Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrumentation and Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Performance of a commercial transport under typical MLS noise environment

The performance of a 747-200 automatic flight control system (AFCS) subjected to typical Microwave Landing System (MLS) noise is discussed. The performance is then compared with the results from a previous study which had a B747 AFCS subjected to the MLS standards and recommended practices (SARPS) maximum allowable noise. A glide slope control run with Instrument Landing System (ILS) noise is also conducted. Finally, a linear covariance analysis is presented.

Ho, J. K.↗

Robust online monitoring for calibration assessment of transmitters and instrumentation - 260

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. A Gaussian Process (GP)-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for this purpose. The resulting models are being evaluated for use in high-confidence signal validation for the purpose of detecting and diagnosing sensor faults, and for computing virtual sensor outputs that may be used as a temporary replacement for failing sensors. In addition to assessing sensor drift, approaches for extracting sensor response time in an automated fashion were developed, for monitoring changes in sensor response time in pressure transmitters. Such changes are also indicative of various fault modes. These algorithms were evaluated with existing measurement data from several laboratory-scale flow loops. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Instrumentation Plan for the OSU High Temperature Test Facility, Revision 4

This instrumentation plan describes the instrumentation requirements and design for the Oregon State University (OSU) High Temperature Test Facility (HTTF). This report outlines HTTF instrumentation design specifications, data acquisition and control system (DACS) design specifications as well as a brief description of the instrumentation to be used in the HTTF. The HTTF is an integral test facility, which has been designed to model the behavior of interest for a Very High Temperature Gas Reactor (VHTR) during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. The maximum core power for the facility is approximately 2.2MW. The core region is of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. A correctly scaled integral facility modeling the VHTR that can be used to examine the thermal hydraulic system behavior of the design basis and beyond design basis transients is of significant value. The experimental results obtained in such a program could be used to validate analytical tools and methods being proposed for use with the VHTR. Therefore, it is of importance that the HTTF be instrumented in such a way that the required data is collected to meet its overall goals of phenomena examination and code validation. In addition to the instrumentation used to collect data to achieve the overall goals of the HTTF test program, there is instrumentation in the HTTF, which is primarily used to ensure the safe operation of the test facility. This type of instrumentation shall be termed “Control Instrumentation” and is discussed in this report. This report discusses the DACS, which is a personal computer controlled system that is used to control both the collection and storage of the test matrix and control system data as well as electrical and mechanical operation of the test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety Assurance of Software and Machine Learning Development for Nuclear Instrumentation and Controls

Digital instrumentation and control (DI&C) systems monitor and control parameters in nuclear power plants. Ensuring their safety is a critical part of ensuring overall plant safety. Nuclear power plant licensing generates thousands of safety documents that could be organized more effectively using a safety assurance case (SAC). We conducted a literature survey of SACs and created a SAC framework for DI&C software using Goal Structuring Notation (GSN). This framework focuses on four software development processes: management & assurance, pre-developed software (PDS) qualification, the Software Development Life Cycle (SDLC), and the Machine Learning Development Life Cycle (MLDLC). We organized our framework using a novel level structure that can be applied to other SACs to improve their clarity. Finally, we demonstrate how our framework can be incorporated as part of a SAC for a larger reactor system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Criteria for Determining the Safety of Wireless Technologies at Nuclear Power Plants

This report provides an initial discussion of the potential impact to safety-related/important-to-safety (SR/ITS) systems by the possible expanded use of wireless technologies. One aspect of this discussion is focused on a review of Regulatory Guide (RG) 1.180 Rev. 2 to determine whether any revisions are necessary to reflect the current state of practice in evaluating and protecting instrumentation and control (I&C) systems and components from electromagnetic interference (EMI) or radiofrequency interference (RFI) on safety and nonsafety I&C. Electromagnetic compatibility (EMC) is the ability of a device or system to function satisfactorily in its electromagnetic (EM) environment, which is achieved by limiting the unintentional generation, propagation, and reception of EM energy that may cause unwanted effects such as EMI. The goal of EMC is to ensure the correct operation of different types of equipment in a common EM environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification of the accident-related critical digital assets based on probabilistic safety analysis results - 225

Digital I and C systems have been developed and installed in nuclear power plants, and due to installation of the digital I and C systems, cyber security concerns are increasing in nuclear industry. However, there are too many critical digital assets (CDAs) to be inspected in digitalized NPPs. In order to reduce the inefficiency of regulation in nuclear facilities, the critical digital assets that are directly related to an accident are elicited by using the probabilistic safety assessment results. Target initial events are selected, and their heading are analyzed through event tree analysis. Among the headings, the headings that can be proceeded directly to the core damage by the cyber-attack are finally selected as the target of deriving the minimum cut-sets. Based on success criteria of each heading, we analyze the fault trees and derive the minimum set-cuts. In terms of original PSA, the value of probability for the cut-sets is important but the probability is not important in terms of cyber security of NPPs. The important factors is the number of basic events consisting of the minimal cut-sets that is proportional to vulnerability. Finally, the process for identifying accident-related CDAs is suggested based on PSA results. The results of this study are expected to be used to derive the linkage between cyber-attack and accident, and to develop the final core digital asset identification methodology and effective regulatory method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an Automated Software Reliability Tester for Digital I and C

Existing nuclear facilities are in the process of upgrading analog systems to new, software- based digital components; however, the qualification of these new systems has been a significant hurdle for their implementation in the United States. This paper describes the development of a Software Reliability Tester (SRT) that will provide a means to quantify the reliability and fault tolerance of digital instrumentation and control (I and C) systems used in nuclear facilities. The SRT is comprised of hardware and software that exercise digital equipment inputs and compare the outputs to expected values to quantify system reliability. Incorporation of fault injection techniques enables the SRT to evaluate the robustness of digital I and C in the presence of abnormal conditions. The integration of both quantitative reliability and fault tolerance measures will provide the nuclear industry with an automated and systematic approach to digital I and C qualification. This will enable safer, more reliable, and more cost effective implementations of a broad spectrum of digital I and C equipment in existing and next generation nuclear facilities. This paper includes a description of the design of the SRT, including software modules and the hardware interface. In addition, an example of using the SRT to automate functional testing of a digital timer relay is presented. The SRT described in this paper provides a means to conduct efficient and robust testing for a variety of digital devices. Future plans for the SRT include integrating fault injection testing so that devices can be evaluated in the presence of off-normal conditions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler

A new low budget slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought to operation at the ALS Optical Metrology Laboratory. The design, instrumental control and data acquisition system, initial alignment and calibration procedures, as well as the developed experimental precautions and procedures are described in detail. The capability of the DLTP to achieve sub-microradian surface slope metrology is verified via cross-comparison measurements with other high performance slope measuring instruments when measuring the same high quality test optics. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.

47 OTHER INSTRUMENTATION↗

Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the settings of the electronic system, such as the high voltage and the discrimination level in order to obtain all the characteristic curves of the detectors. These curves are used to define the right setting of the electronic system and to discuss the expected degradation of the detector signal resulting from the detector damage under the integrated neutron and gamma fluxes. Moreover, in addition to the study of the neutron detection systems itself, the integration of the measurements made by these detection systems in the logic of the safety system of the nuclear reactor is also addressed. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. In addition to on-reactor training, Internet Reactor Laboratory capability has been implemented on the ISIS reactor in 2014. For the Internet Reactor Laboratory an extensive video conference system has been implemented on ISIS reactor. The system includes 4 cameras and the transmission of the video signal given by the supervision system of the reactor which records and processes the data of the reactor. According to the pedagogic needs during the training courses, the lecturer on the ISIS reactor chooses to broadcast the relevant information at each stage of the course. For example, graph showing the histogram of the counting and current as a function of the time, or the electrical signal observed on the oscilloscope, can be broadcasted trough internet. By interacting through the video conference, the remote classroom is able to ask for changes in the reactor power or settings of the detection systems. They can also ask for the broadcast of some particular information. At the guest institution, the information is displayed in two parts or screens, as shown in the Figure 3. Concerning the interaction with - and the feedback from - the remote classroom, the camera of the video system in the remote classroom is used to ensure the contact between the trainees and the lecturer and reactor operators. Thus, the Internet Reactor Laboratory is complementary to the on reactor training courses. It allows distant learning, reducing the overall cost of the course when this is necessary. It can efficiently be used for the development of the human resources needed by the nuclear industry and the nuclear programs in countries without research reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Off-the-Shelf Technologies for Spacecraft Cabin Atmospheric Major Constituent Monitoring

Monitoring the atmospheric composition of a crewed spacecraft cabin is central to successfully expanding the breadth and depth of first-hand human knowledge and understanding of space. Highly reliable technologies must be identified and developed to monitor atmospheric composition. This will enable crewed space missions that last weeks, months, and eventually years. Atmospheric composition monitoring is a primary component of any environmental control and life support system. Instrumentation employed to monitor atmospheric composition must be inexpensive, simple, and lightweight and provide robust performance. Such a system will ensure an environment that promotes human safety and health, and that the environment can be maintained with a high degree of confidence. Key to this confidence is the capability for any technology to operate autonomously, with little intervention from the crew or mission control personnel. A study has been conducted using technologies that, with further development, may reach these goals.

Tatara, J. D.↗

Fault-Tolerant, Multiple-Zone Temperature Control

A computer program has been written as an essential part of an electronic temperature control system for a spaceborne instrument that contains several zones. The system was developed because the temperature and the rate of change of temperature in each zone are required to be maintained to within limits that amount to degrees of precision thought to be unattainable by use of simple bimetallic thermostats. The software collects temperature readings from six platinum resistance thermometers, calculates temperature errors from the readings, and implements a proportional + integral + derivative (PID) control algorithm that adjusts heater power levels. The software accepts, via a serial port, commands to change its operational parameters. The software attempts to detect and mitigate a host of potential faults. It is robust to many kinds of faults in that it can maintain PID control in the presence of those faults.

Granger, James↗

Automating Bug Report Classification with Few Shot Learning

Orthogonal defect classification (ODC) is a method used to categorize software defects, providing valuable insights into the development process. This study focuses on automating the classification of software bug reports into different ODC defect types using few shot learning, a machine learning approach that requires minimal labeled data. Previous research has manually classified bug reports or used traditional machine learning algorithms like linear support vector machine, achieving limited success. Our approach uses few shot learning to improve classification accuracy and efficiency. The results show a harmonic mean of recall and precision (i.e., the F1 score) of around 0.6 which is a performance improvement over previous methods. The results highlight the potential benefit of few shot learning techniques and their application in enhancing the safety and reliability of nuclear digital instrumentation and control (DI&C) systems. Future work will explore incorporating advanced techniques to supplement the model's training data and achieve better results.

42 - ENGINEERING↗

Cybersecurity for Electric Vehicle Fast-Charging Infrastructure

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

47 OTHER INSTRUMENTATION↗

Safety Assurance Framework for Nuclear Digital Instrumentation and Control Software

Software in digital instrumentation and control (D&C) systems poses unique challenges for the safety assurance of nuclear power plants. Through a literature survey of 21 sources, we analyzed various claims, arguments, and evidence used in safety assurance cases across industries. These were organized into a Goal Structuring Notation (GSN) safety assurance case framework to organize and visualize the various arguments for DI&C safety. We developed a classification for the levels of the framework, which can be used in other safety assurance cases to improve clarity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Science objectives lead to contamination requirements for the Cosmic Background Explorer (COBE)

The mission aims and related requirements of the Cosmic Background Explorer (COBE) are described in order to assess the measure needed for adequate control of optical system contamination. Instrument requirements are set forth so that the Diffuse IR Background Experiment (DIRBE), the Far IR Absolute Spectrophotometer (FIRAS), and the Differential Microwave Radiometers (DMRs) can achieve performance goals. The BRDF requirement for the primary mirror of the DIRBE is a maximum change of 50 percent on clean versus contaminated mirrors. The most critical components of the FIRAS and the DMR are discussed which are the sky horn and the antennae throats, respectively. The contamination-control devices include contamination covers, cleanroom assembly, and retractable cover assembly. The COBE is not found to perform unreliably due to contamination problems which suggests that the contamination program is effective.

Abrams, Eve M.↗

Development progress of the Materials Analysis and Particle Probe

The Materials Analysis and Particle Probe (MAPP) is a compact in vacuo surface science diagnostic, designed to provide in situ surface characterization of plasma facing components in a tokamak environment. MAPP has been implemented for operation on the Lithium Tokamak Experiment at Princeton Plasma Physics Laboratory (PPPL), where all control and analysis systems are currently under development for full remote operation. Control systems include vacuum management, instrument power, and translational/rotational probe drive. Analysis systems include onboard Langmuir probes and all components required for x-ray photoelectron spectroscopy, low-energy ion scattering spectroscopy, direct recoil spectroscopy, and thermal desorption spectroscopy surface analysis techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗