Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear Regression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Respiration Induced Heart Motion and Indications of Gated Delivery for Left-Sided Breast Irradiation

Purpose: To investigate respiration-induced heart motion for left-sided breast irradiation using a four-dimensional computed tomography (4DCT) technique and to determine novel indications to assess heart motion and identify breast patients who may benefit from a gated treatment. Methods and Materials: Images of 4DCT acquired during free breathing for 20 left-sided breast cancer patients, who underwent whole breast irradiation with or without regional nodal irradiation, were analyzed retrospectively. Dose distributions were reconstructed in the phases of 0%, 20%, and 50%. The intrafractional heart displacement was measured in three selected transverse CT slices using D{sub LAD} (the distance from left ascending aorta to a fixed line [connecting middle point of sternum and the body] drawn on each slice) and maximum heart depth (MHD, the distance of the forefront of the heart to the line). Linear regression analysis was used to correlate these indices with mean heart dose and heart dose volume at different breathing phases. Results: Respiration-induced heart displacement resulted in observable variations in dose delivered to the heart. During a normal free-breathing cycle, heart-induced motion D{sub LAD} and MHD changed up to 9 and 11 mm respectively, resulting in up to 38% and 39% increases of mean doses and V{sub 25.2} for the heart. MHD and D{sub LAD} were positively correlated with mean heart dose and heart dose volume. Respiratory-adapted gated treatment may better spare heart and ipsilateral-lung compared with the conventional non-gated plan in a subset of patients with large D{sub LAD} or MHD variations. Conclusion: Proposed indices offer novel assessment of heart displacement based on 4DCT images. MHD and D{sub LAD} can be used independently or jointly as selection criteria for respiratory gating procedure before treatment planning. Patients with great intrafractional MHD variations or tumor(s) close to the diaphragm may particularly benefit from the gated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Life in Patients With Brain Metastases Using the EORTC QLQ-BN20+2 and QLQ-C15-PAL

Purpose: The 20-item European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire-Brain Neoplasm (QLQ-BN20) is a validated quality-of-life (QOL) questionnaire for patients with primary brain tumors. The European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire-Core 15 Palliative (QLQ-C15-PAL) core palliative questionnaire is a 15-item version of the core 30-item QLQ-C30 and was developed to decrease the burden on patients with advanced cancer. The combination of the QLQ-BN20 and QLQ-C30 to assess QOL may be too burdensome for patients. The primary aim of this study was to assess QOL in patients before and after treatment for brain metastases using the QLQ-BN20+2 and QLQ-C15-PAL, a version of the QLQ-BN20 questionnaire with 2 additional questions assessing cognitive functioning that were not addressed in the QLQ-C15-PAL. Methods and Materials: Patients with brain metastases completed the QLQ-C15-PAL and QLQ-BN20+2 questionnaires to assess QOL before and 1 month after radiation. Linear regression analysis was used to assess changes in QOL scores over time, as well as to explore associations between the QLQ-BN20+2 and QLQ-C15-PAL scales, patient demographics, and clinical variables. Spearman correlation assessed associations between the QLQ-BN20+2 and QLQ-C15-PAL scales. Results: Among 108 patients, the majority (55%) received whole-brain radiotherapy only, with 65% of patients completing follow-up at 1 month after treatment. The most prominent symptoms at baseline were future uncertainty (QLQ-BN20+2) and fatigue (QLQ-C15-PAL). After treatment, significant improvement was seen for the QLQ-C15-PAL insomnia scale, as well as the QLQ-BN20+2 scales of future uncertainty, visual disorder, and concentration difficulty. Baseline Karnofsky Performance Status was negatively correlated to QLQ-BN20+2 motor dysfunction but positively related to QLQ-C15-PAL physical functioning and QLQ-BN20+2 cognitive functioning at baseline and follow-up. QLQ-BN20+2 scales of future uncertainty and motor dysfunction correlated with the most QLQ-C15-PAL scales, including overall QOL (negative association) at baseline and follow-up. Conclusion: After radiation, the questionnaires showed maintenance of QOL and improvement of QOL scores such as future uncertainty, which featured prominently in this patient population. It is proposed that the 37-item QLQ-BN20+2 and QLQ-C15-PAL, as opposed to the 50-item QLQ-BN20 and QLQ-C30, may be used together as a universal QOL assessment tool in this setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Increasing Experience on Dosimetric and Clinical Outcomes in the Management of Malignant Pleural Mesothelioma With Intensity-Modulated Radiation Therapy

Purpose: To assess the impact of increasing experience with intensity-modulated radiation therapy (IMRT) after extrapleural pneumonectomy (EPP) for malignant pleural mesothelioma (MPM). Methods and Materials: The records of all patients who received IMRT following EPP at Duke University Medical Center between 2005 and 2010 were reviewed. Target volumes included the preoperative extent of the pleural space, chest wall incisions, involved nodal stations, and a boost to close/positive surgical margins if applicable. Patients were typically treated with 9-11 beams with gantry angles, collimator rotations, and beam apertures manually fixed to avoid the contalateral lung and to optimize target coverage. Toxicity was graded retrospectively using National Cancer Institute common toxicity criteria version 4.0. Target coverage and contralateral lung irradiation were evaluated over time by using linear regression. Local control, disease-free survival, and overall survival rates were estimated using the Kaplan-Meier method. Results: Thirty patients received IMRT following EPP; 21 patients also received systemic chemotherapy. Median follow-up was 15 months. The median dose prescribed to the entire ipsilateral hemithorax was 45 Gy (range, 40-50.4 Gy) with a boost of 8-25 Gy in 9 patients. Median survival was 23.2 months. Two-year local control, disease-free survival, and overall survival rates were 47%, 34%, and 50%, respectively. Increasing experience planning MPM cases was associated with improved coverage of planning target volumes (P=.04). Similarly, mean lung dose (P<.01) and lung V5 (volume receiving 5 Gy or more; P<.01) values decreased with increasing experience. Lung toxicity developed after IMRT in 4 (13%) patients at a median of 2.2 months after RT (three grade 3-4 and one grade 5). Lung toxicity developed in 4 of the initial 15 patients vs none of the last 15 patients treated. Conclusions: With increasing experience, target volume coverage improved and dose to the contralateral lung decreased. Rates of pulmonary toxicity were relatively low. However, both local and distant control rates remained suboptimal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Tumor Shape Variability in Head-and-Neck Cancer Patients Over the Course of Radiation Therapy Using Implanted Gold Markers

Purpose: This study quantifies tumor shape variability in head-and-neck cancer patients during radiation therapy using implanted markers. Methods and Materials: Twenty-seven patients with oropharyngeal tumors treated with (chemo)radiation were included. Helical gold markers (0.35 Multiplication-Sign 2 mm, 3-10/patient, average 6) were implanted around the tumor. Markers were identified on planning computed tomography (CT) and daily cone beam CT (CBCT). After bony anatomy registration, the daily vector length on CBCT in reference to the planning CT and daily marker movement perpendicular to the gross tumor volume (GTV) surface at planning CT (d{sub normal}) of each marker were analyzed. Time trends were assessed with linear regression of the {sub markers}. In 2 patients, 2 markers were implanted in normal tissue to evaluate migration by measuring intermarker distances. Results: Marker implantation was feasible without complications. Three-dimensional vectors (4827 measurements, mean 0.23 cm, interquartile ratio 0.24 cm) were highest in base of tongue sublocalization (P<.001) and bulky tumors (vectors exceeded 0.5 cm in 5.7% [0-20 mL], 12.0% [21-40 mL], and 21.7% [{>=}41 mL], respectively [P<.001] of measurements). The measured inward time trend in 11/27 patients correlated with the visual observed marker pattern. In patients with an outward trend (5/27) or no trend (11/27), visual observation showed predominantly an inhomogeneous pattern. Remarkably, in 6 patients, outward marker movement was observed in the posterior pharyngeal wall. The difference in distance between normal tissue markers (1 SD) was 0.05-0.06 cm without time trend, indicating that implanted markers did not migrate. Conclusions: During head-and-neck radiation therapy, normal tissue markers remained stable. Changes in position of tumor markers depended on sublocalization and tumor volume. Large differences in marker patterns between patients as well as within patients were observed. Based on our study, the cranial and caudal border in the posterior pharyngeal wall are at highest risk to be covered insufficiently. Furthermore, implanted markers could help identify patients with an actual shrinkage of the GTV who might benefit from mid-radiation therapy redelineation to reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging system concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Threshold Doses for Focal Liver Reaction After Stereotactic Ablative Body Radiation Therapy for Small Hepatocellular Carcinoma Depend on Liver Function: Evaluation on Magnetic Resonance Imaging With Gd-EOB-DTPA

Purpose: Focal liver reaction (FLR) appears on radiographic images after stereotactic ablative body radiation therapy (SABR) in patients with hepatocellular carcinoma (HCC) and chronic liver disease. We investigated the threshold dose (TD) of FLR and possible factors affecting the TD on gadoxetate acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). Methods and Materials: In 50 patients who were treated with SABR for small HCC and followed up by MRI for >6 months, FLR, seen as a hypointense area, was evaluated on the hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI. The follow-up MRI with the largest extent of FLR was fused to the planning computed tomography (CT) image, and patients with good image fusion concordance were eligible. After delineating the border of the FLR manually, a dose–volume histogram was used to identify the TD for the FLR. Clinical and volumetric factors were analyzed for correlation with the TD. Results: A total of 45 patients were eligible for analysis with a median image fusion concordance of 84.9% (range, 71.6-95.4%). The median duration between SABR and subsequent hepatobiliary phase MRI with the largest extent of FLR was 3 months (range, 1-6 months). The median TD for FLR was 28.0 Gy (range, 22.3-36.4 Gy). On univariate analysis, pre-treatment Child-Pugh (CP) score and platelet count were significantly correlated with the TD. On multiple linear regression analysis, CP score was the only parameter that predicted TD. Median TDs were 30.5 Gy (range, 26.2.3-36.4 Gy) and 25.2 Gy (range, 22.3-27.5 Gy) for patients with CP-A and CP-B disease, respectively. Conclusion: The TD was significantly correlated with baseline liver function. We propose 30 Gy for CP-A disease and 25 Gy for CP-B disease in 5 fractions as TDs for FLR after SABR for patients with HCC and chronic liver disease. Use of these TDs will help to predict potential loss of liver tissue after SABR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPECT Analysis of Cardiac Perfusion Changes After Whole-Breast/Chest Wall Radiation Therapy With or Without Active Breathing Coordinator: Results of a Randomized Phase 3 Trial

Purpose: Cardiac muscle perfusion, as determined by single-photon emission computed tomography (SPECT), decreases after breast and/or chest wall (BCW) irradiation. The active breathing coordinator (ABC) enables radiation delivery when the BCW is farther from the heart, thereby decreasing cardiac exposure. We hypothesized that ABC would prevent radiation-induced cardiac toxicity and conducted a randomized controlled trial evaluating myocardial perfusion changes after radiation for left-sided breast cancer with or without ABC. Methods and Materials: Stages I to III left breast cancer patients requiring adjuvant radiation therapy (XRT) were randomized to ABC or No-ABC. Myocardial perfusion was evaluated by SPECT scans (before and 6 months after BCW radiation) using 2 methods: (1) fully automated quantitative polar mapping; and (2) semiquantitative visual assessment. The left ventricle was divided into 20 segments for the polar map and 17 segments for the visual method. Segments were grouped by anatomical rings (apical, mid, basal) or by coronary artery distribution. For the visual method, 2 nuclear medicine physicians, blinded to treatment groups, scored each segment's perfusion. Scores were analyzed with nonparametric tests and linear regression. Results: Between 2006 and 2010, 57 patients were enrolled and 43 were available for analysis. The cohorts were well matched. The apical and left anterior descending coronary artery segments had significant decreases in perfusion on SPECT scans in both ABC and No-ABC cohorts. In unadjusted and adjusted analyses, controlling for pretreatment perfusion score, age, and chemotherapy, ABC was not significantly associated with prevention of perfusion deficits. Conclusions: In this randomized controlled trial, ABC does not appear to prevent radiation-induced cardiac perfusion deficits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Growth Rate Predicts Radiation Response in Vestibular Schwannomas

Purpose: Vestibular schwannomas (VS) are often followed without initial therapeutic intervention because many tumors do not grow and radiation therapy is associated with potential adverse effects. In an effort to determine whether maximizing initial surveillance predicts for later treatment response, the predictive value of preirradiation growth rate of VS on response to radiation therapy was assessed. Methods and Materials: Sixty-four patients with 65 VS were treated with single-fraction stereotactic radiation surgery or fractionated stereotactic radiation therapy. Pre- and postirradiation linear expansion rates were estimated using volumetric measurements on sequential magnetic resonance images (MRIs). In addition, postirradiation tumor volume change was classified as demonstrating shrinkage (ratio of volume on last follow-up MRI to MRI immediately preceding irradiation <80%), stability (ratio 80%-120%), or expansion (ratio >120%). The median pre- and postirradiation follow-up was 20.0 and 27.5 months, respectively. Seven tumors from neurofibromatosis type 2 (NF2) patients were excluded from statistical analyses. Results: In the 58 non-NF2 patients, there was a trend of correlation between pre- and postirradiation volume change rates (slope on linear regression, 0.29; P=.06). Tumors demonstrating postirradiation expansion had a median preirradiation growth rate of 89%/year, and those without postirradiation expansion had a median preirradiation growth rate of 41%/year (P=.02). As the preirradiation growth rate increased, the probability of postirradiation expansion also increased. Overall, 24.1% of tumors were stable, 53.4% experienced shrinkage, and 22.5% experienced expansion. Predictors of no postirradiation tumor expansion included no prior surgery (P=.01) and slower tumor growth rate (P=.02). The control of tumors in NF2 patients was only 43%. Conclusions: Radiation therapy is an effective treatment for VS, but tumors that grow quickly preirradiation may be more likely to increase in size. Clinicians should take into account tumor growth rate when counseling patients about treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Dosimetric Factors on Occurrence and Volume of Temporal Lobe Necrosis Following Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma: A Case-Control Study

Purpose: To determine dosimetric risk factors for the occurrence of temporal lobe necrosis (TLN) among nasopharyngeal carcinoma (NPC) patients treated with intensity modulated radiation therapy (IMRT) and to investigate the impact of dose-volume histogram (DVH) parameters on the volume of TLN lesions (V-N). Methods and Materials: Forty-three NPC patients who had developed TLN following IMRT and 43 control subjects free of TLN were retrospectively assessed. DVH parameters included maximum dose (Dmax), minimum dose (Dmin), mean dose (Dmean), absolute volumes receiving specific dose (Vds) from 20 to 76 Gy (V20-V76), and doses covering certain volumes (Dvs) from 0.25 to 6.0 cm{sup 3} (D0.25-D6.0). V-Ns were quantified with axial magnetic resonance images. Results: DVH parameters were ubiquitously higher in temporal lobes with necrosis than in healthy temporal lobes. Increased Vds and Dvs were significantly associated with higher risk of TLN occurrence (P<.05). In particular, Vds at a dose of ≥70 Gy were found with the highest odds ratios. A common increasing trend was detected between V-N and DVH parameters through trend tests (P for trend of <.05). Linear regression analysis showed that V45 had the strongest predictive power for V-N (adjusted R{sup 2} = 0.305, P<.0001). V45 of <15.1 cm{sup 3} was relatively safe as the dose constraint for preventing large TLN lesions with V-N of >5 cm{sup 3}. Conclusions: Dosimetric parameters are significantly associated with TLN occurrence and the extent of temporal lobe injury. To better manage TLN, it would be important to avoid both focal high dose and moderate dose delivered to a large area in TLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

XRCC1 Polymorphism Associated With Late Toxicity After Radiation Therapy in Breast Cancer Patients

Purpose: To identify single-nucleotide polymorphisms (SNPs) in oxidative stress–related genes associated with risk of late toxicities in breast cancer patients receiving radiation therapy. Methods and Materials: Using a 2-stage design, 305 SNPs in 59 candidate genes were investigated in the discovery phase in 753 breast cancer patients from 2 prospective cohorts from Germany. The 10 most promising SNPs in 4 genes were evaluated in the replication phase in up to 1883 breast cancer patients from 6 cohorts identified through the Radiogenomics Consortium. Outcomes of interest were late skin toxicity and fibrosis of the breast, as well as an overall toxicity score (Standardized Total Average Toxicity). Multivariable logistic and linear regression models were used to assess associations between SNPs and late toxicity. A meta-analysis approach was used to summarize evidence. Results: The association of a genetic variant in the base excision repair gene XRCC1, rs2682585, with normal tissue late radiation toxicity was replicated in all tested studies. In the combined analysis of discovery and replication cohorts, carrying the rare allele was associated with a significantly lower risk of skin toxicities (multivariate odds ratio 0.77, 95% confidence interval 0.61-0.96, P=.02) and a decrease in Standardized Total Average Toxicity scores (−0.08, 95% confidence interval −0.15 to −0.02, P=.016). Conclusions: Using a stage design with replication, we identified a variant allele in the base excision repair gene XRCC1 that could be used in combination with additional variants for developing a test to predict late toxicities after radiation therapy in breast cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical Malpractice Claims in Radiation Oncology: A Population-Based Study 1985-2012

Purpose: The purpose of this study was to determine trends in radiation oncology malpractice claims and expenses during the last 28 years and to compare radiation oncology malpractice claims to those of other specialties. Methods and Materials: We performed a retrospective analysis of closed malpractice claims filed from 1985 to 2012, collected by a nationwide medical liability insurance trade association. We analyzed characteristics and trends among closed claims, indemnity payments (payments to plaintiff), and litigation expenses. We also compared radiation oncology malpractice claims to those of 21 other medical specialties. Time series dollar amounts were adjusted for inflation (2012 was the index year). Results: There were 1517 closed claims involving radiation oncology, of which 342 (22.5%) were paid. Average and median indemnity payments were $276,792 and $122,500, respectively, ranking fifth and eighth, respectively, among the 22 specialty groups. Linear regression modeling of time trends showed decreasing total numbers of claims (β = −1.96 annually, P=.003), increasing average litigation expenses paid (β = +$1472 annually, P≤.001), and no significant changes in average indemnity payments (β = −$681, P=.89). Conclusions: Medical professional liability claims filed against radiation oncologists are not common and have declined in recent years. However, indemnity payments in radiation oncology are large relative to those of many other specialties. In recent years, the average indemnity payment has been stable, whereas litigation expenses have increased.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Authorship in Radiation Oncology: Proliferation Trends Over 30 Years

Purpose: To investigate authorship trends in the radiation oncology literature. Methods and Materials: We examined the authorship credits of “original research articles” within 2 popular radiation oncology journals–International Journal of Radiation Oncology, Biology, Physics and Radiotherapy and Oncology–in 1984, 1994, 2004, and 2014. We compared the number of authors per publication during these 4 time periods using simple linear regression as a test for trend. We investigated additional author characteristics in a subset of articles. Results: A total of 2005 articles were eligible. The mean number of authors per publication rose from 4.3 in 1984 to 9.1 in 2014 (P<.001). On subset analysis of 400 articles, there was an increase in the percentage of multidisciplinary bylines (from 52% to 72%), multi-institutional bylines (from 20% to 53%), and publications with a trainee first author (from 16% to 56%) during the study period. Conclusions: The mean number of authors per publication has more than doubled over the last 30 years in the radiation oncology literature. Possible explanations include increasingly complex and collaborative research as well as honorary authorship. Explicit documentation of author contributions could help ensure that scientific work is credited according to accepted standards.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal Cerebral Microbleeds Are Associated With Radiation Necrosis and Cognitive Dysfunction in Patients Treated for Nasopharyngeal Carcinoma

Purpose: Radiation therapy for patients with nasopharyngeal carcinoma (NPC) may be complicated with radiation-induced brain necrosis (RN), resulting in deteriorated cognitive function. However, the underlying mechanism of this phenomenon remains unclear. This study attempts to elucidate the association between cerebral microbleeds (CMBs) and radiation necrosis and cognitive dysfunction in NPC patients treated with radiation therapy. Methods and Materials: This cross-sectional study included 106 NPC patients who were exposed to radiation therapy (78 patients with RN and 28 without RN). Sixty-six patients without discernable intracranial pathology were included as the control group. CMBs were confirmed using susceptibility-weighted magnetic resonance imaging. Cognitive function was accessed using Montreal Cognitive Assessment. Patients with a total score below 26 were defined as cognitively dysfunction. Results: Seventy-seven patients (98.7%) in the RN group and 12 patients (42.9%) in the non-RN group had at least 1 CMB. In contrast, only 14 patients (21.2%) in the control group had CMBs. In patients with a history of radiation therapy, CMBs most commonly presented in temporal lobes (76.4%) followed by cerebellum (23.7%). Patients with RN had more temporal CMBs than those in the non-RN group (37.7 ± 51.9 vs 3.8 ± 12.6, respectively; P<.001). The number of temporal lobe CMBs was predictive for larger volume of brain necrosis (P<.001) in multivariate linear regression analysis. Although cognitive impairment was diagnosed in 55.1% of RN patients, only 7.1% of non-RN patients sustained cognitive impairment (P<.001). After adjusting for age, sex, education, period after radiation therapy, CMBs in other lobes, and RN volume, the number of temporal CMBs remained an independent risk factor for cognitive dysfunction (odds ratio [OR]: 1.03; 95% confidence interval [CI]: 1.01-1.04; P=.003). Conclusions: CMBs is a common radiological manifestation in NPC patients with RN. The number of temporal CMBs is independently associated with increased likelihood of cognitive dysfunction in patients with RN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Global Pattern of Nasopharyngeal Cancer: Correlation of Outcome With Access to Radiation Therapy

Purpose: This study aimed to estimate the treatment outcome of nasopharyngeal cancer (NPC) across the world and its correlation with access to radiation therapy (RT). Methods and Materials: The age-standardized mortality (ASM) and age-standardized incidence (ASI) rates of NPC from GLOBOCAN (2012) were summarized, and [1−(ASM/ASI)] was computed to give the proxy relative survival (RS). Data from the International Atomic Energy Agency (IAEA) and the World Bank were used to assess the availability of RT in surrogate terms: the number of RT equipment units and radiation oncologists per million population. Results: A total of 112 countries with complete valid data were analyzed, and the proxy RS varied widely from 0% to 83% (median, 50%). Countries were categorized into Good, Median, and Poor outcome groups on the basis of their proxy RS (<45%, 45%-55%, and >55%). Eighty percent of new cases occurred in the Poor outcome group. Univariable linear regression showed a significant correlation between outcome and the availability of RT: proxy RS increased at 3.4% (P<.001) and 1.5% (P=.001) per unit increase in RT equipment and oncologist per million population, respectively. The median number of RT equipment units per million population increased significantly from 0.5 in the Poor, to 1.5 in the Median, to 4.6 in the Good outcome groups, and the corresponding number of oncologists increased from 1.1 to 3.3 to 7.1 (P<.001). Conclusions: Nasopharyngeal cancer is a highly treatable disease, but the outcome varies widely across the world. The current study shows a significant correlation between survival and access to RT based on available surrogate indicators. However, the possible reasons for poor outcome are likely to be multifactorial and complex. Concerted international efforts are needed not only to address the fundamental requirement for adequate RT access but also to obtain more comprehensive and accurate data for research to improve cancer outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of the Maximum Dose on White Matter Fiber Bundles Using Longitudinal Diffusion Tensor Imaging

Purpose: Previous efforts to decrease neurocognitive effects of radiation focused on sparing isolated cortical structures. We hypothesize that understanding temporal, spatial, and dosimetric patterns of radiation damage to whole-brain white matter (WM) after partial-brain irradiation might also be important. Therefore, we carried out a study to develop the methodology to assess radiation therapy (RT)–induced damage to whole-brain WM bundles. Methods and Materials: An atlas-based, automated WM tractography analysis was implemented to quantify longitudinal changes in indices of diffusion tensor imaging (DTI) of 22 major WM fibers in 33 patients with predominantly low-grade or benign brain tumors treated by RT. Six DTI scans per patient were performed from before RT to 18 months after RT. The DTI indices and planned doses (maximum and mean doses) were mapped onto profiles of each of 22 WM bundles. A multivariate linear regression was performed to determine the main dose effect as well as the influence of other clinical factors on longitudinal percentage changes in axial diffusivity (AD) and radial diffusivity (RD) from before RT. Results: Among 22 fiber bundles, AD or RD changes in 12 bundles were affected significantly by doses (P<.05), as the effect was progressive over time. In 9 elongated tracts, decreased AD or RD was significantly related to maximum doses received, consistent with a serial structure. In individual bundles, AD changes were up to 11.5% at the maximum dose locations 18 months after RT. The dose effect on WM was greater in older female patients than younger male patients. Conclusions: Our study demonstrates for the first time that the maximum dose to the elongated WM bundles causes post-RT damage in WM. Validation and correlative studies are necessary to determine the ability and impact of sparing these bundles on preserving neurocognitive function after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Computed Tomography– and Magnetic Resonance Imaging–based Clinical Target Volume Contours at Brachytherapy for Cervical Cancer

Purpose: We prospectively compared computed tomography (CT)– and magnetic resonance imaging (MRI)–based high-risk clinical target volume (HR-CTV) contours at the time of brachytherapy for cervical cancer in an effort to identify patients who might benefit most from MRI-based planning. Methods and Materials: Thirty-seven patients who had undergone a pretreatment diagnostic MRI scan were included in the analysis. We delineated the HR-CTV on the brachytherapy CT and brachytherapy MRI scans independently for each patient. We then calculated the absolute volumes for each HR-CTV and the Dice coefficient of similarity (DC, a measure of spatial agreement) for the HR-CTV contours. We identified the clinical and tumor factors associated with (1) a discrepancy in volume between the CT HR-CTV and MRI HR-CTV contours; and (2) DC. The mean values were compared using 1-way analysis of variance or paired or unpaired t tests, as appropriate. Simple and multivariable linear regression analyses were used to model the effects of covariates on the outcomes. Results: Patients with International Federation of Gynecology and Obstetrics stage IB to IVA cervical cancer were treated with intracavitary brachytherapy using tandem and ovoid (n=33) or tandem and cylinder (n=4) applicators. The mean CT HR-CTV volume (44.1 cm{sup 3}) was larger than the mean MRI HR-CTV volume (35.1 cm{sup 3}; P<.0001, paired t test). On multivariable analysis, a higher body mass index (BMI) and tumor size ≥5 cm with parametrial invasion on the MRI scan at diagnosis were associated with an increased discrepancy in volume between the HR-CTV contours (P<.02 for both). In addition, the spatial agreement (as measured by DC) between the HR-CTV contours decreased with an increasing BMI (P=.013). Conclusions: We recommend MRI-based brachytherapy planning for patients with tumors >5 cm and parametrial invasion on MRI at diagnosis and for those with a high BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗