Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

An improved storage bulb mount for DSN hydrogen masers

The presently used JPL hydrogen maser suspended atomic storage bulb and a rigid, single-plane mounted bulb are compared. The new bulb incorporates three major design changes: (1) mounting design; (2) alterations to the collimator; and (3) decrease in mass. These design changes are expected to increase the long-term stability of the frequency standard by reducing its sensitivity to vibration and thermal effects.

Dachel, P. R.↗

Mass loss and OH maser emission from Mira variables

The mass, radius, and luminosity of 26 Mira variables that are known OH sources of radio emission at 1612 MHz have been estimated. The time-independent solution of Salpeter's (1974) stellar-wind equation and a period-density relation are used to solve for basic stellar parameters, with the aid of the terminal expansion velocity of the OH maser cloud. Masses obtained from these calculations are consistent with other estimated values for masses of Mira variables. Good agreement is obtained when comparing the rate of mass loss as determined from Reimers's (1977) semiempirical relation with estimates of the mass-loss rate as deduced from theoretical models involving radiation pressure on grains. These calculations suggest a strong correlation between the mass-loss rate and the pulsation period. Arguments concerning the general properties of silicate grains from radiation-pressure-driven stellar-wind equations are discussed.

Michalitsianos, A. G.↗

H2O masers near OB associations

Four new water masers have been found in the vicinity of three OB associations. One of these, in Cep OB3, is among the most intense sources yet discovered and may be related to the most recent epoch of star formation in the OB association. Two others, one in CMa OB1, the other in M16, have large radial velocities relative to their associated molecular clouds. These results are discussed in the context of star formation and CO line self-reversal within the individual sources.

Blitz, L.↗

A reflected-wave ruby maser with K-band tuning range and large instantaneous bandwidth

A novel maser concept is outlined and a unique design described which permits wide bandwidth and waveguide tuning range by employing four stages cascaded via cryogenically cooled circulators. Theoretical considerations for gain, bandwidth, gain ripple, and noise temperature are included. Operated on a closed-cycle helium refrigerator with a superconducting persistence-mode magnet, the four-stage amplifier is tunable from 18.3 to 26.6 GHz with 30 dB of net gain and achieves 240 MHz of 3-dB bandwidth near the center of this band. The measured noise temperature is 13 + or - 2 K referred to the room-temperature input flange. Applications are foreseen utilizing cooled parametric downconverters and upconverters with this amplifier at IF to extend the low-noise performance up to millimeter frequencies and down to L-band for radio astronomy and planetary spacecraft communications.

Moore, C. R.↗

NASA NR hydrogen maser

The Johns Hopkins University, Applied Physics Laboratory, under contract to NASA/Goddard Space Flight Center, is engineering a new generation of field operable hydrogen masers (NR) based on prior NASA NP and NX designs. These units incorporate improvements in magnetic shielding, lower noise electronics, better thermal control and have a microprocessor for operation, monitoring and diagnostic functions. They are ruggedly built for transportability and ease of service anywhere in the world.

Rueger, L. J.↗

Effects of hydrogen atom spin exchange collisions on atomic hydrogen maser oscillation frequency

Frequency shifts due to collisions between hydrogen atoms in an atomic hydrogen maser frequency standard are studied. Investigations of frequency shifts proportional to the spin exchange frequency shift cross section and those proportional to the duration of exchange collisions are discussed. The feasibility of operating a hydrogen frequency standard at liquid helium temperatures is examined.

Crampton, S. B.↗

Hydrogen maser implementation in the Deep Space Network at the Jet Propulsion Laboratory

The Frequency Standard Test Laboratory and its activities are described. The test laboratory has the capability to measure the frequency stability of five frequency standards including environmental parameters. Nine frequency standards may be evaluated simultaneously upon completion of the current instrumentation expansion program. Frequency stability measurements and environmental data on five H-masers are presented.

Kuhnle, P. F.↗

A catalog of nonstellar water maser sources

A list of 195 nonstellar galactic sources of water maser emission has been compiled. This list is not a comprehensive catalog of all the available information; it is intended to be used as an index. As such, it contains only coordinates, velocities, and selected references. The extragalatic sources are listed in a separate table.

Dinger, A. S. C.↗

X-band, low-noise, traveling-wave maser

The development and performance of X-band traveling-wave maser (TWM) systems with effective input noise temperature of 3.5 K and bandwidths varying from 65 to 108 MHz is discussed. These TWMs are used on the 64-meter antennas at Deep Space Stations 14, 43 and 63 at 8420 MHz to meet the requirements of the Voyager-Saturn encounter. The TWMs use shortened and cooled signal input waveguide to reduce noise and are equipped with superconducting magnets and solid-state pump sources to provide the required stability performance.

Trowbridge, D. L.↗

Test of relativistic gravitation with a space-borne hydrogen maser

The results of a test of general relativity with use of a hydrogen-maser frequency standard in a spacecraft launched nearly vertically upward to 10,000 km are reported. The agreement of the observed relativistic frequency shift with prediction is at the 70 x 10 to the -6th level.

Vessot, R. F. C.↗

Far-infrared observations of the H2O masers in NGC 281, NGC 2175, and S255/257

The H2O masers in NGC 281, NGC 2175, and S255/257 have been observed in four far-infrared bands from 40-140 microns with 30 arcsec and 50 arcsec beams. The far-IR positions are consistent with the H2O positions. The far-IR sources have luminosities of 10 to the 4 + or 0.5 solar luminosities, dust temperatures of 36-50 K, H densities greater than 10 to the 4.5, and apparent masses of 12-120 solar masses.

Wright, E. L.↗

Traveling-wave maser, closed cycle refrigerator automation

At the present time all traveling-wave maser and closed-cycle refrigerator system (TWM-CCR) and their power supply and helium compressor assemblies are operated manually. Many man-hours are required of highly trained and experienced operators, resulting in high operator cost. Of greater importance are the problems of unpredictable failure and long downtimes. Since field performance is not monitored, system degradation is detected only when it has progressed to the point of catastrophic failure. Without the aid of performance histories, failure diagnosis is arduous and slow. Rational and functional requirements for the TWM-CCR Automation project are the following: (1) to improve reliability and reduce downtime by providing unattended monitor and control, alarm and fault location, failure prediction and self-corrective action; (2) to reduce operator cost by providing automatic tuning and cooldown procedures; and (3) to improve system operations and development by providing the needed engineering data.

Mcneil, J. A.↗

Maser radiometer for cosmic background radiation anisotropy measurements

A maser amplifier was incorporated into a low noise radiometer designed to measure large-scale anisotropy in the 3 deg K microwave background radiation. To minimize emission by atmospheric water vapor and oxygen, the radiometer is flown in a small balloon to an altitude to 25 km. Three successful flights were made - two from Palestine, Texas and one from Sao Jose dos Campos, Brazil. Good sky coverage is important to the experiment. Data from the northern hemisphere flights has been edited and calibrated.

Fixsen, D. J.↗

Resonant isolator for maser amplifier

An isolator is described for use in a low noise maser amplifier, which provides low loss across a wide bandwidth and which can be constructed at moderate cost. The isolator includes a train of garnet or ferrite elements extending along the length of a microwave channel parallel to the slow wave structure, with the elements being of staggered height, so that the thin elements which are resonant to the microwaves are separated by much thicker elements. The thick garnet or ferrite elements reduce the magnetic flux passing through the thin elements to permit altering of the shape of the thin elements so as to facilitate their fabrication and to provide better isolation with reduced loss, by increasing the thickness of the thin elements and decreasing their length and width.

Clauss, R. C.↗

High-accuracy global time and frequency transfer with a space-borne hydrogen maser clock

A proposed system for high-accuracy global time and frequency transfer using a hydrogen maser clock in a space vehicle is discussed. Direct frequency transfer with a accuracy of 10 to the minus 14th power and time transfer with an estimated accuracy of 1 nsec are provided by a 3-link microwave system. A short pulse laser system is included for subnanosecond time transfer and system calibration. The results of studies including operational aspects, error sources, data flow, system configuration, and implementation requirements for an initial demonstration experiment using the Space Shuttle are discussed.

Decher, R.↗

Collisional rates for vibrational-rotational transitions in circumstellar SiO masers

Calculations for rotational population inversion in circumstellar SiO masers require collisional rates for vibrational-rotational transitions. This paper reports quantum mechanical, state-to-state collisional rate coefficients for pure rotational and vibrational-rotational transitions among the first three vibrational states of SiO. These are expressed in terms of simple two-parameter power-law fits accurate in the temperature range 1000-3000 K.

Bieniek, R. J.↗

An electron cyclotron maser instability for astrophysical plasmas

The electron cyclotron maser instability is analyzed for a plasma which consists of a suprathermal electron component characterized by velocity-space anisotropies in directions both parallel and perpendicular to the ambient magnetic field, as well as a high-density thermal plasma in which omega sub e is approximately equal to Omega sub e (where omega sub e and Omega sub e are the electron plasma and cyclotron frequencies). The complete relativistic resonance condition is used and shown to result in a 'resonance ellipse' in momentum space. The instability is considered for both cold and warm suprathermal electron distributions, and for frequencies omega approximately equal to Omega sub e in the ordinary mode and omega approximately equal to 2(Omega sub e) in the fast extraordinary mode. It is shown that the growth rates are comparable for these harmonics over a wide range of parameters which, since they are escape modes of the plasma, can lead to comparable radiation intensities.

Freund, H. P.↗

Detailed design of a variable volume hydrogen maser

Identification of the hydrogen maser design parameters include the shape of the bulk, q (quality parameter), tuning factors, materials to be used, and operational temperature to offset the wall shift. Expressions for the statistic error on the measured frequency were derived. Localized variations in the concentration of excited atoms were studied and how the shape of the container (the ratio of surface to volume in particular) affects their behavior.

Cervenka, P. O.↗