFE SCIENCES↗

SU-E-J-69: Iterative Deconvolution of the Initial Photon Fluence for EPID Dosimetry: A Monte Carlo Based Study

Purpose: Developing a fast and accurate calculation model to reconstruct the applied photon fluence from an external photon radiation therapy treatment based on an image recorded by an electronic portal image device (EPID). Methods: To reconstruct the initial photon fluence the 2D EPID image was corrected for scatter from the patient/phantom and EPID to generate the transmitted primary photon fluence. This was done by an iterative deconvolution using precalculated point spread functions (PSF). The transmitted primary photon fluence was then backprojected through the patient/phantom geometry considering linear attenuation to receive the initial photon fluence applied for the treatment.The calculation model was verified using Monte Carlo simulations performed with the EGSnrc code system. EPID images were produced by calculating the dose deposition in the EPID from a 6 MV photon beam irradiating a water phantom with air and bone inhomogeneities and the ICRP anthropomorphic voxel phantom. Results: The initial photon fluence was reconstructed using a single PSF and position dependent PSFs which depend on the radiological thickness of the irradiated object. Appling position dependent point spread functions the mean uncertainty of the reconstructed initial photon fluence could be reduced from 1.13 % to 0.13 %. Conclusion: This study presents a calculation model for fluence reconstruction from EPID images. The{sup Result} show a clear advantage when position dependent PSF are used for the iterative reconstruction. The basic work of a reconstruction method was established and further evaluations must be made in an experimental study.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-07: Alanine and Monte Carlo Determined Beam Quality Corrections for Nonstandard Fields of the Varian TrueBeam Accelerator

Purpose: To determine beam quality correction factors for flattened and unflattened beams of the Varian TrueBeam™ accelerator using alanine measurements and Monte Carlo calculations. Methods: Measurements were performed using L-α-alanine pellets encased in Virtual Water™ paddles. These were irradiated in liquid water using various field sizes of the 6MV and 10MV beam energies of the TrueBeam™, with both flattening-filter-free (FFF) and flattened beam modes. Measurements were also performed in a 10×10 cm{sup 2} {sup 60}Co field. Pellets were read out by the National Physical Laboratory (NPL, Teddington, UK) using electron paramagnetic resonance (EPR) spectrometry, and results were corrected for energy dependence using graphite calorimetry. Beam quality correction factors (k{sub Q}, k{sub Q}msr,Q, and k{sub Q}clin,Q{sub msr}) were determined for three ionization chambers: an Exradin A12 Farmer-type chamber, an Exradin A1SL scanning chamber, and an Exradin A26 microchamber. All chambers were modeled in the egs-chamber user code of EGSnrc. Sources were created using Varian-supplied IAEA-compliant phase spaces and the BEAMnrc user code, and were validated by comparing measured and simulated dose profiles. Results: Measured and calculated k{sub Q} values agreed within uncertainties, showing the chamber models to be reliable. A comparison of measured and calculated k{sub Q}msr,Q results with TG-51-based values showed that TG-51 adequately accounts for variations in beam quality between flattened and unflattened 10×10 cm{sup 2} fields. Small field corrections, k{sub Q}clin,Q{sub msr}, were determined to be up to 5%, referenced to a 10×10 cm{sup 2} field of the same energy and mode. Conclusion: Beam quality corrections were determined for several beam energies of the TrueBeam™ accelerator using Monte Carlo calculations and were validated using measurements with alanine. Values of k{sub Q} determined using TG-51 were found to be adequate for FFF reference fields. However, small field corrections are necessary for both flattened and unflattened beams to ensure greater treatment planning accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic Radiation Source Generation with the ISC Package: Data Comparisons and Benchmarking

The characterization of radioactive emissions from unstable isotopes (intrinsic radiation) is necessary for shielding and radiological-dose calculations from radioactive materials. While most radiation transport codes, e.g., MCNP [X-5 Monte Carlo Team, 2003], provide the capability to input user prescribed source definitions, such as radioactive emissions, they do not provide the capability to calculate the correct radioactive-source definition given the material compositions. Special modifications to MCNP have been developed in the past to allow the user to specify an intrinsic source, but these modification have not been implemented into the primary source base [Estes et al., 1988]. To facilitate the description of the intrinsic radiation source from a material with a specific composition, the Intrinsic Source Constructor library (LIBISC) and MCNP Intrinsic Source Constructor (MISC) utility have been written. The combination of LIBISC and MISC will be herein referred to as the ISC package. LIBISC is a statically linkable C++ library that provides the necessary functionality to construct the intrinsic-radiation source generated by a material. Furthermore, LIBISC provides the ability use different particle-emission databases, radioactive-decay databases, and natural-abundance databases allowing the user flexibility in the specification of the source, if one database is preferred over others. LIBISC also provides functionality for aging materials and producing a thick-target bremsstrahlung photon source approximation from the electron emissions. The MISC utility links to LIBISC and facilitates the description of intrinsic-radiation sources into a format directly usable with the MCNP transport code. Through a series of input keywords and arguments the MISC user can specify the material, age the material if desired, and produce a source description of the radioactive emissions from the material in an MCNP readable format. Further details of using the MISC utility can be obtained from the user guide [Solomon, 2012]. The remainder of this report presents a discussion of the databases available to LIBISC and MISC, a discussion of the models employed by LIBISC, a comparison of the thick-target bremsstrahlung model employed, a benchmark comparison to plutonium and depleted-uranium spheres, and a comparison of the available particle-emission databases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Worst Case Sabotage Consequence Modeling for Advanced Reactors

Under proposed rulemaking by the United States Nuclear Regulatory Commission, advanced reactor licensees may qualify for a reduction in onsite responders if the consequences from a sabotage attack do not exceed 25 rem at the reactor site boundary 2 hours after a release occurs. This work presents a preliminary assessment of the feasibility of meeting the 25 rem at the site boundary criteria. Using advanced reactor radionuclide inventories radiological release estimates created by collaborators at Oak Ridge National Laboratory, the MACCS consequence analysis code was used to investigate the distance at the dose from hypothetical sabotage events reaches 25 rem for different advanced reactor technologies. It was found that the distance to 25 rem depended heavily on sampled weather conditions and sabotage release fractions, and further refinement of release fractions and MACCS modeling parameters is recommended.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Containment margins in FFTF for postulated failure of in-vessel post-accident heat removal

This study was performed to complete the assessment of potential melt-through consequences for the postulated failure of post-accident heat removal following a hypothetical core disruptive accident (HCDA) in the FFTF. The SPRAY, SOFIRE, CACECO, HAA-3B, and COMRADEX codes were used to determine potential site boundary radiation doses. Parametric comparisons were made to evaluate the effects of natural hydrogen-oxygen recombination, reactor cavity liner failures and containment coolers. Containment pressure relief, vent/purge options, and the effects of exhaust filtration were also included in the study. The potential site boundary radiation exposures for all options considered were within 10 CFR 100 guideline values.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-37: A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

Purpose: Recent developments in radiation therapy have been focused on applications of charged particles, especially protons. Over the years several dose calculation methods have been proposed in proton therapy. A common characteristic of all these methods is their extensive computational burden. In the current study we present for the first time, to our best knowledge, a GPU-based PBA for proton dose calculations in Matlab. Methods: In the current study we employed an analytical expression for the protons depth dose distribution. The central-axis term is taken from the broad-beam central-axis depth dose in water modified by an inverse square correction while the distribution of the off-axis term was considered Gaussian. The serial code was implemented in MATLAB and was launched on a desktop with a quad core Intel Xeon X5550 at 2.67GHz with 8 GB of RAM. For the parallelization on the GPU, the parallel computing toolbox was employed and the code was launched on a GTX 770 with Kepler architecture. The performance comparison was established on the speedup factors. Results: The performance of the GPU code was evaluated for three different energies: low (50 MeV), medium (100 MeV) and high (150 MeV). Four square fields were selected for each energy, and the dose calculations were performed with both the serial and parallel codes for a homogeneous water phantom with size 300×300×300 mm3. The resolution of the PBs was set to 1.0 mm. The maximum speedup of ∼127 was achieved for the highest energy and the largest field size. Conclusion: A GPU-based PB algorithm for proton dose calculations in Matlab was presented. A maximum speedup of ∼127 was achieved. Future directions of the current work include extension of our method for dose calculation in heterogeneous phantoms.

60 APPLIED LIFE SCIENCES↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 03: Energy dependence of a clinical probe-format calorimeter and its pertinence to absolute photon and electron beam dosimetry

Purpose: To evaluate the intrinsic and absorbed-dose energy dependence of a small-scale graphite calorimeter probe (GPC) developed for use as a routine clinical dosimeter. The influence of charge deposition on the response of the GPC was also assessed by performing absolute dosimetry in clinical linac-based electron beams. Methods: Intrinsic energy dependence was determined by performing constant-temperature calorimetry dose measurements in a water-equivalent solid phantom, under otherwise reference conditions, in five high-energy photon (63.5 < %dd(10){sub X} < 76.3), and five electron (2.3 cm < R{sub 50} < 8.3 cm) beams. Reference dosimetry was performed for all beams in question using an Exradin A19 ion chamber with a calibration traceable to national standards. The absorbed-dose component of the overall energy dependence was calculated using the EGSnrc egs-chamber user code. Results: A total of 72 measurements were performed with the GPC, resulting in a standard error on the mean absorbed dose of better than 0.3 % for all ten beams. For both the photon and electron beams, no statistically-significant energy dependence was observed experimentally. Peak-to-peak, variations in the relative response of the GPC across all beam qualities of a given radiation type were on the order of 1 %. No effects, either transient or permanent, were attributable to the charge deposited by the electron beams. Conclusions: The GPC’s apparent energy-independence, combined with its well-established linearity and dose rate independence, make it a potentially useful dosimetry system capable measuring photon and electron doses in absolute terms at the clinical level.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Modeling for Harborview Research and Training Facility

The Harborview Research and Training (R&T) Facility at the University of Washington (UW) was accidently contaminated from a breached sealed source of Cesium-137. The release occurred during removal of the sealed source from its holder within a portable hot cell in the loading dock area near room 220. The loading dock and northeast corner of the building above the ground floor were impacted by the release, whereas the remaining portions of the R&T Facility were minimally affected. Detailed descriptions of the R&T Facility and the affected area/rooms are included in Section 2. The RESRAD Team in the Environmental Science Division of Argonne National Laboratory visited the site on August 12, 2019, and interviewed the R&T Facility building manager and staff working in the building at that time. Site- and building-specific data were collected including building floor plan CAD drawings, building occupants’ working hours, contaminated rooms photos and their dimensions, building air exchange rates, building materials and “curtain wall” details, and so forth. These data are being used in the dose modeling for potential occupants of the building after it is remediated. The dose modeling was performed using the RESRAD-BUILD computer code, which is designed for the evaluation of radiologically contaminated buildings (Yu et al. 2003). Two hypothetical building occupants of the Harborview R&T Facility were evaluated: a researcher occupying room 726 (a research laboratory on the seventh floor) and a custodian occupying room 220 (loading dock and trash compactor room with a rollup door). A maintenance worker that will be spending less time in impacted areas was not modeled because it will be bounded by other two hypothetical building occupants modeled. A summary description of the RESRAD-BUILD is provided in Appendix A, and the modeling of potential doses to a researcher and a custodian is described in detail in Section 3. A summary and a discussion of the dose modeling results are included in Section 4. The parameters used in the RESRAD-BUILD modeling are included in Appendix B. This report documents the dose modeling results; it does not describe measurements of the actual radioactivity levels at the Harborview R&T Facility, nor does it set any expectation for the actual final radioactivity levels. The radiation doses presented are modeling results based on the generic screening values of Cs-137 and several conservative assumptions and are meant only to assist in decision making regarding decontamination of the Harborview R&T Facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

A thermodynamics-based damage model for the non-linear mechanical behavior of SiC/SiC ceramic matrix composites in irradiation and thermal environments

A damage model is developed and validated with experimental data for the non-linear mechanical behavior of SiC/SiC composite materials in nuclear applications. Cyclic thermal and mechanical loading associated with neutron irradiation effects of these composites leads to wide-spread and progressive micro-cracking that leads to loss of thermal conductivity and further enhancement of thermo-mechanical damage. A physics-based model of wide-spread micro-cracking is developed within the thermodynamic framework of continuum damage mechanics. Evolution equations for damage parameters that describe the growth of continuum damage are developed, where the material variables are obtained from experiments. The model novelty is in coupling mechanical, thermal, and irradiation damage through a consistent thermodynamic framework, including loss of thermal conductivity due to the evolution of mechanically induced micro-cracks. A number of thermo-mechanical experiments were conducted to confirm model assumptions. The model is shown to be validated with out-of-pile experiments, and then implemented using commercial finite element code COMSOL to the fuel cladding problem with normal and high radiation dose cases.

Materials Science↗

Evaluation of Dose Coefficients Implemented in MACCS

A variety of dose conversion factor files (DCF files) have been supplied for use with the MACCS code since it was initially released. For MACCS 4.2, the MACCS DCF files have been updated to include coefficients used in the computation of acute skin doses from within the MACCS software to increase functionality and to add a pseudo-organ to represent the total effective dose equivalent (TEDE) (as defined in 10 CFR 20.1003) based on International Commission on Radiological Protection (ICRP) Publication 30. This report provides a description of how these changes have been implemented and a summary of the various DCF files supplied with MACCS 4.2. The report also provides supplemental discussions to assist the reader in understanding the technical basis for the MACCS DCFs. These supplemental discussions include a summary of basic dosimetry modeling concepts and a brief review of the Federal Guidance Reports (FGRs) upon which MACCS dose coefficients have historically been based.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-171: Characterization of the New Xoft Axxent Electronic Brachytherapy Source Using PRESAGE Dosimeters

Purpose: To characterize the Xoft Axxent electronic brachytherapy source using PRESAGE™ dosimeters to obtain independent confirmation of TG-43U1 dosimetry values from previous studies and ascertain its reproducibility in HDR brachytherapy. Methods: PRESAGE™ dosimeters are solid, polyurethane-based dosimeters doped with radiochromic leucodyes that produce a linear optical-density response when exposed to radiation. Eight 1-kg dosimeters were scanned prior to irradiation on an optical-CT scanner to eliminate background signal and any optical imperfections from each dosimeter. To quantify potential imaging artifacts due to oversaturated responses in the immediate range of the source, half of the eight dosimeters were cast with a smaller channel diameter of 5.4 mm, and the other half were cast with a larger channel diameter of 15mm. During irradiation, the catheters were placed in the center of each channel. Catheters fit the 5.4mm diameters channels whereas polyurethane plugs were inserted into the larger channels to create a sturdy, immobile catheter which allowed uniform dose distributions. Two dosimeters of each 5.4mm and 15mm were irradiated at either 1517.3 cGy or 2017.5 cGy. Post-irradiation scans were performed within 48 hours of irradiation. A 3D reconstruction based on subtraction of these two images and the relative dose measurements were made using in-house software. Results: Comparing measured radial dose rates with previous results revealed smaller percent errors when PRESAGE™ irradiations were at lower maximum dose. The dosimeters showed small deviations in radial dose function, g{sub p} (r), from previous studies. Among the dosimeters irradiated at 1517.3 cGy, the g{sub p}(r) compared to previous studies fluctuated from 0.0043 to 0.3922. This suggests small fluctuations can drastically change radial dose calculations. Conclusion: The subtraction of pre-irradiation and post-irradiation scans of PRESAGE™ dosimeters using an optical-CT scanner shows promising results in determining 3D dosimetry for Xoft Axxent devices; however, further research is recommended. NIH Grant#: 5-U24-CA081647-13; ROI Grant#: 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

SU-E-T-139: Automated Daily EPID Exit Dose Analysis Uncovers Treatment Variations

Purpose: To evaluate a fully automated EPID exit dose system for its ability to detect daily treatment deviations including patient setup, delivery, and anatomy changes. Methods: PerFRACTION (Sun Nuclear Corporation) software is a system that uses integrated EPID images taken during patient treatment and automatically pulled from the Aria database and analyzed based on user-defined comparisons. This was used to monitor 20 plans consisting of a total of 859 fields for 18 patients, for a total of 251 fractions. Nine VMAT, 5 IMRT, and 6 3D plans were monitored. The Gamma analysis was performed for each field within a plan, comparing the first fraction against each of the other fractions in each treatment course. A 2% dose difference, 1 mm distance-to-agreement, and 10% dose threshold was used. These tight tolerances were chosen to achieve a high sensitivity to treatment variations. The field passed if 93% of the pixels had a Gamma of 1 or less. Results: Twenty-nine percent of the fields failed. The average plan passing rate was 92.5%.The average 3D plan passing rate was less than for VMAT or IMRT, 84%, vs. an average of 96.2%. When fields failed, an investigation revealed changes in patient anatomy or setup variations, often also leading to variations of transmission through immobilization devices. Conclusion: PerFRACTION is a fully automated system for determining daily changes in dose transmission through the patient that requires no effort other than for the imager panel to be deployed during treatment. A surprising number of fields failed the analysis and can be attributed to important treatment variations that would otherwise not be appreciated. Further study of inter-fraction treatment variations is possible and warranted. Sun Nuclear Corporation provided a license to the software described.

60 APPLIED LIFE SCIENCES↗