Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Communication: Spectroscopic phase and lineshapes in high-resolution broadband sum frequency vibrational spectroscopy: Resolving interfacial inhomogeneities of "identical" molecular groups

The ability to achieve sub-wavenumber resolution (0.6 cm-1) and large signal-to-noise ratios in high-resolution broadband sum-frequency generation vibrational spectroscopy (HR-BB-SFG-VS) allows for the detailed SFG spectral lineshapes to be used in the unambiguous determination of fine spectral features. Changes in the structural spectroscopic phase in SFG-VS as a function of beam polarization and experimental geometry proved to be instrumental in the identification of an unexpected 2.78 +/- 0.07 cm-1 spectral splitting for two methyl groups at the vapor/dimethyl sulfoxide liquid interface, as well as in the determination of their orientational angles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flight test techniques for validating simulated nuclear electromagnetic pulse aircraft responses

An attempt has been made to determine the effects of nuclear EM pulses (NEMPs) on aircraft systems, using a highly instrumented NASA F-106B to document the simulated NEMP environment at the Kirtland Air Force Base's Vertically Polarized Dipole test facility. Several test positions were selected so that aircraft orientation relative to the test facility would be the same in flight as when on the stationary dielectric stand, in order to validate the dielectric stand's use in flight configuration simulations. Attention is given to the flight test portions of the documentation program.

Winebarger, R. M.↗

Lightning on Venus

On the night side of Venus, the plasma wave instrument on the Pioneer-Venus Orbiter frequently detects strong and impulsive low-frequency noise bursts when the local magnetic field is strong and steady and when the field is oriented to point down to the ionosphere. The signals have characteristics of lightning whistlers, and an attempt was made to identify the sources by tracing rays along the B-field from the Orbiter down toward the surface. An extensive data set strongly indicates a clustering of lightning sources near the Beta and Phoebe Regios, with additional significant clustering near the Atla Regio at the eastern edge of Aphrodite Terra. These results suggest that there are localized lightning sources at or near the planetary surface.

Scarf, F. L.↗

Phase closure with a rotational shear interferometer

A simple and efficient way is proposed for achieving phase closure in an optical telescope (to enable recovering Fourier transform phases that would otherwise be corrupted by atmospheric and instrumental errors), by means of rotational shear interferometry. In a rotational shear interferometer, one images the telescope aperture onto the interferometer and then interferes the aperture with itself in a rotated orientation. To achieve the maximum frequency content permitted by the telescope, the shear has to be 180 deg, but better dynamic range and SNR are possible for lower frequencies. Drawbacks of the proposed method compared to radio astronomy are noted, and different approaches are indicated as to how to collect and use the phase closure data. Phase closure can be realized on existing telescopes and existing interferometers with special modifications. Although not all base lines are possible, the extra constraints provided by the closure phases greatly reduce the ambiguity now existing in phaseless image reconstruction.

Ribak, Erez↗

Covering a Crucible with Metal Containing Channels

In a procedure that partly resembles the lost-wax casting process, a crucible made of a brittle material (ceramic, quartz, or glass) is covered with a layer of metal containing channels. The metal cover and the channels can serve any or all of several purposes, depending upon the application: Typically, the metal would serve at least partly to reinforce the crucible. The channels could be used as passages for narrow objects that could include thermocouples and heat-transfer strips. Alternatively or in addition, channels could be used as flow paths for liquid or gaseous coolants and could be positioned and oriented for position- or direction-selective cooling. In some cases, the channels could be filled with known gases and sealed so that failure of the crucibles could be indicated by instruments that detect the gases. The process consists of three main steps. In the first step, a pattern defining the channels is formed by wrapping or depositing a material in the desired channel pattern on the outer surface of the crucible. The pattern material can be a plastic, wax, low-ash fibrous material, a soluble material, or other suitable material that can subsequently be removed easily. In a proof-of-concept demonstration (see figure), the crucible was an alumina cylinder and the mold material was plastic tie-down tape. In the second step, the patterned crucible is coated with metal. In one variation of the second step, a very thin layer containing or consisting of an electrically conductive material (e.g., gold, silver, or carbon) is painted or otherwise deposited on the mold-covered crucible, then the covering metal required for the specific application is electrodeposited on the very thin conducting layer. In another variation of the second step, the metal coat is formed by chemical vapor deposition. In the proof-of-concept demonstration, a layer of nickel 0.003 in. ( 0.08 mm) thick was electrodeposited. In the third step, the patterned material is removed. This is generally done by heating the crucible assembly until the patterned material melts and runs out, vaporizes, and/or decomposes to an ash, leaving the channels. Alternatively, if the patterned material is soluble, it can be removed by use of a suitable solvent. In the proof-of-concept demonstration, the tape was burned away by heating the assembly to a temperature of 600 C.

Grugel, Richard N.↗

South pole bang-time diagnostic on the National Ignition Facility

The south pole bang-time (SPBT) diagnostic views National Ignition Facility (NIF) implosions through the lower hohlraum laser entrance hole to measure the time of peak x-ray emission (peak compression) in indirect drive implosions. Five chemical-vapor-deposition (CVD) diamond photoconductive detectors (PCD's) with different filtrations and sensitivities record the time-varying x rays emitted by the target. Wavelength-selecting highly oriented pyrolytic graphite (HOPG) crystal mirror monochromators increase the x-ray signal-to-background ratio by filtering for 11-keV emission. Diagnostic timing and the in-situ temporal instrument response function are determined from laser impulse shots on the NIF. After signal deconvolution and background removal, the bang time is determined to 45-ps accuracy. The x-ray 'yield' (mJ/sr/keV at 11 keV) is determined from the total area under the peak.

36 MATERIALS SCIENCE↗

Effects of Low Earth Orbit on Docking Seal Materials

Spacecraft docking seals are typically made of silicone elastomers. When such seals are exposed to low Earth orbit (LEO) conditions, they can suffer damage from ultraviolet (UV) radiation and atomic oxygen (AO, or monoatomic oxygen, the predominant oxygen species in LEO). An experiment flew on the International Space Station (ISS) to measure the effects of LEO on seal materials S0383-70 and ELA-SA-401 and various mating counterface materials which included anodized aluminum. Samples flown in different orientations received different amounts of UV and AO. The hypotheses were that most of the damage would be from UV, and 10 days or more of exposure in LEO would badly damage the seals. Eighteen seals were exposed for 543 days in ram (windward), zenith (away from Earth), or wake (leeward) orientations, and 15 control samples (not flown) provided undamaged baseline leakage. To determine post-flight leak rates, each of the 33 seals were placed in an O-ring groove of a leak test fixture and pressure tested over time. Resistance temperature detectors (RTDs), pressure transducers, and LabVIEW (National Instruments) programs were used to measure and analyze the temperature and pressure and calculate leakage. Average leakage of control samples was 2.6 x 10(exp -7) lbs/day. LEO exposure did not considerably damage ELA-SA-401. The S0383-70 flight samples leaked at least 10 times more than ELA-SA-401 in all cases except one, demonstrating that ELA-SA-401 may be a more suitable sealing material in LEO. AO caused greater damage than UV; samples in ram orientation (receiving an AO fluence of 4.3 x 10(exp 21) atoms/(sq cm) and in wake (2.9x 10(exp 20) atoms/(sq cm)) leaked more than those in zenith orientation (1.58 x 10(exp 20) atoms/(sq cm)), whereas variations in UV exposure did not seem to affect the samples. Exposure to LEO did less damage to the seals than hypothesized, and the data did not support the conjecture that UV causes more damage than AO.

Leakage↗

Modeling the SHG activities of diverse protein crystals

The origins of the diversity in the SHG signal from protein crystals are investigated and potential protein-crystal coverage by SHG microscopy is assessed. A symmetry-additive ab initio model for second-harmonic generation (SHG) activity of protein crystals was applied to assess the likely protein-crystal coverage of SHG microscopy. Calculations were performed for 250 proteins in nine point-group symmetries: a total of 2250 crystals. The model suggests that the crystal symmetry and the limit of detection of the instrument are expected to be the strongest predictors of coverage of the factors considered, which also included secondary-structural content and protein size. Much of the diversity in SHG activity is expected to arise primarily from the variability in the intrinsic protein response as well as the orientation within the crystal lattice. Two or more orders-of-magnitude variation in intensity are expected even within protein crystals of the same symmetry. SHG measurements of tetragonal lysozyme crystals confirmed detection, from which a protein coverage of ∼84% was estimated based on the proportion of proteins calculated to produce SHG responses greater than that of tetragonal lysozyme. Good agreement was observed between the measured and calculated ratios of the SHG intensity from lysozyme in tetragonal and monoclinic lattices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementation of new PRODIAG algorithm and simulation-based acceptance test - 219

This paper presents the improvement of an automated-reasoning computer program for nuclear power plant diagnosis, namely PRODIAG. PRODIAG, first developed at the Argonne National Laboratory, uses confluence-based reasoning to perform fault diagnosis in engineering systems that can be described by the conservation laws for mass, energy, and momentum. Therefore, unlike other plant configuration-dependent rule-based diagnosis algorithms, the code is generally applicable to a wide variety of plant configurations by simply replacing the plant instrumentation diagram (PID) database. The need for improvement was raised when the original PRODIAG failed to provide the requisite degree of extensibility and maintainability for new applications. These shortcomings have been addressed through a new code architecture that uses an objected-oriented logic-programming language in place of the original Prolog language and uses an open-source automated reasoning engine in place of the original hardwired rule-evaluation sequence. This paper presents the architecture and implementation details of the code transition. Verification and validation studies were performed for the new PRODIAG, which involved re-running the distinct fault cases defined at the time the code was originally developed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of electrons and protons on science instruments

The radiation effects on typical science instruments according to the Jupiter trapped radiation design restraint model are described, and specific aspects of the model where an improved understanding would be beneficial are suggested. The spacecraft design used is the TOPS 12L configuration. Ionization and displacement damage are considered, and damage criteria are placed on the most sensitive components. Possible protective measures are mentioned: selecting components as radiation resistant as possible, using a difference in desired and undesired signal shapes for electronic shielding, orienting and locating the component on the spacecraft for better shielding, and adding passive shields to protect specific components. Available options are listed in decreasing order of attractiveness: attempt to lower the design restraints without compromising the success of the missions, trade off experiment objectives for increased reliability, alter the trajectory, and remove sensitive instruments from the payload.

Parker, R. H.↗

Terrain Model Registration for Single Cycle Instrument Placement

This paper presents an efficient and robust method for registration of terrain models created using stereo vision on a planetary rover. Our approach projects two surface models into a virtual depth map, rendering the models as they would be seen from a single range sensor. Correspondence is established based on which points project to the same location in the virtual range sensor. A robust norm of the deviations in observed depth is used as the objective function, and the algorithm searches for the rigid transformation which minimizes the norm. An initial coarse search is done using rover pose information from odometry and orientation sensing. A fine search is done using Levenberg-Marquardt. Our method enables a planetary rover to keep track of designated science targets as it moves, and to hand off targets from one set of stereo cameras to another. These capabilities are essential for the rover to autonomously approach a science target and place an instrument in contact in a single command cycle.

Deans, Matthew↗

Instability and efficiency of mixed halide perovskites CH 3 NH 3 AI 3- x Cl x (A = Pb and Sn): A first-principles, computational study

Here, we carried out calculations based on density functional theory to investigate the electronic, vibrational, and dielectric properties of mixed halide perovskites CH 3 NH 3 AI 3– x Cl x with A = Pb and Sn. Computed free energies indicated that Cl mixed systems may be formed only for Cl concentrations not exceeding 10 19 cm –3 , and phonon calculations showed that the disorder induced in the host lattice by the presence of a smaller halogen is responsible for mechanical instabilities. However, we found that the presence of chloride may be beneficial to the electronic properties of the perovskites. Chloride anions cause the organic cations to be displaced from the center of the cage; such a displacement induces preferential orientations of the cation dipole, which in turn are responsible for notable changes in the dielectric properties of the material and possibly for the formation of local ferroelectric domains. The latter are instrumental in separating electron hole pairs and hence in contributing to long charge-carrier diffusion lengths, in spite of polarons being more likely formed in mixed perovksites than in CH 3 NH 3 AI 3 .

36 MATERIALS SCIENCE↗

Single-Crystal X-Ray Spectropolarimeter

X-ray spectropolarimetry is a diagnostics technique suitable for measuring intense electron beams and strong magnetic fields in hot, dense plasmas. To increase the accuracy achievable, we investigated the possibility of measuring both orthogonal components of linear polarization simultaneously using a single crystal. We demonstrated experimentally for the first time that crystals with cubic symmetry can be used as polarizing beam splitters. We also found that the polarization-splitting planes in cubic crystals can be accessed in two crystal orientations, a property that can be used to decrease the clutter in polarized spectra. In parallel, we developed a ray-tracing code and are working to add the crystal reflectivity to instrument modeling codes, to help us interpret the spectra and to design spectroscopic and spectropolarimetric instruments. This work is motivated by the need to perform measurements of important quantities in difficult experimental conditions, such as the axial magnetic field at stagnation in magnetized liner inertial fusion loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Neutron Macromolecular Crystallography Instruments at Oak Ridge National Laboratory: Advances, Challenges, and Opportunities

The IMAGINE and MaNDi instruments, located at Oak Ridge National Laboratory High Flux Isotope Reactor and Spallation Neutron Source, respectively, are powerful tools for determining the positions of hydrogen atoms in biological macromolecules and their ligands, orienting water molecules, and for differentiating chemical states in macromolecular structures. The possibility to model hydrogen and deuterium atoms in neutron structures arises from the strong interaction of neutrons with the nuclei of these isotopes. Positions can be unambiguously assigned from diffraction studies at the 1.5–2.5 Å resolutions, which are typical for protein crystals. Neutrons have the additional benefit for structural biology of not inducing radiation damage to protein crystals, which can be critical in the study of metalloproteins. Here we review the specifications of the IMAGINE and MaNDi beamlines and illustrate their complementarity. IMAGINE is suitable for crystals with unit cell edges up to 150 Å using a quasi-Laue technique, whereas MaNDi provides neutron crystallography resources for large unit cell samples with unit cell edges up to 300 Å using the time of flight (TOF) Laue technique. The microbial culture and crystal growth facilities which support the IMAGINE and MaNDi user programs are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface tension confined liquid cryogen cooler

A cryogenic cooler is provided for use in craft such as launch, orbital, and space vehicles subject to substantial vibration, changes in orientation, and weightlessness. The cooler contains a small pore, large free volume, low density material to restrain a cryogen through surface tension effects during launch and zero-g operations and maintains instrumentation within the temperature range of 10 to 140 K. The cooler operation is completely passive, with no inherent vibration or power requirements.

Stephen H Castles↗

Space Station Freedom as an engineering experiment station: An overview

In this presentation, the premise that Space Station Freedom has great utility as an engineering experiment station will be explored. There are several modes in which it can be used for this purpose. The most obvious are space qualification, process development, in space satellite repair, and materials engineering. The range of engineering experiments which can be done at Space Station Freedom run the gamut from small process oriented experiments to full exploratory development models. A sampling of typical engineering experiments are discussed in this session. First and foremost, Space Station Freedom is an elaborate experiment itself, which, if properly instrumented, will provide engineering guidelines for even larger structures which must surely be built if humankind is truly 'outward bound.' Secondly, there is the test, evaluation and space qualification of advanced electric thruster concepts, advanced power technology and protective coatings which must of necessity be tested in the vacuum of space. The current approach to testing these technologies is to do exhaustive laboratory simulation followed by shuttle or unmanned flights. Third, the advanced development models of life support systems intended for future space stations, manned mars missions, and lunar colonies can be tested for operation in a low gravity environment. Fourth, it will be necessary to develop new protective coatings, establish construction techniques, evaluate new materials to be used in the upgrading and repair of Space Station Freedom. Finally, the industrial sector, if it is ever to build facilities for the production of commercial products, must have all the engineering aspects of the process evaluated in space prior to a commitment to such a facility.

Rose, M. Frank↗

A satellite anemometer

We present the conceptual design of an instrument that can provide a continuous analog measure of the pitch and yaw angles of a low altitude satellite in the frame of the neutral atmosphere. The device, which uses pressure sensor orientation to provide its signal, can function in an attitude control loop and/or be used to measure atmospheric winds or wave motions. Any arbitrary angle of attack (pitch and yaw) less than +/- 45 deg can be selected for a heading. The sensitivity of the device is 0.1 deg but this would be limited by low ambient pressure at high altitudes and by multiple particle collisions in and below the slip flow region. The development of a prototype flight unit is in progress.

Hanson, W. B.↗