Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Global Test Range: Toward Airborne Sensor Webs

This viewgraph presentation reviews the planned global sensor network that will monitor the Earth's climate, and resources using airborne sensor systems. The vision is an intelligent, affordable Earth Observation System. Global Test Range is a lab developing trustworthy services for airborne instruments - a specialized Internet Service Provider. There is discussion of several current and planned missions.

Mace, Thomas H.↗

Update on the NASA Glenn Propulsion Systems Lab Ice Crystal Cloud Characterization (2015, 2016)

NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, was outfitted with a spray system to generate ice crystals in 2011. Turbine engines and driven rigs can experience ice crystal icing at flight altitudes, temperatures and Mach numbers. To support these tests, four ice crystal characterizations have been conducted in two different facility configurations. In addition, super-cooled liquid and mixed phase clouds have also been generated. This paper represents a work in progress. It will describe some of the 11-parameter calibration space, and how those parameters interact with each other, the instrumentation used to characterize the cloud and present a sample of the cloud characterization results.

Engine Icing↗

Update on the NASA Glenn Propulsion Systems Lab Icing and Ice Crystal Cloud Characterization (2017)

NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, generates icing clouds with a spray system. While the spray system is used mostly to create ice crystal clouds (Appendix D/P), the 2017 cloud characterization effort added the requirement to produce exactly supercooled liquid clouds in Appendix C and Appendix O. Success was demonstrated to supercool the largest drops at the warmest conditions, but not freeze out the smallest drops at the coldest conditions. This paper documents primarily the total water content characterization methodology and results from an Iso-Kinetic Probe in ice crystals and Multi-Wire sensor in supercooled liquid, along with the cloud uniformity provided by light extinction tomography. Particle size distribution results from High Speed Imaging probes and a Phase Doppler Interferometer are discussed. Also, a new numerical model for tracking the thermodynamics of the air-drop interactions in PSL from the plenum toward the cloud characterization plane are noted. Both of these latter topic are more fully documented in companion papers.

Calibration↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called WiSe Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring

Wireless Sensor Network↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called Wi-Se Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring.

Wireless Sensor Network↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called WiSe Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring.

Wireless Sensor Network↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

Background: As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab at NASA Johnson Space Center (JSC), aims to address this challenge through innovative approaches. Objective: Development and evaluation of a NGED system, focusing on its adaptability to various Moon to Mars mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). To help inform vehicle and system requirements, an exercise volumetric assessment was performed via data collection and biomechanical modeling.

C Wang↗

BACKFLIP Project: Determination of BACKsheet Material Properties: A Comparison of Market-Benchmark Technologies to Novel Non-Fluoro-Based Co-Extruded Backsheet Materials and Their Correlation and Impact on PV Module Degradation Rates

Quantifying degradation rate of backsheets will help procuring materials for 30+ years. Today most backsheets on the market have a laminated PET core; polyolefin materials may provide better properties for backsheets (barrier to water, mechanical properties through UV and hydrolytic environments, etc.). End-of-life regulations may require fluorine-free backsheet products in future global markets. Parametrized equation predicting the service life of backsheets, and validated by both lab and outdoor extensive testing. Technical and commercial confidence to the entire value chain: from backsheet and module manufacturers to the downstream community (IPP, banks, developers) that materials of higher quality can help reduce finance costs, therefore driving down LCOE. A fast track PV module market adaptation for novel high-quality materials, such as co-extruded polyolefin-core backsheets, by obtaining unbiased durability data.

14 SOLAR ENERGY↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗

Building Blocks for Secure and Prosperous Defense Critical Supply Chains: A Case Study from Microelectronics

Securing defense-critical supply chains, built on resilient and sustainable microelectronics fabrication and deployment, is a national imperative and one that requires an investment in basic and applied research, development, and deployment into industries in (and out of) the Defense Industrial Base (DIB). Critical next steps include the development of pilots for revolutionary concepts in a new formal verification model and the Cyber-Physical Passport (CPP) concept for chain of custody. Critical infrastructure leadership should take action with a sense of urgency. Working in conjunction with the Under Secretary for Acquisition and Sustainment, the Assistant Secretary of Defense for Research and Engineering should establish pilot programs with the Defense Advanced Research Projects Agency and the service labs to build and test both concepts in legacy and new system development.. Additionally, the Pentagon may be aware that an existing Manufacturing Innovation Institute is piloting, with the semiconductor industry, cyber innovations to provide verifiable security properties and guarantees of physical functions to build a more cyber secure, resilient and efficient micro-electronics supply chain.

99 GENERAL AND MISCELLANEOUS↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. An example method for operating an integrated thermal cycling system includes depositing samples into the integrated thermal cycling system that includes a thermal cycling device and an electronic interface. The thermal cycling device includes multiple wells to receive the samples to be thermally cycled, a thermoelectric cooling (TEC) element connected to the multiple wells, a substrate on which the TEC element is positioned, and a controller coupled to the TEC element. The multiple wells are positioned within the substrate that includes a thermally conductive ground positioned between adjacent wells. Supplying power to the integrated thermal cycling system, via the electronic interface, allows the multiple wells to exchange heat with the substrate and for each well to operate independently from other wells.

Beer, N. Reginald↗

Mechanical Properties of Permanent Foaming Fixatives for Deactivation and Decommissioning Activities

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk, Contaminate the public and environment, Drive up operational costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated in collaboration with Savannah River National Lab (SRNL). Mechanical property testing will dictate how well PU foams can withstand physical stressors outlined in safety documents while immobilizing residual contamination. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Polyurethanes consists of repeating units of urethanes which are produced from an exothermic reaction between a polyol (an alcohol with two or more hydroxyl groups in a molecule) and an isocyanate [2]. PUs consists of 3D cells that are formed by a blowing agent which is normally water. Water interacting with the isocyanate creates carbon dioxide and urea which contributes to cells' growth and expansion. The cross-linking between the polyol and isocyanate solidify the cell faces and walls. Micro scale properties that can influence mechanical properties include: Relative density (ratio between density of cellular material and density of the solid of which the cell walls are made of). Cells connectivity between edges and faces, and number of cells contact neighbors [3]. Whether a foam is open-celled or closed-celled. Closed-celled foams have a thin membrane that encloses each cell which can contribute to the stiffness of the foam. Incorporating fillers in the PU matrix like carbon-based nanoparticles in the form of expandable graphite (EG) can increase the thermal and mechanical performance [4]. When exposed to heat, EG produces a char layer that prevents heat and oxygen transfer which is known as intumescing. Mechanical performance is dependent on amount of EG loading since the cell sizes are linearly dependent on it. Overall, the rigid foams (I-R2) proved superior. SEM Analysis: I-R2 had the most consistent spherical sizes (average cell diameter: 489 μm), which enhance the relative density the most [5]. Tensile Testing Results: I-R2 experienced the largest breaking load (103.65 lbf) and stress (289.42 psi). I-R2 also had a higher Young's Modulus compared to R1 (2.99 ksi to 2.09 ksi). Compression Testing Results: I-R2 had the highest stress at 80% deflection (360.67 psi), load (1387.48 lbf) and modulus (3.92 ksi)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Speciation via Diffusive Gradients Thin-Films Technology

Objectives: Develop and test various diffusive gradient in thin films (DGT) samplers for mercury - SRNL is developing reactive DGTS (rDGTs). Test chemistry to differentiate methylmercury from total and/or inorganic mercury in environmental samples. Fabricate and test rDGT samplers for deployment. Deploy the rDGTs in variable settings. Mercury is a persistent-bioaccumulative-toxic environmental pollutant. Mercury exists in different species such as elemental, inorganic, and methyl. Mercury speciation determine mercury behavior and toxicity. For example, methylmercury strongly accumulates in biota such as fish resulting in potential human health impacts. DGTs are innovative samplers to measure water concentration by diffusion and capture. Types of Hg DGTs used: Total Hg, Inorganic Hg, and Methyl Hg. Deployment Sites: Upper Three Runs, Lower Three Runs, Steele Creek, East Fork Poplar Creek (SRNL Sites), Horizons Creek, NOA Creek, Bruners Creek (ORNL Sites). DGT concentration estimates closely matched alternative measurements for soluble mercury at each Oak Ridge site - DGTs did not respond to particulate mercury. DGTs provide a representative measure for biota uptake since they are left out longer which allows for an average exposure concentration. DMA-80 provided an efficient and quick analysis. Variability in site location made a difference in Hg species. DGT preparations and sampling wasn't as quick and simple as microcolumn technology. Copper reagent degraded agarose gel - more work and cleaner data are needed to assess speciation in rDGTs. Future Work: Use cross-linked polyacrylamide for the collection layer for a stronger plastic. Make a copper diffusion layer without agarose. Test copper separation in lab using realistic stream conditions such as high organic carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Exploration of UAV Flights Recorded on Smartphones

The increasing accessibility and technological advancements of unmanned aerial vehicles (UAVs) pose legitimate concerns to nuclear non-proliferation efforts. To deter and combat unwanted or nefarious UAV activity near or around nuclear sensitive sites, the ability to quickly and easily detect drones becomes vital. Our team is exploring the use of ubiquitous smartphones as multi-modal sensors (microphone, accelerometer, gyroscope, etc.) to meet this challenge. In conjunction with Idaho National Lab, two UAV flight tests and one stationary in-air test were conducted and recorded with eight Samsung Galaxy S8 smartphones. This work presents initial characterization and annotation of acoustic signals associated with UAV activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SULI End of Summer Presentation

This presentation made on Power Point is a brief summary of my work enhancing the Supervisory Control and Data Acquisition (SCADA) architecture for Idaho National Lab’s Critical Infrastructure Test Range Complex (CITRC). This work was part of an on-going project to create a digital twin of CITRC that will be implemented for resiliency research. Resiliency is growing more important as extreme weather, aging infrastructure, and increasing load all exert stress on the United States power grid. This presentation highlights how I documented the existing devices and data flow on site and then updated specific device settings to better support the needs of the project. It also examines future use of this data in the digital twin data warehouse (DeepLynx), and future Artificial Intelligence and Advanced Distribution Management System applications. It will be presented to the B751 Water and Energy Systems Analysis group at INL during my last week.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Liquid Metal Intrusion Testing Final Report

Los Alamos National Lab (LANL) is concerned about potential interactions between a tin-antimony pewter material used for localized radiation shielding and stainless-steel containers used for storage and movement of radioactive materials when containers are subjected to elevated temperatures. The specific concern is whether pewter constituents can diffuse into grain boundaries and lead to embrittlement of the stainless steel, potentially compromising the ability of stainless steel components to maintain containment. This work will provide a qualitative and quantitative understanding of the depth of penetration of the pewter coating constituents into stainless steel when the test coupons are subjected to a range of thermal environments. The results of the present work will allow LANL to determine conditions for safely using the pewter lined containers.

36 MATERIALS SCIENCE↗

Scale-Up and Modeling Efforts Using an Omniphobic Surface Treatment for Mitigating Solids Deposition

Abstract Gas hydrates, waxes and asphaltenes represent some of the most significant flow assurance challenges, especially in subsea lines, where treatment options can be limited. Currently, complete avoidance is the primary strategy for hydrate management, while chemical or mechanical flushing/pigging may be utilized for other solids. Each system must also be treated with individualized solutions, as there have been no proved one-size-fits-all technologies demonstrated to date. As an alternative to constant chemical injection or thermodynamic controls such as insulation or heating, a robust omniphobic surface treatment material has been developed which has been shown in previous studies to significantly reduce the adhesion of flow assurance solids, resulting in lower risk for deposition and plugging of gas hydrates, waxes, and asphaltenes. As part of a Department of Energy study, laboratory scale tests were performed on a variety of apparatuses ranging from micromechanical force (micron scale) to laboratory flow loop testing (meter scale). While the results from these tests have been promising, there can be some disconnects between lab-scale observations and field-scale testing. Several factors can result in discrepancies between small-scale bench-top studies and deployment-scale efforts. These include flow conditions (Reynolds number, flow regime), chemistry (synthetic vs. crude oils, gas composition, and additives), physical differences (pipeline material, size, and geometry), etc. This work will describe the actions taken to better understand the deployment and performance of a material such as this omniphobic surface treatment in field scenarios, and to build confidence for deployment in a production scenario. These efforts include modeling field production scenarios using models developed from lab observations, application of the material to field-scale equipment to better understand application challenges, and expanded survivability and longevity testing. Understanding the bridge between laboratory testing and full-scale deployment allows for better technique and risk mitigation for field scale testing.

03 NATURAL GAS↗