Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Industrial Conveyor Motor Performance Evaluation

The purpose of this project is to estimate the energy savings potential from a switched-reluctance motor (SRM) compared to an induction motor equipped with variable frequency drive (VFD) in a straight belt conveyor application. To experimentally evaluate savings in a realistic scenario, a baseline motor and VFD were selected from one of ComEd’s manufacturing customers’ conveyor systems. It was desired to not only estimate savings in the selected conveyor system, but to evaluate potential savings from using the SRM in any straight belt conveyor. Therefore, NREL developed a conveyor system energy calculation tool to supplement the experimental results of this assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supply Chain for Energy Technologies

Understanding manufacturing cost implications of technologies is critical to aid adoption of next-generation energy solutions. It is important to understand not only of the manufacturing costs and value-add along the supply chain, but also gain understanding of manufacturing location decisions. By identifying a technology's competitive strengths and weaknesses, analyses give researchers and program decision makers the data and insights needed to create strategies and plans that better promote U.S. economic growth and pursue R&D activities that have the greatest long-term potential to yield significant energy savings for U.S. consumers. In this talk, we present examples of analysis from a variety of energy technologies to demonstrate how manufacturing cost analysis can be used to answer specific policy or research questions. In addition, we present case studies showing the importance of understanding trade flow, manufacturing locations, and capacity and utilization to inform economic growth and potential for technology adoption.

benchmarking↗

Predicting industrial building energy consumption with statistical and machine-learning models informed by physical system parameters

The industrial sector consumes about one-third of global energy, making them a frequent target for energy use reduction. Variation in energy usage is observed with weather conditions, as space conditioning needs to change seasonally, and with production, energy-using equipment is directly tied to production rate. Previous models were based on engineering analyses of equipment and relied on site-specific details. Others consisted of single-variable regressors that did not capture all contributions to energy consumption. Further, new modeling techniques could be applied to rectify these weaknesses. Applying data from 45 different manufacturing plants obtained from industrial energy audits, a supervised machine-learning model is developed to create a general predictor for industrial building energy consumption. The model uses features of air enthalpy, solar radiation, and wind speed to predict weather-dependency; motor, steam, and compressed air system parameters to capture support equipment contributions; and operating schedule, production rate, number of employees, and floor area to determine production-dependency. Results showed that a model that used a linear regressor over a transformed feature space could outperform a support vector machine and utilize features more representative of physical systems. Using informed parameters to build a reliable predictor will more accurately characterize a manufacturing facility's energy savings opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The CanBikeCO Full Pilot: Long-Term Results and Analysis From an E-Bike Program in Colorado, USA

Personal micromobility devices like bicycles, e-bikes, and scooters are low- or zero-energy alternatives to single-occupancy vehicles. However, a lack of data has led to a dearth of data-driven research on personally owned e-bike usage. We present longitudinal findings from the CanBikeCO program, focused on e-bike adoption and use across demographics, trip characteristics, and geographies in the state of Colorado. CanBikeCO recorded travel survey data from low-income individuals provided with personal e-bikes by the Colorado Energy Office in six communities across Colorado from July 2021 to December 2022. The data were collected using a custom instance of the National Renewable Energy Laboratory OpenPATH platform, which combines passive data collection with semantic information such as trip mode and purpose labels. To our knowledge, there are no prior travel survey data on personally owned e-bikes with this range and scope. Insights from this unique dataset include: (i) work trips were 17% more likely than average trips to be taken on an e-bike, (ii) e-bikes were most often reported to replace cars (34% of e-bike trips) and other personal micromobility devices (22%), and (iii) participants favored walking for trips less than 1 mile, e-bikes for trips of 1-3 miles, and e-bikes, cars, or shared rides for trips of 3-20 miles. The data used to generate these results have been made available in the Transportation Secure Data Center. We find e-bike use is appealing across age groups and may be related to characteristics of land use, urban form, occupation, income, and car ownership. We conclude for this population that the energy demand added by e-bike use (induced demand and replacing non-motorized modes) is outweighed by the reduction in energy demand from replacement of single-occupancy vehicle trips with e-bike trips. Our findings suggest considerable potential for energy savings from personal e-bike ownership.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating Building Energy Code Compliance and Savings Potential through Large-Scale Simulation with Models Inferred by Field Data

Building energy code compliance is the crucial link between the actual energy savings and the efficiency prescribed in energy codes. A research project aiming to identify opportunities to reduce energy consumption in new single-family residential construction by increasing compliance with the building energy code was conducted in several states of the United States. The study was comprised of three phases: (1) a baseline study to document typical practice and identify opportunities for improvement based on empirical data gathered from the field; (2) an education and training phase targeting the opportunities identified; and (3) a post-study to assess whether a reduction in average state-wide energy use could be achieved following the education and training phase. We proposed a novel methodology based on large-scale building energy simulation inferred by limited field data to assess the performance of a large population of homes. This paper presents the methodology, findings, and results of this study. The state-wide average energy consumption decreased at Phase III from Phase I for five of the seven states involved in the analysis. The measure-level savings potential analysis shows an overall reduction. Overall, the training and education phase plays a recognizable role in improving compliance with building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fabrication-robust silicon photonic devices in standard sub-micron silicon-on-insulator processes

Perturbations to the effective refractive index from nanometer-scale fabrication variations in waveguide geometry plague high index-contrast photonic platforms; this includes the ubiquitous sub-micron silicon-on-insulator (SOI) process. Such variations are particularly troublesome for phase-sensitive devices, such as interferometers and resonators, which exhibit drastic changes in performance as a result of these fabrication-induced phase errors. In this Letter, we propose and experimentally demonstrate a design methodology for dramatically reducing device sensitivity to silicon width variations. We apply this methodology to a highly phase-sensitive device, the ring-assisted Mach–Zehnder interferometer (RAMZI), and show comparable performance and footprint to state-of-the-art devices, while substantially reducing stochastic phase errors from etch variations. This decrease in sensitivity is directly realized as energy savings by significantly reducing the required corrective thermal tuning power, providing a promising path toward ultra-energy-efficient large-scale silicon photonic circuits.

Rizzo, Anthony (ORCID:000000034752797X)↗

03.02.02.45: Energy Efficiency Improvement Approaches in Ice Related Processes

The primary objective of this project was to facilitate the dislocation of the interfacial ice layer by employing advanced materials and ultrasonic vibration to reduce ice adhesion strength. This work employed two technical approaches that were thoroughly investigated and previously reported. The effectiveness of these approaches, both individually and in combination, has been quantified, demonstrating notable energy savings. The projected payback period for these enhancements is approximately 2.2 years or less, contingent upon specific energy costs. Furthermore, these advancements hold significant promise for reducing carbon emissions across various equipment scales. This study particularly focused on the ultrasonic deicing technique for diverse structures, utilizing numerical simulations to evaluate performance and potential benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar energy system performance evaluation-seasonal report for Elcam San Diego, San Diego, California

The solar energy system, Elcam San Diego, was designed to supply domestic hot water heating for a single family residence located in Encinitas, California. System description, performance assessment, operating energy, energy savings, maintenance, and conclusions are presented. The system is a 'Sunspot' two tank cascade type, where solar energy is supplied to either a 66 gallon preheat tank (solar storage) or a 40 gallon domestic hot water tank. Water is pumped directly from one of the two tanks, through the 65 square feet collector array and back into the same tank. Freeze protection is provided by automatically circulating hot water from the hot water tank through the collectors and exposed plumbing when freezing conditions exist. Auxiliary energy is supplied by natural gas. Analysis is based on instrumented system data monitored and collected for one full season of operation.

Source record↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Assistance for Galena Alaska

The City of Galena sits along the north bank of the Yukon River with no road access. Temperatures regularly reach negative 20°F in the winter and sunlight extends for up to 21 hours a day in the summer. Galena’s 400 residents, including members of the Koyukuk Athabascan culture, primarily use fuel oil and locally forested wood for heating and electricity generation. Because these resources are costly to obtain, local households have a high energy burden, spending 7% of their annual income on energy (averaging $4,000 per year). To reduce this burden, the City of Galena joined the U.S. Department of Energy’s (DOE) Remote Alaska Community Energy Efficiency (RACEE) Competition, where they received financial and technical assistance to implement energy savings solutions across their community, including building envelope improvements, solar panels, and LED lighting. Additionally, Galena installed new energy monitoring equipment to continue measuring the impacts of this work beyond the RACEE project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit energy conservation in residential buildings in southern California

The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

Turner, R. H.↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Sumner County Field Validation: An Assessment of Thermal Energy Storage in Municipal Buildings in Mixed-Humid Climates

The overall aim of the project was to conduct a full-scale implementation of TES in an operational administrative building in Sumner County, Kansas with a special focus of phase change material (PCM) passive implementation in the ceiling envelope. PCM was used with the intention of increasing the ability of public buildings to shift the peak HVAC energy demand and consumption. The study was conducted during the span of three years in 3 phases, (i) phase I: energy audit (pre-retrofit) (ii) phase II: ceiling tile installation (PCM retrofit), and (iii) phase III: energy evaluation (post-retrofit). Temperature and HVAC energy measurements as well as weather data collected is used for an extensive validation study and further parametric assessment to find (a) annual HVAC energy savings (b) peak period electricity and load savings focusing on cooling dominant months of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Intersection Control on Battery Electric Vehicle Energy Consumption

Battery electric vehicle (BEV) sales have significantly increased in recent years. They have different energy consumption patterns compared to the fuel consumption patterns of internal combustion engine vehicles (ICEVs). This study quantified the impact of intersection control approaches—roundabout, traffic signal, and two-way stop controls—on BEVs’ energy consumption. The paper systematically investigates BEVs’ energy consumption patterns compared to the fuel consumption of ICEVs. The results indicate that BEVs’ energy consumption patterns are significantly different than ICEVs’ patterns. For example, for BEVs approaching a high-speed intersection, the roundabout was found to be the most energy-efficient intersection control, while the two-way stop sign was the least efficient. In contrast, for ICEVs, the two-way stop sign was the most fuel-efficient control, while the roundabout was the least efficient. Findings also indicate that the energy saving of traffic signal coordination was less significant for BEVs compared to the fuel consumption of ICEVs since more regenerative energy is produced when partial or poorly coordinated signal plans are implemented. The study confirms that BEV regenerative energy is a major factor in energy efficiency, and that BEVs recover different amounts of energy in different urban driving environments. The study suggests that new transportation facilities and control strategies should be designed to enhance BEVs’ energy efficiency, particularly in zero emission zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation Strategy - Efficiency Standards and Labeling Programs in Uganda

In 2016, the development of an Energy Efficiency Roadmap (USAID, 2017) undertaken by Agency for International Development (USAID) showed that an energy-saving potential of 310 MW by 2030 was possible at a cost lower than the current supply of electricity. However, the energy efficiency potential is spread out across many technologies and requires the establishment of enabling policies to stimulate efficient use of energy. Chief among these is the establishment of energy- efficiency standards and labeling (EESL) for electric equipment as indicated by Uganda national energy policy legislation (MEMD, 2002). This report first includes an assessment of energy consumption in the residential sector to identify priority products of focus for the EESL program followed by an assessment of the legal and administrative capacity needs of Ugandan institutions to operate and enforce Uganda’s EESL program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗