Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY↗

On the equivalence between SRS and PCO formulations of superstring perturbation theory

We establish the equivalence between two formulations of superstring perturbation theory, one based on integration over the supermoduli space of super Riemann surfaces (SRS), the other based on integration over the bosonic moduli space with insertions of picture changing operators (PCO) on the worldsheet and the vertical integration prescription, by showing how the latter arises from a specific construction of the supermoduli integration contour.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Equivalence of emergent de Sitter spaces from conformal field theory

Recently, two groups have made distinct proposals for a de Sitter space that is emergent from conformal field theory (CFT). The first proposal is that, for two-dimensional holographic CFTs, the kinematic space of geodesics on a space-like slice of the asymptotically anti-de Sitter bulk is two-dimensional de Sitter space (dS 2 ), with a metric that can be derived from the entanglement entropy of intervals in the CFT. In the second proposal, de Sitter dynamics emerges naturally from the first law of entanglement entropy for perturbations around the vacuum state of CFTs. We provide support for the equivalence of these two emergent spacetimes in the vacuum case and beyond. In particular, we study the kinematic spaces of nontrivial solutions of 3d gravity, including the BTZ black string, BTZ black hole, and conical singularities. We argue that the resulting spaces are generically globally hyperbolic spacetimes that support dynamics given boundary conditions at future infinity. For the BTZ black string, corresponding to a thermal state of the CFT, we show that both prescriptions lead to an emergent hyperbolic patch of dS 2 . As a result, we offer a general method for relating kinematic space and the auxiliary de Sitter space that is valid in the vacuum and thermal cases.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determination of the Coefficients of Heat Transfer and Friction in Supercritical-Pressure Nuclear Reactors with Account of the Intensity and Scale of Flow Turbulence on the Basis of the Theory of Stochastic Equations and Equivalence of Measures

New dependences of the coefficients of heat transfer and friction have been presented which are used for calculations in the reactor core at a supercritical water pressure by taking account of the parameters of perturbation in the coolant flow: of the intensity and scale of flow turbulence. These solutions have been obtained based on stochastic systems of equations for the turbulence and the equivalence of measures between deterministic (laminar) and random (turbulent) flows.

42 ENGINEERING↗

Estimates of Equivalent Heat Conductivity Coefficients of Carbon Nanotubes

We have obtained estimates of equivalent heat conductivity coefficients of nanostructured elements on the basis of the constructed mathematical model of the thermal energy transfer in a single-layer and a multilayer nanotube surrounded by a homogeneous material in the composite matrix. The values of such coefficients permit conditional replacement of nanotubes by solid anisotropic fibers, which makes it possible, in predicting the effective heat conductivity coefficient of a composite modified by carbon nanotubes, to use the known methods developed in detail to fit fibrous composites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Formal Equivalence Between Partitioned and Partition-Free Quenches in Quantum Transport

In this paper, we review the partitioned and partition-free approaches to the calculation of the time-dependent response of a molecular junction to the switch-on of an arbitrary time-dependent bias. Using the nonequilibrium Green’s function formalism on different time contours, we derive a formal equivalence between these two approaches. This clarifies a recent result of Odashima and Lewenkopf (Phys Rev B 95:104301, 2017), which is valid for a static bias and single-level molecular structure, and extends it to arbitrary time-dependent biases and arbitrarily large molecular structures.

74 ATOMIC AND MOLECULAR PHYSICS↗

On Derived Equivalence of Algebras of Semidihedral Type with Two Simple Modules

The Hochschild cohomology groups of degrees not exceeding 3 are computed for algebras of semidihedral type that form the family SD(2B){sub 1} (from the famous K. Erdmann’s classification). In the calculation, the beforehand construction of the initial part of the minimal projective bimodule resolution is used for algebras from the family under discussion. The obtained results imply that the algebras from the families SD(2B){sub 1} and SD(2B){sub 2} with the same parameters in defining relations are not derived equivalent.

97 MATHEMATICS AND COMPUTING↗

Alpha spectroscopy backgrounds at Lawrence Livermore National Laboratory: technical equivalency for backgrounds with blank plates versus backgrounds with no plates

Alpha spectroscopy chamber backgrounds are routinely measured using blank plates. Operator time spent moving blank plates in and out of chambers is significant. If chamber backgrounds are measured in empty chambers, time spent moving blank plates can be reclaimed for other uses. This study compares here results of chamber backgrounds measured with and without plates. Five hundred fourteen chamber backgrounds measured with plates are paired with 514 chamber backgrounds measured without plates. The total counts within 13 spectral regions of interest are compared statistically. Chamber backgrounds measured without blank plates are found statistically equivalent to chamber backgrounds measured with blank plates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multiaxial Fatigue Life Prediction Based on Short Crack Propagation Model with Equivalent Strain Parameter

The maximum shear strain and the normal strain excursion on the critical plane are regarded as the primary parameters of the crack driving force to establish a new short crack model in this paper. An equivalent strain-based intensity factor is proposed to correlate the short crack growth rate under multiaxial loading. According to the short crack model, a new method is proposed for multiaxial fatigue life prediction based on crack growth analysis. It is demonstrated that the method can be used under proportional and non-proportional loadings. The predicted results showed a good agreement with experimental lives in both high-cycle and low-cycle regions.

36 MATERIALS SCIENCE↗

Properties of Equivalent Source Distributions Useful for Inverse Thermal Analysis

A general approach for inverse thermal analysis of heat deposition processes is parametric modeling of such processes using effective or equivalent source distributions (ESDs). ESDs can be adjusted conveniently for calculation of temperature fields, which are constrained according to boundary and temperature constraint conditions. This study applies properties of ESDs useful for parametric modeling of heat deposition processes. Inverse thermal analysis of a friction stir weld is presented, which is prototypical of processes tending to be complex with respect to energy deposition morphology. This analysis demonstrates properties of ESDs providing relatively optimal parametric modeling of energy deposition processes.

36 MATERIALS SCIENCE↗

Distributed intelligence and the equivalence of matter and information

Here, it is argued that science of discontinua represents a major paradigm shift in how scientific research is done. First, a historical perspective is given, followed by key aspects of discontinuum simulations and its potential in aiding research and development. This is followed by a philosophical perspective on equivalence of matter and information as inspired by Aristotle’s quest for souls in living things such as cells. Finally, the universality of the discontinuum approach is explored with its consequences for computing and artificial intelligence.

97 MATHEMATICS AND COMPUTING↗

Assessment of penetration of quantum dots through in vitro and in vivo human skin using the human skin equivalent model and the tape stripping method

Quantum dots (QDs) are rapidly emerging as an important class of nanoparticles (NPs) with potential applications in medicine. However, little is known about penetration of QDs through human skin. This study investigated skin penetration of QDs in both in vivo and in vitro human skin. Using the tape stripping method, this study demonstrates for the first time that QDs can actually penetrate through the stratum corneum (SC) of human skin. Transmission electron microscope (TEM) and energy diverse X-ray (EDX) analysis showed accumulation of QDs in the SC of a human skin equivalent model (HSEM) after dermal exposure to QDs. These findings suggest possible transdermal absorption of QDs after dermal exposure over a relatively long period of time.

60 APPLIED LIFE SCIENCES↗

Equivalent Biochemical Control and Improved Prostate-Specific Antigen Nadir After Permanent Prostate Seed Implant Brachytherapy Versus High-Dose Three-Dimensional Conformal Radiotherapy and High-Dose Conformal Proton Beam Radiotherapy Boost

Purpose: Permanent prostate implant brachytherapy (PPI), three-dimensional conformal radiotherapy (3D-CRT), and conformal proton beam radiotherapy (CPBRT) are used in the treatment of localized prostate cancer, although no head-to-head trials have compared these modalities. We studied the biochemical control (biochemical no evidence of disease [bNED]) and prostate-specific antigen (PSA) nadir achieved with contemporary PPI, and evaluated it against 3D-CRT and CPBRT. Patients and Methods: A total of 249 patients were treated with PPI at the University of California, San Francisco, and the outcomes were compared with those from a 3D-CRT cohort and the published results of a high-dose CPBRT boost (CPBRTB) trial. For each comparison, subsets of the PPI cohort were selected with patient and disease criteria similar to those of the reference group. Results: With a median follow-up of 5.3 years, the bNED rate at 5 and 7 years achieved with PPI was 92% and 86%, respectively, using the American Society for Therapeutic Radiology and Oncology (ASTRO) definition, and 93% using the PSA nadir plus 2 ng/mL definition. Using the ASTRO definition, a 5-year bNED rate of 78% was achieved for the 3D-CRT patients compared with 94% for a comparable PPI subset and 93% vs. 92%, respectively, using the PSA nadir plus 2 ng/mL definition. The median PSA nadir for patients treated with PPI and 3D-CRT was 0.10 and 0.40 ng/mL, respectively (p < .0001). For the CPBRT comparison, the 5-year bNED rate after a CPBRTB was 91% using the ASTRO definition vs. 93% for a similar group of PPI patients. A greater proportion of PPI patients achieved a lower PSA nadir compared with those achieved in the CPBRTB trial (PSA nadir <=0.5 ng/mL, 91% vs. 59%, respectively). Conclusion: We have demonstrated excellent outcomes in low- to intermediate-risk patients treated with PPI, suggesting at least equivalent 5-year bNED rates and a greater proportion of men achieving lower PSA nadirs compared with 3D-CRT or CPBRTB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Method for the Prediction of Late Organ-at-Risk Toxicity After Radiotherapy of the Prostate Using Equivalent Uniform Dose

Purpose: To evaluate the predictive value of equivalent uniform doses (EUD) for late bladder and rectal toxicity after high-dose three-dimensional conformal radiation therapy (3D-CRT) to the prostate. Materials and Methods: Using the method developed by Kutcher et al., EUDs for whole bladder and rectum were calculated from the dose-volume histograms of 180 patients with localized prostate cancer treated to 70-74 Gy with 3D-CRT. Late complications were recorded using the Radiation Therapy Oncology Group scale, correlated against EUD and known physical predictive indicators. Results: EUD is an independent prognostic factor for Grade 2+ long-term rectal and bladder toxicity after radiation treatment to the prostate. Patients receiving an EUD >63.1 Gy to the rectum have a statistically significant (10% vs. 30%; p = 0.002) higher risk of developing Grade 2+ late complications. Patients receiving an EUD >53.4 Gy to the bladder have a statistically significant (10% vs. 33%; p = 0.001) higher risk of developing Grade 2+ late complications. Conclusions: It has been demonstrated that EUD is a strong independent predictive factor for Grade 2+ late complications after 3D-CRT to the prostate. Threshold values have been demonstrated for both bladder and rectum, above which there is a clinically significant increased risk of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy vs. Intensity-Modulated Proton Therapy for Whole Pelvis Irradiation in High-Risk Prostate Cancer Patients: Dosimetric, Normal Tissue Complication Probability, and Generalized Equivalent Uniform Dose Analysis

Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normal tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Generalized Equivalent Uniform Dose Atlases to Combine and Analyze Prospective Dosimetric and Radiation Pneumonitis Data From 2 Non-Small Cell Lung Cancer Dose Escalation Protocols

Purpose: To demonstrate the use of generalized equivalent uniform dose (gEUD) atlas for data pooling in radiation pneumonitis (RP) modeling, to determine the dependence of RP on gEUD, to study the consistency between data sets, and to verify the increased statistical power of the combination. Methods and Materials: Patients enrolled in prospective phase I/II dose escalation studies of radiation therapy of non-small cell lung cancer at Memorial Sloan-Kettering Cancer Center (MSKCC) (78 pts) and the Netherlands Cancer Institute (NKI) (86 pts) were included; 10 (13%) and 14 (17%) experienced RP requiring steroids (RPS) within 6 months after treatment. gEUD was calculated from dose-volume histograms. Atlases for each data set were created using 1-Gy steps from exact gEUDs and RPS data. The Lyman-Kutcher-Burman model was fit to the atlas and exact gEUD data. Heterogeneity and inconsistency statistics for the fitted parameters were computed. gEUD maps of the probability of RPS rate {>=}20% were plotted. Results: The 2 data sets were homogeneous and consistent. The best fit values of the volume effect parameter a were small, with upper 95% confidence limit around 1.0 in the joint data. The likelihood profiles around the best fit a values were flat in all cases, making determination of the best fit a weak. All confidence intervals (CIs) were narrower in the joint than in the individual data sets. The minimum P value for correlations of gEUD with RPS in the joint data was .002, compared with P=.01 and .05 for MSKCC and NKI data sets, respectively. gEUD maps showed that at small a, RPS risk increases with gEUD. Conclusions: The atlas can be used to combine gEUD and RPS information from different institutions and model gEUD dependence of RPS. RPS has a large volume effect with the mean dose model barely included in the 95% CI. Data pooling increased statistical power.

62 RADIOLOGY AND NUCLEAR MEDICINE↗