Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Highly sensitive up-conversion optical thermometry based on Yb3+-Er3+ co-doped NaLa(MoO4)2 green phosphors

Highlights: • Phosphors NaLa(MoO{sub 4}){sub 2}:Er{sup 3+}/Yb{sup 3+} UC with intense green emission were synthesized. • The thermometric property based on FIR {sup 2}H{sub 11/2}/{sup 4}S{sub 3/2} → {sup 4}I{sub 15/2} was evaluated. - Abstract: Pursuing highly sensitive thermometry is a permanent goal in recent scientific research, which can be achieved through Fluorescence intensity ratio (FIR) technique due to its fast response, excellent accuracy, high spatial resolution and tunable size. Herein, highly sensitive micro-thermometers based on FIR of the thermal coupled levels (TCLs) {sup 2}H{sub 11/2}/{sup 4}S{sub 3/2} → {sup 4}I{sub 15/2} from Er{sup 3+} in phosphors NaLa(MoO{sub 4}){sub 2}: Yb{sup 3+}/Er{sup 3+} up-conversion (UC) were developed, which emits dazzling green light with the excitation of 980 nm laser and its UC spectra consisted of intense green bands peaked at 530 and 552 nm and a negligible 658 nm red emission ({sup 4}F{sub 9/2} → {sup 4}I{sub 15/2}), respectively. The maximum absolute sensitivity approached to 0.023 K{sup -1} at 490 K through assessing FIR based on thermo-responsive green emissions. Results suggest the present green-emitting phosphors have great potential to serve as UC thermometers with high and stable sensitivity, which greatly meet the growing demand for sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous measurements of kinetic and scalar energy spectrum time evolution in the Richtmyer–Meshkov instability upon reshock

The Richtmyer–Meshkov instability (Richtmyer, Commun. Pure Appl. Maths , vol. 13, issue 2, 1960, pp. 297–319; Meshkov, Fluid Dyn. , vol. 4, issue 5, 1972, pp. 101–104) of a twice-shocked gas interface is studied using both high spatial resolution single-shot (SS) and lower spatial resolution, time-resolved, high-speed (HS) simultaneous planar laser-induced fluorescence and particle image velocimetry in the Wisconsin Shock Tube Laboratory's vertical shock tube. The initial condition (IC) is a shear layer with broadband diffuse perturbations at the interface between a helium–acetone mixture and argon. This IC is accelerated by a shock of nominal strength Mach number $M = 1.75$ , and then accelerated again by the transmitted shock that reflects off the end wall of the tube. An ensemble of experiments is analysed after reshock while the interface mixing width grows linearly with time. The kinetic and scalar energy spectra and the terms of their evolution equation are calculated and compared between SS and HS experiments. The inertial range scaling of the scalar power spectrum is found to follow Gibson's relation (Gibson, Phys. Fluids , vol. 11, issue 11, 1968, pp. 2316–2327) as a function of Schmidt number when the effective turbulent Schmidt number is used in place of the material Schmidt number that controls equilibrium scaling. Further, the spatially integrated scalar flux follows similar behaviour observed for the kinetic energy in large eddy simulation studies by Zeng et al. ( Phys. Fluids , vol. 30, issue 6, 2018, 064106) while the spatially varying scalar flux exhibits back scatter along the centre of the mixing layer and forward energy transfer in the spike and bubble regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Second Flight of the Sunrise Balloon-borne Solar Observatory: Overview of Instrument Updates, the Flight, the Data, and First Results

The Sunrise balloon-borne solar observatory, consisting of a 1 m aperture telescope that provides a stabilized image to a UV filter imager and an imaging vector polarimeter, carried out its second science flight in 2013 June. It provided observations of parts of active regions at high spatial resolution, including the first high-resolution images in the Mg ii k line. The obtained data are of very high quality, with the best UV images reaching the diffraction limit of the telescope at 3000 Å after Multi-Frame Blind Deconvolution reconstruction accounting for phase-diversity information. Here a brief update is given of the instruments and the data reduction techniques, which includes an inversion of the polarimetric data. Mainly those aspects that evolved compared with the first flight are described. A tabular overview of the observations is given. In addition, an example time series of a part of the emerging active region NOAA AR 11768 observed relatively close to disk center is described and discussed in some detail. The observations cover the pores in the trailing polarity of the active region, as well as the polarity inversion line where flux emergence was ongoing and a small flare-like brightening occurred in the course of the time series. The pores are found to contain magnetic field strengths ranging up to 2500 G, and while large pores are clearly darker and cooler than the quiet Sun in all layers of the photosphere, the temperature and brightness of small pores approach or even exceed those of the quiet Sun in the upper photosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Ga grading of sequentially produced Cu(In,Ga)Se{sub 2} solar cells studied by high resolution X-ray fluorescence

There is particular interest to investigate compositional inhomogeneity of Cu(In,Ga)Se{sub 2} solar cell absorbers. We introduce an approach in which focused ion beam prepared thin lamellas of complete solar cell devices are scanned with a highly focused synchrotron X-ray beam. Analyzing the resulting fluorescence radiation ensures high resolution compositional analysis combined with high spatial resolution. Thus, we are able to detect subtle variations of the Ga/(Ga + In) ratio down to 0.01 on a submicrometer scale. We observed that for sequentially processed solar cells a higher selenization temperature leads to absorbers with almost homogenous Ga/(Ga + In) ratio, which significantly improved the conversion efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stark effect at the Si I series limit

Small redshifts and weakenings of high n lines in members of the Si series observed over a sunspot are interpreted as due to the Stark effect. Other origins, including Doppler motions, appear to be excluded. The spectra were obtained with high spatial resolution using the NRL high-resolution telescope and spectrograph. The origin of the Stark effect is not yet certain. An interpretation in terms of a quasi-static quadratic effect would require rather high perturber densities. An alternative interpretation would be a motional Stark effect, arising perhaps through the presence of magnetohydrodynamic waves.

Jordan, C.↗

All Source Solution Decision Support Products Created for Stennis Space Center in Response to Hurricane Katrina

In the aftermath of Hurricane Katrina and in response to the needs of SSC (Stennis Space Center), NASA required the generation of decision support products with a broad range of geospatial inputs. Applying a systems engineering approach, the NASA ARTPO (Applied Research and Technology Project Office) at SSC evaluated the Center's requirements and source data quality. ARTPO identified data and information products that had the potential to meet decision-making requirements; included were remotely sensed data ranging from high-spatial-resolution aerial images through high-temporal-resolution MODIS (Moderate Resolution Imaging Spectroradiometer) products. Geospatial products, such as FEMA's (Federal Emergency Management Agency's) Advisory Base Flood Elevations, were also relevant. Where possible, ARTPO applied SSC calibration/validation expertise to both clarify the quality of various data source options and to validate that the inputs that were finally chosen met SSC requirements. ARTPO integrated various information sources into multiple decision support products, including two maps: Hurricane Katrina Inundation Effects at Stennis Space Center (highlighting surge risk posture) and Vegetation Change In and Around Stennis Space Center: Katrina and Beyond (highlighting fire risk posture).

Ross, Kenton W.↗

Dynamic Transmission Electron Microscopy

Dynamic transmission electron microscopy (DTEM) combines the benefits of high spatial resolution electron microscopy with the high temporal resolution of ultrafast lasers. The incorporation of these two components into a single instrument provides a perfect platform for in situ observations of material processes. However, previous DTEM applications have focused on observing structural changes occurring in samples exposed to high vacuum. Therefore, in order to expand the pump-probe experimental regime to more natural environmental conditions, in situ gas and liquid chambers must be coupled with Dynamic TEM. This chapter describes the current and future applications of in situ liquid DTEM to permit time-resolved atomic scale observations in an aqueous environment, Although this chapter focuses mostly on in situ liquid imaging, the same research potential exists for in situ gas experiments and the successful integration of these techniques promises new insights for understanding nanoparticle, catalyst and biological protein dynamics with unprecedented spatiotemporal resolution.

Dynamic TEM↗

Requirements for a Moderate-Resolution Infrared Imaging Sounder (MIRIS)

The high cost of imaging and sounding from space warrants exploration of new methods for obtaining the required information, including changing the spectral band sets, employing new technologies and merging instruments. In some cases we must consider relaxation of the current capability. In others, we expect higher performance. In general our goal is to meet the VIIRS and CrIS requirements while providing the enhanced next generation capabilities: 1) Hyperspectral Imaging in the Vis/NIR bands, 2) High Spatial Resolution Sounding in the Infrared bands. The former will improve the accuracy of ocean color products, aerosols and water vapor, surface vegetation and geology. The latter will enable the high-impact achieved by the current suite of hyperspectral infrared sounders to be achieved by the next generation high resolution forecast models. We examine the spectral, spatial and radiometric requirements for a next generation system and technologies that can be applied from the available inventory within government and industry. A two-band grating spectrometer instrument called the Moderate-resolution Infrared Imaging Sounder (MIRIS) is conceived that, when used with the planned NASA PACE Ocean Color Instrument (OCI) will meet the vast majority of CrIS and VIIRS requirements in the all bands and provide the next generation capabilities desired. MIRIS resource requirements are modest and the Technology Readiness Level is high leading to the expectation that the cost and risk of MIRIS will be reasonable.

Atmospheric Infrared Sounder (AIRS)↗

Application of THz probe radiation in low-coherent tomographs based on spatially separated counterpropagating beams

A principle of designing a high-resolution low-coherent THz tomograph, which makes it possible to investigate media with a high spatial resolution (in the range λ{sub 0} – 2λ{sub 0}, where λ{sub 0} is the average probe wavelength) is considered. The operation principle of this tomograph implies probing a medium by radiation with a coherence length of 8λ{sub 0} and recording a hologram of a focused image of a fixed layer of this medium using spatially separated counterpropagating object and reference beams. Tomograms of the medium studied are calculated using a temporal approach based on application of the time correlation function of probe radiation. (terahertz radiation)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Future of Electron Scattering and Diffraction

The ability to correlate the atomic- and nanoscale-structure of condensed matter with physical properties (e.g., mechanical, electrical, catalytic, and optical) and functionality forms the core of many disciplines. Directing and controlling materials at the quantum-, atomic-, and molecular-levels creates enormous challenges and opportunities across a wide spectrum of critical technologies, including those involving the generation and use of energy. The workshop identified next generation electron scattering and diffraction instruments that are uniquely positioned to address these grand challenges. The workshop participants identified four key areas where the next generation of such instrumentation would have major impact: A – Multidimensional Visualization of Real Materials B – Atomic-scale Molecular Processes C – Photonic Control of Emergence in Quantum Materials D – Evolving Interfaces, Nucleation, and Mass Transport Real materials are comprised of complex three-dimensional arrangements of atoms and defects that directly determine their potential for energy applications. Understanding real materials requires new capabilities for three-dimensional atomic scale tomography and spectroscopy of atomic and electronic structures with unprecedented sensitivity, and with simultaneous spatial and energy resolution. Many molecules are able to selectively and efficiently convert sunlight into other forms of energy, like heat and electric current, or store it in altered chemical bonds. Understanding and controlling such process at the atomic scale require unprecedented time resolution. One of the grand challenges in condensed matter physics is to understand, and ultimately control, emergent phenomena in novel quantum materials that necessitate developing a new generation of instruments that probe the interplay among spin, charge, orbital, and lattice degrees of freedom with intrinsic time- and length-scale resolutions. Molecules and soft matter require imaging and spectroscopy with high spatial resolution without damaging their structure. The strong interaction of electrons with matter allows high-energy electron pulses to gather structural information before a sample is damaged. Electron ScatteringImaging, diffraction, and spectroscopy are the fundamental capabilities of electron-scattering instruments. The DOE BES-funded TEAM (Transmission Electron Aberration-corrected Microscope) project achieved unprecedented sub-atomic spatial resolution in imaging through aberration-corrected transmission electron microscopy. To further advance electron scattering techniques that directly enable groundbreaking science, instrumentation must advance beyond traditional two-dimensional imaging. Advances in temporal resolution, recording the full phase and energy spaces, and improved spatial resolution constitute a new frontier in electron microscopy, and will directly address the BES Grand Challenges, such as to “control the emergent properties that arise from the complex correlations of atomic and electronic constituents” and the “hidden states” “very far away from equilibrium”. Ultrafast methods, such as the pump-probe approach, enable pathways toward understanding, and ultimately controlling, the chemical dynamics of molecular systems and the evolution of complexity in mesoscale and nanoscale systems. Central to understanding how to synthesize and exploit functional materials is having the ability to apply external stimuli (such as heat, light, a reactive flux, and an electrical bias) and to observe the resulting dynamic process in situ and in operando, and under the appropriate environment (e.g., not limited to UHV conditions). To enable revolutionary advances in electron scattering and science, the participants of the workshop recommended three major new instrumental developments: A. Atomic-Resolution Multi-Dimensional Transmission Electron Microscope: This instrument would provide quantitative information over the entire real space, momentum space, and energy space for visualizing dopants, interstitials, and light elements; for imaging localized vibrational modes and the motion of charged particles and vacancies; for correlating lattice, spin, orbital, and charge; and for determining the structure and molecular chemistry of organic and soft matter. The instrument will be uniquely suited to answer fundamental questions in condensed matter physics that require understanding the physical and electronic structure at the atomic scale. Key developments include stable cryogenic capabilities that will allow access to emergent electronic phases, as well as hard/soft interfaces and radiation- sensitive materials. B. Ultrafast Electron Diffraction and Microscopy Instrument: This instrument would be capable of nano-diffraction with 10 fs temporal resolution in stroboscopic mode, and better than 100 fs temporal resolution in single shot mode. The instrument would also achieve single- shot real-space imaging with a spatial/temporal resolution of 10 nm/10 ps, representing a thousand fold improvement over current microscopes. Such a capability would be complementary to x-ray free electron lasers due to the difference in the nature of electron and x-ray scattering, enabling space-time mapping of lattice vibrations and energy transport, facilitating the understanding of molecular dynamics of chemical reactions, the photonic control of emergence in quantum materials, and the dynamics of mesoscopic materials. C. Lab-In-Gap Dynamic Microscope: This instrument would enable quantitative measurements of materials structure, composition, and bonding evolution in technologically relevant environments, including liquids, gases and plasmas, thereby assuring the understanding of structure function relationship at the atomic scale with up to nanosecond temporal resolution. This instrument would employ a versatile, modular sample stage and holder geometry to allow the multi-modal (e.g., optical, thermal, mechanical, electrical, and electrochemical) probing of materials’ functionality in situ and in operando. The electron optics encompasses a pole piece that can accommodate the new stage, differential pumping, detectors, aberration correctors, and other electron optical elements for measurement of materials dynamics. To realize the proposed instruments in a timely fashion, BES should aggressively support research and development of complementary and enabling instruments, including new electron sources, advanced electron optics, new tunable specimen pumps and sample stages, and new detectors. The proposed instruments would have transformative impact on physics, chemistry, materials science, engineering

43 PARTICLE ACCELERATORS↗

Scaling the SIESTA Magnetohydrodynamics Equilibrium Code

We report the results of a scaling effort that increases both the speed and resolution of the SIESTA magnetohydrodynamic equilibrium code. SIESTA is capable of computing three-dimensional plasma equilibria with magnetic islands at high spatial resolutions for toroidally confined plasmas. Starting with a small-scale parallel im- plementation, we identified scale-dependent bottlenecks of the code and developed scalable alternatives for each performance-significant functionality, cumulatively increasing the runtime speed and scalability with the number of processors. The net outcome is an improvement in speed by over ten-fold, utilizing a few thousand processors, en- abling SIESTA to simulate high spatial-resolution scenarios in under an hour for the first time.

Seal, Sudip K↗

In situ electrochemical scanning/transmission electron microscopy of electrode–electrolyte interfaces

Insights into the dynamics of electrochemical processes are critically needed to improve our fundamental understanding of electron, charge, and mass transfer mechanisms and reaction kinetics that influence a broad range of applications, from the functionality of electrical energy-storage and conversion devices (e.g., batteries, fuel cells, and supercapacitors), to materials degradation issues (e.g., corrosion and oxidation), and materials synthesis (e.g., electrodeposition). To unravel these processes, in situ electrochemical scanning/transmission electron microscopy (ec-S/TEM) was developed to permit detailed site-specific characterization of evolving electrochemical processes that occur at electrode–electrolyte interfaces in their native electrolyte environment, in real time and at high-spatial resolution. This approach utilizes “closed-form” microfabricated electrochemical cells that couple the capability for quantitative electrochemical measurements with high spatial and temporal resolution imaging, spectroscopy, and diffraction. Here, we review the state-of-the-art instrumentation for in situ ec-S/TEM and how this approach has resulted in new observations of electrochemical processes.

25 ENERGY STORAGE↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA#s Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists have used the SSC V&V site to characterize thermal infrared systems. Enhancements are being considered to characterize active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. Similar techniques are used to characterize moderate spatial resolution sensing systems at selected nearby locations. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

The Velociprobe: An ultrafast hard X-ray nanoprobe for high-resolution ptychographic imaging

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 x 10 4 resolution elements per second

36 MATERIALS SCIENCE↗

Overlapping MALDI-Mass Spectrometry Imaging for In-Parallel MS and MS/MS Data Acquisition without Sacrificing Spatial Resolution

Metabolomics experiments require chemical identifications, often through MS/MS analysis. In mass spectrometry imaging (MSI), this necessitates running several serial tissue sections or using a multiplex data acquisition method. We have previously developed a multiplex MSI method to obtain MS and MS/MS data in a single experiment to acquire more chemical information in less data acquisition time. In this method, each raster step is composed of several spiral steps and each spiral step is used for a separate scan event (e.g., MS or MS/MS). One main limitation of this method is the loss of spatial resolution as the number of spiral steps increases, limiting its applicability for high-spatial resolution MSI. In this work, we demonstrate multiplex MS imaging is possible without sacrificing spatial resolution by the use of overlapping spiral steps, instead of spatially separated spiral steps as used in the previous work. Significant amounts of matrix and analytes are still left after multiple spectral acquisitions, especially with nanoparticle matrices, so that high quality MS and MS/MS data can be obtained on virtually the same tissue spot. This method was then applied to visualize metabolites and acquire their MS/MS spectra in maize leaf cross-sections at 10 μm spatial resolution. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exoplanet Sciences with Nulling Interferometers and a Single-mode Fiber-fed Spectrograph

Understanding the atmospheres of exoplanets is a milestone to decipher their formation history and potential habitability. High-contrast imaging and spectroscopy of exoplanets is the major pathway toward the goal. Direct imaging of an exoplanet requires high spatial resolution. Interferometry has proven to be an effective way of improving spatial resolution. However, means of combining interferometry, high-contrast imaging, and high-resolution spectroscopy have been rarely explored. To fill in the gap, we present the dual-aperture fiber nuller (FN) for current-generation 8–10 m telescopes, which provides the necessary spatial and spectral resolution to (1) conduct follow-up spectroscopy of known exoplanets and (2) detect planets in debris-disk systems. The concept of feeding an FN to a high-resolution spectrograph can also be used for future space and ground-based missions. We present a case study of using the dual-aperture FN to search for biosignatures in rocky planets around M stars for a future space interferometry mission. Moreover, we discuss how an FN can be equipped on future extremely large telescopes by using the Giant Magellan Telescope as an example.

79 ASTRONOMY AND ASTROPHYSICS↗

NASA's Next Generation of Atmospheric Data Science

The Multi-Angle Imager for Aerosols (MAIA) and the Tropospheric Emission: Monitoring of Pollution(TEMPO) are NASA’s next-generation satellite missions for air quality monitoring. These missions will produce high-quality, high-resolution air quality data to support cross-displinary research. The MAIA mission is collaborating with health science researchers and epidemiologists to study the impacts of air quality on health outcomes. TEMPO aims to improve our understanding of tropospheric air pollution chemistry and our ability to make predictions about air quality and climate forcing. TEMPO will offer hourly measurements of tropospheric ozone, aerosols, and clouds focused on North America at high-spatial resolution, while MAIA will produce high-resolution measurements of speciated particulate matter targeting densely populated cities around the globe. Data from these missions will help improve our understanding of the sources, types, and interactions among the aerosols and trace gases that are polluting Earth’s atmosphere, as well as our understanding of the impact of air pollution on pollution on a wide range of important areas including human health, agriculture, weather, and climate change. The challenges of cross-disciplinary research, computationally expensive multi-variate analyses, and high-resolution data at both local and global scales are driving substantial changes across all of NASA’s Distributed Active Archive Centers (DAACs). High resolution data at scales such these requires a new approach to data ingest, archive, and publication. Like other NASA DAACs, the Atmospheric Science Data Center (ASDC), the DAAC that will be responsible for publishing MAIA and TEMPO data products has historically archived and distributed data on premise. DAACs of the future will archive and distribute data in the cloud, enabling them to remake themselves as research-focused data centers that will support on-demand, data-intensive computations for highly accurate retrospective analyses and predictions. Under the new paradigm, data formats and metadata must support on-demand spatial and temporal sub-setting, as well as other data transformation services such as re-gridding and re-sampling. This presentation will discuss work being done to address data formatting and metadata requirements in this dynamic new environment. In addition to the changes in data stewardship practices at the ASDC, the increased focus on supporting scientific research is driving changes in the relationship between DAACs and researchers. While the ASDC will continue to provide first rate data management and stewardship, it is increasingly focused on serving as a partner not only to the science teams that gather and produce the data it publishes, but to the researchers that use that data.

Beth Huffer↗

The first ISLSCP field experiment (FIFE)

The background and planning of the first International Satellite Land Surface Climatology Project (ISLSCP) field experiment (FIFE) are discussed. In FIFE, the NOAA series of satellites and GOES will be used to provide a moderate-temporal resolution coarse-spatial resolution data set, with SPOT and aircraft data providing the high-spatial resolution pointable-instrument capability. The paper describes the experiment design, the measurement strategy, the configuration of the site of the experiment (which will be at and around the Konza prairie near Manhattan, Kansas), and the experiment's operations and execution.

Sellers, P. J.↗