Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Effect of exercise training on cardiopulmonary baroreflex control of forearm vascular resistance in humans

We studied the stimulus-response characteristics of cardiopulmonary baroreflex control of forearm vascular resistance (FVR) in four groups of male volunteer subjects: i) unfit, ii) physically fit, iii) before and after 10 wk of endurance training (chronic blood volume expansion), and iv) before and after acute blood volume expansion. We assessed the relationship between reflex stimulus, i.e., changes in central venous pressure and response, i.e., FVR, during unloading of cardiopulmonary mechanoreceptors with lower body negative pressure (LBNP, 0 to -20 mm Hg). The slope of the linear relationship between FVR and CVP, the index of the responsiveness of this baroreflex, was significantly diminished (> 50%) in the fit subjects compared with the unfit. The slope of the FVR-CVP relationship was inversely correlated with the subject's total blood volume, suggesting that blood volume expansion was related to the attenuated CP baroreflex. In the exercise training study, maximal oxygen consumption and blood volume increased following 10 wk of endurance training (N = 14) but were unchanged in the time control group (N = 7). The slope of the FVR-CVP relationship was significantly reduced (32%) following 10 wk of training but was unchanged in the time control group. The reduction in slope of the FVR-CVP relationship was inversely related to the increase in blood volume associated with exercise training. Acute blood volume expansion 8 ml.kg-1 body weight with 5% human serum albumin solution) significantly reduced the slope of the FVR-CVP relationship. These data support the hypothesis that the attenuated forearm vascular reflex in physically fit individuals is related to a training-induced hypervolemia.(ABSTRACT TRUNCATED AT 250 WORDS).

Review↗

Influence of exercise training on the oxidative capacity of rat abdominal muscles

Our purpose was to determine if endurance exercise training would increase the oxidative capacity of the abdominal expiratory muscles of the rat. Accordingly, 9 male rats were subjected to an endurance training protocol (1 h/day, 6 days/week, 9 weeks) and 9 litter-mates served as controls. Citrate synthase (CS) activity was used as an index of oxidative capacity, and was determined in the following muscles: soleus, plantaris, costal diaphragm, crural diaphragm, and in all four abdominal muscles: rectus abdominis, transversus abdominis, external oblique, and internal oblique. Compared to their non-trained litter-mates, the trained rats had higher peak whole body oxygen consumption rates (+ 16%) and CS activities in plantaris (+34%) and soleus (+36%) muscles. Thus, the training program caused substantial systemic and locomotor muscle adaptations. The CS activity of costal diaphragm was 20% greater in the trained animals, but no difference was observed in crural diaphragm. The CS activity in the abdominal muscles was less than one-half of that in locomotor and diaphragm muscles, and there were no significant changes with training except in the rectus abdominis where a 26% increase was observed. The increase in rectus abdominis CS activity may reflect its role in postural support and/or locomotion, as none of the primary expiratory pumping muscles adapted to the training protocol. The relatively low levels of CS activity in the abdominal muscles suggests that they are not recruited frequently at rest, and the lack of an increase with training indicates that these muscles do not contribute significantly to the increased ventilatory activity accompanying exercise in the rat.

Non-NASA Center↗

Exercise training, glucose transporters, and glucose transport in rat skeletal muscles

It was previously found that voluntary wheel running induces an increase in the insulin-sensitive glucose transporter, i.e., the GLUT4 isoform, in rat plantaris muscle (K. J. Rodnick, J. O. Holloszy, C. E. Mondon, and D. E. James. Diabetes 39: 1425-1429, 1990). The present study was undertaken to determine whether 1) the increase in muscle GLUT4 protein is associated with an increase in maximally stimulated glucose transport activity, 2) a conversion of type IIb to type IIa or type I muscle fibers plays a role in the increase in GLUT4 protein, and 3) an increase in the GLUT1 isoform is a component of the adaptation of muscle to endurance exercise. Five weeks of voluntary wheel running that resulted in a 33% increase in citrate synthase activity induced a 50% increase in GLUT4 protein in epitrochlearis muscles of female Sprague-Dawley rats. The rate of 2-deoxy-glucose transport maximally stimulated with insulin or insulin plus contractions was increased approximately 40% (P less than 0.05). There was no change in muscle fiber type composition, evaluated by myosin ATPase staining, in the epitrochlearis. There was also no change in GLUT1 protein concentration. We conclude that an increase in GLUT4, but not of GLUT1 protein, is a component of the adaptive response of muscle to endurance exercise and that the increase in GLUT4 protein is associated with an increased capacity for glucose transport.

NASA Discipline Cell Biology↗

Exercise and pharmacological countermeasures for bone loss during long-duration space flight

Bone loss in the lower extremities and lumbar spine is an established consequence of long-duration human space flight. Astronauts typically lose as much bone mass in the proximal femur in 1 month as postmenopausal women on Earth lose in 1 year. Pharmacological interventions have not been routinely used in space, and countermeasure programs have depended solely upon exercise. However, it is clear that the osteogenic stimulus from exercise has been inadequate to maintain bone mass, due to insufficient load or duration. Attention has therefore been focused on several pharmacological interventions that have been successful in preventing or attenuating osteoporosis on Earth. Anti-resorptives are the class of drugs most commonly used to treat osteoporosis in postmenopausal women, notably alendronate sodium, risedronate sodium, zoledronic acid, and selective estrogen receptor modulators, such as raloxifene. There has also been considerable recent interest in anabolic agents such as parathyroid hormone (PTH) and teriparatide (rhPTH [1-34]). Vitamin D and calcium supplementation have also been used. Recent studies of kindreds with abnormally high bone mineral density have provided insight into the genetic regulation of bone mass. This has led to potential therapeutic interventions based on the LRP5, Wnt and BMP2 pathways. Another target is the RANK-L/osteoprotegerin signaling pathway, which influences bone turnover by regulating osteoclast formation and maturation. Trials using such therapies in space are being planned. Among the factors to be considered are dose-response relationships, bone quality, post-use recovery, and combination therapies--all of which may have unique characteristics when the drugs are used in space.

NASA Discipline Musculoskeletal↗

EXERCISE WITHIN LOWER BODY NEGATIVE PRESSURE AS AN ARTIFICIAL GRAVITY COUNTERMEASURE

Current exercise systems for space, which attempt to maintain performance, are unable to generate cardiovascular and musculoskeletal loads similar to those on Earth [1, 2]. The purpose of our research is to evaluate the use of lower body negative pressure (LBNP) treadmill exercise to prevent deconditioning during simulated microgravity.

Hargens, Alan R.↗

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.↗

WISE-2005 Protective Effect of Exercise within LBNP Countermeasure Detected by Heart Rate Response to Low Levels of LBNP

Sixteen women were studied before, during and after a 60 day, continu ous 6" head-down bed-rest (HDBR). Subjects were randomly assigned to two groups: Control (no countermeasures) and Exercise+LBNP (supine ru nning within an LBNP chamber for 40-min followed by 10-min passive L BNP for 3-4 days/week, plus flywheel resistive training of the legs e very third day). Cardiovascular responses were observed before bed re st, on day 50 of HDBR and R+8 after bed rest. Subjects were supine in the LBNP device with suction applied at 0, -10, -20 and -30 mmHg LBN P for 2-min per stage. In the pre-bed rest testing, there was no diff erence in HR between the groups at rest or at -30 mmHg. On HDBR day 50, HR was elevated at supine rest for the Con not the Ex group, whil e at -30 mmHg HR was elevated above pre-HDBR for both groups, but the magnitude of increase from Pre- to HDBR day 50 was less for the Ex g roup than for the Con group. The change in HR on HDBR day 50 is an im portant indicator as it was less than 24-hours after the Exercise+LBN P countermeasure on day 49. After bed rest, no specific countermeasu res were provided in the first week, so HR responses on day R+8 refle cted the effects of bed rest with or without countermeasure plus any recovery from simply returning to the upright posture. Relative to th e Pre-bed rest responses, HR on day R+8 had recovered in the Ex group but was still elevated in the Con group. These results indicate that the cardiovascular response to LBNP is preserved to a greater degre e during bed rest by the countermeasures, and further that the cardio vascular response returned to pre-bed rest much more rapidly in the E xercise+LBNP group than hi the group that received no cardiovascular countermeasures.

Hughson, R. L.↗

Nutrition and Exercise in Space and on Earth

This presentation in outline format for delivery to school age groups (i.e., K-12) reviews the importance of proper nutrition and exercise for everyone, with emphasis on space travel. It reviews the types of space food, the constraints of eating in space, and some of the challenges of exercising in space. It lists the materials displayed and used as teaching resources, as well as materials to be distributed.

Davis-Street, Janis↗

Hardware Evaluation of the Horizontal Exercise Fixture with Weight Stack

HEF with weight stack seems to be a very sturdy and reliable exercise device that should function well in a bed rest training setting. A few improvements should be made to both the hardware and software to improve usage efficiency, but largely, this evaluation has demonstrated HEF's robustness. The hardware offers loading to muscles, bones, and joints, potentially sufficient to mitigate the loss of muscle mass and bone mineral density during long-duration bed rest campaigns. With some minor modifications, the HEF with weight stack equipment provides the best currently available means of performing squat, heel raise, prone row, bench press, and hip flexion/extension exercise in a supine orientation.

Newby, Nate↗

Alendronate and Resistive Exercise Countermeasures Against Bed Rest-Induced Bone Loss: Biochemical Markers of Bone and Calcium Metabolism

Weightlessness-induced bone loss must be counteracted to ensure crew health during extendedduration space missions. Studies were conducted to assess two bone loss countermeasures in a ground-based model: horizontal bed rest. Following a 3-wk ambulatory adaptation period, male and female subjects (aged 21-56 y) completed a 17-wk bed rest protocol. Subjects were assigned to one of three treatments: alendronate (ALEN; 10 mg/d, n=6), resistive exercise (RE; 1.5 h/d, 6 d/wk, n=8), or control (CN; no countermeasure, n=8). Dietary intake was adjusted to maintain body weight. Endocrine and biochemical indices were measured in blood and urine using standard laboratory methods. All data reported are expressed as percent change from individual pre-bedrest data. Serum calcium changed little during bed rest, and tended to decrease (4-8%) in ALEN subjects. In RE subjects, bone alkaline phosphatase and osteocalcin were increased >65 and >30%, respectively, during bed rest, while these were unchanged or decreased in ALEN and CN subjects. Urinary calcium was increased 50% in CN subjects, but was unchanged or decreased in both ALEN and RE groups. Urinary n-telopeptide excretion was increased 40-50% in CN and RE subjects, but decreased 20% in ALEN subjects. Pyridinium crosslink and deoxypyridinoline excretion were increased 20-50% during bed rest. These data suggest that RE countermeasures are effective at increasing markers of bone formation in an analog of weightlessness, while ALEN reduces markers of bone resorption. Counteracting the bone loss of space flight may require both pharmacologic and exercise countermeasures.

Smith, Scott M.↗

Prediction of Muscle Performance During Dynamic Repetitive Exercise

A method for predicting human muscle performance was developed. Eight test subjects performed a repetitive dynamic exercise to failure using a Lordex spinal machine. Electromyography (EMG) data was collected from the erector spinae. Evaluation of the EMG data using a 5th order Autoregressive (AR) model and statistical regression analysis revealed that an AR parameter, the mean average magnitude of AR poles, can predict performance to failure as early as the second repetition of the exercise. Potential applications to the space program include evaluating on-orbit countermeasure effectiveness, maximizing post-flight recovery, and future real-time monitoring capability during Extravehicular Activity.

Byerly, D. L.↗

Development of the Vibration Isolation System for the Advanced Resistive Exercise Device

This paper describes the development of the Vibration Isolation System for the Advanced Resistive Exercise Device from conceptual design to lessons learned. Maintaining a micro-g environment on the International Space Station requires that experiment racks and major vibration sources be isolated. The challenge in characterizing exercise loads and testing the system in the presence of gravity led to a decision to qualify the system by analysis. Available data suggests that the system is successful in attenuating loads, yet there has been a major component failure and several procedural issues during its 3 years of operational use.

Niebuhr, Jason H.↗

Adaptive Motor Resistance Video Game Exercise Apparatus and Method of Use Thereof

The invention comprises a method and/or an apparatus using computer configured exercise equipment and an electric motor provided physical resistance in conjunction with a game system, such as a video game system, where the exercise system provides real physical resistance to a user interface. Results of user interaction with the user interface are integrated into a video game, such as running on a game console. The resistance system comprises: a subject interface, software control, a controller, an electric servo assist/resist motor, an actuator, and/or a subject sensor. The system provides actual physical interaction with a resistance device as input to the game console and game run thereon.

Reich, Alton↗

Novel Musculoskeletal Loading System for Small Exercise Devices

Long duration spaceflight places astronauts at increased risk for muscle strain and bone fracture upon return to a 1-g or partial gravity environment. Functionally limiting decrements in musculoskeletal health are likely during Mars proving-ground and Earth-independent missions given extended transit times and the vehicle limitations for exercise devices (low-mass, small volume, little to no power). This is particularly alarming for exploration missions because astronauts will be required to perform novel and physically demanding tasks (i.e. vehicle egress, exploration, and habitat building activities) on unfamiliar terrain. Accordingly, NASA's exploration roadmap identifies the need for development of small exercise equipment that can prevent musculoskeletal atrophy and has the ability to assess musculoskeletal health at multiple time points during long-duration missions.

Downs, Meghan↗

Evaluation of Self-Scheduling Exercises Completed by Analog Crewmembers in NASA's Human Exploration Research Analog (HERA)

NASA human spaceflight missions are inherently dynamic and require frequent scheduling changes in order to adapt to changing mission priorities and objectives. Tactical level changes to the mission plan are traditionally made by a team of expert planners and operations specialists on the ground. However, astronauts are expected to execute missions more autonomously during future long duration missions. Astronauts will need to take on some of the responsibility of managing their own schedule while still abiding by the numerous constraints required by human spaceflight operations. This paper summarizes salient elements of crew performance in NASA’s Human Exploration Research Analog Campaign 3. Analog crewmembers completed a series of self-scheduling exercises to evaluate Playbook’s usability towards enabling self-scheduling without support from ground control. Playbook is a self-scheduling software tool designed and developed by our team. We also investigated how to best communicate self-scheduling tasks and constraints to the crew in order to facilitate efficient self-scheduling during isolation in a realistic environment. Our analysis identified that 30 minutes was sufficient to complete complex self-scheduling tasks. Our evaluation also identified differences between individual and collaborative performance; analog crewmembers completed self-scheduling exercises more quickly as a team as opposed to individually and reported lower subjective difficulty ratings overall.

HERA↗

Atmospheric Correction Inter-comparison eXercise, ACIX-II Land: An Assessment of Amospheric Correction Processors for Landsat 8 and Sentinel-2 Over Land

The correction of the atmospheric effects on optical satellite images is essential for quantitative and multi-temporal remote sensing applications. In order to study the performance of the state-of-the-art methods in an integrated way, a voluntary and open-access benchmark Atmospheric Correction Inter-comparison eXercise (ACIX) was initiated in 2016 in the frame of Committee on Earth Observation Satellites (CEOS) Working Group on Calibration & Validation (WGCV). The first exercise was extended in a second edition wherein twelve atmospheric correction (AC) processors, a substantially larger testing dataset and additional validation metrics were involved. The sites for the inter-comparison analysis were defined by investigating the full catalogue of the Aerosol Robotic Network (AERONET) sites for coincident measurements with satellites' overpass. Although there were more than one hundred sites for Copernicus Sentinel-2 and Landsat 8 acquisitions, the analysis presented in this paper concerns only the common matchups amongst all processors, reducing the number to 79 and 62 sites respectively. Aerosol Optical Depth (AOD) and Water Vapour (WV) retrievals were consequently validated based on the available AERONET observations. The processors mostly succeeded in retrieving AOD for relatively light to medium aerosol loading (AOD < 0.2) with uncertainties <0.08, while the overall uncertainty values were typically 0.23 ± 0.15. Better performances were observed for WV retrievals with >90% of the results falling within the suggested empirical specifications and with the Root Mean Square Error (RMSE) being mostly <0.25 g/cm2. Regarding Surface Reflectance (SR) validation two main approaches were followed. For the first one, a simulated SR reference dataset was computed over all of the test sites by using the 6SV (Second Simulation of the Satellite Signal in the Solar Spectrum vector code) full radiative transfer modelling (RTM) and AERONET measurements for the required aerosol variables and water vapour content. The performance assessment demonstrated that the retrievals were not biased for most of the bands. The uncertainties ranged from approximately 0.003 to 0.01 (excluding B01) for the best performing processors in both sensors' analyses. For the second one, measurements from the radiometric calibration network RadCalNet over La Crau (France) and Gobabeb (Namibia) were involved in the validation. The performance of the processors was in general consistent across all bands for both sensors and with low standard deviations (<0.04) between on-site and estimated surface reflectance. Overall, our study provides a good insight of AC algorithms' performance to developers and users, pointing out similarities and differences for AOD, WV and SR retrievals. Such validation though still lacks of ground-based measurements of known uncertainty to better assess and characterize the uncertainties in SR retrievals.

Atmospheric correction↗

A Novel Bone Marrow Single Cell Atlas of Mechanotransduction in Microgravity, Normal Gravity, Exercise, and Hindlimb Unloading for WT and CDKN1A-Null Regenerative Mice

Mechanical loading of adult stem cell progenitors is a key factor in modulating their proliferation, differentiation, and tissue regenerative potential, with loading generally promoting tissue formation and unloading mediating tissue loss. To address the role of mechanotransduction in maintaining stem cell-based tissue regenerative health, we generated a single cell transcriptomic atlas mapping responses of femur bone marrow mesenchymal and hematopoietic lineages to a range of altered mechanical loading conditions, both in WT B1629SF2/J mice as well as the p21/CDKN1A-null regenerative mice. We selected the femur marrow compartment as a model because of the diversity and high numbers of stem cell progenitor stages present, and because it undergoes static and cyclic hydrostatic pressure loading associated with weight-bearing and ambulation. Our study included normally loaded mice at 1g, unloading in microgravity during spaceflight as well as tail suspension hindlimb unloading, and voluntary running wheel exercise. Basal, one-year natural aging, and habitat controls were also conducted. Overall, the atlas encompasses 18 different experimental conditions with N=3 mice per condition and includes more than 500,000 single cell expressomes. Key specific findings include: increased mature reticulocyte populations in aging and unloading mice compared to active mice; greater hematopoietic and mesenchymal differentiating progenitors cluster identification in CDKN1A-null samples, especially the exercise model; distinct pseudotime cell trajectory shifts in the hematopoietic lineage for spaceflight and unloaded mice; and shifts in monocytic cell populations toward osteoclastic bone degenerative lineages in unloading and spaceflight samples. Overall mechanical loading shows increased marrow progenitor population differentiation while unloading is associated with increased CDKN1A expression and maintenance of marrow population stemness. Deletion of CDKN1A appears to remove a negative check on progenitor lineages commitment to differentiation. Finally, the Bone Marrow Mechanotransduction Single Cell Atlas will serve as a reference tool for studying marrow regenerative responses across a range of mechanical environments as they relate to CDKN1A status.

single-cell↗

Transfer of NASA Technology to the DoD: Mitigating Motion Sickness with Autogenic Feedback Training Exercise

Motion sickness poses a significant safety risk, particularly in the context of aviation. Given its prevalence among aviators and its detrimental impact on performance, researchers have attempted to identify effective mitigation strategies for motion sickness. Currently, many of the existing interventions are pharmacological, and while effective, they present a problem due to their associated adverse side effects. The primary goals of the current research were 1) demonstrate the value of the application of Autogenic-Feedback Training Exercise (AFTE), a physiological training program developed by NASA to mitigate the impact of operational stressors such as motion sickness and spatial disorientation on human physiology and performance and 2) evaluate a new enhanced version of AFTE training software and demonstrate the ability to apply it remotely and train other personnel to administer it. AFTE combines principles of autogenic therapy, and biofeedback in training individuals to control their physiological reactions through a series of relaxation and arousal exercises. This study included twenty-six participants, 17 men and 9 women. On day 1 participants were tested in a rotating chair (pre-test) to determine their motion sickness tolerance (measured as minutes of rotation); days 2-5 consisted of four AFTE training sessions, each 30-min. in duration for a total of 2 hours; and on day 6 the participants were re-tested in the rotating chair. Results revealed a significant increase in motion sickness tolerance with AFTE on the post-test when compared to pre-test, participants had significantly lower symptom diagnostic scores post-test, and there was no significant gender effect. In addressing the first goal it was concluded that the modified 2-hour version of AFTE significantly improved motion sickness tolerance with participants experiencing fewer symptoms. A second goal of this research was to refine and transfer a NASA technology, software and methods for applications within DOD by training other personnel to administer AFTE. A comparison of NASA and NAMRU-D trainers on AFTE outcome for improving participants’ motion sickness tolerance revealed no significant difference indicating the successful transfer of methods to DOD. In addition, remote AFTE training of military aviators at distant sites was feasible. A third goal was to identify individual patterns of interoceptive abilities and related autonomic metrics able to predict stress response and training outcome. These data included measures of personality traits obtained from questionnaires and specific autonomic measures (e.g., heart rate variability) collected by NAMRU-D investigators. These results will be reported in a separate paper.

autonomic nervous system↗