Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Development and testing of the ultraviolet spectrometer for the Mariner Mars 1971 spacecraft

The Mariner Mars 1971 ultraviolet spectrometer is an Ebert-Fastie type of the same basic design as the Mariner Mars 1969 instrument. Light enters the instrument and is split into component wavelengths by a scanning reflection diffraction grating. Two monochrometer exit slits allow the use of two independent photomultiplier tube sensors. Channel 1 has a spectral range of 1100 to 1692 A with a fixed gain, while Channel 2 has a spectral range of 1450 to 3528 A with an automatic step gain control, providing a dynamic range over the expected atmosphere and surface brightness of Mars. The scientific objectives, basic operation, design, testing, and calibration for the Mariner Mars 1971 ultraviolet spectrometer are described. The design discussion includes those modifications that were necessary to extend the lifetime of the instrument in order to accomplish the Mariner Mars 1971 mission objectives.

Farrar, J. W.↗

Partial Reflection Spaced Antenna Wind Measurements

The nature of partially reflecting (PR) irregularities is briefly reviewed and the techniques used in the PR spaced antenna method are discussed. The radars addressed use frequencies in the 2 to 6 MHz range operate in a pulse mode at vertical incidence. Radar system parameters including receiver dynamic range, coherent and incoherent detection, and post detection filtering are examined. Finally, data system parameters and real time analysis techniques are discussed.

Fraser, G. J.↗

Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry

We report an atmospheric-pressure solution-cathode glow discharge (SCGD) has been evaluated as an ion source for atomic, molecular, and ambient desorption/ionization mass spectrometry. The SCGD consists of a direct-current plasma, supported in the ambient air in the absence of gas flows, and sustained upon the surface of a flowing liquid cathode. Analytes introduced in the flowing liquid, as an ambient gas, or as a solid held near the plasma are vaporized and ionized by interactions within or near the discharge. Introduction of acidic solutions containing metal salts produced bare elemental ions as well as H 2 O, OH - and NO 3 - adducts. Detection limits for these elemental species ranged from 0.1 to 4 ppb, working curves spanned more than 4 orders of linear dynamic range, and precision varied between 5 and 16% relative standard deviation. Small organic molecules were also efficiently ionized from solution, and both the intact molecular ion and fragments were observed in the resulting SCGD mass spectra. Fragmentation of molecular species was found to be tunable; high discharge currents led to harder ionization, while low discharge currents produced stronger molecular-ion signals. Ambient gases and solids, desorbed by the plasma from a glass probe, were also readily ionized by the SCGD. Indeed, strong analyte signals were obtained from solid samples placed at least 2 cm from the plasma. These findings indicate that the SCGD might be useful also for ambient desorption/ionization mass spectrometry. In conclusion, combined with earlier results that showed the SCGD is useful for ionization of labile biomolecules, the results here indicate that the SCGD is a highly versatile ion source capable of providing both elemental and molecular mass-spectral information.

74 ATOMIC AND MOLECULAR PHYSICS↗

Charge Dependence of Local Hydration Dynamics in Poly(Acrylic Acid) Solutions

Localized measurements of hydration dynamics surrounding poly(acrylic acid) (pAA) chains are executed using Overhauser dynamic nuclear polarization relaxometry to determine the role of polymer protonation state on the polymer solvation environment. Alterations in polymer concentration and solution pH uncovered three different regimes of local water dynamics ranging from bulk-water-like to subdued water diffusivity. These experiments, combined with molecular dynamics simulations, reveal that the presence of deprotonated carboxylic acid groups promotes a hydrophilic local environment and extended polymer chain configurations that together incentivize the incorporation of bulk-like water near the polymer. This results in a stretched polymer conformation that leads to faster observed hydration dynamics in the local hydration environment. Meanwhile, protonated carboxylic acid groups are expected to engage in intrapolymer hydrogen bonding between monomer groups, resulting in a more collapsed conformation and slower observed hydration dynamics. The importance of the carboxylic acid groups on mediating hydration behavior is further illustrated by their role in dictating the solvation environment around poly(acrylic acid-stat-(poly(ethylene glycol) methyl ether acrylate) (p(AA-stat-PEGMEA)) copolymers with varying monomer ratios. Furthermore, these local hydration measurements establish a connection between local water dynamics and polymer chain conformation and may provide additional molecular perspective into poly(acrylic acid)’s classification as a superabsorbent polymer.

Conformation↗

Two-color pyrometry system to eliminate optical errors for spatially resolved measurements in flames

Two color (2C) pyrometry has long been used to measure flame temperature and soot concentration from radiative emission in flames. While 2C pyrometry is not an absolute measurement in non-axisymmetric flames (such as diesel spray combustion) it is a desirable diagnostic for semi-quantitative or qualitative measurements since it requires minimal optical access and can utilize high-speed imaging to attain exceptional temporal and spatial resolution. In this work, an improved optical configuration of 2C pyrometry is presented that 1) eliminates optical errors inherent in other designs, and 2) uses off-the-shelf optics and a single camera . In particular, this work analyzes the impact of parallax and path length differences on the 2C pyrometry measurement and exemplifies how the present design eliminates associated errors by design rather than in post-processing. Finally, the theoretical range of measurements were generated a priori and overlaid with experimental data to illustrate the dynamic range over which 2C pyrometry can determine the soot concentration and temperature in theory and in practice.

47 OTHER INSTRUMENTATION↗

Monitoring complex trace-gas mixtures by long-path laser absorption spectrometry

Laser-based spectrophotometric methods, which have been proposed for the detection of trace concentrations of gaseous contaminants, include Raman and passive radiometry. The paper discusses a simple long-path laser absorption method which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels. A number of species were selected which are most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Absorption coefficients at CO2 laser wavelengths were measured, accurate to + 3 per cent or better, for each of these species. This data base was then used to determine the presence and concentration of the contaminants in prepared mixtures of 12 to 15 gases. Computer programs have been developed which will permit a real-time analysis of the monitored atmosphere. Minimum detectable concentrations for individual species are generally in the ppm range, and are not seriously degraded by interferences even in complex mixtures. Estimates of the dynamic range of this monitoring technique for various system configurations and comparison with other methods of analysis are discussed

Green, B. D.↗

Broadband, Common-path, Interferometric Wavefront Sensor

Hybrid sensors comprising Shack-Hartmann Wavefront Sensor (S-HWFS) and Zernike Wavefront Sensor (Z-WFS) capabilities are presented. The hybrid sensor includes a Z-WFS optically arranged in-line with a S-HWFS such that the combined wavefront sensor operates across a wide dynamic range and noise conditions. The Z-WFS may include the ability to introduce a dynamic phase shift in both transmissive and reflective modes.

Wallace, James Kent↗

Broadband, Common-Path, Interferometric Wavefront Sensor

Hybrid sensors comprising Shack-Hartmann Wavefront Sensor (S-HWFS) and Zernike Wavefront Sensor (Z-WFS) capabilities are presented. The hybrid sensor includes a Z-WFS optically arranged in-line with a S-HWFS such that the combined wavefront sensor operates across a wide dynamic range and noise conditions. The Z-WFS may include the ability to introduce a dynamic phase shift in both transmissive and reflective modes.

Wallace, James Kent↗

A nuclear physics program at the Rare Isotope Beams Accelerator Facility in Korea

This paper outlines the new physics possibilities that fall within the field of nuclear structure and astrophysics based on experiments with radioactive ion beams at the future Rare Isotope Beams Accelerator facility in Korea. This ambitious multi-beam facility has both an Isotope Separation On Line (ISOL) and fragmentation capability to produce rare isotopes beams (RIBs) and will be capable of producing and accelerating beams of wide range mass of nuclides with energies of a few to hundreds MeV per nucleon. The large dynamic range of reaccelerated RIBs will allow the optimization in each nuclear reaction case with respect to cross section and channel opening. The low energy RIBs around Coulomb barrier offer nuclear reactions such as elastic resonance scatterings, one or two particle transfers, Coulomb multiple-excitations, fusion-evaporations, and direct capture reactions for the study of the very neutron-rich and proton-rich nuclides. In contrast, the high energy RIBs produced by in-flight fragmentation with reaccelerated ions from the ISOL enable to explore the study of neutron drip lines in intermediate mass regions. The proposed studies aim at investigating the exotic nuclei near and beyond the nucleon drip lines, and to explore how nuclear many-body systems change in such extreme regions by addressing the following topics: the evolution of shell structure in areas of extreme proton to neutron imbalance; the study of the weak interaction in exotic decay schemes such as beta-delayed two-neutron or two-proton emission; the change of isospin symmetry in isobaric mirror nuclei at the drip lines; two protons or two neutrons radioactivity beyond the drip lines; the role of the continuum states including resonant states above the particle-decay threshold in exotic nuclei; and the effects of nuclear reaction rates triggered by the unbound proton-rich nuclei on nuclear astrophysical processes.

43 PARTICLE ACCELERATORS↗

X-ray reflectivity measurement of interdiffusion in metallic multilayers during rapid heating

A technique for measuring interdiffusion in multilayer materials during rapid heating using X-ray reflectivity is described. In this technique the sample is bent to achieve a range of incident angles simultaneously, and the scattered intensity is recorded on a fast high-dynamic-range mixed-mode pixel array detector. Heating of the multilayer is achieved by electrical resistive heating of the silicon substrate, monitored by an infrared pyrometer. As an example, reflectivity data from Al/Ni heated at rates up to 200 K s -1 are presented. At short times the interdiffusion coefficient can be determined from the rate of decay of the reflectivity peaks, and it is shown that the activation energy for interdiffusion is consistent with a grain boundary diffusion mechanism. At longer times the simple analysis no longer applies because the evolution of the reflectivity pattern is complicated by other processes, such as nucleation and growth of intermetallic phases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward nonthermal control of excited quantum materials: framework and investigations by ultrafast electron scattering and imaging

Quantum material systems upon applying ultrashort laser pulses provide a rich platform to access excited material phases and their transformations that are not entirely like their equilibrium counterparts. The addressability and potential controls of metastable or long-trapped out-of-equilibrium phases have motivated interests both for the purposes of understanding the nonequilibrium physics and advancing the quantum technologies. Thus far, the dynamical spectroscopic probes eminently focus on microscopic electronic and phonon responses. For characterizing the long-range dynamics, such as order parameter fields and fluctuation effects, the ultrafast scattering probes offer direct sensitivity. Bridging the connections between the microscopic dynamics and macroscopic responses is central toward establishing the nonequilibrium physics behind the light-induced phases. Here, we present a path toward such understanding by cross-examining the structure factors associated with different dynamical states obtained from ultrafast electron scattering, imaging, and modeling. We give the basic theoretical framework on describing the non-equilibrium scattering problems and briefly describe how such framework relates to the out-of-equilibrium phenomena. We give effective models outlining the emergences of nonthermal critical points, hidden phases, and non-equilibrium relaxational responses from vacuum-suspended rare-earth tritellurides, tantalum disulfides thin films, and vanadium dioxide nanocrystalline materials upon light excitations.

79 ASTRONOMY AND ASTROPHYSICS↗

A new high-speed solar radio spectrograph for meter and decameter wavelengths

The design and characteristics of a high resolution, digital solar spectrograph are discussed. The spectrometer operates in the 10 to 80 MHz range. The primary considerations in the design of the spectrograph were: (1) optimun sensitivity, (2) wide dynamic range, (3) flexibility in time and frequency resolution, and (4) modern data handling techniques with a simple computer interface.

Mosier, S. R.↗

Almond-Shaped Test Body

Almond shaped test body developed for use in electromagnetic anechoic chamber for evaluation of range and measurement of components has low radar cross section that varies with angle over large dynamic range. Surface is composite formed by joining properly scaled ellipsoidal surfaces. Used to mount components whose radar cross sections are to be measured, and simulate backscatter characteristics of component as though it were over infinite ground plane.

Dominek, Allen↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high.

Freeman, A.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6 dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high...

Freeman, A.↗

Fiber Optic Instrumentation in High Temperature Irradiation Environments

The extremely harsh conditions of advanced reactor designs pose serious challenges for nuclear fuels and materials. Traditional instrumentation (thermocouples, strain gauges, etc.) are not well suited for extended operation in such a harsh environment. This work discusses the potential for using fiber optic-based instrumentation in high temperature irradiation experiments. The primary limitation of fiber optic instrumentation in irradiation experiments is signal darkening due to attenuation in the fiber material. A computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Preliminary results obtained using this model are shown for one cycle of irradiation in the high flux isotope reactor at various temperatures. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose in order to validate the predictive model. Demonstration of the safety and reliability of new and enhanced nuclear fuels and materials is essential for improving the safety and reliability of existing nuclear power plants and for the licensing and operation of advanced nuclear reactor technologies. Experimental validation of fuel performance codes requires high fidelity measurements during instrumented irradiation experiments. Therefore, a clear need exists for sensors of unprecedented accuracy, resolution, time/space/energy spectrum dependence, reduced size, and, perhaps most importantly, performance in harsh environments. The harsh environment during accelerated irradiation testing could include temperatures from 300 deg. C up to 2600 deg. C, and radiation damage levels ranging from 1 to greater than 100 dpa. Optical fiber-based sensors are a promising candidate for instrumentation in high temperature irradiation environments. Optical fibers are small, inexpensive, chemically inert, immune to electromagnetic interference, and made of high temperature radiation-hard materials. The ability to make distributed measurements of temperature or strain using a single inexpensive optical fiber currently exists for non-extreme environments as commercially available technology. Other advanced sensing technologies such as laser ultrasound, borescopes, and laser-induced breakdown spectroscopy use fiber optic light delivery as a critical component of the sensor design. Some potential applications for optical fiber-based sensors in instrumented irradiation experiments include in-situ measurements of thermal conductivity, ultrasonic measurement of elastic constants (with fiber optic delivery of signal for generation and detection of ultrasonic wave), and distributed measurements of temperature and/or strain (i.e., swelling). The primary limitation for the use of optical technologies for harsh environment (e.g., high neutron flux reactor environments) instrumentation is the attenuation of the light signal due to the effects of temperature and/or irradiation. This work summarizes initial efforts towards developing a predictive model of temperature-dependent radiation-induced attenuation in fused silica optical fibers at high dose. If there is adequate transmission in the fibers, fiber optic-based instrumentation could provide highly accurate distributed measurements during instrumented fuel/material irradiation experiments. Preliminary results show attenuation on the order of 5- 10 dB/m in the wavelength range of 750-900 nm at temperatures of 300 deg. C and below after one HFIR cycle (24 days). At higher temperatures (600 and 900 deg. C), the attenuation is reduced below 5 dB/m in the same wavelength range. This amount of attenuation is acceptable for most fiber optic based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high flux region. Many optical components use a wavelength of 850 nm, which lies in the low attenuation window. In order to refine and ultimately validate the predictive model of optical fiber attenuation, a reactor irradiation campaign has been initiated. Rabbit irradiation capsules have been designed to irradiate optical fiber material (low and high OH fused silica, as well as single crystal sapphire) specimens in the HFIR at temperatures ranging from 100 to 1200 deg. C. (authors)

42 ENGINEERING↗

Ultratrace Uranium Fingerprinting with Isotope Selective Laser Ionization Spectrometry

Uranium isotope ratios can provide source information for tracking uranium contamination in a variety of fields, ranging from occupational bioassay to monitoring aftereffects of nuclear accidents. We describe the development of Isotope Selective Laser Ionization Spectrometry (ISLIS) for ultratrace measurement of the minor isotopes 234U, 235U, and 236U with respect to 238U. Optical isotopic selectivity in three-step excitation with single-mode continuous wave lasers is capable of measuring the minor isotopes at relative abundances below 1 ppm, and is not limited by isobaric interferences such as 235UH+ during measurement of 236U. This relative abundance limit approaches the threshold for measurement of uranium minor isotopes with conventional mass spectrometry, typically 10-7, but without mass spectrometric analysis of the laser-created ions. Uranyl nitrate standards from an international blind comparison were used to test analytical performance for different isotopic compositions and with quantities ranging from 11 ng to 10 µg total uranium. Isotopic ratio determination was demonstrated over a linear dynamic range of 7 orders of magnitude with a few percent relative precision and detection limits below 500 fg for the minor isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗