Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Using low volume eDNA methods to sample pelagic marine animal assemblages

Environmental DNA (eDNA) is an increasingly useful method for detecting pelagic animals in the ocean but typically requires large water volumes to sample diverse assemblages. Ship-based pelagic sampling programs that could implement eDNA methods generally have restrictive water budgets. Studies that quantify how eDNA methods perform on low water volumes in the ocean are limited, especially in deep-sea habitats with low animal biomass and poorly described species assemblages. Using 12S rRNA and COI gene primers, we quantified assemblages comprised of micronekton, coastal forage fishes, and zooplankton from low volume eDNA seawater samples (n = 436, 380–1800 mL) collected at depths of 0–2200 m in the southern California Current. We compared diversity in eDNA samples to concurrently collected pelagic trawl samples (n = 27), detecting a higher diversity of vertebrate and invertebrate groups in the eDNA samples. Differences in assemblage composition could be explained by variability in size-selectivity among methods and DNA primer suitability across taxonomic groups. The number of reads and amplicon sequences variants (ASVs) did not vary substantially among shallow (<200 m) and deep samples (>600 m), but the proportion of invertebrate ASVs that could be assigned a species-level identification decreased with sampling depth. Using hierarchical clustering, we resolved horizontal and vertical variability in marine animal assemblages from samples characterized by a relatively low diversity of ecologically important species. Low volume eDNA samples will quantify greater taxonomic diversity as reference libraries, especially for deep-dwelling invertebrate species, continue to expand.

59 BASIC BIOLOGICAL SCIENCES↗

Real sample temperature: a critical issue in the experiments of nuclear resonant vibrational spectroscopy on biological samples

There are several practical and intertangled issues which make the experiments of nuclear resonant vibrational spectroscopy (NRVS) on biological samples difficult to perform. The sample temperature is one of the most important issues. In NRVS the real sample temperatures can be very different from the readings on the temperature sensors. In this study the following have been performed: (i) citing and analyzing various existing NRVS data to assess the real sample temperatures during the NRVS measurements and to understand their trends with the samples’ loading conditions; (ii) designing several NRVS measurements with (Et 4 N)[FeCl 4 ] to verify these trends; and (iii) proposing a new sampleloading procedure to achieve significantly lower real sample temperatures and to balance among the intertangled experimental issues in biological NRVS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Proposed Science Requirements and Acquisition Priorities for the First Mars Sample Return

A sample return mission is an important next step in the exploration of Mars. The first sample return should come early in the program time-line because the science derived from earth-based analyses of samples provides crucial "ground truth" needed for further exploration planning, enhancement of remote measurements, and achieving science goals and objectives that include: (1) the search for environments that may support life and any indicators of the past or present existence of life, (2) understanding the history of water and climate on Mars, (3) understanding the evolution of Mars as a planet. Returned samples from Mars will have unique value because they can be studied by scientists worldwide using the most powerful analytical instruments available. Furthermore, returned Mars samples can be preserved for studies by future generations of scientists using new techniques and addressing new issues in Mars science. To ensure a high likelihood of success, the first sample return strategy should be simple and focused. We outline a fundamental set of sample requirements and acquisition priorities for Mars sample return.

Agee, C. B.↗

Intern Designed Modules for Conducting Potential Microgravity Solidification Experiments Aboard the International Space Station

MMaJIC (Microgravity Materials Joining Investigation Chamber) is a modular experiment chamber for performing materials science investigations. MMaJIC was initially designed to provide a controlled and sealed test environment to accommodate a wide variety of soldering and brazing experiments. However, its modular cartridge design is well suited to easily conduct any number and variety of science experiments. SoLIDD (Solid Liquid Interface Directional Device) is an apparatus for conducting directional solidification experiments with low melting temperature alloys. It has capability for varying the sample’s temperature gradient and growth velocity thus ensuring microstructural development under controlled conditions. ICED-T (Interface Control Experiment with Directional Translation) is an apparatus that conducts directional solidification experiments of transparent materials such that direct observation/recording of the advancing solid/liquid interface can be made. Currently, it is a functional breadboard that consists of the components mounted to a surface that allows the sample to be placed in an upright position. Orientation of the experiment (solid on the bottom, liquid on top) is important during testing ground samples to maintain stability. Ultimately, the goal of MMaJIC, SoLIDD and ICED-T is to conduct successful ground tests and then be re-configured for eventual use by aboard the ISS.

McElderry, Justin↗

Thermal Design, Analysis, and Sensitivity of a Sample Tube on the Martian Surface

NASA will launch a rover to Mars in 2020 to collect and cache samples of Martian rocks and regolith for potential return to Earth on a future mission. The collected samples will be placed in tubes, hermetically sealed, and deposited on the surface of Mars for a period of up to 10 years. Preventing the deposited samples from overheating is an important consideration in order to ensure their scientific integrity. The samples are required to remain below 60 °C, however there is a goal to keep them below 40 °C. This temperature requirement is challenging, considering that the maximum surface temperature of Mars is 38 °C and the tube must be thermally controlled through only passive means. As a result, a significant effort has been made to design a tube to contain the samples and investigate innovative tube surface treatments that maintain proper sample temperatures without significant adverse effects of sample contamination. The tube uses a specialized aluminum oxide coating to prevent overheating on the Martian surface. The maximum predicted tube temperature is relatively insensitive to local thermal inertia, ground contact, and ground slope, but is very sensitive to landing site latitude and dust deposition. The maximum predicted sample temperature in the +/- 30° landing latitude range with worst case assumptions is 54 °C, but many of the potential landing sites have significantly cooler maximum predicted sample temperatures. This paper describes the thermal design, analysis, and sensitivity studies performed on the sample tubes and also discusses operational considerations.

Novak, Keith↗

DO BARS DRIVE SPIRAL DENSITY WAVES?

We present deep near-infrared K{sub s} -band Anglo-Australian Telescope Infrared Imager and Spectrograph observations of a selected sample of nearby barred spiral galaxies, including some with the strongest known bars. The sample covers a range of Hubble types from SB0{sup -} to SBc. The goal is to determine if the torque strengths of the spirals correlate with those of the bars, which might be expected if the bars actually drive the spirals as has been predicted by theoretical studies. This issue has implications for interpreting bar and spiral fractions at high redshift. Analysis of previous samples suggested that such a correlation exists in the near-infrared, where effects of extinction and star formation are less important. However, the earlier samples had only a few excessively strong bars. Our new sample largely confirms our previous studies, but still any correlation is relatively weak. We find two galaxies, NGC 7513 and UGC 10862, where there is only a weak spiral in the presence of a very strong bar. We suggest that some spirals probably are driven by their bars at the same pattern speed, but that this may be only when the bar is growing or if there is abundant gas and dissipation.

79 ASTRONOMY AND ASTROPHYSICS↗

Current and future federal and state sampling guidance for per- and polyfluoroalkyl substances in environmental matrices

Per- and polyfluoroalkyl substances (PFAS) are a class of emerging contaminants composed of an estimated 5000 to 10,000 human-made, fluorinated, organic chemicals. Due to the complexity of PFAS, the need for multiple environmental matrix considerations and the absence of a promulgated federal standard for environmental sampling and analysis, U.S. states have begun developing health-based regulatory and/or guidance values for a limited number of PFAS in environmental matrices. As there is a growing body of science to inform PFAS sampling guidance standard development, it is important to understand which U.S. states are implementing sampling guidelines and how they plan to handle emerging PFAS. This critical review discusses the current and impending federal and state sampling guidelines for PFAS in environmental matrices, the data gaps surrounding PFAS sampling guidance in U.S. states, and the future impacts of impending guidance documents and regulations. Ten federal guidance documents are available for PFAS sampling guidance and analysis. The maximum number of PFAS covered in these guidance documents is 25 analytes spanning across 8 unique media. While the EPA has developed several different sampling and analytical guidelines for PFAS, there is no formal regulation of PFAS or requirements of states to enforce these guidelines. Consequently, only 31 states have informally adopted sampling guidelines, while the other 19 states have no guidance documentation in place for PFAS. The introduction of new PFAS sampling guidelines by the EPA, as well as updated analytical guidelines that target more PFAS or total organofluoride, is expected to continuously shift the landscape of federal and state guidance for PFAS sampling moving forward.

54 ENVIRONMENTAL SCIENCES↗

Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗

Sample preparation with sucrose cryoprotection dramatically alters Zn distribution in the rodent hippocampus, as revealed by elemental mapping

Transition metal ions (Fe, Mn, Cu, Zn) are essential for healthy brain function, but altered concentration, distribution, or chemical form of the metal ions has been implicated in numerous brain pathologies. Currently, it is not possible to image the cellular or sub-cellular distribution of metal ions in vivo and therefore, studying brain-metal homeostasis largely relies on ex vivo in situ elemental mapping. Sample preparation methods that accurately preserve the in vivo elemental distribution are essential if one wishes to translate the knowledge of elemental distributions measured ex vivo toward increased understanding of chemical and physiological pathways of brain disease. Furthermore, the choice of sample preparation is particularly important for metal ions that exist in a labile or mobile form, for which the in vivo distribution could be easily distorted by inappropriate sample preparation. One of the most widely studied brain structures, the hippocampus, contains a large pool of labile and mobile Zn. Herein, we describe how sucrose cryoprotection, the gold standard method of preparing tissues for immuno-histochemistry or immuno-fluorescence, which is also often used as a sample preparation method for elemental mapping studies, drastically alters hippocampal Zn distribution. Based on the results of this study, in combination with a comparison against the strong body of published literature that has used either rapid plunge freezing of brain tissue, or sucrose cryo-protection, we strongly urge investigators in the future to cease using sucrose cryoprotection as a method of sample preparation for elemental mapping, especially if Zn is an analyte of interest.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced Iron Solubility at Low pH in Global Aerosols

The composition and oxidation state of aerosol iron were examined using synchrotron-based iron near-edge X-ray absorption spectroscopy. By combining synchrotron-based techniques with water leachate analysis, impacts of oxidation state and mineralogy on aerosol iron solubility were assessed for samples taken from multiple locations in the Southern and the Atlantic Oceans; and also from Noida (India), Bermuda, and the Eastern Mediterranean (Crete). These sampling locations capture iron-containing aerosols from different source regions with varying marine, mineral dust, and anthropogenic influences. Across all locations, pH had the dominating influence on aerosol iron solubility. When aerosol samples were approximately neutral pH, iron solubility was on average 3.4%; when samples were below pH 4, the iron solubility increased to 35%. This observed aerosol iron solubility profile is consistent with thermodynamic predictions for the solubility of Fe(III) oxides, the major iron containing phase in the aerosol samples. Source regions and transport paths were also important factors affecting iron solubility, as samples originating from or passing over populated regions tended to contain more soluble iron. Although the acidity appears to affect aerosol iron solubility globally, a direct relationship for all samples is further confounded by factors such as anthropogenic influence, aerosol buffer capacity, mineralogy and physical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnosing the plasma nonuniformity in an iron opacity experiment by spatially resolved Al 1s-2p absorption spectroscopy

Generating a well-characterized hot-dense sample is of great importance to high quality opacity measurements. In this paper, we report on an experimental investigation of the plasma nonuniformity in a radiatively heated iron opacity sample by spatially resolved Al 1s-2p absorption spectroscopy. The iron sample was tamped by plastic at both sides and was heated by thermal x-ray radiation generated in a gold Hohlraum, and an Al layer attached to it was used as a tracer for temperature diagnosis. Spatially resolved 1s-2p transition absorption spectra of the Al tracer were measured by the technique of point-projection-spectroscopy, and temperatures in the sample were obtained by comparing the measured spectra with detailed-term-accounting model calculations, with the density of the sample deduced using a combination of side-on radiography and radiative hydrodynamic simulation. The results showed the existence of axial temperature nonuniformity in the sample, and these temperature variations have been used to explain the shift of iron 2p-3d transition absorption feature along the axial direction of the Hohlraum used to heat the sample successfully.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Bayesian Approach for Quantifying Data Scarcity when Modeling Human Behavior via Inverse Reinforcement Learning

Computational models that formalize complex human behaviors enable study and understanding of such behaviors. However, collecting behavior data required to estimate the parameters of such models is often tedious and resource intensive. Thus, estimating dataset size as part of data collection planning (also known as Sample Size Determination) is important to reduce the time and effort of behavior data collection while maintaining an accurate estimate of model parameters. In this paper, we present a sample size determination method based on Uncertainty Quantification (UQ) for a specific Inverse Reinforcement Learning (IRL) model of human behavior, in two cases: 1) pre-hoc experiment design—conducted in the planning stage before any data is collected, to guide the estimation of how many samples to collect; and 2) post-hoc dataset analysis—performed after data is collected, to decide if the existing dataset has sufficient samples and whether more data is needed. Here, we validate our approach in experiments with a realistic model of behaviors of people with Multiple Sclerosis (MS) and illustrate how to pick a reasonable sample size target. Our work enables model designers to perform a deeper, principled investigation of effects of dataset size on IRL.

97 MATHEMATICS AND COMPUTING↗

Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

A new method that rapidly preconcentrates and measures 226 Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226 Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226 Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226 Ra sample preparation takes < 2 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanical properties of reconstituted Australian black coal

Coal is usually highly heterogeneous. Great variation in properties can exist among samples obtained even at close proximity within the same seam or within the same core sample. This makes it difficult to establish a correlation between uniaxial compressive strength (UCS) and point load index for coal. To overcome this problem, a method for making reconstituted samples for laboratory tests was developed. Samples were made by compacting particles of crushed coal mixed with cement and water. These samples were allowed to cure for four days. UCS and point load tests were performed to measure the geomechanical properties of the reconstituted coal. After four days curing, the average UCS was found to be approximately 4 MPa. This technical note outlines some experimental results and correlations that were developed to predict the mechanical properties of the reconstituted black coal samples. By reconstituting the samples from crushed coal, it is hoped that the samples will retain the important mechanical and physicochemical properties of coal, including the swelling, fluid transport, and gas sorption properties of coal. The aim is to be able to produce samples that are homogeneous with properties that are highly reproducible, and the reconstituted coal samples can be used for a number of research areas related to coal, including the long-term safe storage of CO{sub 2} in coal seams.

01 COAL, LIGNITE, AND PEAT↗

The role of electron irradiation history in liquid cell transmission electron microscopy

In situ liquid cell transmission electron microscopy (LC-TEM) allows dynamic nanoscale characterization of systems in a hydrated state. Although powerful, this technique remains impaired by issues of repeatability that limit experimental fidelity and hinder the identification and control of some variables underlying observed dynamics. We detail new LC-TEM devices that improve experimental reproducibility by expanding available imaging area and providing a platform for investigating electron flux history on the sample. Irradiation history is an important factor influencing LC-TEM results that has, to this point, been largely qualitatively and not quantitatively described. We use these devices to highlight the role of cumulative electron flux history on samples from both nanoparticle growth and biological imaging experiments and demonstrate capture of time zero, low-dose images on beam-sensitive samples. In particular, the ability to capture pristine images of biological samples, where the acquired image is the first time that the cell experiences significant electron flux, allowed us to determine that nanoparticle movement compared to the cell membrane was a function of cell damage and therefore an artifact rather than visualizing cell dynamics in action. Lastly, these results highlight just a subset of the new science that is accessible with LC-TEM through the new multiwindow devices with patterned focusing aides.

59 BASIC BIOLOGICAL SCIENCES↗

Earth Microbiome Project and Global Systems Biology

Recently, we published the first large-scale analysis of data from the Earth Microbiome Project (1, 2), a truly multidisciplinary research program involving more than 500 scientists and 27,751 samples acquired from 43 countries. These samples represent myriad specimen types and span a wide range of biotic and abiotic factors, geographic locations, and physicochemical properties. The database (https://qiita.ucsd.edu/emp/) is still growing, with over 90,000 amplicon datasets, >500 metagenomic runs, and metabolomics datasets from a similar number of samples. Importantly, the techniques, data and analytical tools are all standardized and publicly accessible, providing a framework to support research at a scale of integration that just 7 years ago seemed impossible.

Gilbert, Jack A.↗