Revisiting spontaneous Raman scattering for direct oxygen atom quantification

In this paper, the counterintuitive and largely unknown Raman activity of oxygen atoms is evaluated for its capacity to determine absolute densities in gases with significant O-density. The study involves C O 2 microwave plasma to generate a self-calibrating mixture and establish accurate cross sections for the 3 P 2 ↔<!-- ↔ --> 3 P 1 and 3 P 2 ↔<!-- ↔ --> 3 P 0 transitions. The approach requires conservation of stoichiometry, confirmed within experimental uncertainty by a 1D fluid model. The measurements yield σ<!-- σ --> J = 2 →<!-- → --> 1 = 5.27 ±<!-- ± --> s y s : 0.53 r a n d : 0.17 ×<!-- × --> 10 -<!-- - --> 31 c m 2 / s r and σ<!-- σ --> J = 2 →<!-- → --> 0 = 2.11 ±<!-- ± --> s y s : 0.21 r a n d : 0.06 ×<!-- × --> 10 -<!-- - --> 31 c m 2 / s r , and the detection limit is estimated to be 1 ×<!-- × --> 10 15 c m -<!-- - --> 3 for systems without other scattering species.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous imaging of two-phase velocities in particle-laden flows by two-color optical phase discrimination

In this Letter, we present a particle image/tracking velocimetry (PIV/PTV) technique for simultaneous velocity measurement of both fluid and particle phases, adopting newly developed optical phase discrimination methods and novel optical particles. Spherical acrylic (PMMA) particles of diameter ∼ <#comment/> O ( 100 µ <#comment/> m ) were used as the particle phase, while fine B A M : E u 2 + phosphors of diameter ∼ <#comment/> O ( 1 µ <#comment/> m ) were used as the fluid tracer. Under Nd:YAG 355 nm laser excitation, both the laser-induced fluorescence (LIF) from PMMA and laser-induced phosphorescence (LIP) from B A M : E u 2 + provided sufficiently strong signals for PIV imaging with two non-intensified cameras and were clearly separable for phase discrimination using spectral filters and temporal profiles. The advantages of the PIV/PTV method include the relatively low cost of B A M : E u 2 + phosphors, high sphericity and narrow size distribution of PMMA particles with LIF emission, and direct optical discrimination eliminating artifacts, while requiring much less computational capacity for PIV/PTV processing of complex particle-laden flows.

Bi, Xiaopeng (ORCID:0000000190847325)↗

Bladder cancer cells secrete while normal bladder cells express but do not secrete AGR2

Anterior gradient 2 (AGR2) is a cancer-associated secreted protein found predominantly in adenocarcinomas. Given its ubiquity in solid tumors, cancer-secreted AGR2 could be a useful biomarker in urine or blood for early detection. Normal organs express AGR2 and might also secrete AGR2, which would impact on the utility of AGR2 as a cancer biomarker. Uniform AGR2 expression is found in the normal bladder urothelium. Little AGR2 is, however, secreted by the urothelial cells as no measurable amounts could be detected in urine. The urinary proteomes of healthy people contain no listing for AGR2. The blood proteomes also contain no significant peptide counts for AGR2 suggesting that little urothelial secretion into capillaries of the lamina propria. Expression is lost in urothelial carcinoma, but 25% primary tumors retained AGR2 expression in a cohort of lymph node positive cases. AGR2 is secreted by the urothelial carcinoma cells as urinary AGR2 was measured in the voided urine of 25% of the cases analyzed in a cohort of cancer vs. non-cancer urine, which matched the frequency of AGR2-positive urothelial carcinoma. Since cancer cells secrete AGR2 while normal cells do not, its measurement in body fluids could be used to indicate tumor presence. In addition to secretion, AGR2 is also localized to the cell surface. Thus, secretion/cell surface localization of AGR2 is pecific to cancer while expression itself is not. Lastly, since AGR2 is found in many solid tumor types, this tumor-associated antigen constitutes a highly promising therapeutic target.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Mach number on Richtmyer-Meshkov mixing and transition

The Richtmyer-Meshkov (R-M) instability is an important process that governs fluid mixing in engineering applications where shock waves are present. As the instability grows in time, the flow may eventually transition to a turbulent state with a broad range of relevant length scales and complicated flow features on a very short time scale, making it a challenging problem to investigate both experimentally and numerically. Experiments are performed to study the effect of incident shock Mach number (M) on the development of the R-M instability after a shock wave impulsively accelerates a varicose-perturbed, heavy-gas curtain (air-SF6-air). The resulting instability and subsequent fluid mixing is measured using simultaneous Planar Laser-Induced Fluorescence (PLIF) and Particle Image Velocimetry (PIV). The implementation of both of these diagnostics is particularly important for the study of variable density flows in which the scalar mixing state actively modulates the flow dynamics. Turbulence in variable density flows is therefore more complicated, and our understanding is limited compared to more classical turbulence problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Milone eTape Liquid Level Sensor Laboratory Calibration with a Commercial 12.2 cm HS-Flume and 3D Printed 4 cm Micro-HS-Flumes

The NGEE Arctic Rainfall Simulator (NARS) is a variable intensity rainfall simulator (RFS) with a frame design based on the Humphry et al. (2002) RFS and a water delivery system based on the Walnut Gulch (Paige et al., 2004) RFS. The NARS uses an aluminum frame that is fully deconstructable for transportation to field locations and a water system that enables variable rain intensity. Prior to field deployment, H-flume discharge and the corresponding Milone eTape Liquid Level Sensor (eTape) resistance values were measured in the laboratory so that discharge measurements from the NGEE Arctic Rainfall Simulator could be automated. eTape resistance was measured with increasing fluid heights for the full range of the eTape to calculate sensor detection limits and resolution. The eTape was calibrated to both a commercially available 12.2 cm HS-flume and a 3D printed 4 cm Micro-HS-flume. This data package contains two .csv files, one for the eTape calibration and the other for the flume calibrations, and two .stl files to 3D print the 4 cm Micro-HS-Flume design with a 1 cm x 3.6 cm stilling well opening. The .stl files can be opened in most 3D printing or CAD programs/software. Two .kml files of the laboratory location and broader area where testing was conducted are also included in this data package.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Laser velocimeter with transverse and on-axis sensitivity

Laser Doppler velocimeters are used for measurement of localized fluid velocities without perturbation of flow field. Technique which utilizes only two outgoing beams polarized normally to one another can be processed in such a manner that local oscillator signal is obtained and usual dual-scatter velocity is also retrieved.

Orloff, K. L.↗

Hematological Viscometry

Concepts and defining equations for the design of a relative velocity blood viscometer are reported. The device consists of two cone and plate chambers, a variable speed drive, and rotational velocity detectors. Two con-plate systems are directly coupled with one system driving the other through the viscous drag transmitted in the test fluid. Angular velocity measurements are processed electronically. A brief description of current viscometer designs is included.

West, D. R.↗

The dynamic behavior and compliance of a stream of cavitating bubbles.

Study of the dynamic response of streams of cavitating bubbles to imposed pressure fluctuations to determine the role played by turbopump cavitation in the POGO instability of liquid rockets. Both quasi-static and more general linearized dynamic analyses are made of the perturbations to a cavitating flow through a region of reduced pressure in which the bubbles first grow and then collapse. The results, when coupled with typical bubble number density distribution functions, yield compliances which compare favorably with the existing measurements. Since the fluids involved are frequently cryogenic, a careful examination was made of the thermal effects both on the mean flow and on the perturbations. As a result, the discrepancy between theory and experiment for particular engines could be qualitatively ascribed to reductions in the compliance caused either by these thermal effects or by relatively high reduced frequencies.

Brennen, C.↗

Experimental and analytical investigation of flow through rocket pump inducer

The characteristics of a rocket pump inducer are discussed. The effect of the pumping requirements on the blade configuration is analyzed. The effects of viscosity on blade design were determined by tests of a four bladed inducer operated in air at a flow coefficient of 0.065. The fluid properties were measured at the exit of the inducer using conventional and hot wire probes. The experimental results and the method of predicting the outlet tangential velocity and head rise are discussed.

Lakshminarayana, B.↗

Medical Support and Findings of the Skylab Program

Specific equipment used in carrying out Skylab medical experiments is outlined and illustrated. Also included are reviews of the techniques, frequency, and protocols of the tests designed to study the long term effects of weightlessness on the human body. In-flight investigations were an evaluation of the cardiovascular system, a study of metabolic activity, investigations in the field of neurophysiology, the determination of changes in body fluids, a precise measurement of total body metabolism, and a study of crew performance by use of a time and motion experiment. Significant data obtained from in-flight and postflight tests are outlined.

Johnston, Richard S.↗

Tube-bending scale/protractor

Combination protractor and scale for measuring tube bends has novel pivot that allows tube to remain in contact with scale arms for all bend angles. Device permits rapid and accurate scribing and measurement of mockup fluid lines to obtain production data.

Millett, A. U.↗

Liquid solar collector

Report documents evaluation test on commercial flat-plate solar collector that uses water as working fluid. Performance was measured before and after 34-day exposure to natural environment. Tables in metric and English units present data on air and water temperatures, waterflow, insolation, efficiency, and windspeed and direction.

Source record↗

An analytical tool for simulating Large AMplitude Propellant Slosh

The development of a multiple-mass, nonlinear, finite-element analytical model - the Large AMplitude Propellant Slosh model (LAMPS) in two- and three-dimensional versions, is described. The model is used in predicting the forces on the Space Shuttle external tank caused by large amplitude motion of propellant fluid. Comparisons between measured propellant reorientation forces and those predicted by the LAMPS models are presented, and it is concluded that the model provides a cost effective, experimentally verified approach to a complicated nonlinear problem.

Berry, R. L.↗

Circulation control lift generation experiment: Hardware development

A circulation control airfoil and its accompanying hardware were developed to allow the investigation of lift generation that is independent of airfoil angle of attack and relative flow velocity. The test equipment, designed for use in a water tunnel, includes the blown airfoil, the support systems for both flow visualization and airfoil load measurement, and the fluid control system, which utilizes hydraulic technology. The primary design tasks, the selected solutions, and the unforseen problems involved in the development of these individual components of hardware are described.

Panontin, T. L.↗

Retrofitting avionics - Closing the performance 'Generation gap'

The retrofitting of advanced avionics to in-service aircraft in order to increase operational safety and flexibility, and reduce operating costs is analyzed. Research in flight management planning and airborne guidance for full-and cost-effective flight is examined. The use of CRTs and thin film electroluminescent displays in aircraft is described. The development of more accurate and reliable fuel gauges using nuclear-based techniques or volumetric measurements to evaluate fluid levels is studied. Advances in airspace systems, such as the Microwave Landing System, and Air Traffic Control Beacon System/Select Mode, the Traffic Advisory and Collision Advance System, and satellite-based communications, navigation, and surveillance are discussed.

Spitzer, C. R.↗

Onset of surface-tension-driven Benard convection

An experimental investigation of the onset of convection in shallow fluid layers heated uniformly from below and cooled from above by an air layer has been made. If the depth of the silicone layer is smaller than 2 mm the onset of convection takes place in two stages. There is first a weak pattern, which is characterized by its appearance at ever smaller temperature gradients as the depth of the fluid is decreased. When the temperature difference across the fluid is increased a second strong pattern forms near the predicted critical Marangoni number. The cells in this pattern are hexagonal and seem to be what one has always referred to as Benard cells. The temperature gradient at which this pattern appears increases with decreased depth. The heat transfer through the fluid has been measured. The critical temperature gradient for the formation of the hexagonal pattern has been determined from the break of the heat transfer curve.

Koschmieder, E. L.↗