Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

AN ALMA SURVEY OF SUBMILLIMETER GALAXIES IN THE EXTENDED CHANDRA DEEP FIELD SOUTH: SOURCE CATALOG AND MULTIPLICITY

We present an Atacama Large Millimeter/submillimeter Array (ALMA) Cycle 0 survey of 126 submillimeter sources from the LABOCA ECDFS Submillimeter Survey (LESS). Our 870 {mu}m survey with ALMA (ALESS) has produced maps {approx}3 Multiplication-Sign deeper and with a beam area {approx}200 Multiplication-Sign smaller than the original LESS observations, doubling the current number of interferometrically-observed submillimeter sources. The high resolution of these maps allows us to resolve sources that were previously blended and accurately identify the origin of the submillimeter emission. We discuss the creation of the ALESS submillimeter galaxy (SMG) catalog, including the main sample of 99 SMGs and a supplementary sample of 32 SMGs. We find that at least 35% (possibly up to 50%) of the detected LABOCA sources have been resolved into multiple SMGs, and that the average number of SMGs per LESS source increases with LESS flux density. Using the (now precisely known) SMG positions, we empirically test the theoretical expectation for the uncertainty in the single-dish source positions. We also compare our catalog to the previously predicted radio/mid-infrared counterparts, finding that 45% of the ALESS SMGs were missed by this method. Our {approx}1.''6 resolution allows us to measure a size of {approx}9 kpc Multiplication-Sign 5 kpc for the rest-frame {approx}300 {mu}m emission region in one resolved SMG, implying a star formation rate surface density of 80 M{sub Sun} yr{sup -1} kpc{sup -2}, and we constrain the emission regions in the remaining SMGs to be <10 kpc. As the first statistically reliable survey of SMGs, this will provide the basis for an unbiased multiwavelength study of SMG properties.

79 ASTRONOMY AND ASTROPHYSICS↗

A SURVEY OF STELLAR FAMILIES: MULTIPLICITY OF SOLAR-TYPE STARS

We present the results of a comprehensive assessment of companions to solar-type stars. A sample of 454 stars, including the Sun, was selected from the Hipparcos catalog with {pi}>40 mas, {sigma}{sub {pi}/{pi}} < 0.05, 0.5 {<=} B - V {<=} 1.0 ({approx}F6-K3), and constrained by absolute magnitude and color to exclude evolved stars. These criteria are equivalent to selecting all dwarf and subdwarf stars within 25 pc with V-band flux between 0.1 and 10 times that of the Sun, giving us a physical basis for the term 'solar-type'. New observational aspects of this work include surveys for (1) very close companions with long-baseline interferometry at the Center for High Angular Resolution Astronomy Array, (2) close companions with speckle interferometry, and (3) wide proper-motion companions identified by blinking multi-epoch archival images. In addition, we include the results from extensive radial-velocity monitoring programs and evaluate companion information from various catalogs covering many different techniques. The results presented here include four new common proper-motion companions discovered by blinking archival images. Additionally, the spectroscopic data searched reveal five new stellar companions. Our synthesis of results from many methods and sources results in a thorough evaluation of stellar and brown dwarf companions to nearby Sun-like stars. The overall observed fractions of single, double, triple, and higher-order systems are 56% {+-} 2%, 33% {+-} 2%, 8% {+-} 1%, and 3% {+-} 1%, respectively, counting all confirmed stellar and brown dwarf companions. If all candidate, i.e., unconfirmed, companions identified are found to be real, the percentages would change to 54% {+-} 2%, 34% {+-} 2%, 9% {+-} 2%, and 3% {+-} 1%, respectively. Our completeness analysis indicates that only a few undiscovered companions remain in this well-studied sample, implying that the majority (54% {+-} 2%) of solar-type stars are single, in contrast to the results of prior multiplicity studies. Our sample is large enough to enable a check of the multiplicity dependence on various physical parameters by analyzing appropriate subsamples. Bluer, more massive stars are seen as more likely to have companions than redder, less massive ones, consistent with the trend seen over the entire spectral range. Systems with larger interaction cross sections, i.e., those with more than two components or long orbital periods, are preferentially younger, suggesting that companions may be stripped over time by dynamical interactions. We confirm the planet-metallicity correlation (i.e., higher metallicity stars are more likely to host planets), but are unable to check it for brown dwarfs due to the paucity of such companions, implying that the brown dwarf desert extends over all separation regimes. We find no correlation between stellar companions and metallicity for B - V < 0.625, but among the redder subset, metal-poor stars ([Fe/H] <-0.3) are more likely to have companions with a 2.4{sigma} significance. The orbital-period distribution of companions is unimodal and roughly log normal with a peak and median of about 300 years. The period-eccentricity relation shows the expected circularization for periods below 12 days, caused by tidal forces over the age of the Galaxy, followed by a roughly flat distribution. The mass-ratio distribution shows a preference for like-mass pairs, which occur more frequently in relatively close pairs. The fraction of planet hosts among single, binary, and multiple systems are statistically indistinguishable, suggesting that planets are as likely to form around single stars as they are around components of binary or multiple systems with sufficiently wide separations. This, along with the preference of long orbital periods among stellar systems, increases the space around stars conducive for planet formation, and perhaps life.

79 ASTRONOMY AND ASTROPHYSICS↗

Angle-resolved photon-coincidence measurements in a multiple-scattering medium

We present angle-resolved correlation measurements between photons after propagation through a three-dimensional disordered medium. The multiple-scattering process induces photon correlations that are directly measured for light sources with different photon statistics. We find that multiple-scattered photons between different angular directions with angles much larger than the average speckle width are strongly correlated. The time dependence of the angular photon correlation function is investigated, and the coherence time of the light source is determined. Our results are found to be in excellent agreement with the continuous mode quantum theory of multiple scattering of light. The presented experimental technique is essential in order to study quantum phenomena in multiple-scattering random media, such as quantum interference and quantum entanglement of photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy dependence of multiplicity fluctuations in heavy ion collisions at 20A to 158A GeV

Multiplicity fluctuations of positively, negatively, and all charged hadrons in the forward hemisphere were studied in central Pb+Pb collisions at 20A,30A,40A,80A, and 158A GeV. The multiplicity distributions and their scaled variances {omega} are presented as functions of their dependence on collision energy as well as on rapidity and transverse momentum. The distributions have bell-like shapes and their scaled variances are in the range from 0.8 to 1.2 without any significant structure in their energy dependence. No indication of the critical point in fluctuations are observed. The string-hadronic ultrarelativistic quantum molecular dynamics (UrQMD) model significantly overpredicts the mean, but it approximately reproduces the scaled variance of the multiplicity distributions. The predictions of the statistical hadron-resonance gas model obtained within the grand-canonical and canonical ensembles disagree with the measured scaled variances. The narrower than Poissonian multiplicity fluctuations measured in numerous cases may be explained by the impact of conservation laws on fluctuations in relativistic systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Multiple-Muon Charge Ratio in the MINOS Far Detector

The charge ratio, Rμ=Nμ+/Nμ-, for cosmogenic multiple-muon events observed at an underground depth of 2070 mwe has been measured using the magnetized MINOS Far Detector. The multiple-muon events, recorded nearly continuously from August 2003 until April 2012, comprise two independent data sets imaged with opposite magnetic field polarities, the comparison of which allows the systematic uncertainties of the measurement to be minimized. The multiple-muon charge ratio is determined to be Rμ=1.104±0.006(stat)-0.010+0.009(syst). This measurement complements previous determinations of single-muon and multiple-muon charge ratios at underground sites and serves to constrain models of cosmic-ray interactions at TeV energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicative Shot-Noise: A New Route to Stability of Plastic Networks

Fluctuations of synaptic weights, among many other physical, biological, and ecological quantities, are driven by coincident events of two “parent” processes. Here we propose a multiplicative shot-noise model that can capture the behaviors of a broad range of such natural phenomena, and analytically derive an approximation that accurately predicts its statistics. We apply our results to study the effects of a multiplicative synaptic plasticity rule that was recently extracted from measurements in physiological conditions. Using mean-field theory analysis and network simulations, we investigate how this rule shapes the connectivity and dynamics of recurrent spiking neural networks. The multiplicative plasticity rule is shown to support efficient learning of input stimuli, and it gives a stable, unimodal synaptic-weight distribution with a large fraction of strong synapses. The strong synapses remain stable over long times but do not “run away.” Our results suggest that the multiplicative shot-noise offers a new route to understand the tradeoff between flexibility and stability in neural circuits and other dynamic networks.

59 BASIC BIOLOGICAL SCIENCES↗

High-energy interactions in the region of extreme multiplicities

Hadron and nuclear interactions at high energies in the region of extreme multiplicities (much higher than mean multiplicities) are reviewed. Collective phenomena such as Bose-Einstein condensation, Cherenkov gluon radiation, clustering, and an excess yield of soft photons may manifest themselves in this region. The phenomenological gluon-dominance model developed for describing extreme multiplicities predicts the restrictions on their values and the type of hadronization mechanism and makes it possible to estimate thee size of the hadronization region. The status of the research within the Thermalization project at the U-70 accelerator of the Institute for High Energy Physics (IHEP, Protvino) is reported, and information about searches for new collective phenomena and about studies of known ones in the region of extreme multiplicities is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fission prompt gamma-ray multiplicity distribution measurements and simulations at DANCE

The nearly energy independence of the DANCE efficiency and multiplicity response to {gamma} rays makes it possible to measure the prompt {gamma}-ray multiplicity distribution in fission. We demonstrate this unique capability of DANCE through the comparison of {gamma}-ray energy and multiplicity distribution between the measurement and numerical simulation for three radioactive sources {sup 22}Na, {sup 60}Co, and {sup 88}Y. The prospect for measuring the {gamma}-ray multiplicity distribution for both spontaneous and neutron-induced fission is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Detector Signal Processing to Calculate the Effective Neutron Multiplication Factor of Subcritical Assemblies

This report describes different methodologies to calculate the effective neutron multiplication factor of subcritical assemblies by processing the neutron detector signals using MATLAB scripts. The subcritical assembly can be driven either by a spontaneous fission neutron source (e.g. californium) or by a neutron source generated from the interactions of accelerated particles with target materials. In the latter case, when the particle accelerator operates in a pulsed mode, the signals are typically stored into two files. One file contains the time when neutron reactions occur and the other contains the times when the neutron pulses start. In both files, the time is given by an integer representing the number of time bins since the start of the counting. These signal files are used to construct the neutron count distribution from a single neutron pulse. The built-in functions of MATLAB are used to calculate the effective neutron multiplication factor through the application of the prompt decay fitting or the area method to the neutron count distribution. If the subcritical assembly is driven by a spontaneous fission neutron source, then the effective multiplication factor can be evaluated either using the prompt neutron decay constant obtained from Rossi or Feynman distributions or the Modified Source Multiplication (MSM) method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MicroRNAs as disease progression biomarkers and therapeutic targets in experimental autoimmune encephalomyelitis model of multiple sclerosis

Multiple sclerosis is an autoimmune neurodegenerative disease of the central nervous system characterized by pronounced inflammatory infiltrates entering the brain, spinal cord and optic nerve leading to demyelination. Focal demyelination is associated with relapsing-remitting multiple sclerosis, while progressive forms of the disease show axonal degeneration and neuronal loss. The tests currently used in the clinical diagnosis and management of multiple sclerosis have limitations due to specificity and sensitivity. MicroRNAs (miRNAs) are dysregulated in many diseases and disorders including demyelinating and neuroinflammatory diseases. A review of recent studies with the experimental autoimmune encephalomyelitis animal model (mostly female mice 6–12 weeks of age) has confirmed miRNAs as biomarkers of experimental autoimmune encephalomyelitis disease and importantly at the pre-onset (asymptomatic) stage when assessed in blood plasma and urine exosomes, and spinal cord tissue. The expression of certain miRNAs was also dysregulated at the onset and peak of disease in blood plasma and urine exosomes, brain and spinal cord tissue, and at the post-peak (chronic) stage of experimental autoimmune encephalomyelitis disease in spinal cord tissue. Therapies using miRNA mimics or inhibitors were found to delay the induction and alleviate the severity of experimental autoimmune encephalomyelitis disease. Interestingly, experimental autoimmune encephalomyelitis disease severity was reduced by overexpression of miR-146a, miR-23b, miR-497, miR-26a, and miR-20b, or by suppression of miR-182, miR-181c, miR-223, miR-155, and miR873. Further studies are warranted on determining more fully miRNA profiles in blood plasma and urine exosomes of experimental autoimmune encephalomyelitis animals since they could serve as biomarkers of asymptomatic multiple sclerosis and disease course. Additionally, studies should be performed with male mice of a similar age, and with aged male and female mice.

59 BASIC BIOLOGICAL SCIENCES↗

A Persistent Feature of Multiple Scattering of Waves in the Time-Domain: A Tutorial

The equations for frequency-domain multiple scattering are derived for a scalar or electromagnetic plane wave incident on a collection of particles at known positions, and in the time-domain for a plane wave pulse incident on the same collection of particles. The calculation is carried out for five different combinations of wave types and particle types of increasing geometrical complexity. The results are used to illustrate and discuss a number of physical and mathematical characteristics of multiple scattering in the frequency- and time-domains. We argue that frequency-domain multiple scattering is a purely mathematical construct since there is no temporal sequencing information in the frequency-domain equations and since the multi-particle path information can be dispelled by writing the equations in another mathematical form. However, multiple scattering becomes a definite physical phenomenon in the time-domain when the collection of particles is illuminated by an appropriately short localized pulse.

particles↗

Practical Aspects of Multiple-Input Design for Aircraft System Identification Flight Tests

Practical aspects of multiple-input design methods for aircraft system identification flight tests are discussed. The orthogonal optimized multisine multiple-input design technique is explained and demonstrated, along with useful variations. Practical implementation and application issues associated with applying orthogonal optimized multisine inputs in flight are explained, and solutions are demonstrated using flight data from full-scale and subscale aircraft, as well as simulated flight data from an F-16 nonlinear simulation. Topics include truncated and extended excitation inputs, variations for control effectors with limited movement capabilities, aircraft dynamic response to excitation inputs, pilot implementation, statistical uncertainty quantification, multiple-input efficiency and effectiveness, flight testing with active feedback control, frequency-response estimation, control actuator modeling, and control interaction effects. Examples demonstrate that the orthogonal optimized multisine input design method is a practical, versatile, and effective approach for designing multiple excitation inputs for aircraft system identification flight tests.

Multiple-Input Design↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Analysis Technique for Active Neutron Multiplicity Measurements Based on First Principles

Passive neutron multiplicity counting is commonly used to quantify the total mass of plutonium in a sample, without prior knowledge of the sample geometry. However, passive neutron counting is less applicable to uranium measurements due to the low spontaneous fission rates of uranium. Active neutron multiplicity measurements are therefore used to determine the {sup 235}U mass in a sample. Unfortunately, there are still additional challenges to overcome for uranium measurements, such as the coupling of the active source and the uranium sample. Techniques, such as the coupling method, have been developed to help reduce the dependence of calibration curves for active measurements on uranium samples; although, they still require similar geometry known standards. An advanced active neutron multiplicity measurement method is being developed by Texas A&M University, in collaboration with Los Alamos National Laboratory (LANL) in an attempt to overcome the calibration curve requirements. This method can be used to quantify the {sup 235}U mass in a sample containing uranium without using calibration curves. Furthermore, this method is based on existing detectors and nondestructive assay (NDA) systems, such as the LANL Epithermal Neutron Multiplicity Counter (ENMC). This method uses an inexpensive boron carbide liner to shield the uranium sample from thermal and epithermal neutrons while allowing fast neutrons to reach the sample. Due to the relatively low and constant fission and absorption energy dependent cross-sections at high neutron energies for uranium isotopes, fast neutrons can penetrate the sample without significant attenuation. Fast neutron interrogation therefore creates a homogeneous fission rate in the sample, allowing for first principle methods to be used to determine the {sup 235}U mass in the sample. This paper discusses the measurement method concept and development, including measurements and simulations performed to date, as well as the potential limitations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Neutron Multiplicity Deadtime Scheme

Deadtime corrections for passive neutron coincidence counting are traditionally formulated in terms of the Totals counting rate. The deadtime correction is exponential in form with the effective deadtime being linear in terms of observed Totals rate. The deadtime coefficient for the Reals rate is traditionally fixed at four times that of the Totals rate parameter. When it comes to multiplicity counting, however, more complex expressions are typically used for the Doubles and Triples rates based on mathematical actions to the multiplicity histograms with the Singles (or Trigger) rate being treated rather simplistically. Since the Totals and Singles and Reals and Doubles, respectively, are effectively equivalent measures, the difference in deadtime treatment results is an inconsistency. Furthermore, additional empirical correction factors are often applied in the case of the multiplicity deadtime corrections and these do not follow from the underlying theoretical framework. The purpose of this paper is to re-examine the semi-empirical deadtime correction expressions from a fresh perspective. We propose to a scheme whereby Totals and Singles are treated equivalently with the correction having the transcendental form of the paralysable model. The impact of correlations on the Totals deadtime correction is shown to be modest. The deadtime correction factor for Reals and Doubles are again treated similarly also using an exponential form in terms of the corrected Total event rate but with a deadtime parameter which is not fixed ahead of time to be four times that used in the Totals correction. In the case of the Triples correction, which is evaluated from a composite expression, the deadtime corrections for the Singles and Doubles are used as appropriate but a new empirical correction, again given in terms of the corrected rate, is introduced. The new correction acts only on the part of the Triples expression which is does not represent the correlated-accidentals. The new scheme is not based on an elaborate mathematical model for deadtime losses and consequently does not involve a deadtime-function-weighted sum of histogram elements. In that sense it is simpler to understand and implement. Determination of the free deadtime parameters is based on first extracting the deadtime parameter for the Singles for which several options are available. The Doubles deadtime parameter is then based on rendering the corrected Doubles to Singles ratio for Cf-252 invariant to trigger rate. Similarly the Triple deadtime parameter is extracted from Cf-252 data given the Singles (or Trigger) and Doubles parameters. In this article we briefly review current practice, lay out the new concept and illustrate their application with experimental data of a passive neutron multiplicity counter. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computationally Guided Design of Multiple Impurities Tolerant Cathode for Solid Oxide Fuel Cell Applications

Solid oxide fuel cells (SOFCs) have been recognized as promising candidates in the demand of reducing the dependence on fossil fuels, which is one of the solutions to the threat of global warming. It was reported that the direct chemical-to-electrical energy conversion in SOFCs comes with negligible emission of greenhouse gases and up to 60% working efficiency. SOFC has unique advantages over traditional power generation technologies and other types of fuel cells due to the use of relatively inexpensive materials, low sensitivity to poisoning impurities in fuels, relatively high conversion efficiency, and fuel flexibility (like carbon-based fuels). However, during the SOFC operation, the cathode is exposed to intrinsic and extrinsic airborne contaminants at high temperatures (600–900°C), leading to their reaction with electrode materials, irreversible chemical and structural changes, and electrochemical performance degradation. of which CO2, SO2, Cr6+ and H2O are known to be concerns. Thus, developing a comprehensive understanding of the multiple impurities poisoning of SOFC cathodes in the presence of single or multiple impurities is necessary to address the long-term degradation of the SOFC cathode systems at operating conditions. An integrated computational and experimental approach has been utilized in the current work aiming at the comprehensive investigation of the cathode materials under single or multiple impurities poisoning effects, understanding the multiple impurities poisoning mechanism(s), and improving the long-term durability of the SOFC cathodes to develop better performing impurity-tolerant cathode materials. We first examined the agreement between the simulation approach and the experimental observations at various atmospheric and temperature conditions to confirm the reliability of CALPHAD for poisoning simulations in these cathodes. Then, using this approach, we investigated the accelerated testing protocol, which has become the standard method for conducting impurity poisoning experiments involving these cathode materials. We found our simulation approach is able to predict in which systems, i.e., cathode material and treatment environment, the accelerated testing protocols reflect actual operating conditions. Finally, in-depth simulations were done for these three candidate cathodes under different experimental conditions and suggested directions toward alternative cathode materials that have superior impurity tolerance.

36 MATERIALS SCIENCE↗

Simulation of moderated plutonium neutron multiplicity measurements.

The purpose of this work is to improve detection methods that can reliably identify special nuclear material (SNM). One method that can be used to identify special nuclear material is neutron multiplicity analysis. This method detects multiple time-correlated neutrons released from a fission event in the SNM. This work investigates the ability of the software code MCNP-PoliMi to simulate neutron multiplicity measurements from a highly moderated SNM source. A measurement of a 4.5-kg alpha-phase metal plutonium sphere surrounded by up to 6 inches of polyethylene shells has recently been performed by Sandia National Laboratories personnel at the Nevada Test Site. A post-processing code was developed to account for dead-time effects within the detector and to determine the neutron multiplicity distributions for various time intervals. With the distributions calculated, the Feynman-Y can be determined. The Feynman-Y is a metric that measures the level of correlation present in a sample. At this time MCNP-PoliMi is able predict the Feynman-Y within 10% of the measured value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗