Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

SU-E-T-557: Measuring Neutron Activation of Cardiac Devices Irradiated During Proton Therapy Using Indium Foils

Purpose: Measuring Neutron Activation of Cardiac devices Irradiated during Proton Therapy using Indium Foils Methods: The foils had dimensions of 25mm x 25mm x 1mm. After being activated, the foils were placed in a Canberra Industries well chamber utilizing a NaI(Tl) scintillation detector. The resulting gamma spectrum was acquired and analyzed using Genie 2000 spectroscopy software. One activation foil was placed over the upper, left chest of RANDO where a pacemaker would be. The rest of the foils were placed over the midline of the patient at different distances, providing a spatial distribution over the phantom. Using lasers and BBs to align the patient, 200 MU square fields were delivered to various treatment sites: the brain, the pancreas, and the prostate. Each field was shot at least a day apart, giving more than enough time for activity of the foil to decay (t1=2 = 54.12 min). Results: The net counts (minus background) of the three aforementioned peaks were used for our measurements. These counts were adjusted to account for detector efficiency, relative photon yields from decay, and the natural abundance of 115-In. The average neutron flux for the closed multi-leaf collimator irradiation was measured to be 1.62 x 106 - 0.18 x 106 cm2 s-1. An order of magnitude estimate of the flux for neutrons up to 1 keV from Diffenderfer et al. gives 3 x 106 cm2 s-1 which does agree on the order of magnitude. Conclusion: Lower energy neutrons have higher interaction cross-sections and are more likely to damage pacemakers. The thermal/slow neutron component may be enough to estimate the overall risk. The true test of the applicability of activation foils is whether or not measurements are capable of predicting cardiac device malfunction. For that, additional studies are needed to provide clinical evidence one way or the other.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-200: An Improved Method for Event Selection in Compton Camera Imaging for Particle Therapy

Purpose: The uncertainty in the beam range in particle therapy limits the conformality of the dose distributions. Compton scatter cameras (CC), which measure the prompt gamma rays produced by nuclear interactions in the patient tissue, can reduce this uncertainty by producing 3D images confirming the particle beam range and dose delivery. However, the high intensity and short time windows of the particle beams limit the number of gammas detected. We attempt to address this problem by developing a method for filtering gamma ray scattering events from the background by applying the known gamma ray spectrum. Methods: We used a 4 stage Compton camera to record in list mode the energy deposition and scatter positions of gammas from a Co-60 source. Each CC stage contained a 4×4 array of CdZnTe crystal. To produce images, we used a back-projection algorithm and four filtering Methods: basic, energy windowing, delta energy (ΔE), or delta scattering angle (Δθ). Basic filtering requires events to be physically consistent. Energy windowing requires event energy to fall within a defined range. ΔE filtering selects events with the minimum difference between the measured and a known gamma energy (1.17 and 1.33 MeV for Co-60). Δθ filtering selects events with the minimum difference between the measured scattering angle and the angle corresponding to a known gamma energy. Results: Energy window filtering reduced the FWHM from 197.8 mm for basic filtering to 78.3 mm. ΔE and Δθ filtering achieved the best results, FWHMs of 64.3 and 55.6 mm, respectively. In general, Δθ filtering selected events with scattering angles < 40°, while ΔE filtering selected events with angles > 60°. Conclusion: Filtering CC events improved the quality and resolution of the corresponding images. ΔE and Δθ filtering produced similar results but each favored different events.

60 APPLIED LIFE SCIENCES↗

Investigation of {sup 166}Er in the respective (n, n′γ) reaction

The spectrum, angular distribution, and linear polarization of gamma rays from the (n, n′γ) reaction on {sup 166}Er were measured in a beam of reactor fast neutrons. The known scheme of levels and gamma transitions for this nucleus was supplemented. Previously unknown gamma transitions and levels were found along with their features. The completeness of the scheme of levels whose quantum numbers J{sup π} range from 0{sup +} to 4{sup +} and whose excitation energy extends up to 1.9 MeV was established. The absence of rotational levels for the nonrotational states at 1703.11 keV (2{sup +}), 1713.42 keV (0{sup +}), and 1760.51 keV (4{sup +}) was confirmed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigations of Properties of {sup 89}Y Levels with Reactor Fast Neutrons

By employing a beam of reactor fast neutrons, the spectrum of gamma rays up to an energy of 4.6MeV and their angular distributions with respect to the neutron-beamaxis aremeasured in the reaction {sup 89}Y(n, n'γ). The multipolarities and multipole-mixture parameters for 34 gamma transitions and the spin–parities J{sup π} of states excited in this reaction are determined. The lifetimes of the lowest 32 levels of 89Y were measured by the Doppler shift attenuation method, and the reduced probabilities for the respective gamma transitions were calculated. Levels of the K{sup π} = +5/2{sup +} and K{sup π} = −7/2{sup +} bands associated with, respectively, prolate and oblate deformation shapes are found in {sup 89}Y at low excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward a complete theory for predicting inclusive deuteron breakup away from stability

We present an account of the current status of the theoretical treatment of inclusive (d, p) reactions in the breakup-fusion formalism, pointing to some applications and making the connection with current experimental capabilities. Three independent implementations of the reaction formalism have been recently developed, making use of different numerical strategies. The codes also originally relied on two different but equivalent representations, namely the prior (Udagawa-Tamura, UT) and the post (Ichimura-Austern-Vincent, IAV) representations. The different implementations have been benchmarked for the first time, and then applied to the Ca isotopic chain. The neutron-Ca propagator is described in the Dispersive Optical Model (DOM) framework, and the interplay between elastic breakup (EB) and non-elastic breakup (NEB) is studied for three Ca isotopes at two different bombarding energies. The accuracy of the description of different reaction observables is assessed by comparing with experimental data of (d, p) on 40,48Ca. We discuss the predictions of the model for the extreme case of an isotope (60Ca) currently unavailable experimentally, though possibly available in future facilities (nominally within production reach at FRIB). We explore the use of (d, p) reactions as surrogates for (n,γ) processes, by using the formalism to describe the compound nucleus formation in a (d,pγ) reaction as a function of excitation energy, spin, and parity. The subsequent decay is then computed within a Hauser-Feshbach formalism. Comparisons between the (d,pγ) and (n,γ) induced gamma decay spectra are discussed to inform efforts to infer neutron captures from (d,pγ) reactions. Finally, we identify areas of opportunity for future developments, and discuss a possible path toward a predictive reaction theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RASE OSS

The Replicative Assessment of Spectroscopic Equipment (RASE) methodology is a semi-empirical approach to generating synthetic gamma-ray spectra for injection into a radionuclide identification algorithm of a vendor-provided detection system. RASE facilitates studies of the spectroscopic device performance and a quantitative assessment of its capabilities to correctly distinguish and identify isotopes of interest in realistic scenarios.

Sangiorgio, Samuele↗

Berkeley Anomaly Detection (BAD) v1.0

The software is for detecting and identifying anomalies within gamma-ray spectra. The design enables quick implementation, testing, comparison, and deployment of different anomaly and identification algorithms. The software currently contains implementations of four algorithms, two of which are common place within the field, and two that novel research products from this effort.

Curtis, Joseph↗

Benchmark Algorithm for RadioNuclide Identification v1.0

Benchmark Algorithm for Radio-Nuclide Identification (BARNI) is an automatic radionuclide identification tool for use with gamma-ray spectra. BARNI is designed to serve as a comparative tool for commercial vendor algorithms, such as those found in RadioIsotope Identification Devices (RIID). The tool incorporates an automated training routine allowing BARNI's classifier to be trained for a variety of detectors. The identification algorithm uses a peak search, the results of which are used to build features that are subsequently used for training a classifier. The user provided spectral templates allow BARNI to be trained for any detector of the user's choice. Is

NELSON, KARLE.↗

Python Urban Deployment Model (PyUDM) v1.0.0

The Python Urban Deployment Model (PyUDM) is a simulation tool used to investigate networks of static radiation detectors in urban environments. PyUDM simulates traffic, stationary NaI gamma-ray detectors, and moving radioactive sources on simulated vehicles. The analyzed output of the simulations contain valuable insights into the performance of different configurations of urban radiological detector configurations such as their ability to detect sources moving through the environment. To accurately simulate radioactive material moving through urban environments, PyUDM combines Monte Carlo simulation tools, publicly available map and traffic data, and measured gamma-ray spectra from urban environments.

Rofors, Emil↗

Short-Duration Simulations from Measurements.

A method is presented that ascribes proper statistical variability to simulations that are derived from longer-duration measurements. This method is applicable to simulations of either real-value or integer-value data. An example is presented that demonstrates the applicability of this technique to the synthesis of gamma-ray spectra.

Mitchell, Dean J.↗

Hard X-ray mirrors for Nuclear Security

Research performed under this LDRD aimed to demonstrate the ability to detect and measure hard X-ray emissions using multilayer X-ray reflective optics above 400 keV, to enable the development of inexpensive and high-accuracy mirror substrates, and to investigate applications of hard X-ray mirrors of interest to the nuclear security community. Experiments conducted at the European Synchrotron Radiation Facility demonstrated hard X-ray mirror reflectivity up to 650 keV for the first time. Hard X-ray optics substrates must have surface roughness under 3 to 4 Angstrom rms, and three materials were evaluated as potential substrates: polycarbonates, thin Schott glass and a new type of flexible glass called Willow Glass®. Chemical smoothing and thermal heating of the surface of polycarbonate samples, which are inexpensive but have poor intrinsic surface characteristics, did not yield acceptable surface roughness. D263 Schott glass was used for the focusing optics of the NASA NuSTAR telescope. The required specialized hardware and process were costly and motivated experiments with a modified non-contact slumping technique. The surface roughness of the glass was preserved and the process yielded cylindrical shells with good net shape pointing to the potential advantage of this technique. Finally, measured surface roughness of 200 and 130 μm thick Willow Glass sheets was between 2 and 2.5 A rms. Additional results of flexibility tests and multilayer deposition campaigns indicated it is a promising substrate for hard X-ray optics. The detection of U and Pu characteristics X-ray lines and gamma emission lines in a high background environment was identified as an area for which X-ray mirrors could have an impact and where focusing optics could help reduce signal to noise ratio by focusing signal onto a smaller detector. Hence the first one twelvetant of a Wolter I focusing optics for the 90 to 140 keV energy range based on aperiodic multilayer coating was designed. Finally, we conducted the first demonstration that reflective multilayer mirrors could be used as diagnostic for HED experiment with an order of magnitude improvement in signal-to-noise ratio for the multilayer optic compared a transmission crystal spectrometer.

36 MATERIALS SCIENCE↗

Passive Gamma Analysis of the Boiling-Water-Reactor Assemblies

Passive gamma analysis can be used to determine BU and CT of BWR assembly. The analysis is somewhat more complicated and less effective than similar method for PWR assemblies. From the measurements along the lengths of the BWR1 and BWR9 assemblies, there are hints that we may be able to use their information to help improve the model functions for better results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing the Performance of Radionuclide Identification Software in the Hunt for Nuclear Security Threats

The Radionuclide Analysis Kit (RNAK), my team’s most recent nuclide identification software, is entering the testing phase. A question arises: will removing rare nuclides from the software’s library improve its overall performance? An affirmative response indicates fundamental errors in the software’s framework, while a negative response confirms the effectiveness of the software’s key machine learning algorithms. After thorough testing, I found that the performance of RNAK cannot be improved with the library choice effect, thus verifying the effectiveness of RNAK’s algorithms—multiple linear regression, Bayesian network using the Viterbi algorithm, and branch and bound search.

97 MATHEMATICS AND COMPUTING↗

Nondestructive Analysis of MET-5 Paint Can at TA35 Building 2 A-Wing Vault

In Building 2 A-wing vault MET-5 has some drums and other packages they wanted NEN-1 help identifying nondestructively. Measurements using a mechanically cooled portable high-purity germanium HPGe Ortec detective were taken of a paint can container labeled DU-2A to determine if any radioactive material was inside. The HPGe detector measures the gamma rays emitted by radioactive material and displays it as a spectrum. The spectrum is used to identify this radioactive material by using appropriate analysis software and identifying the gamma ray peaks. A paint can container, DU-2A, was analyzed with PeakEasy 4.84 and FRAM 5.2. The FRAM report is shown. The enrichment is 0.091% U235 and 99.907% U238. This material is depleted uranium. The measurement was performed in the near field, and to extract a mass a far field measurement will need to be taken.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation Detection Overview for Nuclear Emergency Response

This presentation discusses the fundamentals of gamma and neutron detection; presents an overview of the DOE Triage and JTOT Programs, gamma, and neutron signatures in select measurements; and offers a detector demonstration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading FLIR NanoRaider with the next Generation of CdZnTe Detectors. Goal - Integrate VFG detectors into FLIR R200. Advanced Virtual Grid ASIC (AVG-ASIC).

This document presents motivations, goals and the current status of this project; development (fabrication, performance) of position-sensitive virtual Frisch-grid detectors proposed for nanoRaider, an instrument commonly used by nuclear inspectors; ASIC developments for CZT detectors; and the electronics development for the detector prototype..

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress, Performance, and Prospects of Ultra-High Resolution Microcalorimeter Spectrometers

In 2005 the LANL/NIST team used a single high-resolution microcalorimeter detector to measure the gamma-ray spectrum of a plutonium sample. After more than a decade of research and development on this topic, both the technology and our general understanding of its capabilities have advanced greatly, such that a progress review is now timely. We examine the scenario of a large-scale reprocessing plant and conclude that current non-destructive analysis (NDA) methods are inadequate to safeguard such a facility to the desired levels, leading to undesirable dependence on massspectrometry (MS) destructive analysis (DA). The development of microcalorimeter detectors is intended to close the performance gap between NDA and DA methods to address the needs of nuclear facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗