Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the International Energy Agency Round Robin on Fast Pyrolysis Bio-oil Production

An international round robin study of the production of fast pyrolysis bio-oil was undertaken. Fifteen institutions in six countries contributed. Three biomass samples were distributed to the laboratories for processing in fast pyrolysis reactors. Samples of the bio-oil produced were transported to a central analytical laboratory for analysis. The round robin was focused on validating the pyrolysis community understanding of production of fast pyrolysis bio-oil by providing a common feedstock for bio-oil preparation. The round robin included: •distribution of 3 feedstock samples from a common source to each participating laboratory; •preparation of fast pyrolysis bio-oil in each laboratory with the 3 feedstocks provided; •return of the 3 bio-oil products (minimum 500 ml) with operational description to a central analytical laboratory for bio-oil property determination. The analyses of interest were: density, viscosity, dissolved water, filterable solids, CHN, S, trace element analysis, ash, total acid number, pyrolytic lignin, and accelerated aging of bio-oil. In addition, an effort was made to compare the bio-oil components to the products of analytical pyrolysis through GC/MS analysis. The results showed that clear differences can occur in fast pyrolysis bio-oil properties by applying different reactor technologies or configurations. The comparison to analytical pyrolysis method suggested that Py-GC/MS could serve as a rapid screening method for bio-oil composition when produced in fluid-bed reactors. Furthermore, hot vapor filtration generally resulted in the most favorable bio-oil product, with respect to water, solids, viscosity, and total acid number. These results can be helpful in understanding the variation in bio-oil production methods and their effects on bio-oil product composition.

09 BIOMASS FUELS↗

Operando video microscopy of Li plating and re-intercalation on graphite anodes during fast charging

Despite the demand for fast-charging lithium (Li)-ion batteries, high-energy-density batteries with thick graphite anodes are limited by Li plating when charging at >4C rates. In this work, plan-view operando video microscopy is applied on >3 mA h cm –2 calendared graphite electrodes to study the dynamic evolution of local state-of-charge (SoC) and Li plating during fast charging. This technique allows for visualization of the spatial heterogeneity in SoC across the electrode, nucleation and growth of Li filaments, Li re-intercalation into graphite, “dead Li” formation, and SoC equilibration. The operando microscopy analysis is complemented by ex situ imaging of through-plane gradients in SoC to gain a three-dimensional visualization of spatial heterogeneity. We demonstrate that (1) Li plating preferentially nucleates on the graphite particles that lithiate fastest during fast charging; (2) the onset of Li plating correlates with the local minimum of the graphite electrode potential; (3) galvanic corrosion currents are responsible for Li re-intercalation, dead Li formation, and SoC re-equilibration after fast charging; and (4) electrochemical signatures during OCV rest or discharge are associated with Li re-intercalation into graphite. Furthermore, this work provides insight into the Li–graphite interactions at the composite electrode level and can be used to inform strategies to diagnose and mitigate Li plating during fast charging.

25 ENERGY STORAGE↗

Use of Fast Ion D-Alpha diagnostics for understanding ICRF effects

Combined neutral beam injection and fast wave heating at cyclotron harmonics accelerate deuterium fast ions in the National Spherical Torus Experiment (NSTX) and in the DIII-D tokamak. Acceleration above the injected energy is evident in fast-ion D-alpha (FIDA) and volume-average neutron data. The FIDA diagnostic measures spatial profiles of the accelerated fast ions. In DIII-D, the acceleration is at a 4th or 5th cyclotron harmonic; the maximum enhancement in the high-energy FIDA signal is 8-10 cm beyond the resonance layer. In NSTX, acceleration is observed at five harmonics (7-11) simultaneously; overall, the profile of accelerated fast ions is much broader than in DIII-D. The energy distribution predicted by the CQL3D Fokker-Planck code agrees fairly well with measurements in DIII-D. However, the predicted profiles differ from experiment, presumably because the current version of CQL3D uses a zero-banana-width model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and modeling of Alfven eigenmode induced fast ion transport and loss in DIII-D and ASDEX Upgrade

Neutral beam injection into reversed magnetic shear DIII-D and ASDEX Upgrade plasmas produces a variety of Alfvenic activity including toroidicity-induced Alfven eigenmodes and reversed shear Alfven eigenmodes (RSAEs). These modes are studied during the discharge current ramp phase when incomplete current penetration results in a high central safety factor and increased drive due to multiple higher order resonances. Scans of injected 80 keV neutral beam power on DIII-D showed a transition from classical to AE dominated fast ion transport and, as previously found, discharges with strong AE activity exhibit a deficit in neutron emission relative to classical predictions. By keeping beam power constant and delaying injection during the current ramp, AE activity was reduced or eliminated and a significant improvement in fast ion confinement observed. Similarly, experiments in ASDEX Upgrade using early 60 keV neutral beam injection drove multiple unstable RSAEs. Periods of strong RSAE activity are accompanied by a large (peak {delta}S{sub n}/S{sub n{approx_equal}}60%) neutron deficit. Losses of beam ions modulated at AE frequencies were observed using large bandwidth energy and pitch resolving fast ion loss scintillator detectors and clearly identify their role in the process. Modeling of DIII-D loss measurements using guiding center following codes to track particles in the presence of ideal magnetohydrodynamic (MHD) calculated AE structures (validated by comparison to experiment) is able to reproduce the dominant energy, pitch, and temporal evolution of these losses. While loss of both co and counter current fast ions occurs, simulations show that the dominant loss mechanism observed is the mode induced transition of counter-passing fast ions to lost trapped orbits. Modeling also reproduces a coherent signature of AE induced losses and it was found that these coherent losses scale proportionally with the amplitude; an additional incoherent contribution scales quadratically with the mode amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of external axial magnetic field on fast electron propagation

A scheme employing an external axial magnetic field is proposed to diagnose the intrinsic divergence of laser-generated fast electron beams, and this is studied numerically with hybrid simulations. The maximum beam radius of fast electrons increases with the initial divergence and decreases with the amplitude of the axial magnetic field. It is indicated that the intrinsic divergence of fast electrons can be inferred from measurements of the beam radius at different depth under the axial field. The proposed scheme here may be useful for future fast ignition experiments and in other applications of laser-generated fast electron beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma-beta dependence of the fast reconnection mechanism in an initially force-free current sheet

The present paper systematically studies the spontaneous fast reconnection mechanism in an initially force-free current sheet in a wide range of plasma beta ({beta}); in our previous work it was studied for a special case of {beta} = 0.15. In each case, the evolution as well as the resulting structure of the fast reconnection is qualitatively similar to the one that was already reported for the case of {beta} = 0.15. Quantitatively, the fast reconnection evolution becomes more rapid and drastic for the lower plasma beta. For the cases of very low plasma beta ({beta} = 0.01 or 0.02), the plasma temperature is extremely enhanced to the value almost 1/{beta} times larger than its initial value in the resulting fast reconnection jet and large-scale plasmoid regions. Once the fast reconnection mechanism is ignited in a local spot-like region, its basic structure eventually established is sustained almost steadily, giving rise to the plasmoid swelling with time and propagating outwards. Accordingly, the characteristic reconnection regions, where plasma thermodynamic quantities are remarkably enhanced, rapidly expand in all (x, y, and z) directions in Alfven time scales, which may be responsible for the explosive expansion of large flares as well as for the distinct plasma heating observed in the solar corona.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast-ions on Alcator C-Mod: Comparisons between Simulation and Experiment for Equilibrium and Evolving Distributions

Analysis of fast-ion distributions >100 T{sub e} is important for both ITER and a fusion reactor, as both will have a significant population of fusion-born alpha particles. Furthermore, energetic ions may display transport properties that differ from the bulk plasma. It is imperative to benchmark current simulation codes with measurements of highly energetic fast-ions on current devices. Experimental measurements of ICRF heated H-minority plasmas on Alcator C-Mod are performed with an upgraded Compact Neutral Particle Analyzer (CNPA). The CNPA consists of vertically-viewing photodiode detectors with viewing chords from r/a = {approx}0.18 to 0.6 and energies from 150 keV to 1.5 MeV. The CNPA measurements are compared to the output of a synthetic diagnostic that has been added to the Fokker-Planck solver CQL3D. CQL3D is coupled with the full-wave solver AORSA to evolve a self-consistent fast-ion distribution. Good agreement is obtained between simulation and experiment for fast ion distributions that are in steady-state (df/dt = 0). However, there are discrepancies between the experimental and simulated results for the time-dependent evolution of the fast-ion distribution. A possible explanation of the discrepancy is due to violation of certain assumptions of quasi-linear theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elliptical magnetic mirror generated via resistivity gradients for fast ignition inertial confinement fusion

The elliptical magnetic mirror scheme for guiding fast electrons for Fast Ignition proposed by Schmitz et al. (Plasma Phys. Controlled Fusion 54, 085016 (2012)) is studied for conditions on the multi-kJ scale which are much closer to full-scale Fast Ignition. When scaled up, the elliptical mirror scheme is still highly beneficial to Fast Ignition. An increase in the coupling efficiency by a factor of 3–4 is found over a wide range of fast electron divergence half-angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D{sub 2}-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Collective Thomson Scattering measurements of fast ions at ASDEX upgrade

Understanding the behaviour of the confined fast ions is important in both current and future fusion experiments. These ions play a key role in heating the plasma and will be crucial for achieving conditions for burning plasma in next-step fusion devices. Microwave-based Collective Thomson Scattering (CTS) is well suited for reactor conditions and offers such an opportunity by providing measurements of the confined fast-ion distribution function resolved in space, time and 1D velocity space. We currently operate a CTS system at ASDEX Upgrade using a gyrotron which generates probing radiation at 105 GHz. A new setup using two independent receiver systems has enabled improved subtraction of the background signal, and hence the first accurate characterization of fast-ion properties. Here we review this new dual-receiver CTS setup and present results on fast-ion measurements based on the improved background characterization. These results have been obtained both with and without NBI heating, and with the measurement volume located close to the centre of the plasma. The measurements agree quantitatively with predictions of numerical simulations. Hence, CTS studies of fast-ion dynamics at ASDEX Upgrade are now feasible. The new background subtraction technique could be important for the design of CTS systems in other fusion experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Attractors of relaxation discrete-time systems with chaotic dynamics on a fast time scale

In this work, a new type of relaxation systems is considered. Their prominent feature is that they comprise two distinct epochs, one is slow regular motion and another is fast chaotic motion. Unlike traditionally studied slow-fast systems that have smooth manifolds of slow motions in the phase space and fast trajectories between them, in this new type one observes, apart the same geometric objects, areas of transient chaos. Alternating periods of slow regular motions and fast chaotic ones as well as transitions between them result in a specific chaotic attractor with chaos on a fast time scale. We formulate basic properties of such attractors in the framework of discrete-time systems and consider several examples. Finally, we provide an important application of such systems, the neuronal electrical activity in the form of chaotic spike-burst oscillations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas

To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the D{sub α} spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Action-angle formulation of generalized, orbit-based, fast-ion diagnostic weight functions

Due to the usually complicated and anisotropic nature of the fast-ion distribution function, diagnostic velocity-space weight functions, which indicate the sensitivity of a diagnostic to different fast-ion velocities, are used to facilitate the analysis of experimental data. Additionally, when velocity-space weight functions are discretized, a linear equation relating the fast-ion density and the expected diagnostic signal is formed. In a technique known as velocity-space tomography, many measurements can be combined to create an ill-conditioned system of linear equations that can be solved using various computational methods. However, when velocity-space weight functions (which by definition ignore spatial dependencies) are used, velocity-space tomography is restricted, both by the accuracy of its forward model and also by the availability of spatially overlapping diagnostic measurements. In this work, we extend velocity-space weight functions to a full 6D generalized coordinate system and then show how to reduce them to a 3D orbit-space without loss of generality using an action-angle formulation. Moreover, we show how diagnostic orbit-weight functions can be used to infer the full fast-ion distribution function, i.e., orbit tomography. In depth derivations of orbit weight functions for the neutron, neutral particle analyzer, and fast-ion D-α diagnostics are also shown

74 ATOMIC AND MOLECULAR PHYSICS↗

Transport and spatial energy deposition of relativistic electrons in copper-doped fast ignition plasmas

Fast electron transport and spatial energy deposition are investigated in integrated cone-guided Fast Ignition experiments by measuring fast electron induced copper K-shell emission using a copper tracer added to deuterated plastic shells with a geometrically reentrant gold cone. Experiments were carried out at the Laboratory for Laser Energetics on the OMEGA/OMEGA-EP Laser where the plastic shells were imploded using 54 of the 60 OMEGA60 beams (3ω, 20 kJ), while the high intensity OMEGA-EP (BL2) beam (1 ω, 10 ps, 500 J, I peak > 10 19 W/cm 2 ) was focused onto the inner cone tip. Here, a retrograde analysis using the hybrid-PIC electron transport code, ZUMA, is performed to examine the sensitivity of the copper Kα spatial profile on the laser-produced fast electrons, facilitating the optimization of new target point designs and laser configurations to improve the compressed core areal density by a factor of 4 and the fast electron energy coupling by a factor of 3.5.

42 ENGINEERING↗

Particle-in-cell studies of fast-ion slowing-down rates in cool tenuous magnetized plasma

We report on 3D-3V particle-in-cell simulations of fast-ion energy-loss rates in a cold, weakly-magnetized, weakly-coupled plasma where the electron gyroradius, ρe, is comparable to or less than the Debye length, λ De , and the fast-ion velocity exceeds the electron thermal velocity, a regime in which the electron response may be impeded. These simulations use explicit algorithms, spatially resolve ρ e and λ De , and temporally resolve the electron cyclotron and plasma frequencies. For mono-energetic dilute fast ions with isotropic velocity distributions, these scaling studies of the slowing-down time, τ s , versus fast-ion charge are in agreement with unmagnetized slowing-down theory; with an applied magnetic field, no consistent anisotropy between τs in the cross-field and field-parallel directions could be resolved. Scaling the fast-ion charge is confirmed as a viable way to reduce the required computational time for each simulation. In conclusion, the implications of these slowing down processes are described for one magnetic-confinement fusion concept, the small, advanced-fuel, field-reversed configuration device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of fast and thermal neutron irradiation on Ga-polar and N-polar GaN diodes

Studies of the radiation tolerance and electrical behavior of gallium nitride (GaN) based devices are important for the next generation of high-power and high-voltage electronics that may be subjected to harsh environments such as nuclear reactor and fusion facilities, particle accelerators, and post-denotation environments. Here, in this work, we study the behavior of Ga-polar and N-polar GaN Schottky diodes before and after exposure to fast and thermal + fast neutrons. Temperature-dependent current–voltage (I–V) and circular transmission line method (CTLM) measurements were used to study the electrical characteristics. A strong reduction in reverse leakage current and an increase in differential resistance in forward bias were observed after neutron irradiation. Thermionic emission (TE), Frenkel–Poole (FP) emission, and Fowler–Nordheim (FN) tunneling models were used to explain the forward and reverse I–V characteristics pre- and post-irradiation. The study confirms that Ga-polar and N-polar GaN Schottky diodes exhibit different electrical responses to fast and thermal neutron irradiations. The reverse bias characteristics of N-polar diodes are less affected after the fast neutron irradiation compared to Ga-polar diodes, while in the forward bias region, the electrical behavior after fast and thermal neutron irradiations is similar in Ga-polar and N-polar diodes. The results indicate that the role of orientation should be considered in the design of GaN-based radiation-tolerant electronics.

42 ENGINEERING↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗