Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Optical Breath Gas Extravehicular Activity Sensor for the Advanced Portable Life Support System

The infrared gas transducer used during extravehicular activity (EVA) in the extravehicular mobility unit (EMU) measures and reports the concentration of carbon dioxide (CO2) in the ventilation loop. It is nearing its end of life and there are a limited number remaining. Meanwhile, the next generation advanced portable life support system (PLSS) now being developed requires CO2 sensing technology with performance beyond that presently in use. A laser diode (LD) spectrometer based on wavelength modulation spectroscopy (WMS) is being developed to address both applications by Vista Photonics, Inc. Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. Version 1.0 devices were delivered to NASA Johnson Space Center (JSC) in 2011. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement. The prototypes are controlled digitally with a field-programmable gate array (FPGA)/microcontroller architecture. Version 2.0 devices with improved electronics and significantly reduced wetted volumes were delivered to JSC in 2012. A version 2.5 upgrade recently implemented wavelength stabilized operation, better humidity measurement, and much faster data analysis/reporting. A wholly reconfigured version 3.0 will maintain the demonstrated performance of earlier versions while being backwards compatible with the EMU and offering a radiation tolerant architecture.

Wood, William R.↗

Infrared heterodyne spectroscopy of atmospheric ozone

The absorption spectrum of atmospheric ozone is measured within a 1/cm region at 1100/cm, using an IR heterodyne detector (spectrometer with CO2 local oscillator) developed for astronomical work. Absorption spectra obtained by passing radiation from the tunable diode laser through an absorption cell, heterodyne spectra of atmospheric ozone, and a predicted atmospheric spectrum are compared. Water vapor absorbing in the region of interest (1100/cm) is also considered. Preliminary results encourage the use of diode laser local oscillators in tunable heterodyne detector systems for spectroscopy of atmospheric ozone and remote high-resolution spectroscopy of atmospheric constituents and pollutants.

Frerking, M. A.↗

Tunable diode laser heterodyne spectrometer for remote observations near 8 microns

Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.

Glenar, D. A.↗

Optical Breath Gas Extravehicular Activity Sensor for the Advanced Portable Life Support System

The function of the infrared gas transducer used during extravehicular activity (EVA) in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation portable life support system (PLSS) requires highly accurate CO2 sensing technology with performance beyond that presently in use on the International Space Station extravehicular mobility unit (EMU). Further, that accuracy needs to be provided over the full operating pressure range of the suit (3 to 25 psia). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode (LD) sensor based on infrared absorption spectroscopy is being developed for this purpose by Vista Photonics, Inc. Version 1.0 prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The prototypes were upgraded with more sophisticated communications and faster response times to version 2.0 and delivered to JSC in July 2012. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement. The prototypes are controlled digitally with an field-programmable gate array microcontroller architecture. Based on the results of the iterative instrument development, further prototype development and testing of instruments were performed leveraging the lessons learned where feasible. The present development extends and upgrades the earlier hardware for the advanced PLSS 2.5 prototypes for testing at JSC. The prototypes provide significantly enhanced accuracy for water vapor measurement and eliminate wavelength drift affecting the earlier versions. Various improvements to the electronics and gas sampling are currently being advanced including the companion development of engineering development units that will ultimately be capable of radiation tolerance. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU.

Wood, William R.↗

Application of Tunable Diode Laser Spectrometry for Isotopic Analysis

Lead-salt tunable diode lasers are now commercially available with operating temperatures above 77 K and excellent single-mode characteristics which make them very useful for spectroscopy in the mid-IR spectral range. Using these lasers for absorption measurements in the 4.3 micrometer spectral region we have made accurate measurements of isotopic abundances in CO2. The method involves assembly language controlled data acquisition of spectra of selected adjacent isotopic rotational lines, an etalon spectral frequency calibration technique, the fitting of multiple Voigt profiles to the data, and the ratioing of absorbances from simultaneously acquired sample and reference data scans. The accuracy achieved is better than 0.4% for the C-13/C-12 ratio and 1% for the O-18/O-16 ratio. Higher accuracy is expected from improvements now being implemented.

Sauke, T. B.↗

Photoacoustic measurement of differential broadening of the Lambda doublets in NO(X 2Pi 1/2,v = 2-0) by Ar

A differential broadening of the Lambda doublets in the v = 2-0 overtone band of the 2pi1/2 ground electronic state of NO in an Ar buffer gas has been observed by photoacoustic spectroscopy using a tunable color-center laser. The broadening coefficients for the f symmetry components are larger than for the e symmetry components by up to about 6 percent for J of about 16.5. This differential depends on J and vanishes at low J, implicating the anisotropy of the unpaired electron Pi orbital in the plane of rotation. The 2Pi3/2 transitions are slightly broader than the 2Pi1/2 as a result of spin-flipping collisional relaxation. The observed line shapes also exhibit collisional or Dicke narrowing due to velocity-changing collisions.

Pine, A. S.↗

Non-Invasive Health Diagnostics using Eye as a 'Window to the Body'

As a 'window to the body', the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and help develop preventative/therapeutic countermeasures early. The effects of space travel on human body are similar to those of normal aging. For example, radiation exposure in space could lead to formation of cataracts and cancer by damaging the DNA and causing gene mutation. Additionally, the zero-gravity environment causes fluid shifts in the upper extremities of the body and changes the way blood flows and organ system performs. Here on Earth, cataract, age-related macular degeneration (AMD), diabetic retinopathy (DR), and glaucoma are major eye diseases and are expected to double in next two decades. To detect, prevent, and treat untoward effects of prolonged space travel in real-time requires the development of non-invasive diagnostic technologies that are compact and powerful. We are developing fiber-optic sensors to evaluate the ocular tissues in health, aging, and disease employing the techniques of dynamic light scattering (cataract, uveitis, Alzheimer's, glaucoma, DR, radiation damage, refractive surgery outcomes), auto-fluorescence (aging, DR), laser-Doppler flowmetry (choroidal blood flow), Raman spectroscopy (AMD), polarimetry (diabetes), and retinal oximetry (occult blood loss). The non-invasive feature of these technologies integrated in a head-mounted/goggles-like device permits frequent repetition of tests, enabling evaluation of the results to therapy that may ultimately be useful in various telemedicine applications on Earth and in space.

Ansari, Rafat R.↗

Argus: a new instrument for the measurement of the stratospheric dynamical tracers, N2O and CH4

We describe here a new instrument for the simultaneous, in situ measurement of the stratospheric tracer molecules, nitrous oxide (N2O) and methane (CH4). Argus is unique in its small size making it well suited for limited payload atmospheric research platforms. Argus employs second harmonic spectroscopy using tunable lead-salt diode lasers emitting in the mid-infrared. We first explain the Argus design philosophy followed by detailed descriptions of the instrument's optical, mechanical, and thermal sub-systems. Argus employs an in-flight calibration system providing real time calibrations and tightly constrained uncertainty estimates of the returned data. Data analysis is carried out using non-linear least-squares model fits to the acquired second harmonic spectra. A sampling of Argus data acquired on a recent stratospheric research campaign in the Arctic winter is presented.

Methane/analysis↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

NASA's Turbulent Heat Flux (THX) task under the Transformational Tools & Technologies project is focused on acquiring benchmark temperature and velocity data in turbulent shear layers for validation of computational fluid dynamics (CFD) codes. Standard CFD turbulence models lack the ability to accurately calculate a number of fundamental flow phenomena, including the turbulent transport of heat. In nearly all production class Reynolds-averaged Navier-Stokes (RANS) CFD codes, a gradient-diffusion approximation is used whereby a constant turbulent Prantdl number, Prt, is used to relate an eddy viscosity calculated for the momentum terms, to the turbulent heat flux terms. The default in most CFD codes is Prt = 0.9, however this is not representative of all flows. As discussed in Yoder et al. (2015) and Reynolds (1974), Prt = 0.7 is felt to be more appropriate for jets. Recent work, as discussed in Yoder (2016a), has explored more complex formulations including variable turbulent Prantdl number models. PARTICLE IMAGE VELOCIMETRY; TEMPERATURE MEASURING INSTRUMENTS; FILM COOLING; HIGH TEMPERATURE GASES; COMPUTATIONAL FLUID DYNAMICS; PREDICTION ANALYSIS TECHNIQUES; TURBULENCE MODELS; RAMAN SPECTRA; VELOCITY; MACH NUMBER; GAS TURBINE ENGINES; NOZZLE FLOW; THERMOCOUPLES; LASER INDUCED FLUORESCENCE; COOLING FLOWS (ASTROPHYSICS); RAMAN SPECTROSCOPY; HEAT FLUX

Wernet, Mark P.↗

Infrared heterodyne spectroscopy for astronomical purposes

Heterodyne infrared astronomy was carried out using CO2 lasers and some solid state tunable lasers. The best available detectors are mercury cadmium telluride photodiodes. Their quantum efficiencies reach values near 0.5 and in an overall system an effective quantum efficiency, taking into account optical losses and amplifier noise, of about 0.25 was demonstrated. Initial uses of 10 micron heterodyne spectroscopy were for the study of planetary molecular spectra.

Townes, C. H.↗

Microwave tunable laser source: A stable, precision tunable heterodyne local oscillator

The development and capabilities of a tunable laser source utilizing a wideband electro-optic modulator and a CO2 laser are described. The precision tunability and high stability of the device are demonstrated with examples of laboratory spectroscopy. Heterodyne measurements are also presented to demonstrate the performance of the laser source as a heterodyne local oscillator. With the use of five CO2 isotope lasers and the 8 to 18 GHz sideband offset tunability of the modulator, calculations indicate that 50 percent spectral coverage in the 9 to 12 micron region is achievable. The wavelength accuracy and stability of this laser source is limited by the CO2 laser and is more than adequate for the measurement of narrow Doppler-broadened line profiles. The room-temperature operating capability and the programmability of the microwave tunable laser source are attractive features for its in-the-field implementation. Although heterodyne measurements indicated some S/N degradation when using the device as a local oscillator, there does not appear to be any fundamental limitation to the heterodyne efficiency of this laser source. Through the use of a lower noise-figure traveling wave tube amplifier and optical matching of the output beam with the photomixer, a substantial increase in the heterodyne S/N is expected.

Sachse, G. W.↗

Dielectric Fabry-Perot mirror coatings for infrared astronomy

A number of Fabry-Perot (FP) coating designs have been developed specifically for IR astronomy. These have been optimized for uniform reflectance over five contiguous spectral ranges of particular astronomical interest between 1 and 5 microns. Wavelength coverage in individual designs is given by (maximum wavelength/minimum wavelength) greater than 1.4, over which reflective finesse is maintained near 35. Consideration has been made for the peculiar requirements of FP coatings. Visual alignment and testing of the FP has been made convenient by bringing the reflective finesse of the coating at 632.8 nm to the same value as the main IR reflection band. For example, a calcium fluoride FP can be aligned and tested at 632.8-nm He-Ne laser line, with the assurance of a corresponding finesse and spectral resolving power over its IR (3.6-5.1-micron) range. In addition, the FP can be used for IR spectroscopy while being simultaneously monitored and/or actively controlled at the laser wavelength. The potential for the coating itself to degrade the effective surface flatness of the FP through either mechanical stress or thickness nonuniformities is minimized by reducing to a minimum the number and thickness of coating layers. Several of these coatings have been fabricated and are actively in use at a number of observatories.

Trauger, J.↗

A parametric study of single-wall carbon nanotube growth by laser ablation

Results of a parametric study of carbon nanotube production by the double-pulse laser oven process are presented. The effect of various operating parameters on the production of single-wall carbon nanotubes (SWCNTs) is estimated by characterizing the nanotube material using analytical techniques, including scanning electron microscopy, transmission electron microscopy, thermo gravimetric analysis and Raman spectroscopy. The study included changing the sequence of the laser pulses, laser energy, pulse separation, type of buffer gas used, operating pressure, flow rate, inner tube diameter, as well as its material, and oven temperature. It was found that the material quality and quantity improve with deviation from normal operation parameters such as laser energy density higher than 1.5 J/cm2, pressure lower than 67 kPa, and flow rates higher than 100 sccm. Use of helium produced mainly small diameter tubes and a lower yield. The diameter of SWCNTs decreases with decreasing oven temperature and lower flow rates.

Nanotubes, Carbon/chemistry↗

Numerical study of low-current steady arcs

The development of a high-efficiency CW YLF laser doped with Er,Tm,Ho: and featuring a strongly focusing resonator that collects a high density of pump power on the active crystal is described. The emission is investigated at 2.06 microns and a tuning range both at liquid-nitrogen (77 K) and at dry-ice (210 K) temperature. The noise characteristics and the long-term power stability of the laser is studied with an eye to employing this source for high-resolution spectroscopy in the 2-micron wavelength region. The detection of several absorption lines of NH3 at low pressure is described. The output power of the laser as a function of the power impinging on the crystal for different transmission of the output mirror is illustrated. The best result obtained is 1.46 W output for 3.2 W of argon pump. The minimum threshold achieved is 3.5 mW with a 1-percent transmission mirror. It is concluded that it is possible to develop a highly efficient Ho:YLF laser featuring low noise and sufficient tunability for high-resolution spectroscopy in the 2-micron region.

Kim, S. C.↗

Waveguiding and Dispersion Properties of Interband Cascade Laser Frequency Combs

Mid-infrared semiconductor lasers have emerged as indispensable compact coherent sources for military and commercial applications. While much of the historical emphasis has been on maximizing the output power and/or spectral purity, a recent new focus has been on engineering these lasers to operate as optical frequency combs (OFCs) for broadband real-time spectroscopy. In particular, the combination of low-drive-power and broad gain bandwidth has made interband cascade laser (ICL) OFCs an attractive complement to quantum cascade laser OFCs operating at longer wavelengths. Moreover, ICL combs can potentially be incorporated into fully-integrated dual-comb spectrometers that employ fast, room-temperature IC photodetectors processed on the same chip.However, the high refractive index of the ICL’s GaSb substrate poses some challenges to the optical waveguiding. Because the modal index is considerably lower than that of the substrate, the optical field can penetrate the bottom cladding layer and leak into the GaSb, inducing wavelength-dependent interference that modifies the gain and group velocity dispersion (GVD) profiles. Even when the effect on lasing threshold is small, the comb properties can be adversely affected. Using the sub-threshold Fourier transform technique, we studied ICL combs with various ridge widths, substrate thicknesses, and center wavelengths. This allowed us to evaluate the effects of modal leakage on the GVD. We find that the resonant nature of the substrate modes induces oscillations, which affect both the spectral bandwidth and the phase-locking properties above threshold. Strategies to mitigate the GVD’s undesired and unpredictable spectral variation will be presented.

Meyer, J. R↗

Peripherally hydrogenated neutral polycyclic aromatic hydrocarbons as carriers of the 3 micron interstellar infrared emission complex: results from single-photon infrared emission spectroscopy

Infrared emission spectra of five gas-phase UV laser-excited polycyclic aromatic hydrocarbons (PAHs) containing aliphatic hydrogens are compared with the main 3.3 microns and associated interstellar unidentified infrared emission bands (UIRs). We show that neutral PAHs can account for the majority of the 3 microns emission complex while making little contribution to the other UIR bands; peripherally hydrogenated PAHs produce a better match to astrophysical data than do those containing methyl side groups; 3.4 microns plateau emission is shown to be a general spectral feature of vibrationally excited PAHs containing aliphatic hydrogens, especially those containing methyl groups; and finally, hot-band and overtone emissions arising from aromatic C-H vibrations are not observed in laboratory emission spectra, and therefore, in contrast to current assignments, are not expected to be observed in the UIRs.

NASA Discipline Exobiology↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗

Optical signatures of molecular particles via mass-selected cluster spectroscopy

A new molecular beam apparatus was developed to study optical absorption in cold (less than 100 K) atomic clusters and complexes produced by their condensation with simple molecular gases. In this instrument, ionized clusters produced in a laser vaporization nozzle source are mass selected and studied with photodissociation spectroscopy at visible and ultraviolet wavelengths. This new approach can be applied to synthesize and characterize numerous particulates and weakly bound complexes expected in planetary atmospheres and in comets.

Duncan, Michael A.↗