Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Silicon micromachined waveguides for millimeter and submillimeter wavelengths

The majority of radio receivers, transmitters, and components operating at millimeter and submillimeter wavelengths utilize rectangular waveguides in some form. However, conventional machining techniques for waveguides operating above a few hundred GHz are complicated and costly. This paper reports on the development of silicon micromachining techniques to create silicon-based waveguide circuits which can operate at millimeter and submillimeter wavelengths. As a first step, rectangular WR-10 waveguide structures have been fabricated from (110) silicon wafers using micromachining techniques. The waveguide is split along the broad wall. Each half is formed by first etching a channel completely through a wafer. Potassium hydroxide is used to etch smooth mirror-like vertical walls and LPCVD silicon nitride is used as a masking layer. This wafer is then bonded to another flat wafer using a polyimide bonding technique and diced into the U-shaped half wavelengths. Finally, a gold layer is applied to the waveguide walls. Insertion loss measurements show losses comparable to those of standard metal waveguides. It is suggested that active devices and planar circuits can be integrated with the waveguides, solving the traditional mounting problems. Potential applications in terahertz instrumentation technology are further discussed.

Yap, Markus↗

Ka-Band, MEMS Switched Line Phase Shifters Implemented in Finite Ground Coplanar Waveguide

Ka-band MEMS switched line phase shifters implemented in finite ground coplanar waveguide are described in this paper. The phase shifters are constructed of single-pole double-throw (SPDT) switches with additional reference and phase offset transmission line lengths. The one- and two-bit phase shifters are fabricated on high resistivity (HR) silicon with a dielectric constant, Epsilon(sub T) = 11.7 and a substrate thickness, t = 500microns. The switching architectures integrated within the phase shifters consist of MEMS switches that are doubly anchored cantilever beam capacitive switches with additional high inductive sections (MEMS LC device). The SPDT switch is composed of a T-junction with a MEMS LC device at each output port. The one-bit phase shifter described in this paper has an insertion loss (IL) and return loss (RL) of 0.9 dB and 30 dB while the two-bit described has an IL and RL of 1.8 dB and 30 dB respectively. The one-bit phase shifter's designed offset phase is 22.5deg and actual measured phase shift is 21.8deg. The two-bit phase shifter's designed offset phase is 22.5deg, 45deg, and 67.5deg and the actual measured phase shifts are 21.4deg, 44.2deg, and 65.8deg, respectively.

Scardelletti, Maximilian C.↗

Development of Urine Receptacle Assembly for the Crew Exploration Vehicle

The Urine Receptacle Assembly (URA) initially was developed for Apollo as a primary means of urine collection. The aluminum housing with stainless steel honeycomb insert provided all male crewmembers with a non-invasive means of micturating into a urine capturing device and then venting to space. The performance of the URA was a substantial improvement over previous devices but its performance was not well understood. The Crew Exploration Vehicle (CEV) program is exploring the URA as a contingency liquid waste management system for the vehicle. URA improvements are required to meet CEV requirements, including: consumables minimization, flow performance, acceptable hygiene standards, crew comfort, and female crewmember capability. This paper presents the results of a historical review of URA performance during the Apollo program, recent URA performance tests on the reduced gravity aircraft flight under varying flow conditions, and a proposed development plan for the URA to meet CEV needs.

Cibuzar, Branelle Rae↗

Ultra-compact configurable double-sided manifold micro-channel cold plate

A configurable, double sided, manifold micro-channel cold plate includes a one or more manifold micro-channel cold plate cells. Each cold plate cell includes a manifold body, a manifold insert, a plurality of heat sinks, and a plurality of longitudinal openings configured for fluidic communication with the fluid channels. The manifold body has fluid channels to permit flow of a fluid coolant. The manifold insert has a plurality of manifold insert fluid channels, and is configured for receipt in the one of the modular body recesses. The heat sinks are configured for receipt in the modular body recesses, and include an impingement surface configured for fluidic communication with the manifold insert fluid channels, and a heat transfer surface for thermal communication with one or more heat generating devices.

Zhou, Feng↗

SU-F-T-505: A Novel Approach for Sparing Critical Organs at Risk for Cancer Patients Undergoing Radiation Oncology Treatments

Purpose: A major goal of an effective radiation treatment plan is to deliver the maximum dose to the tumor while minimizing radiation exposure to the surrounding normal structures. For example, due to the radiation exposure to neighboring critical structures during prostate cancer treatment, a significant increase in cancer risk was observed for the bladder (77%) and the rectum (105%) over the following decade. Consequently, an effective treatment plan necessitates limiting the exposure to such organs which can best be achieved by physically displacing the organ at-risk. The goal of this study is to present a prototype for an organ re-positioner device designed and fabricated to physically move the rectum away from the path of radiation beam during external beam and brachytherapy treatments. This device affords patient comfort and provides a fully controlled motion to safely relocate the rectum during treatment. Methods: The NiTi shape memory alloy was designed and optimized for manufacturing a rectal re-positioner device through cooling and heating the core alloy for its shaping. This has been achieved through a prototyped custom designed electronic circuit in order to induce the reversible austenitic transformation and was tested rigorously to ensure the integrity of the actuated motion in displacement of the target anatomy. Results: The desirable NiTi shape-setting was configured for easy insertion and based on anatomical constraint. When the final prototype was evaluated, accuracy and precision of the maximum displacement and temperature changes revealed that the device could safely be used within the target anatomy. Conclusion: The organ re-positioner device is a promising tool that can be implemented in clinical setting. It provides a controlled and safe displacement of the delicate organ(s) at risk. The location of the organ being treated could also be identified using conventional onboard imaging devices or MV imaging available on-board most modern clinical accelerators.

60 APPLIED LIFE SCIENCES↗

Pressure-Driven Helium Insertion for Structural Stability of CH 3 NH 3 PbBr 3 Hybrid Perovskites

Organic−inorganic metal halide perovskites (MHPs) have garnered significant attention due to their outstanding performance in optoelectronic devices, but they are prone to degradation through a variety of pathways. High-pressure studies are being used to understand the mechanical and structural stability of MHPs and investigate new methods for improving these. In this study, we map the high-pressure, low-temperature structural phase diagram of CH 3 NH 3 PbBr 3 (MAPbBr 3 ) between 15−300 K and up to 1.5 GPa. We first compare the temperature and pressure effects on the global and local structures of MAPbBr 3 using synchrotron X-ray diffraction (XRD) and extended X-ray absorption fine structure (EXAFS), respectively, and find evidence of PbBr 6 octahedral distortion. Our results also suggest that He inserts into the MAPbBr 3 structure. The thermodynamics of He insertion into MAPBHe x are calculated to be plausible at room temperature for x ≤ 1 and P = 1−3 GPa and shown to stabilize higher-symmetry phases. This phenomenon increases the fitted bulk modulus of MAPbBr 3 . Structural stabilization by inert atom insertion is proposed as a method to improve the mechanical robustness of MHPs and other soft hybrid materials.

Diffraction↗

Distinguishing triplet energy transfer and trap-assisted recombination in multi-color organic light-emitting diode with an ultrathin phosphorescent emissive layer

An ultrathin layer of deep-red phosphorescent emitter tris(1-phenylisoquinoline) iridium (III) (Ir(piq){sub 3}) is inserted within different positions of the electron blocking layer fac-tris (1-phenylpyrazolato-N,C{sup 2′})-iridium(III) (Ir(ppz){sub 3}) to distinguish the contribution of the emission from the triplet exciton energy transfer/diffusion from the adjacent blue phosphorescent emitter and the trap-assisted recombination from the narrow band-gap emitter itself. The charge trapping effect of the narrow band-gap deep-red emitter which forms a quantum-well-like structure also plays a role in shaping the electroluminescent characteristics of multi-color organic light-emitting diodes. By accurately controlling the position of the ultrathin sensing layer, it is considerably easy to balance the white emission which is quite challenging for full-color devices with multiple emission zones. There is nearly no energy transfer detectable if 7 nm thick Ir(ppz){sub 3} is inserted between the blue phosphorescent emitter and the ultrathin red emitter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wall scanning probe for high-field side plasma measurements on Alcator C-Mod

A new, high-field side scanning probe has been added to Alcator C-Mod's complement of edge diagnostics. The wall scanning probe is designed to provide all the benefits of a linear plunge, multielectrode scanning probe while working from the confined space of the inner tokamak wall. The drive mechanism is an embedded coil which produces a torque with the ambient toroidal magnetic field when energized, thus allowing the probe to plunge to different preprogramed depths at different times during a plasma discharge. The probe tip is designed for easy replacement and is presently configured to operate as a modified, high heat-flux ''Gundestrup-type'' probe with four tungsten electrodes. The probe has demonstrated the ability to obtain cross-field profiles for electron temperature, density, floating potential, and plasma flow information (parallel and perpendicular to B) up to a depth of a few millimiters inside the last-closed flux surface in standard C-Mod discharges. The tungsten-tipped probe has proved very robust and shows little or no damage though it routinely handles surface heat fluxes on the order of 100 MW/m{sup 2} at peak insertion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-178: Experimental Study of Acceptable Movement Conditions for SBRT Lung Treatments

Purpose: To experimentally study the acceptable movement conditions for SBRT lung treatments we quantified with film dosimetry the change in dose distributions due to periodic movements of 5 different amplitudes and 4 respiratory gating duty cycles on a SBRT treatment plan. Methods: We planned a SBRT treatment plan for the QUASAR™ (Modus Medical) phantom equipped with the respiratory motion device. We placed a 3 mm water-equivalent sphere simulating a tumour inside the lung-equivalent insert. This sphere is divided in two hemispheres that allow placing films in between. We used radiochromic EBT2™ (Ashland) films. We oriented the lung insert in such a way that sagittal dose distributions could be measured. We applied a sinusoidal movement with 3 s period for 5 different amplitudes of 0(static), 5, 7, 10, 15 and 20 mm without gating. For the 20 mm amplitude we studied the gating technique with 4 duty cycles of 20, 40, 60 and 80% of the respiratory cycle. Each situation was irradiated in a Clinac 2100 linac (Varian) equipped with the RPM™ system. FilmQA Pro™ (Ashland) software together with an Expression 10000XL scanner (EPSON) were used to analyze and compare the measured dose distributions with those planned by the Eclipse™ TPS v. 8.9 (Varian) by means of gamma analysis with 6 criteria: 5%/3mm, 5%/2mm, 5%/1mm, 3%/3mm, 3%/2mm and 2%/2mm (threshold of 10%). Results: Movements with amplitude of less than 7mm do not significantly modified the dosimetry. Gating duty cycles of less than 40% yielded also acceptable results for a 2 cm amplitude movement. Conclusion: To safely perform daily accurate SBRT treatments, movements have to be restricted to 7 mm amplitude (±3.5 mm). Otherwise, a gating strategy should be considered.

60 APPLIED LIFE SCIENCES↗

Connector locking device

Slidable spring-loaded locking device eliminates need for safety wiring. Locking device is placed between the connector plug and connector receptacle. The threaded plug cannot vibrate loose because the insert is wedged into slots formed on the outer diameter of the receptacle.

Rabb, L. W.↗

Tool and process for miniature explosive joining of tubes

A tool and process to be used in the explosive joining of tubes is disclosed. The tool consists of an initiator, a tool form, and a ribbon explosive. The assembled tool is a compact, storable, and safe device suitable for explosive joining of small, lightweight tubes down to 0.20 inch in diameter. The invention is inserted into either another tube or a tube plate. A shim or standoff between the two surfaces to be welded is necessary. Initiation of the explosive inside the tube results in a high velocity, angular collision between the mating surfaces. This collision creates surface melts and collision bonding wherein electron-sharing linkups are formed.

Bement, Laurence J.↗

Connector systems for structures

A releasable coupling device for connecting two members to one another where a collet type fastener has normally retracted latching fingers insertable into a latching recess and a longitudinally movable expander for activating the fastener is described. The longitudinal movement is retained with a paraffin actuated system which can reset. The longitudinal movement of the expander in one direction is through a one way threaded ratchet system which provides an automatic locking action and the expander is movable in either direction by an independently operated threaded action.

Lupo, Christian↗

Connector systems for structures

A releasable coupling device for connecting two members to one another where a collet type fastener has normally retracted latching fingers insertable into a latching recess and a longitudinally movable expander for activating the fastener is described. The longitudinal movement is retained with a paraffin actuated system which can reset. The longitudinal movement of the expander in one direction is through a one way threaded ratchet system which provides an automatic locking action and the expander is movable in either direction by an independently operated threaded action.

Evenson, Erik E.↗

Video System For Inspecting Walls Of Cavities

Endoscopic video-imaging system generates panoramic image of part of wall of cavity surrounding tip of probe inserted in cavity. Not necessary to rotate probe to obtain panoramic image. If simple inspection without measurement required, device called "cylindrical light ring" mounted on probe to illuminate scene. Different illumination device used when required to measure distance of wall of cavity from cylindrical axis of probe. System used, for example, to inspect inner surface of tube, passage, or manifold located deep within engine or other complex structure.

Gilbert, John A.↗

Fiber Optic Attenuators

Mike Buzzetti designed a fiber optic attenuator while working at Jet Propulsion Laboratory, intended for use in NASA's Deep Space Network. Buzzetti subsequently patented and received an exclusive license to commercialize the device, and founded Nanometer Technologies to produce it. The attenuator functions without introducing measurable back-reflection or insertion loss, and is relatively insensitive to vibration and changes in temperature. Applications include cable television, telephone networks, other signal distribution networks, and laboratory instrumentation.

Source record↗

Printed Antennas Made Reconfigurable by Use of MEMS Switches

A class of reconfigurable microwave antennas now undergoing development comprise fairly conventional printed-circuit feed elements and radiating patches integrated with novel switches containing actuators of the microelectromechanical systems (MEMS) type. In comparison with solid-state electronic control devices incorporated into some prior printed microwave antennas, the MEMS-based switches in these antennas impose lower insertion losses and consume less power. Because the radio-frequency responses of the MEMS switches are more nearly linear, they introduce less signal distortion. In addition, construction and operation are simplified because only a single DC bias line is needed to control each MEMS actuator.

Simons, Rainee N.↗

Enhancing the thermosiphon-driven discharge of a latent heat thermal storage system used in a personal cooling device

Personal cooling devices reduce energy loads by allowing buildings to operate with elevated setpoint temperatures, without compromising on the occupant comfort. One such novel technology called the Roving Comforter (RoCo) uses a compact R134a based vapor compression system for cooling. Following its cooling operation, during which waste heat from the condensing refrigerant is stored in a phase change material (PCM), a two-phase loop thermosiphon is used to discharge (solidify) the PCM to enable its next operation. The transient operation of this thermosiphon is the focus of the present paper. Use of a PCM as the storage medium provides high energy density due to the ability to store thermal energy as latent heat during the phase transition; however, the discharge rate is limited by the low thermal conductivity of the PCM. Insertion of a graphite foam within the PCM can increase the rate of discharge and decrease the downtime of the cooling device. Since graphite enhancement involves a tradeoff between improving the discharge time at the expense of PCM volumetric latent heat, the impact of graphite foam density on the PCM discharge rate is investigated by using a Modelica-based transient model of the thermosiphon. The semi-empirical model, which uses relevant heat transfer coefficient and pressure drop correlations for both refrigerant and airside heat transfer, captures the complex phenomena involving simultaneous phase change of the refrigerant and the PCM. Finally, the graphite enhanced PCM selected from this analysis results in a 51% reduction in the discharge time with addition of only 5% to the thermal storage weight, without compromising the required cooling time.

42 ENGINEERING↗

Magneto-optic garnet and liquid crystal optical switches

Magnetic stripe domain and liquid crystal devices are being developed and evaluated as fiber optic switches that can be utilized for nonblocking type nxm optical matrix switches in networking and optical processing. Liquid crystal switches are characterized by very low insertion loss and crosstalk, while stripe domain switches commutate in less than one microsecond. Both switches operate on multimode, randomly polarized fiber light with potentially large values for (n,m). The applications of these magnetic stripe domain and liquid crystal devices are discussed.

Krawczak, J. A.↗