Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

SU-E-J-116: Uncertainties Associated with Dose Summation of High-Dose Rate Brachytherapy and Intensity Modulated Radiotherapy for Gynecological Cases

Purpose: Determining the cumulative dose distribution (CDD) for gynecological patients treated with both high-dose rate (HDR) brachytherapy and intensity-modulated radiotherapy (IMRT) is challenging. The purpose of this work is to study the uncertainty of performing this with a structure-guided deformable (SGD) approach in Velocity. Methods: For SGD, the Hounsfield units inside specified contours are overridden to set uniform values. Deformable image registration (DIR) is the run on these process images, which forces the DIR to focus on these contour boundaries. 18 gynecological cancer patients were used in this study. The original bladder and rectum planning contours for these patients were used to drive the SGD. A second set of contours were made of the bladder by the same person with the intent of carefully making them completely consistent with each other. This second set was utilized to evaluate the spatial accuracy of the SGD. The determined spatial accuracy was then multiplied by the local dose gradient to determine a dose uncertainty associated with the SGD dose warping. The normal tissue complication probability (NTCP) was then calculated for each dose volume histogram (DVH) that included four different probabilistic uncertainties associated with the spatial errors (e.g., 68.3% and 95.4%). Results: The NTCPs for each DVH (e.g., NTCP-−95.4%, NTCP-−68.3%, NTCP-68.3%, NTCP-95.4%) differed amongst patients. All patients had an NTCP-−95.4% close to 0%, while NTCP-95.4% ranged from 0.67% to 100%. Nine patients had an NTCP-−95.4% less than 50% while the remaining nine patients had NTCP-95.4% greater than 50%. Conclusion: The uncertainty associated with this CDD technique renders a large NTCP uncertainty. Thus, it is currently not practical for clinical use. The two ways to improve this would be to use more precise contours to drive the SGD and to use a more accurate DIR algorithm.

60 APPLIED LIFE SCIENCES↗

GSV Annotated Bibliography

The following annotated bibliography was developed as part of the Geospatial Algorithm Veri cation and Validation (GSV) project for the Simulation, Algorithms and Modeling program of NA-22. Veri cation and Validation of geospatial image analysis algorithms covers a wide range of technologies. Papers in the bibliography are thus organized into the following ve topic areas: Image processing and analysis, usability and validation of geospatial image analysis algorithms, image distance measures, scene modeling and image rendering, and transportation simulation models.

99 GENERAL AND MISCELLANEOUS↗

GSV Annotated Bibliography

The following annotated bibliography was developed as part of the geospatial algorithm verification and validation (GSV) project for the Simulation, Algorithms and Modeling program of NA-22. Verification and Validation of geospatial image analysis algorithms covers a wide range of technologies. Papers in the bibliography are thus organized into the following five topic areas: Image processing and analysis, usability and validation of geospatial image analysis algorithms, image distance measures, scene modeling and image rendering, and transportation simulation models. Many other papers were studied during the course of the investigation including. The annotations for these articles can be found in the paper "On the verification and validation of geospatial image analysis algorithms".

99 GENERAL AND MISCELLANEOUS↗

Poblano v1.0 : a Matlab toolbox for gradient-based optimization.

We present Poblano v1.0, a Matlab toolbox for solving gradient-based unconstrained optimization problems. Poblano implements three optimization methods (nonlinear conjugate gradients, limited-memory BFGS, and truncated Newton) that require only first order derivative information. In this paper, we describe the Poblano methods, provide numerous examples on how to use Poblano, and present results of Poblano used in solving problems from a standard test collection of unconstrained optimization problems.

99 GENERAL AND MISCELLANEOUS↗

Machine learning technique to identify grains in polycrystalline materials samples

A method of identifying grains in polycrystalline materials, the method including (a) identifying local crystal structure of the polycrystalline material based on neighbor coordination or pattern recognition machine learning, the local crystal structure including grains and grain boundaries, (b) pre-processing the grains and the grain boundaries using image processing techniques, (c) conducting grain identification using unsupervised machine learning; and (d) refining a resolution of the grain boundaries.

Sankaranarayanan, Subramanian↗

Super-resolution and super-localization microscopy: A novel tool for imaging chemical and biological processes

Optical microscopy imaging of single molecules and single particles is an essential method for studying fundamental biological and chemical processes at the molecular and nanometer scale. The best spatial resolution (~ λ/2) achievable in traditional optical microscopy is governed by the diffraction of light. However, single molecule-based super-localization and super-resolution microscopy imaging techniques have emerged in the past decade. Individual molecules can be localized with nanometer scale accuracy and precision for studying of biological and chemical processes.This work uncovered the heterogeneous properties of the pore structures. In this dissertation, the coupling of molecular transport and catalytic reaction at the single molecule and single particle level in multilayer mesoporous nanocatalysts was elucidated. Most previous studies dealt with these two important phenomena separately. A fluorogenic oxidation reaction of non-fluorescent amplex red to highly fluorescent resorufin was tested. The diffusion behavior of single resorufin molecules in aligned nanopores was studied using total internal reflection fluorescence microscopy (TIRFM).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-invasive in-situ imaging of interior of nuclear reactors

Techniques, systems, and devices are disclosed for non-invasive monitoring and imaging of nuclear fuel inside a nuclear reactor using muon detector arrays. In one aspect, these detector arrays are placed outside the reactor vessel or building for investigating the reactors without access to the cores, therefore the imaging process is non-invasive. In some implementation, these detector arrays measure both muon scattering and absorption to enable imaging and characterizing not only the very high-Z fuel materials, but also other materials in the reactor, thereby obtaining a more complete picture of reactor status. When applied to damaged reactors, the disclosed proposed techniques, systems, and devices, through the process of providing an image, can reveal the presence (or absence) of damage to fuel rod assemblies or puddles of molten fuel at the bottom of the containment vessel, thus providing crucial information to guide decisions about remedial actions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Handheld multi-sensor biometric imaging device and processing pipeline

A handheld biometric imaging device having an array of cameras configured to simultaneously capture face, iris and fingerprint biometrics of a subject. The device includes a plurality of visible-light cameras and a plurality of infrared-light cameras capable of being triggered simultaneously to obtain a plurality of images from which a 3D image of the light field can be constructed. The device includes a plurality of visible-light illuminators and a plurality of infrared-light illuminators that allow images of a subject to be captured under different lighting profiles. The device may include an onboard control system that is capable of reconstructing a face region, an iris region and a fingerprint region from the 3D light-field image, and then extract a corresponding face template, an iris template, and a fingerprint template from the respective reconstructed regions. The extracted face, iris, and fingerprint templates may be used for enrollment and/or comparison against a biometric-template database associated with one or more watchlists.

Bolme, David S.↗

Estimating scatter in cone beam CT with striped ratio grids: A preliminary investigation

Purpose: To propose a new method for estimating scatter in x-ray imaging. Conventional antiscatter grids reject scatter at an efficiency that is constant or slowly varying over the surface of the grid. A striped ratio antiscatter grid, composed of stripes that alternate between high and low grid ratio, could be used instead. Such a striped ratio grid would reduce scatter-to-primary ratio as a conventional grid would, but more importantly, the signal discontinuities at the boundaries of stripes can be used to estimate local scatter content. Methods: Signal discontinuities provide information on scatter, but are contaminated by variation in primary radiation. A nonlinear image processing algorithm is used to estimate the scatter content in the presence of primary variation. We emulated a striped ratio grid by imaging phantoms with two sequential CT scans, one with and one without a conventional grid. These two scans are processed together to mimic a striped ratio grid. This represents a best case limit of the striped ratio grid, in that the extent of grid ratio modulation is very high and the scatter contrast is maximized. Results: In a uniform cylinder, the striped ratio grid virtually eliminates cupping. Artifacts from scatter are improved in an anthropomorphic phantom. Some banding artifacts are induced by the striped ratio grid. Conclusions: Striped ratio grids could be a simple and effective evolution of conventional antiscatter grids. Construction and validation of a physical prototype remains an important future step.

60 APPLIED LIFE SCIENCES↗

HopBox: An image analysis pipeline to characterize hop cone morphology

Abstract Hop cone morphology can influence picking and drying ability, and color can impact consumer preference and may be indicative of quality. However, these characteristics are not generally evaluated in hop breeding programs due to the tedious nature of trait quantification and the extensive variation among cones within a genotype. We developed the HopBox, which is a simply constructed light box with a camera mount, and a publicly available image processing pipeline that identifies hop cones within color‐corrected images, reads a QR code within the image, and outputs data on hop cone length, width, area, perimeter, openness, weight, color, and density. The trained model was applied to images of 500 cones each from 15 replicated advanced hop genotypes from the USDA‐ARS breeding program in Prosser, Washington. Analysis of variance revealed significant ( p < 0.001) differences between genotypes for all traits measured, enabling breeders to discriminate between genotypes for selection purposes. Broad sense heritability for all traits ranged from 0.23 to 0.59. A random sampling of hop cones from the complete dataset revealed that imaging only 5–10 cones adequately captured genotypic variation and provided acceptable rank correlations ( r s > 0.75); however, increasing the sample size to 30 provided optimal precision. Instructions for constructing a HopBox and the code for the analysis pipeline are publicly available online and have wide applicability for hop breeding and research.

Altendorf, Kayla R.↗

Quantification of silicon carbide grain structure in TRISO fuel by BSE image analysis

The grain structure of the silicon carbide (SiC) layer in tristructural-isotropic (TRISO) fuels has commonly been qualified in fuel specifications based on a qualitative comparison to visual standards to ensure undesirable microstructure are not produced. This approach is inherently dependent on subjective judgement and provides limited data for analysis or comparison. An alternative method to rapidly quantify (i.e., provide a numeric measure of) the grain structure of the SiC layer in TRISO fuels has been developed. This method relies on the identification of silicon carbide grain boundaries based on brightness variation in backscattered electron (BSE) images through the application of automated image processing algorithms. The speed with which the requisite BSE imaging and analysis may be completed enables the practical use of this method on an industrial scale as a part of qualifying TRISO fuel to meet a given specification on silicon carbide grain structure, which is an important parameter for TRISO fuel performance. The method is benchmarked by comparison to prior Electron-Backscattered Diffraction (EBSD) results for TRISO particles from the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constrained GAN-Generated X-Ray CT Data For Self-Supervised And Foundation-Model Segmentation Of Concrete Microstructures

Three-dimensional characterization of materials using X-ray computed tomography (XCT) is challenging due to the complexity of internal structures, noise, and variations in resolution. Traditional computer vision models often struggle to accurately segment these images, particularly in domain-specific applications like materials science. While supervised deep learning approaches have been developed to address the limitations of conventional algorithms, they typically require large amounts of labeled training data and often fail to generalize across different datasets. Self-supervised, few-and zero-shot learning methods have gained prominence in natural image processing and segmentation tasks, but their application to scientific imaging remains limited due to the unique structural complexity, noise, and textural artifacts present in materials science data. In this work, we investigate how domain adaptation, leveraging physics-based and GAN-generated synthetic data, impacts segmentation performance. We introduce a modified Contrastive Unpaired Translation (CUT) model designed to generate realistic labeled data, which can be used for training, pre-training, and fine-tuning segmentation models for real XCT microstructure data. We evaluate the performance of two segmentation approaches: a self-supervised network (SSL-ALPNet) and a foundation model (Segment Anything Model), assessing their improvements when pre-trained and/or fine-tuned on the synthesized data. Our results demonstrate that leveraging synthetic data significantly enhances segmentation performance, particularly in challenging materials science applications.

Ziabari, Amir [ORNL] (ORCID:000000034776457X)↗

Phase diversity for advanced systems

Phase diversity (PD) is an image processing technique that operates on a collection of defocused images of a scene. The ensemble of defocused images and known defocus values are used to reconstruct the un-aberrated scene and the wavefront of the imaging system. PD has successfully been applied to imaging systems with limited fields of view (FOV) over narrow spectral bands.

Shields, Eric A.↗

Tomopy: A Python toolbox to perform X-Ray data proessing and image reconstruction.

Tomopy is a Python toolbox to perform x-ray data processing, image reconstruction and data exchange tasks at synchrotron facilities. The dependencies of the software are currently as follows: -Python related python standard library (http://docs.python.org/2/library/) numpy (http://www.numpy.org/) scipy (http://scipy.org/) matplotlib (http://matplotlip.org/) sphinx (http://sphinx-doc.org) pil (http://www.pythonware.com/products/pil/) pyhdf (http://pysclint.sourceforge.net/pyhdf/) h5py (http://www.h5py.org) pywt (http://www.pybytes.com/pywavelets/) file.py (https://pyspec.svn.sourceforge.net/svnroot/pyspec/trunk/pyspec/ccd/files.py) -C/C++ related: gridec (anonymous?? C-code written back in 1997 that uses standard C library) fftw (http://www.fftw.org/) tomoRecon (multi-threaded C++ verion of gridrec. Author: Mark Rivers from APS. http://cars9.uchicago.edu/software/epics/tomoRecon.html) epics (http://www.aps.anl.gov/epics/)

Source record↗

Tomopy: A Python toolbox to perform X-Ray data proessing and image reconstruction.

Tomopy is a Python toolbox to perform x-ray data processing, image reconstruction and data exchange tasks at synchrotron facilities. The dependencies of the software are currently as follows: -Python related python standard library (http://docs.python.org/2/library/) numpy (http://www.numpy.org/) scipy (http://scipy.org/) matplotlib (http://matplotlip.org/) sphinx (http://sphinx-doc.org) pil (http://www.pythonware.com/products/pil/) pyhdf (http://pysclint.sourceforge.net/pyhdf/) h5py (http://www.h5py.org) pywt (http://www.pybytes.com/pywavelets/) file.py (https://pyspec.svn.sourceforge.net/svnroot/pyspec/trunk/pyspec/ccd/files.py) -C/C++ related: gridec (anonymous?? C-code written back in 1997 that uses standard C library) fftw (http://www.fftw.org/) tomoRecon (multi-threaded C++ verion of gridrec. Author: Mark Rivers from APS. http://cars9.uchicago.edu/software/epics/tomoRecon.html) epics (http://www.aps.anl.gov/epics/)

Source record↗

Zero-Power Analog Optical Processing

The motivation behind this research is the growing challenge of handling the massive amounts of data generated by modern imaging systems. Conventional digital image processing techniques are struggling to keep pace with the demands of high-resolution and high-speed imaging systems for remote sensing due to their high-power consumption and data storage requirements. We present a novel approach based on analog photonics to address this challenge. The proposed system utilizes a silicon-photonics-based image encoder positioned after image formation and initial optical-to-electrical conversion. The photonic encoder compresses image data using a passive disordered photonic structure to perform kernel-type random projections of the raw data. The compressed data is then processed by a back-end neural network, which reconstructs the original image with high fidelity (structural similarity exceeding 90%). Our proposed approach has the potential to compress images with ~ 1000X lower power consumption compared to digital approaches with data rates exceeding 1 terapixel/second.

97 MATHEMATICS AND COMPUTING↗