Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Effect of Local Void Fractions on Subcooled Boiling Oscillations in Natural Circulation Boiling Loop

Passive heat removal using natural circulation boiling loops (NCBLs) is well established from the view point of the safety of boiling water reactors (BWRs). Nevertheless, NCBLs suffer from a large number of nonlinear flow oscillations due to low driving force for circulations. The local measurements of void fraction a are essential to clearly understand the mechanism of flow oscillations. In this work, we have measured the impedance from the needle probe using LCR meter and quantified time-averaged local a from the measured impedance under oscillating flow conditions in the NCBL. Impedance probes have been successfully used in estimating void fractions and bubble frequencies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Metrics for Assessment of Smart Grid Data Integrity Attacks

There is an emerging consensus that the nation’s electricity grid is vulnerable to cyber attacks. This vulnerability arises from the increasing reliance on using remote measurements, transmitting them over legacy data networks to system operators who make critical decisions based on available data. Data integrity attacks are a class of cyber attacks that involve a compromise of information that is processed by the grid operator. This information can include meter readings of injected power at remote generators, power flows on transmission lines, and relay states. These data integrity attacks have consequences only when the system operator responds to compromised data by redispatching generation under normal or contingency protocols. These consequences include (a) financial losses from sub-optimal economic dispatch to service loads, (b) robustness/resiliency losses from placing the grid at operating points that are at greater risk from contingencies, and (c) systemic losses resulting from cascading failures induced by poor operational choices. This paper is focused on understanding the connections between grid operational procedures and cyber attacks. We first offer two examples to illustrate how data integrity attacks can cause economic and physical damage by misleading operators into taking inappropriate decisions. We then focus on unobservable data integrity attacks involving power meter data. These are coordinated attacks where the compromised data are consistent with the physics of power flow, and are therefore passed by any bad data detection algorithm. We develop metrics to assess the economic impact of these attacks under re-dispatch decisions using optimal power flow methods. These metrics can be use to prioritize the adoption of appropriate countermeasures including PMU placement, encryption, hardware upgrades, and advance attack detection algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of capillary heterogeneity on CO 2 flow and trapping across scales

Capillary heterogeneity has been identified over the last decade as a key control on subsurface CO 2 flow behavior during geological CO 2 sequestration. These heterogeneities can be formed in all sedimentary rocks, ranging from slight variations in the sand grain sizes to extensive sequences of interbedded sands, shales, and limestones. Capillary heterogeneity has been largely, although not entirely, overlooked in subsurface flow modeling because it is assumed to only directly influence fluid redistribution over scales of centimeters to meters. However, even small-scale fluid movements can result in dramatic impacts on the mobility and trapping of the CO 2 over kilometers. Therefore, neglecting capillary heterogeneity at multiple scales could potentially lead to errors in modeling and predicting field-scale plume migration. In this review paper, we aim to provide a consistent overview to (1) establish that capillary heterogeneity can have a major impact on CO 2 plume migration, (2) establish the respective length scales at which capillary heterogeneity matters, and (3) provide guidance for numerical modeling. This review covers pertinent literature and extracts key observations from the core to the field scales. Experimental studies have shown that millimeter-decimeter scale capillary heterogeneity can cause the so-called capillary heterogeneity trapping in addition to pore-scale residual trapping. Even at such a small scale, capillary heterogeneity can already lead to complex upscaled constitutive relationships, such as flow-rate dependent and anisotropic relative permeability, which affects field-scale CO 2 migration even when field-scale heterogeneities are present. Under gravity-dominated flow regimes, centimeter-meter scale capillary heterogeneity can entrap a significant amount of CO 2 at field scale, not just after imbibition but also during drainage. In certain cases, the presence of capillary heterogeneity can even completely stop the vertical movement of the CO 2 plume, hence greatly reducing leakage risks. At meter-kilometer scale, the influence of capillary heterogeneity is more pronounced and can hinder or redirect CO 2 migration in both lateral and vertical directions. The impact of capillary heterogeneity across multiple spatial scales poses a great challenge in modeling CO 2 migration at field scale, because it is practically impossible to build a field-scale earth model with grid blocks at millimeter scale. We recommend a hierarchical modeling approach to address this challenge. At field scale, earth models are built to capture geological features and heterogeneities in high but still practical grid resolutions. For each facies or rock type of the field-scale model, high- resolution meter-scale “conceptual” models are built with millimeter-scale grid blocks to capture representative fine-scale bedding geometries and heterogeneities in various environments of deposition, bridging the gap from subcore scale to the size of a field-scale simulation grid block. Upscaling is then used to preserve the smaller-scale flow dynamics of various rock types in field-scale simulations. Here, future work is needed to (1) refine, improve, and validate the hierarchical modeling approach; (2) build libraries of fine-scale bedding models for facies in various environments of deposition; (3) quantify multiscale capillary heterogeneity effects under subsurface uncertainties; (4) gain learning from different storage formations; and (5) establish best practices that balance accuracy and computational speed.

Capillary heterogeneity↗

Characterizing in-stream turbulent flow for tidal energy converter siting in Cook Inlet, Alaska

Cook Inlet in Alaska is the most promising location for tidal energy development in the U.S. due to its significant tidal range of approximately 10 meters and high volume flux. The inlet's unique geometry and flow characteristics make it the most energetic tidal stream in the nation, with GW-scale potential energy capacity. With the growing interest in tidal energy converter (TEC) deployment in this area, we implemented a regional-scale, 3D hydrodynamic modeling framework to predict tidal current and turbulence characteristics that can assist TEC designers and project managers. We validated the model results extensively using various datasets collected with bottom-mounted acoustic Doppler current profilers and velocimeters. The comparison between the model outputs and observational data highlighted the effectiveness of the 3D FVCOM model and the Mellor-Yamada Level 2.5 Turbulence Model in accurately assessing macro-scale kinetic energy, turbulence intensity, and the production and dissipation rates at a prospective TEC site. Using two months of model simulation data, we examined the channel cross-section for TEC deployment, focusing on undisturbed power density and macro-scale turbulent properties. Further, our findings indicate that understanding the turbulence characteristics and flow properties can enhance Stage I/II resource characterization by identifying optimal locations for TECs and their layouts within the channel. Furthermore, we demonstrated that TEC designers can utilize macro-scale turbulence data from 3D coastal models as boundary conditions for other turbulence models, allowing for a more detailed resolution of the turbulence structure at TEC siting locations. Ultimately, this work emphasizes the importance of estimating flow and turbulence conditions in energetic systems to understand turbulent sites better and improve resource characterization.

16 TIDAL AND WAVE POWER↗

Changes in cardiac output and tibial artery flow during and after progressive LBNP

A 3.0 MHz Pulsed Doppler velocity meter (PD) was used to determine blood velocities in the ascending aorta from the suprasternal notch before, during and after progressive 5 min stages of lower body negative pressure (LBNP) in 7 subjects. Changes in stroke volume were calculated from the systolic velocity integrals. A unique 20 MHz PD was used to estimate bloodflow in the posterior tibial artery. With -20 torr mean stroke volume fell 11% and then continued to decline by 48% before LBNP was terminated. Mean tibial flow fell progressively with LBNP stress, due to an increase in reverse flow component and a reduction in peak forward flow and diameter. Stroke volume increased and heart rate fell dramatically during the first 15 sec of recovery. The LBNP was terminated early in 2 subjects because of vasovagal symptons (V). During V the stroke volume rose 86% which more than compensated for the drop in heart rate. This implies that V is accompanied by a paradoxical increase in venous return and that the reduction in HR is the primary cardiovascular event. During the first 15 sec of recovery these 2 subjects had a distinctive marked rise to heart rate reminiscent of the Bainbridge reflex.

Source record↗

An Ion Doppler Spectrometer Instrument for Ion Temperature and Flow Measurements on SSPX

A high-resolution ion Doppler spectrometer has been installed on the Sustained Spheromak Plasma Experiment to measure ion temperatures and plasma flow. The system is composed of a 1 meter focal length Czerny-Turner spectrometer with diffraction grating line density of 2400 lines/mm, which allows for first order spectra between 300 and 600 nm. A 16-channel photomultiplier tube detection assembly combined with output coupling optics provides a spectral resolution of 0.0126 nm per channel. We calculate in some detail the mapping of curved slit images onto the linear detector array elements. This is important in determining wavelength resolution and setting the optimum vertical extent of the slit. Also, because of the small wavelength window of the IDS, a miniature fiber optic survey spectrometer sensitive to a wavelength range 200 to 1100 nm and having resolution 0.2 nm, is used to obtain a time-integrated spectrum for each shot to verify specific impurity line radiation. Several measurements validate the systems operation. Doppler broadening of C III 464.72 nm line in the plasma shows time-resolved ion temperatures up to 250 eV for hydrogen discharges, which is consistent with neutral particle energy analyzer measurements. Flow measurements show a sub-Alfvenic plasma flow ranging from 5 to 45 km/s for helium discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aerodynamic performance of a 1.35-pressure-ratio axial-flow fan stage

The overall blade element performances and the aerodynamic design parameters are presented for a 1.35-pressure-ratio fan stage. The fan stage was designed for a weight flow of 32.7 kilograms per second and a tip speed of 302.8 meters per second. At design speed the stage peak efficiency of 0.879 occurred at a pressure ratio of 1.329 and design flow. Stage stall margin was approximately 14 percent. At design flow rotor efficiency was 0.94 and the pressure ratio was 1.360.

Osborn, W. M.↗

Velocity Vector Analysis of a Juncture Flow Using a Three-Component Laser Velocimeter

A specialized single-axis, five-beam three-component laser velocimeter was constructed and used to study the flow field in a juncture. The juncture was defined by a blunt leading, edged vertical splitter plate and a sharp leading edged horizontal plate. The investigations were conducted in the Low Turbulence Pressure Tunnel at a Mach number of 0.1 and a Reynolds number of 2.2 x 10(exp 6) per meter over the model. The three-component velocity flow field in the juncture was measured, Reynolds stresses calculated and the velocity vector analysis performed.

Meyers, James F.↗

Experimental study of a radial plasma source

A radially outward acceleration of plasma in cylindrical geometry along an applied electric field and across an axial magnetic field is studied. The configuration, coined a radial plasma source, consists of two ceramic disks positioned parallel to each other, between which a cylindrical molybdenum anode is mounted. The electric field is generated by applying a voltage between the anode and a heated cathode neutralizer that is located away from the ceramic disks. The plasma diagnostic system includes Langmuir probes, an emissive probe, and a balance force meter. The discharge voltage is found to increase when the magnetic field is increased or when the mass flow rate (and the pressure) is decreased. For a discharge current of 1.4 A, the discharge voltage increases from 55 to 120 V when the magnetic field is increased from 0 to 186 G. The azimuthal uniformity of the plasma flow is found to decrease with the increase in gas pressure. The force exerted on the balance force meter is found to be larger than the force exerted by the plasma flow. This disparity indicates that a considerable part of the force is exerted by the neutral gas, which has gained momentum from the plasma via ion-neutral collisions. The force is increased because the momentum delivered for a given deposited power is larger if the energy is deposited in a larger mass, as happens here through plasma collisions. We estimate theoretically the expected force at the collisionless and the collisional limits and find that the measured force is between the expected forces at the two limits.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Velocity vector analysis of a juncture flow using a three component laser velocimeter

A specialized single-axis, five-beam three-component laser velocimeter was constructed and used to study the flow field in a juncture. The juncture was defined by a blunt leading edged vertical splitter plate and a sharp leading edged horizontal plate. The investigations were conducted in the Low Turbulence Pressure Tunnel at a Mach number of 0.1 and a Reynolds number of 2.2 x 10 to the 6th per meter over the model. The three-component velocity flow field in the juncture was measured, Reynolds stresses calculated, and the velocity vector analysis performed.

Meyers, J. F.↗

Completion Report for Well ER-EC-11 Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-EC-11 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, in support of the Nevada Environmental Restoration Project at the Nevada National Security Site (formerly Nevada Test Site), Nye County, Nevada. The well was drilled in September and October 2009 as part of the Pahute Mesa Phase II drilling program. A main objective was to investigate radionuclide migration down-gradient from Well Cluster ER-20-5 and Well ER-20-7 and across the northern Timber Mountain moat structural zone into the area referred to as the Bench, between Pahute Mesa and the Timber Mountain caldera complex. A secondary purpose of the well was to provide detailed hydrogeologic information for the shallow- to intermediate-depth Tertiary volcanic section in the Bench area. This well also provided detailed hydrogeologic information in the Tertiary volcanic section to reduce uncertainties within the Pahute Mesa-Oasis Valley hydrostratigraphic framework model (Bechtel Nevada, 2002). The main 52.1-centimeter hole was drilled to a depth of 507.5 meters and then opened to a diameter of 66.0 centimeters. It was cased with 50.8-centimeter casing to 504.9 meters. The hole diameter was then decreased to 47.0 centimeters, and drilling continued to a total depth of 979.3 meters. It was then cased with 34.0-centimeter casing set at 965.5 meters. The hole diameter was then decreased to 31.1 centimeters and the borehole was drilled to a total depth of 1,264.3 meters. The completion casing string, set to the depth of 1,262.5 meters, consists of 19.4-centimeter stainless-steel casing hanging from 19.4-centimeter carbon-steel casing. The stainless-steel casing has two slotted intervals open to the Tiva Canyon and Topopah Spring aquifers. Four piezometer strings were installed in Well ER-EC-11. A string of carbon-steel 6.0-centimeter tubing with one slotted interval was inserted outside the 50.8-centimeter casing, within the 66.0-centimeter borehole for access to the Timber Mountain aquifer, and landed at 475.3 meters. A second string of 6.0-centimeter tubing with one slotted interval was inserted outside the 34.0-centimeter casing, within the 47.0-centimeter borehole for access to the Benham aquifer, and landed at 911.7 meters. A third piezometer string consists of 7.3-centimeter stainless-steel tubing that hangs from 6.0-centimeter carbon-steel tubing via a crossover sub. This string was landed at 1,029.5 meters to monitor the Tiva Canyon aquifer. The deepest string of 7.3-centimeter tubing was landed at 1,247.8 meters to monitor the Topopah Spring aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 meters, 67 percussion gun and rotary sidewall core samples, various geophysical logs, fluid samples (for groundwater chemistry analysis and tritium measurements), and water-level measurements. The well penetrated 1,264.3 meters of Tertiary volcanic rock, including three saturated welded-tuff aquifers and one saturated lava-flow aquifer. A water level was measured in the Timber Mountain aquifer at 449.6 meters, during open-hole geophysical logging on September 20, 2009. The fluid level measured after the total depth was reached and the upper aquifer was cased off was 450.0 meters when measured in the open borehole on October 17, 2009. Measurements on samples taken from the undeveloped well indicated that tritium levels averaging approximately 12,430 picocuries per liter (less than Safe Drinking Water Act levels) were encountered within the Benham aquifer. Tritium was below the minimum detectable activity concentration for samples collected from the Tiva Canyon aquifer and the Topopah Spring aquifer.

54 ENVIRONMENTAL SCIENCES↗

Life tests of small turbine-type flowmeters in liquid hydrogen

A total of 14 turbine-type flowmeters of 2.5- and 4-cm nominal size were operated for 100 or more hours at an average fluid speed in the unobstructed, upstream pipe of 20 m/s for the smaller meters and 9 m/s for the larger meters. Calibration shifts over a 6.1 range of calibration flow rates varied from 0.5 percent to 1 percent after 50 hr of operation. It is concluded that use of ball bearings with glass-filled Teflon retainers is most likely to produce minimal calibration shift with protracted use. Bearing replacement after 50 to 100 hr is recommended, depending on accuracy requirements, for meters used at the fluid speeds of the tests.

Hobart, H. F.↗

Coupling a three-dimensional subsurface flow and transport model with a land surface model to simulate stream–aquifer–land interactions (CP v1.0)

A fully coupled three-dimensional surface and subsurface land model is developed and applied to a site along the Columbia River to simulate three-way interactions among river water, groundwater, and land surface processes. The model features the coupling of the Community Land Model version 4.5 (CLM4.5) and a massively parallel multiphysics reactive transport model (PFLOTRAN). The coupled model, named CP v1.0, is applied to a 400 m × 400 m study domain instrumented with groundwater monitoring wells along the Columbia River shoreline. CP v1.0 simulations are performed at three spatial resolutions (i.e., 2, 10, and 20 m) over a 5-year period to evaluate the impact of hydroclimatic conditions and spatial resolution on simulated variables. Results show that the coupled model is capable of simulating groundwater–river-water interactions driven by river stage variability along managed river reaches, which are of global significance as a result of over 30 000 dams constructed worldwide during the past half-century. Our numerical experiments suggest that the land-surface energy partitioning is strongly modulated by groundwater–river-water interactions through expanding the periodically inundated fraction of the riparian zone, and enhancing moisture availability in the vadose zone via capillary rise in response to the river stage change. Meanwhile, CLM4.5 fails to capture the key hydrologic process (i.e., groundwater–river-water exchange) at the site, and consequently simulates drastically different water and energy budgets. Furthermore, spatial resolution is found to significantly impact the accuracy of estimated the mass exchange rates at the boundaries of the aquifer, and it becomes critical when surface and subsurface become more tightly coupled with groundwater table within 6 to 7 meters below the surface. Inclusion of lateral subsurface flow influenced both the surface energy budget and subsurface transport processes as a result of river-water intrusion into the subsurface in response to an elevated river stage that increased soil moisture for evapotranspiration and suppressed available energy for sensible heat in the warm season. The coupled model developed in this study can be used for improving mechanistic understanding of ecosystem functioning and biogeochemical cycling along river corridors under historical and future hydroclimatic changes. The dataset presented in this study can also serve as a good benchmarking case for testing other integrated models.

58 GEOSCIENCES↗

Coupling a three-dimensional subsurface flow and transport model with a land surface model to simulate stream–aquifer–land interactions (CP v1.0)

Abstract. A fully coupled three-dimensional surface and subsurface land model is developed and applied to a site along the Columbia River to simulate three-way interactions among river water, groundwater, and land surface processes. The model features the coupling of the Community Land Model version 4.5 (CLM4.5) and a massively parallel multiphysics reactive transport model (PFLOTRAN). The coupled model, named CP v1.0, is applied to a 400 m × 400 m study domain instrumented with groundwater monitoring wells along the Columbia River shoreline. CP v1.0 simulations are performed at three spatial resolutions (i.e., 2, 10, and 20 m) over a 5-year period to evaluate the impact of hydroclimatic conditions and spatial resolution on simulated variables. Results show that the coupled model is capable of simulating groundwater–river-water interactions driven by river stage variability along managed river reaches, which are of global significance as a result of over 30 000 dams constructed worldwide during the past half-century. Our numerical experiments suggest that the land-surface energy partitioning is strongly modulated by groundwater–river-water interactions through expanding the periodically inundated fraction of the riparian zone, and enhancing moisture availability in the vadose zone via capillary rise in response to the river stage change. Meanwhile, CLM4.5 fails to capture the key hydrologic process (i.e., groundwater–river-water exchange) at the site, and consequently simulates drastically different water and energy budgets. Furthermore, spatial resolution is found to significantly impact the accuracy of estimated the mass exchange rates at the boundaries of the aquifer, and it becomes critical when surface and subsurface become more tightly coupled with groundwater table within 6 to 7 meters below the surface. Inclusion of lateral subsurface flow influenced both the surface energy budget and subsurface transport processes as a result of river-water intrusion into the subsurface in response to an elevated river stage that increased soil moisture for evapotranspiration and suppressed available energy for sensible heat in the warm season. The coupled model developed in this study can be used for improving mechanistic understanding of ecosystem functioning and biogeochemical cycling along river corridors under historical and future hydroclimatic changes. The dataset presented in this study can also serve as a good benchmarking case for testing other integrated models.

58 GEOSCIENCES↗

Occurrence of perched saturation and interflow over an argillic horizon in a low relief hillslope.

Abstract. Many of the soils in the south-eastern US are characterized by an argillic, or clay horizon, that largely parallels the soil surface at depths ranging from a few centimeters to 100 cen-timeters. The degree to which these argillic horizons alter subsurface movement of infiltrated water is not well known. Interflow, or throughflow, is shallow lateral subsurface flow that moves over a horizon that restricts percolation. This research investigates how often and under what conditions a relatively deep (20-150+cm) argillic horizon on low slope (2-6%) hillsides causes interflow to oc-cur. Research is being conducted at the Savannah River Site, Aiken, South Carolina, on a small zero-order watershed. In the first phase of this research, a high resolution topographic map of the clay layer was developed. This map will be used to instrument designated “low” spots with max rise piezo-meters in order to determine if there is channelized subsurface flow. In situ conductivities of the clay layer and the surface horizons were measured using an Amoozegar meter, and bulk density samples were taken and measured. Along with soil topographic measurements, data-logging piezometers have been installed to measure the piezometric head above, in, and below the argillic horizon to further investigate interflow as a potential hydraulic routing mechanism. The stream that drains the catchment was instrumented with a 2’ H flume and data-logging pressure transducer to measure stream flow. Climate data including precipitation, barometric pressure and temperature, are being continuously collected in an open area approximately ¼ mile from the study site. Combining the shallow surface and subsurface piezometric heads with stream flow rates, we should be able to determine if and when the clay layer is contributing to inter-flow.

60 APPLIED LIFE SCIENCES↗

Models of the diffuse radar backscatter from Mars

The topographies of several debris flow units near the Mount St. Helens Volcano were measured at lateral scales of millimeters to meters in September 1990. The objective was to measure the surface roughness of the debris flows at scales smaller than, on the order of, and larger that the radar wavelength of common remote sensing radars. A laser profiling system and surveying instruments were used to obtain elevation data for square areas that varied in size from 10 to 32 cm. The elevation data were converted to estimates of the power spectrum of surface roughness. The conversions were based upon standard periodogram techniques, and upon a modified spectral estimation technique that was developed.

England, A. W.↗

Static and Wind Tunnel Aero-Performance Tests of NASA AST Separate Flow Nozzle Noise Reduction Configurations

This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.

Mikkelsen, Kevin L.↗

NaK Plugging Meter Design for the Feasibility Test Loops

The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

Pearson, J. Boise↗