Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Extreme Load Computational Fluid Dynamics Analysis and Verification for a Multibody Wave Energy Converter: Preprint

A wave energy converter (WEC) must be designed to survive the extreme sea states that it will be subject to throughout its lifetime. Although there are many analysis methods and codes available to accomplish this, there are currently several engineering challenges to WEC survival design. Foremost, the computational design approach will typically involve a trade-off between accuracy and computational efficiency. Additionally, most computational fluid dynamics (CFD) codes are not ideally suited to modeling extreme events for WECs with multibody dynamics, power-take-off systems, and mooring systems. Finally, although WEC design standards and CFD guidelines are emerging, with the current immaturity of the WEC industry, they are not yet well established. In this study, loads on a 1:35-scale, moored, multibody WEC are evaluated with CFD. The CFD results are compared with results obtained from a computationally efficient, midfidelity model based on linearized potential flow hydrodynamics. For these model verification comparisons, both operational and survival configurations are considered. The extreme load results obtained, using both codes, indicate that the survival configuration successfully sheds loads during extreme sea states. It is also found that WEC-Sim, when appropriately applied, can provide reasonable load results, at a fraction of the computational expense of CFD. However, for the more extreme sea states, and for higher-order effects not included in the WEC-Sim model, the linear-based results have significant errors in comparison to the CFD-based results, and should be used judiciously.

16 TIDAL AND WAVE POWER↗

Steady state spurious errors in shock-capturing numerical schemes

The behavior of the steady state spurious error modes of the MacCormack scheme and the upwind scheme of Warming and Beam was obtained from a linearized difference equation for the steady state error. It was shown that the spurious errors can exist either as an eigensolution of the homogeneous part of this difference equation or because of excitation from large discretization errors near oblique shocks. It was found that the upwind scheme does not permit spurious oscillations on the upstream side of shocks. Examples are given for the inviscid Burgers' equation and for one and two dimensional gasdynamic flows.

Karlsen, L. K.↗

Effects of modeling errors on trajectory predictions in air traffic control automation

Air traffic control automation synthesizes aircraft trajectories for the generation of advisories. Trajectory computation employs models of aircraft performances and weather conditions. In contrast, actual trajectories are flown in real aircraft under actual conditions. Since synthetic trajectories are used in landing scheduling and conflict probing, it is very important to understand the differences between computed trajectories and actual trajectories. This paper examines the effects of aircraft modeling errors on the accuracy of trajectory predictions in air traffic control automation. Three-dimensional point-mass aircraft equations of motion are assumed to be able to generate actual aircraft flight paths. Modeling errors are described as uncertain parameters or uncertain input functions. Pilot or autopilot feedback actions are expressed as equality constraints to satisfy control objectives. A typical trajectory is defined by a series of flight segments with different control objectives for each flight segment and conditions that define segment transitions. A constrained linearization approach is used to analyze trajectory differences caused by various modeling errors by developing a linear time varying system that describes the trajectory errors, with expressions to transfer the trajectory errors across moving segment transitions. A numerical example is presented for a complete commercial aircraft descent trajectory consisting of several flight segments.

Jackson, Michael R. C.↗

Error Analysis of the Shuttle Reaction Control System Propellant Gaging Module

An investigation of the Shuttle Reaction Control System (RCS) propellant gaging module has revealed that the gaging errors due to the combined effects of random instrumentation measurement errors and propellant loading uncertainties are non-linear over the range of the propellant quantity gage (0-100%), with the largest error occurring at the zero point. When the RCS propellant tanks are filled to contain 100% of the maximum usable propellant, the largest gaging error was determined to be 3.9% for the fuel and 5.4% for the oxidizer. When the RCS propellant tanks initially contain 50% of the maximum usable propellant, the largest gaging error increases to 4.0% for the fuel and 5.6% for the oxidizer.

Duhon, D. D.↗

TH-B-BRC-02: Troubleshooting Issues with Linear Accelerator

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

NR sulphur vulcanization: Interaction study between TBBS and DPG by means of a combined experimental rheometer and meta-model best fitting strategy

The paper is aimed at studying the possible interaction between two different accelerators (DPG and TBBS) in the chemical kinetic of Natural Rubber (NR) vulcanized with sulphur. The same blend with several DPG and TBBS concentrations is deeply analyzed from an experimental point of view, varying the curing temperature in the range 150-180°C and obtaining rheometer curves with a step of 10°C. In order to study any possible interaction between the two accelerators –and eventually evaluating its engineering relevance-rheometer data are normalized by means of the well known Sun and Isayev normalization approach and two output parameters are assumed as meaningful to have an insight into the possible interaction, namely time at maximum torque and reversion percentage. Two different numerical meta-models, which belong to the family of the so-called response surfaces RS are compared. The first is linear against TBBS and DPG and therefore well reproduces no interaction between the accelerators, whereas the latter is a non-linear RS with bilinear term. Both RS are deduced from standard best fitting of experimental data available. It is found that, generally, there is a sort of interaction between TBBS and DPG, but that the error introduced making use of a linear model (no interaction) is generally lower than 10%, i.e. fully acceptable from an engineering standpoint.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feedback Augmented Sub-Ranging (FASR) Quantizer

This innovation is intended to reduce the size, power, and complexity of pipeline analog-to-digital converters (ADCs) that require high resolution and speed along with low power. Digitizers are important components in any application where analog signals (such as light, sound, temperature, etc.) need to be digitally processed. The innovation implements amplification of a sampled residual voltage in a switched capacitor amplifier stage that does not depend on charge redistribution. The result is less sensitive to capacitor mismatches that cause gain errors, which are the main limitation of such amplifiers in pipeline ADCs. The residual errors due to mismatch are reduced by at least a factor of 16, which is equivalent to at least 4 bits of improvement. The settling time is also faster because of a higher feedback factor. In traditional switched capacitor residue amplifiers, closed-loop amplification of a sampled and held residue signal is achieved by redistributing sampled charge onto a feedback capacitor around a high-gain transconductance amplifier. The residual charge that was sampled during the acquisition or sampling phase is stored on two or more capacitors, often equal in value or integral multiples of each other. During the hold or amplification phase, all of the charge is redistributed onto one capacitor in the feedback loop of the amplifier to produce an amplified voltage. The key error source is the non-ideal ratios of feedback and input capacitors caused by manufacturing tolerances, called mismatches. The mismatches cause non-ideal closed-loop gain, leading to higher differential non-linearity. Traditional solutions to the mismatch errors are to use larger capacitor values (than dictated by thermal noise requirements) and/or complex calibration schemes, both of which increase the die size and power dissipation. The key features of this innovation are (1) the elimination of the need for charge redistribution to achieve an accurate closed-loop gain of two, (2) a higher feedback factor in the amplifier stage giving a higher closed-loop bandwidth compared to the prior art, and (3) reduced requirement for calibration. The accuracy of the new amplifier is mainly limited by the sampling networks parasitic capacitances, which should be minimized in relation to the sampling capacitors.

Guilligan, Gerard↗

An hp-adaptivity and error estimation for hyperbolic conservation laws

This paper presents an hp-adaptive discontinuous Galerkin method for linear hyperbolic conservation laws. A priori and a posteriori error estimates are derived in mesh-dependent norms which reflect the dependence of the approximate solution on the element size (h) and the degree (p) of the local polynomial approximation. The a posteriori error estimate, based on the element residual method, provides bounds on the actual global error in the approximate solution. The adaptive strategy is designed to deliver an approximate solution with the specified level of error in three steps. The a posteriori estimate is used to assess the accuracy of a given approximate solution and the a priori estimate is used to predict the mesh refinements and polynomial enrichment needed to deliver the desired solution. Numerical examples demonstrate the reliability of the a posteriori error estimates and the effectiveness of the hp-adaptive strategy.

Bey, Kim S.↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗

Recommendations for Using Noise Monitors to Estimate Noise Exposure During X-59 Community Tests

A low fidelity simulation approach is used to explore how to place and use noise monitors during X-59 QueSST community tests, where people’s annoyance to the noise produced by the X-59 aircraft will be gathered. Several recommendations are provided including: 1) the desired number of sparsely spaced noise monitor sites within the survey area, 2) whether to group and average measurements across multiple noise monitors located at a site, 3) what spacing should be used if grouped noise monitors are used, 4) an approach to mitigate ambient noise contamination at the measurement sites, 5) a method to combine empirical and predicted dose estimates to provide a single dose estimate for respondents, and 6) assessing how changes in turbulence intensity and array configuration affect dose uncertainty. To make these recommendations, the error that is expected when fitting contrived, smoothly varying sonic boom “reference exposure surfaces” is studied when a spatially sparse and scattered set of samples is used as responses for the fit. The reference exposure surfaces mimic the sonic boom exposure at ground level that might be expected in the X-59 survey area in the absence of atmospheric turbulence, ambient noise, and other localized effects. The spatial extent of these surfaces varies and is representative of the different survey area sizes that might be expected during future X-59 community overflight tests. These contrived reference surfaces are sampled, and those reference samples are then perturbed to mimic atmospheric turbulence, ambient noise and other localized effects that might affect noise monitor measurements within overflown communities. Two different surface fitting methods are investigated when fitting these perturbed samples to approximate the reference surface. The first method uses interpolation between the perturbed data at the scattered sites to compute the fit. The second method fits a polynomial surface model to the perturbed data using ordinary least squares regression analysis. For both fitting methods, the root mean square fit error is computed from the pointwise difference between the fit surface and the reference surface as the count and configuration of the sites is varied while also averaging the error across many different realizations of both the smooth variation of the reference exposure surface and the random, localized perturbations at the sample sites. Different site configurations are compared using this error statistic to make the recommendations noted above. Additionally, the two fitting approaches (interpolation vs linear regression) are compared based on the fit error observed in these simulations. These analyses, comparisons, and recommendations should inform future decisions on the noise monitor placement and the methods used to analyze the noise monitor data that is collected during X-59 community overflights.

sonic boom↗

Filtering Methods for Error Reduction in Spacecraft Attitude Estimation Using Quaternion Star Trackers

Precision attitude determination for recent and planned space missions typically includes quaternion star trackers (ST) and a three-axis inertial reference unit (IRU). Sensor selection is based on estimates of knowledge accuracy attainable from a Kalman filter (KF), which provides the optimal solution for the case of linear dynamics with measurement and process errors characterized by random Gaussian noise with white spectrum. Non-Gaussian systematic errors in quaternion STs are often quite large and have an unpredictable time-varying nature, particularly when used in non-inertial pointing applications. Two filtering methods are proposed to reduce the attitude estimation error resulting from ST systematic errors, 1) extended Kalman filter (EKF) augmented with Markov states, 2) Unscented Kalman filter (UKF) with a periodic measurement model. Realistic assessments of the attitude estimation performance gains are demonstrated with both simulation and flight telemetry data from the Lunar Reconnaissance Orbiter.

Calhoun, Philip C.↗

Adjoint Based a posteriori Error Estimation in Drekar::CFD

This document summarizes the results from a level 3 milestone study within the CASL VUQ effort. It demonstrates the capability to perform adjoint-based a posteriori error estimation within Drekar::CFD. The a posteriori error estimates require the solution of a (linear) adjoint problem in a higher order approximation space with data chosen based on the quantity of interest. The a posteriori error estimates are verified using an analytical solution to a laminar flow problem. Finally, the framework is demonstrated on the TH-M Test Case #2 involving a 3-dimensional axisymmetric sudden expansion with a moderate Reynolds numbers ( 5000).

97 MATHEMATICS AND COMPUTING↗

Redesign of the mixed-mode bending delamination test to reduce nonlinear effects

The mixed-mode bending (MMB) test uses a lever to apply simultaneously mode I and mode II loading to a split-beam specimen. An iterative analysis that accounts for the geometric nonlinearity of the MMB test was developed. The analysis accurately predicted the measured load-displacement response and the strain energy release rate, G, of an MMB test specimen made of AS4/PEEK. The errors in G when calculated using linear theory were found to be as large as 30 percent in some cases. Because it would be inconvenient to use a nonlinear analysis to analyze MMB data, the MMB apparatus was redesigned to minimize the nonlinearity. With the improved apparatus, loads are applied just above the midplane of the test specimen through a roller attached to the lever. This apparatus was demonstrated by measuring the mixed-mode delamination fracture toughhess of the test specimen. The nonlinearity errors associated with testing this tough composite material were less than +/- 3 percent. The data from the improved MMB apparatus analyzed with a linear analysis were similar to those found with the original apparatus and the nonlinear analysis.

Reeder, James R.↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Non-NASA Center↗

Deep Learning for Multigroup Cross-Section Representation in Two-Step Core Calculations

Here we investigate using deep learning, a type of machine-learning algorithm employing multiple layers of artificial neurons, for the mathematical representation of multigroup cross sections for use in the Griffin reactor multiphysics code for two-step deterministic neutronics calculations. A three-dimensional fuel element typical of a high-temperature gas reactor as well as a two-dimensional sodium-cooled fast reactor lattice are modeled using the Serpent Monte Carlo code, and multigroup macroscopic cross sections are generated for various state parameters to produce a training data set and a separate validation data set. A fully connected, feedforward neural network is trained using the open-source PyTorch machine-learning framework, and its accuracy is compared against the standard piecewise linear interpolation model. Additionally, we provide in this work a generic technique for propagating the cross-section model errors up to the k eff using sensitivity coefficients with the first-order uncertainty propagation rule. Quantifying the eigenvalue error due to the cross-section regression errors is especially practical for appropriately selecting the mathematical representation of the cross sections. We demonstrate that the artificial neural network model produces lower errors and therefore enables better accuracy relative to the piecewise linear model when the cross sections exhibit nonlinear dependencies; especially when a coarse grid is employed, where the errors can be halved by the artificial neural network. However, for linearly dependent multigroup cross sections as found for the sodium-cooled fast reactor case, a simpler linear regression outperforms deeper networks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-J-24: Setup Uncertainty and Margin of the ExacTrac 6D Image Guide System for Patients with Brain Tumors

Purpose: This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Methods: Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Results: Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ − 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Conclusion: Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.∑σ.

60 APPLIED LIFE SCIENCES↗