Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Derivation of Mortal Injury Metric for Studies of Rapid Decompression of Depth-Acclimated Physostomous Fish

In 2005 the U.S. Army Corps of Engineers (USACE) began a study to investigate the response of hatchery and run-of-the-river (ROR) juvenile Chinook salmon to the effects of rapid decompression during passage through mainstem Federal Columbia River Power System (FCRPS) Kaplan turbines. In laboratory studies conducted by Pacific Northwest National Laboratory (PNNL) for USACE since 2005, juvenile fish have been exposed to rapid decompression in a barometric pressure chamber. An initial study considered the response of juvenile Chinook salmon bearing radio transmitters to rapid decompression resulting from exposure to a pressure time history simulating the worst case condition that might be experienced during passage through an operating turbine. The study in 2005 found that acclimation depth was a very important treatment factor that greatly influenced the significantly higher incidence of injury and mortality of rapidly decompressed Chinook salmon bearing radio telemetry devices. In 2006 we initiated a statistical investigation using data in hand into derivation of a new end-point measure for assessment of the physiological response of juvenile Chinook salmon to rapid decompression. Our goal was a measure that would more fully utilize both mortality and injury data while providing a better assessment of the most likely survival outcome for juvenile physostomous fish exposed to rapid decompression. The conclusion of the analysis process was to classify fish as mortally injured when any of the 8 injuries are present, regardless of whether the fish was last observed alive or not. The mortally injured classification has replaced mortality as the end point metric for our rapid decompression studies. The process described in this report is an example of how a data set may be analyzed to identify decision criterion for objective classification of test fish to a specific end-point. The resulting list of 8 mortal injuries is applicable to assess injuries from rapid decompression and is currently being applied to ongoing studies. We intend to update this analysis as more data becomes available and to extend it to ROR Chinook salmon smolt. The method itself is applicable to other injury and mortality data for juvenile salmonids from laboratory and field studies related to all dam passage routes and for collision, strike, and shear injuries in addition to decompression.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Hybrid-Clustering and Localized Regression for Time Synchronization of a Hierarchical Underwater Acoustic Sensor Array

Time synchronization is a critical requirement for the application of underwater acoustic sensor network (UWSN). Although a number of time synchronization protocols have been proposed for UWSN, none of them can be directly applied to autonomous acoustic receivers due to lack of hardware platform to communicate with each other. In this paper, we propose a machine learning-based time synchronization framework for autonomous receiver arrays, using the Juvenile Salmon Acoustic Telemetry System as a case study. The proposed framework consists of array partition and time synchronization. Using detections of receiver attached beacons as input, this framework synchronizes all receiver clocks to a root receiver clock. The framework has been successfully used in a field study at Trevallyn Dam forebay in Tasmania, Australia.

Fu, Tao↗

Soybean fallow and nitrification inhibitors: Strategies to reduce N 2 O emission intensities and N losses in Australian sugarcane cropping systems

The Australian sugar industry is facing mounting pressure to reduce the nitrogen (N) losses and nitrous oxide (N 2 O) emissions associated with N fertiliser use. Research has shown that N 2 O emissions from sugarcane (Saccharum officinarum L.) cropping systems can be reduced with the use of fertilisers coated with nitrification inhibitors, or by sowing legume crops in the fallows between sugarcane crop cycles. However, the efficacy of these two N management strategies across different climatic zones is still unclear, as results from field studies have been contradictory. The objectives of this study were therefore to use the DayCent model to assess the long-term effects of the two strategies (separately or in combination) on N 2 O emissions, N losses and yields. The model was parameterised using data from eight field experiments (39 treatments) conducted across four of the five main districts of the Australian sugarcane industry. A series of long-term scenarios embracing a range of N fertiliser rates (0- 160 kg N ha -1 applied as urea), climatic regions (Tropics and Subtropics), soil textures (fine- and coarse-textured soils) and N-loss risk scenarios (crop fertilised well before or close to the on-set of the wet season) were tested for both N management strategies. Simulations identified that the combined use of soybean (Glycine max L.) fallows and N fertiliser coated with the 3,4-dimethylpyrazole phosphate (DMPP) nitrification inhibitor was the most effective strategy to maintain or even increase current yields while significantly reducing N 2 O and cumulative N (mainly due to nitrate) losses. When used alone, the soybean fallow strategy on average reduced N losses over the entire crop cycle by 29 % compared with current industry best practice. However, this strategy showed a limited capacity to reduce N 2 O emissions over the entire cane crop cycle (median: -3% compared with current industry best practice), or even increased them in scenarios at high-risk of N losses in the Tropics. The use of urea coated with DMPP alone allowed current fertiliser N rates to be reduced by 30 % without any substantial yield penalty. In environments prone to high N losses, DMPP urea abated overall N losses and N 2 O emissions by 41 % and 30 %, respectively. This was the first study to use such an extensive dataset to parameterise a biogeochemical model for yields, N 2 O emissions and N losses in sugarcane cropping systems. Finally, the findings will be instrumental in guiding future research and policies designed to improve the profitability and environmental sustainability of this industry.

54 ENVIRONMENTAL SCIENCES↗

CARES: Carbonaceous Aerosol and Radiative Effects Study Science Plan

Carbonaceous aerosol components, which include black carbon (BC), urban primary organic aerosols (POA), biomass burning aerosols, and secondary organic aerosols (SOA) from both urban and biogenic precursors, have been previously shown to play a major role in the direct and indirect radiative forcing of climate. The primary objective of the CARES 2010 intensive field study is to investigate the evolution of carbonaceous aerosols of different types and their effects on optical and cloud formation properties.

54 ENVIRONMENTAL SCIENCES↗

Quantum Monte Carlo study of a two-species bosonic Hubbard model

We consider a two-species hard-core boson Hubbard model for a supersolid, where two types of bosons represent vacancies and interstitials doped into a commensurate crystal. The on-site interspecies interaction can create bound states of vacancies and interstitials facilitating vacancy condensation at lower energies than in a single-species model, as suggested in an earlier mean-field study. Here, we carry out quantum Monte Carlo simulations to study possible supersolid phases of the model, which correspond to superfluid phases of the vacancies or interstitials. At low temperatures, we find three distinct superfluid phases. The extent of the phases and the nature of the phase transitions are discussed in comparison to mean-field theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental warming advances phenology of groundlayer plants at the boreal‐temperate forest ecotone

Premise of the Study Changes to plant phenology have been linked to warmer temperatures caused by climate change. Despite the importance of the groundlayer to community and forest dynamics, few warming experiments have focused on herbaceous plant and shrub phenology. Methods Using a field study in Minnesota, United States, we investigated phenological responses of 16 species to warming over five growing seasons (2009–2013) at two sites, under two canopy covers, and in three levels of simultaneous above‐ and belowground warming: ambient temperature, ambient +1.7°C and ambient +3.4°C. We tested whether warming led to earlier phenology throughout the growing season and whether responses varied among species and years and depended on canopy cover. Key Results Warming extended the growing season between 11–30 days, primarily through earlier leaf unfolding. Leaf senescence was delayed for about half of the species. Warming advanced flowering across species, especially those flowering in August, with modest impacts on fruit maturation for two species. Importantly, warming caused more than half of the species to either converge or diverge phenologically in relation to each other, suggesting that future warmed climate conditions will alter phenological relationships of the groundlayer. Warm springs elicited a stronger advance of leaf unfolding compared to cool spring years. Several species advanced leaf unfolding (in response to warming) more in the closed canopy compared to the open. Conclusions Climate warming will extend the growing season of groundlayer species in the boreal‐temperate forest ecotone and alter the synchrony of their phenology.

Rice, Karen E.↗

Two-dimensional particle-in-cell simulations of transport in a magnetized electronegative plasma

Particle transport in a uniformly magnetized electronegative plasma is studied in two-dimensional (2D) geometry with insulating (dielectric) boundaries. A 2D particle-in-cell (PIC) code is employed, with the results compared to analytic one-dimensional models that approximate the end losses as volume losses. A modified oxygen reaction set is used to scale to the low densities used in PIC codes and also to approximately model other gases. The principal study is the limiting of the transverse electron flow due to strong electron magnetization. The plasma in the PIC calculation is maintained by axial currents that vary across the transverse dimension. For a cosine current profile nearly uniform electron temperature is obtained, which at the B-fields studied (600-1200 G) give a small but significant fraction (0.25 or less) of electron to negative ion transverse loss. For a more transverse-confined current, and approximating the higher mass and attachment reaction rate of iodine, the fraction of electron to negative ion transverse loss can be made very small. The models which have been constructed reasonably approximate the PIC results and indicate that the cross-field transport is nearly classical.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Healthy Zero Energy Buildings (HZEB) Program Interim Report on Cross Sectional Study of Contaminant Levels, Source Strengths, and Ventilation Rates in Retail Stores

The HZEB research program aims to generate information needed to develop new science-based commercial building ventilation rate (VR) standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. This interim report describes the preliminary results from one HZEB field study on retail stores. The primary purpose of this study is to estimate the whole-building source strengths of contaminant of concerns (COCs). This information is needed to determine the VRs necessary to maintain indoor concentrations of COCs below applicable health guidelines.The goal of this study is to identify contaminants in retail stores that should be controlled via ventilation, and to determine the minimum VRs that would satisfy the occupant health and odor criteria.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optical Microscopy Study of Soiling on Photovoltaic Glass: Evaluation of Mitigation Strategies

The natural soiling of photovoltaic cover glass has recently been shown to include both inorganic and organic particulate matter. Under favorable growth conditions, the latter can lead to the growth of dense colonies of filamentous fungi, potentially leading to measurable performance losses over time. Herein, we report on a field study where glass coupon samples were deployed in soiling-prone locations, focusing on Dubai (United Arab Emirates) and Mumbai (India). For each site location, clear differences in the soiling were observed. The samples from Mumbai were contaminated with an abundance of filamentous fungi whereas the samples from Dubai had primarily inorganic contamination. The effectiveness of soiling mitigation strategies, including cleaning techniques and glass coatings, are discussed in detail.

14 SOLAR ENERGY↗

Characterization of a real-time tracer for isoprene epoxydiols-derived secondary organic aerosol (IEPOX-SOA) from aerosol mass spectrometer measurements

Substantial amounts of secondary organic aerosol (SOA) can be formed from isoprene epoxydiols (IEPOX), which are oxidation products of isoprene mainly under low-NO conditions. Total IEPOX-SOA, which may include SOA formed from other parallel isoprene oxidation pathways, was quantified by applying positive matrix factorization (PMF) to aerosol mass spectrometer (AMS) measurements. The IEPOX-SOA fractions of organic aerosol (OA) in multiple field studies across several continents are summarized here and show consistent patterns with the concentration of gas-phase IEPOX simulated by the GEOS-Chem chemical transport model. During the Southern Oxidant and Aerosol Study (SOAS), 78 % of PMF-resolved IEPOX-SOA is accounted by the measured IEPOX-SOA molecular tracers (2-methyltetrols, C5-Triols, and IEPOX-derived organosulfate and its dimers), making it the highest level of molecular identification of an ambient SOA component to our knowledge. An enhanced signal at C 5 H 6 O + (m/z 82) is found in PMF-resolved IEPOX-SOA spectra. To investigate the suitability of this ion as a tracer for IEPOX-SOA, we examine f C 5 H 6 O ( f C 5 H 6 O= C 5 H 6 O + /OA) across multiple field, chamber, and source data sets. A background of ~ 1.7 ± 0.1 ‰ (‰ = parts per thousand) is observed in studies strongly influenced by urban, biomass-burning, and other anthropogenic primary organic aerosol (POA). Higher background values of 3.1 ± 0.6 ‰ are found in studies strongly influenced by monoterpene emissions. The average laboratory monoterpene SOA value (5.5 ± 2.0 ‰) is 4 times lower than the average for IEPOX-SOA (22 ± 7 ‰), which leaves some room to separate both contributions to OA. Locations strongly influenced by isoprene emissions under low-NO levels had higher f C 5 H 6 O (~ 6.5 ± 2.2 ‰ on average) than other sites, consistent with the expected IEPOX-SOA formation in those studies.f C 5 H 6 O in IEPOX-SOA is always elevated (12–40 ‰) but varies substantially between locations, which is shown to reflect large variations in its detailed molecular composition. The low f C 5 H 6 O (< 3 ‰) reported in non-IEPOX-derived isoprene-SOA from chamber studies indicates that this tracer ion is specifically enhanced from IEPOX-SOA, and is not a tracer for all SOA from isoprene. We introduce a graphical diagnostic to study the presence and aging of IEPOX-SOA as a triangle plot of fCO2 vs. f C 5 H 6 O. Finally, we develop a simplified method to estimate ambient IEPOX-SOA mass concentrations, which is shown to perform well compared to the full PMF method. The uncertainty of the tracer method is up to a factor of ~ 2, if the f C 5 H 6 O of the local IEPOX-SOA is not available. When only unit mass-resolution data are available, as with the aerosol chemical speciation monitor (ACSM), all methods may perform less well because of increased interferences from other ions at m/z 82. This study clarifies the strengths and limitations of the different AMS methods for detection of IEPOX-SOA and will enable improved characterization of this OA component.

Hu, W. W.↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Core/Shell-Like Localized Emission at Atomically Thin Semiconductor–Au Interface

Localized emission in atomically thin semiconductors has sparked significant interest as single-photon sources. Despite comprehensive studies into the correlation between localized strain and exciton emission, the impacts of charge transfer on nanobubble emission remains elusive. Here, in this paper, we report the observation of core/shell-like localized emission from monolayer WSe 2 nanobubbles at room temperature through near-field studies. By altering the electronic junction between monolayer WSe 2 and the Au substrate, one can effectively adjust the semiconductor to metal junction from a Schottky to an Ohmic junction. Through concurrent analysis of topography, potential, tip-enhanced photoluminescence, and a piezo response force microscope, we attribute the core/shell-like emissions to strong piezoelectric potential aided by induced polarity at the WSe 2 –Au Schottky interface which results in spatial confinement of the excitons. Our findings present a new approach for manipulating charge confinement and engineering localized emission within atomically thin semiconductor nanobubbles. These insights hold implications for advancing the nano and quantum photonics with low-dimensional semiconductors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Vertically Resolved Canopy Improves Chemical Transport Model Predictions of Ozone Deposition to North Temperate Forests

Abstract Dry deposition is the second largest tropospheric ozone (O 3 ) sink and occurs through stomatal and nonstomatal pathways. Current O 3 uptake predictions are limited by the simplistic big‐leaf schemes commonly used in chemical transport models (CTMs) to parameterize deposition. Such schemes fail to reproduce observed O 3 fluxes over terrestrial ecosystems, highlighting the need for more realistic treatment of surface‐atmosphere exchange in CTMs. We address this need by linking a resolved canopy model (1D Multi‐Layer Canopy CHemistry and Exchange Model, MLC‐CHEM) to the GEOS‐Chem CTM and use this new framework to simulate O 3 fluxes over three north temperate forests. We compare results with in situ measurements from four field studies and with standalone, observationally constrained MLC‐CHEM runs to test current knowledge of O 3 deposition and its drivers. We show that GEOS‐Chem overpredicts observed O 3 fluxes across all four studies by up to 2×, whereas the resolved‐canopy models capture observed diel profiles of O 3 deposition and in‐canopy concentrations to within 10%. Relative humidity and solar irradiance are strong O 3 flux drivers over these forests, and uncertainties in those fields provide the largest remaining source of model deposition biases. Flux partitioning analysis shows that: (a) nonstomatal loss accounts for 60% of O 3 deposition on average; (b) in‐canopy chemistry makes only a small contribution to total O 3 fluxes; and (c) the CTM big‐leaf treatment overestimates O 3 ‐driven stomatal loss and plant phytotoxicity in these temperate forests by up to 7×. Results motivate the application of fully online vertically explicit canopy schemes in CTMs for improved O 3 predictions.

Vermeuel, Michael P. [Department of Soil, Water, a↗

Eucalyptus Are Unlikely to Escape Plantations and Invade Surrounding Forests Managed with Prescribed Fire in Southeastern US

Woody biomass production can increase through establishment of non-native tree species exhibiting greater growth potential than traditional native species. Interest in growing Eucalyptus in the southeastern US has raised concern over its potential spread and invasion, which could impact ecosystem properties and functions. Within the matrix of land use where Eucalyptus establishment is being considered in the southeastern US, surrounding pine forests managed with fire represent a likely pathway for invasion. We used greenhouse and field experiments to evaluate the potential invasion risk of Eucalyptus benthamii. We were specifically interested in determining if seeds could successfully germinate in fire-maintained pine forests and if fire-return intervals influenced germination through impacts on litter accumulation and light availability. The greenhouse experiment investigated the influence of light availability on germination success, whereas the field study investigated the influence of time since fire, and thus litter accumulation and light availability, on germination success. Percent germination was similar under non-shaded controls and moderate shade, but complete shade resulted in low germination rates. Germination was lower in the field compared to the greenhouse and was influenced by litter and light availability, which varied according to fire-return intervals. Litter increased, and light availability decreased, with time since burn. Germination was negatively related to litter depth and positively related to light availability, thereby decreasing with time since fire. Germination increased with litter removal but remained positively related to light availability after litter removal. Higher germination with litter removal suggests germination is influenced by litter, but higher germination with increased light availability, regardless of raking, suggests germination is also influenced by light availability. Despite these relationships, no seedlings persisted through the growing season. The low germination rates under a variety of field conditions coupled with the lack of persistence suggests establishment may be unlikely, regardless of the surrounding land matrix.

54 ENVIRONMENTAL SCIENCES↗

Experimental Testing Scale Considerations for the Investigation of Bare‐Soil Evaporation Dynamics in the Presence of Sustained Above‐Ground Airflow

Abstract At the fundamental process level, many of the concepts that form the foundation of our understanding of bare‐soil evaporation dynamics have advanced little since their initial formation. This investigation explores experimental scaling issues that should be considered during the study of bare‐soil evaporation dynamics under conditions of sustained above‐ground airflow. Results are presented from a series of large‐scale laboratory experiments conducted for various soil conditions (i.e., heterogeneity and surface roughness). Fundamental experimental research of this nature is not feasible in the field or small laboratory columns that are limited by system control and scale. All experimentation was therefore conducted in a test facility that couples a climate‐controlled, low‐speed wind tunnel with a 7.15‐m‐long soil tank—allowing for control over soil properties and initial and boundary conditions. Measured flow phenomena supported, and agreed well with, existing wind tunnel and field study literature. These data were in turn, used to explain observed evaporative water loss and soil moisture distribution spatiotemporal trends and patterns. Results demonstrated that relatively large length scales are required for the impacts of atmospheric feedbacks on the subsurface hydrodynamics to manifest themselves and become quantifiable. Airflow had the greatest impact in the case of a flat homogeneous soil; the strength of this feedback was significantly weaker in the presence of soil heterogeneities and surface undulations that were dominated by other transport phenomena. Comparison of these results with those of past studies furthermore cautions against the use of column scale data to make generalizations about bare‐soil evaporation dynamic upscaling.

Trautz, Andrew C.↗

Evidence for compensatory photosynthetic and yield response of soybeans to aphid herbivory

The soybean aphid, Aphis glycines Matsumura, an exotic species in North America that has been detected in 21 U.S. states and Canada, is a major pest for soybean that can reduce maximum photosynthetic capacity and yields. Our existing knowledge is based on relatively few studies that do not span a wide variety of environmental conditions, and often focus on relatively high and damaging population pressure. We examined the effects of varied populations and duration of soybean aphids on soybean photosynthetic rates and yield in two experiments. In a 2011 field study, we found that plants with low cumulative aphid days (CAD, less than 2,300) had higher yields than plants not experiencing significant aphid pressure, suggesting a compensatory growth response to low aphid pressure. This response did not hold at higher CAD, and yields declined. In a 2013 controlled-environment greenhouse study, soybean plants were well-watered and fertilized with nitrogen (N), and aphid populations were manipulated to reach moderate to high levels (8,000–50,000 CAD). Plants tolerated these population levels when aphids were introduced during the vegetative or reproductive phenological stages of the plant, showing no significant reduction in yield. Leaf N concentration and CAD were positively and significantly correlated with increasing ambient photosynthetic rates. Our findings suggest that, given the right environmental conditions, modern soybean plants can withstand higher aphid pressure than previously assumed. Moreover, soybean plants also responded positively through a compensatory photosynthetic effect to moderate population pressure, contributing to stable or increased yield.

54 ENVIRONMENTAL SCIENCES↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗