Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

X-ray-spectroscopy analysis of electron-cyclotron-resonance ion-source plasmas

Analysis of x-ray spectra emitted by highly charged ions in an electron-cyclotron-resonance ion source (ECRIS) may be used as a tool to estimate the charge-state distribution (CSD) in the source plasma. For that purpose, knowledge of the electron energy distribution in the plasma, as well as the most important processes leading to the creation and de-excitation of ionic excited states are needed. In this work we present a method to estimate the ion CSD in an ECRIS through the analysis of the x-ray spectra emitted by the plasma. The method is applied to the analysis of a sulfur ECRIS plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of helium ion production in constricted direct current plasma ion source with layered-glows

Generation of helium ions is experimentally investigated with a constricted direct current (DC) plasma ion source operated at layered-glow mode, in which electrons could be accelerated through multiple potential structures so as to generate helium ions including He{sup 2+} by successive ionization collisions in front of an extraction aperture. The helium discharge is sustained with the formation of a couple of stable layers and the plasma ball with high density is created near the extraction aperture at the operational pressure down to 0.6 Torr with concave cathodes. The ion beam current extracted with an extraction voltage of 5 kV is observed to be proportional to the discharge current and inversely proportional to the operating pressure, showing high current density of 130 mA/cm{sup 2} and power density of 0.52 mA/cm{sup 2}/W. He{sup 2+} ions, which were predicted to be able to exist due to multiple-layer potential structure, are not observed. Simple calculation on production of He{sup 2+} ions inside the plasma ball reveals that reduced operating pressure and increased cathode area will help to generate He{sup 2+} ions with the layered-glow DC discharge.

74 ATOMIC AND MOLECULAR PHYSICS↗

Research and development of H{sup -} ion source and low energy beam transport for a kaon-neutrino factory

A baseline H{sup -} ion source and low energy beam transport (LEBT) system have been identified for Project X. The filament-discharge H{sup -} ion source has been fabricated by D-Pace, Inc. and is now in operation at LBNL. The source is capable of delivering over 10 mA of H{sup -} beam in cw operation with normalized 4 rms emittances less than 0.7 {pi} mm mrad. A two-solenoid magnetic lens LEBT system has been design. The design has been validated with simulations of beam transport for 5 mA 30 keV H{sup -} beams using various simulation codes.

43 PARTICLE ACCELERATORS↗

Ion Source of Pure Single Charged Boron Based on Planar Magnetron Discharge in Self-Sputtering Mode

A planar magnetron sputtering device with thermally isolated sintered boron target has been designed and demonstrated. The magnetron is intended to use for generation of boron ion beams, as well as in plasma immersion implantation. For a boron target, high target temperature is required because boron has low electrical conductivity at room temperature, which increases with temperature. The target is well insulated thermally and can be heated by an initial low-current, high-voltage DC discharge mode. A discharge power of 16 W was adequate to reach the required surface temperature, after that a transition of the discharge to a high-current, low-voltage mode is observed. Applying high current pulses over the DC heating discharge results in a self-sputtering operational mode of the magnetron discharge. Ion beam was extracted from the discharge plasma. Beam analysis was performed with a time-of-flight system. All the boron ions are single charged. The maximum boron ion fraction in the beam is greater than 99%, and the mean boron ion fraction, time-integrated over the whole pulse length, is about 95%. This kind of boron ion source could be competitive to conventional boron ion sources that utilize compounds such as BF{sub 3}, and could be useful for semiconductor industry application.

36 MATERIALS SCIENCE↗

Fabrication of Impregnated-Electrode-Type Polyatomic Ion Source with Ionic Liquid

Three types of ionic liquid ion source characterized by needle-type, capillary-needle-type and impregnated-electrode-type emitters were fabricated and demonstrated. The ion emission of a pure ionic liquid was demonstrated for the capillary-needle- and impregnated-electrode-type emitters. The emission stability of the impregnated-electrode-type emitter is currently insufficient for the shallow implantation of carbon due to occasional discharge. However, the impregnated-electrode-type emitter showed the largest emission current of 14 {mu}A at 6 kV among these emitters. This was considered to be caused by the relatively high feedability of the ionic liquid obtained from the emitter tip made of porous copper.

43 PARTICLE ACCELERATORS↗

Balmer-α spectrum measurements of the LHD one-third ion source

Wavelength spectra of Balmer-α light from plasmas in the extraction region of the Large Helical Device-R&D negative ion source, or the LHD one-third ion source have exhibited a blue shift as a negative bias voltage was applied to the plasma grid. The blue shift increased as the negative bias voltage with respect to the local plasma potential was increased. The measured spectra were compared with the velocity distributions of surface reflected hydrogen atoms calculated by atomic collisions in amorphous target code. The arc power and the source H{sub 2} pressure also affected the shift and broadening in the observed Balmer-α spectra. The possibility of identifying the negative hydrogen ions produced at the low work function plasma grid surface by high resolution spectroscopy is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of multi-charged ion beams by focusing effect of mid-electrode on electron cyclotron resonance ion source

We are constructing a tandem type electron cyclotron resonance ion source (ECRIS) and a beam line for extracting ion beams. The ion beam is extracted from the second stage by an accel-decel extraction system with a single-hole and the ion beam current on each electrode is measured. The total ion beam current is measured by a faraday cup downstream the extraction electrodes. We measure these currents as a function of the mid-electrode potential. We also change the gap length between electrodes and perform similar measurement. The behaviors of these currents obtained experimentally against the mid-electrode potential show qualitatively good agreement with a simple theoretical consideration including sheath potential effects. The effect of mid-electrode potential is very useful for decreasing the beam loss for enhancing ion beam current extracted from ECRIS.

43 PARTICLE ACCELERATORS↗

A review of ion sources for medical accelerators (invited)

There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10{sup 10} pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 10{sup 8} or 10{sup 9} pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.

43 PARTICLE ACCELERATORS↗

VUV emission spectroscopy diagnostics of a 14 GHz ECR negative hydrogen ion source

Vacuum Ultra Violet(VUV) emission from a 4 cm diameter 2 cm long compact ion source excited by 14 GHz microwave has been investigated. Intensity ratio of band spectrum emission near Ly-α to Ly-α line spectrum is determined from the measured spectrum. which shows preferential excitation of molecules near the entrance of microwave input power. The ratio does not depend strongly upon pressure nor the input microwave power when the intensity is integrated over the volume of the plasma. The spatial distribution of the spectrum intensity ratio exhibits concentrations near microwave inlet and the opposite side where the microwave matching structure is located. The ratio at these peripheral regions is about two times as high as that of the central region. The ratio increased in proportion to the ion source pressure up to about 3.0 Pa, indicating efficient production of high energy electrons by ECR up to this pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Erosion of Extraction Electrodes of Ion Sources due to Sputtering

The effects upon erosion due to implanted atoms in extraction electrodes of an ion source have been investigated through calculating the sputtering yields with a Monte Carlo simulation code, ACAT. The results obtained with ACAT have indicated that the sputtering yields of extraction electrodes are substantially affected by the retention of implanted atoms depending upon the mass ratio of electrode materials and extracted ions from the source plasma. The enhanced erosion takes place as the heavier ion beam species like phosphor is implanted into lighter electrode material like carbon. Additional mixing of materials arising from ion source operation, such as hot cathode materials evaporation onto a carbon extraction electrode, can shorten the lifetime of the extraction electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and investigations of the superconducting magnet system for the multipurpose superconducting electron cyclotron resonance ion source

The production of intense beams of heavy ions with electron cyclotron resonance ion sources (ECRIS) is an important request at many accelerators. According to the ECR condition and considering semi-empirical scaling laws, it is essential to increase the microwave frequency together with the magnetic flux density of the ECRIS magnet system. A useful frequency of 28 GHz, therefore, requires magnetic flux densities above 2.2 T implying the use of superconducting magnets. A cooperation of European institutions initiated a project to build a multipurpose superconducting ECRIS (MS-ECRIS) in order to achieve an increase of the performances in the order of a factor of ten. After a first design of the superconducting magnet system for the MS-ECRIS, the respective cold testing of the built magnet system reveals a lack of mechanical performance due to the strong interaction of the magnetic field of the three solenoids with the sextupole field and the magnetization of the magnetic iron collar. Comprehensive structural analysis, magnetic field calculations, and calculations of the force pattern confirm thereafter these strong interactions, especially of the iron collar with the solenoidal fields. The investigations on the structural analysis as well as suggestions for a possible mechanical design solution are given.

43 PARTICLE ACCELERATORS↗

Incremental performance improvements for a surface-convergency H- ion source

We discuss some of the interventions on LANSCE's surface-conversion negative-hydrogen ion sources to increase reliability; lifetime and output without any major re-design of the machine. LANSCE's source presently delivers a baseline 16 mA, 60 Hz, 12% duty factor beam. We describe how better quality control and processing of tungsten filaments allow the comfortable completion of 28-day run cycles, how improved temperature control of the ion source body yields an increased H{sup -} output, how higher input power through an additional filament allows operations at plasma densities while maintaining the filament lifetime and how adequate electrode biasing inside the source provide some control over the beam Twiss parameters on exit.

43 PARTICLE ACCELERATORS↗

The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O{sup 3+}–O{sup 7+} were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam current controller for laser ion source

The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

42 ENGINEERING↗

High-resolution mass spectrometer for liquid metal ion sources

Recently, a mass spectrometer for liquid metal ion sources (LMIS) has been built and set into operation. This device uses an E×B-filter as mass dispersive element and provides sufficient resolution to analyse the emission of clusters from LMIS to much higher mass ranges (>2000 amu) than commercially available mass filters for focused ion beam systems. It has also been shown that for small masses the composition of clusters from different isotopes can be resolved. Furthermore, a rather high fluence of monodisperse clusters in the range of 10{sup 6}–10{sup 7} clusters/s can be achieved with this setup. This makes it a promising tool for the preparation of mass selected clusters. In this contribution, theoretical considerations as well as technical details and the results of first measurements are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion source design for industrial applications

The design of broad-beam industrial ion sources is described. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, cathodes, and magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. There are other ways of designing most ion source components, but the designs presented are representative of current technology and adaptable to a wide range of configurations.

Kaufman, H. R.↗

Plasma meniscus and extraction electrode studies of the ISIS H{sup -} ion source

In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H{sup -} ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the present geometry requires optimization. This paper details the experimental and simulation studies performed of the plasma meniscus and the possible electrode geometry modifications needed to extract the highest quality beam.

43 PARTICLE ACCELERATORS↗

Kinetic modeling of particle dynamics in H{sup −} negative ion sources (invited)

Progress in the kinetic modeling of particle dynamics in H{sup −} negative ion source plasmas and their comparisons with experiments are reviewed, and discussed with some new results. Main focus is placed on the following two topics, which are important for the research and development of large negative ion sources and high power H{sup −} ion beams: (i) Effects of non-equilibrium features of EEDF (electron energy distribution function) on H{sup −} production, and (ii) extraction physics of H{sup −} ions and beam optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗