Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measure control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Wake Steering Wind Farm Control With Preview Wind Direction Information: Preprint

Wake steering is a wind farm control strategy in which upstream turbines operate with a yaw misalignment to deflect their wakes away from downstream turbines, yielding a net power gain for the wind plant. But the inability of wake steering controllers to perfectly track the wind direction leads to suboptimal performance. In this paper, we propose the use of preview wind direction measurements upstream of the turbine to improve controller performance by anticipating wind direction changes. Further, data from an operational wind plant are used to determine realistic preview measurement accuracy. Using the FLORIS engineering wind farm control tool, we compare the performance of standard and preview-enabled baseline and wake steering control for a two-turbine array during below-rated operation. Assuming perfect preview information, preview-based wake steering increases energy production by the equivalent of 9.5% of the baseline wake losses, compared to a wake loss recovery of 5.6% with standard wake steering. However, when realistic measurement accuracy is included, the preview-based controller provides no advantage over standard control, motivating the need for more sophisticated control and wind direction forecasting strategies.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

Measurement of AmLi Sources for Active Well Coincidence Counter

To support the use of the Oak Ridge National Laboratory (ORNL) large-volume active well coincidence counter (LV-AWCC) in material control and accountancy (MC&A) measurements, a set of AmLi neutron sources was acquired from Savannah River National Laboratory (SRNL). These sources were measured to verify their suitability for use in the ORNL LV-AWCC. The sources produce neutrons at a rate that is within 4% of the rate for one set of AmLi sources already in use and 40% higher than the rate for the other set. These measurements indicate that the SRNL sources are suitable for use in the LV-AWCC because their sensitivity and measurement precision will be similar to those of the sets already in use. However, the SRNL sources still need to be evaluated for MC&A use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Algae Biofilm Produced from Anaerobic Digester Wastewater Demonstrated as Biofertilizer for Dwarf Wheat

Aims: To correlate yield of dwarf wheat fertilized with algae biofilm produced using anaerobic digester effluent (digestate) from a municipal water resource recovery facility as nutrient source and compare with yield using non-algae biofilm based fertilizers and a negative control. Study Design: Greenhouse testing for measurement of biomass yields and statistical analysis of wheat yield data results. Place and Duration of Study: Department of Biological Engineering Algae Processing and Products Facility greenhouse between March and June, 2024. Methodology: Yield of a dwarf cultivar of red spring wheat was measured as a function of four treatments including three fertilizers and a negative control: (1) algae biofilm cultivated on anaerobic digester effluent, (2) positive control of Osmocote commercial slow release fertilizer, (3) anaerobic digester biosolids, and (4) negative control with no fertilizer addition. Results: Average yield values (gm) for the four treatments were: (1) 1.25, (2) 0.99, (3) 0.72, and (4) 0.52, respectively. Algae biofilm fertilizer performed significantly better than Osmocote with P = .002, anaerobic digester biosolids with P = .05, and no fertilizer addition with P = .05. Struvite, a slow release fertilizer, was observed to be associated with the algae biofilm as a precipitate of the high concentrations of nutrients within the anaerobic digester water. Struvite (MgNH4PO46H2O) releases plant available nitrogen and phosphorus over time and is biologically precipitated due to the increase in solution pH as a result of photosynthesis by the algae biofilm. Conclusion: Algae biofilm cultivated on anaerobic digester wastewater can serve as a biofertilizer for recycling nutrients within the biosphere for sustainable nutrient management.

09 BIOMASS FUELS↗

Effect of proton irradiation temperature on persistent photoconductivity in zinc oxide metal-semiconductor-metal ultraviolet photodetectors

The electrical and structural characteristics of 50-nm-thick zinc oxide (ZnO) metal-semiconductor-metal ultraviolet (UV) photodetectors subjected to proton irradiation at different temperatures are reported and compared. The devices were irradiated with 200 keV protons to a fluence of 1016 cm−2. Examination of the x-ray diffraction (XRD) rocking curves indicates a preferred (100) orientation prior to irradiation, with decrease in crystal quality afterward. Additionally, peak shifts in XRD and Raman spectra of the control sample relative to well-known theoretical positions are indicative of tensile strain in the as-deposited ZnO films. Shifts toward theoretical unstrained positions are observed in the irradiated films, which indicates partial relaxation. Raman spectra also indicate increase in oxygen vacancies (VO) and zinc interstitial defects (Zni) compared to the control sample. Additionally, transient photocurrent measurements performed on each sample at different temperatures showed up to 2× increase in photocurrent decay time constants for irradiated samples vs the control. This persistent photoconductive behavior is linked to the activation of electron and hole traps near the surface, and to the desorption and reabsorption of O2 molecules on the ZnO surface under the influence of UV light. Using an Arrhenius model, trap activation energies were extracted and, by comparing with known energies from the literature, the dominant defects contributing to persistent photoconductivity for each irradiation condition were identified. The persistence of differences in photocurrent transients between different samples months after irradiation indicates that the defects introduced by the suppression of thermally activated dynamic annealing processes have a long-term deleterious effect on device performance.

Heuser, Thomas A. (ORCID:0000000225642400)↗

Qualification and Re-Qualification of NDA Instruments

Non-Destructive Assay (NDA) instruments are a large component of nuclear material (NM) measurement at LANL. Nuclear Material Control and Accountability Group (SAFE-NMCA) personnel in the Safeguards Division are responsible for oversight of the instruments used for material accountability measurements. It is the responsibility of SAFE-NMCA to ensure that all instruments are operating as expected and can produce quality measurements to provide assurance that requirements of the DOE approved NMCA Plan are being met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-healing, self-assembling islanded power systems using only local measurements

This SAND report collects the results from the LDRD project “SHAZAM”, which aimed to push the limits of performance for self-healing, self-assembling power systems whose sectionalizing and load-control agents rely on local measurements only (i.e., only what they can measure at their own terminals, with no data sharing between agents). This work includes self-networking microgrids. The key objectives of this work were a) to demonstrate how high the performance of local-measurement-only self-assembling power systems can be; and b) to solve certain technical problems associated with such systems, such as their inability to prevent the accidental formation of closed loops and their tendency to thermally overload some conductors. “SHAZAM” investigators a) demonstrated that the performance of such systems can be surprisingly high, b) demonstrated that such systems are quite robust to all kinds of variations, and c) developed and demonstrated solutions to several key challenges associated with this type of system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Long-term Monitoring of Contaminated Groundwater at Sites where Attenuation-based Remedies are Deployed

This study presents an effective approach to tackle the challenge of long-term monitoring of contaminated groundwater sites where remediation leaves residual contamination in the subsurface. Traditional long-term monitoring of contaminated groundwater sites focuses on measuring contaminant concentrations and is applicable to sites where contaminant mass is removed or degraded to a level below the regulatory standard. The traditional approach is less effective at sites where risk from metals or radionuclides continues to exist in the subsurface after remedial goals are achieved. We propose a long-term monitoring strategy for this type of waste site that focuses on measuring the hydrological and geochemical parameters that control attenuation or remobilization of contaminants while de-emphasizing contaminant-concentration measurements. Furthermore, we demonstrate how this approach would be more effective than traditional long-term monitoring, using a site in South Carolina, USA, where groundwater is contaminated by several radionuclides. A comprehensive enhanced attenuation remedy has been implemented at the site to minimize discharge of contamination to surface water. The immobilization of contaminants occurs in three locations by manipulation of hydrological and geochemical parameters, as well as by natural attenuation processes. Deployment of our proposed long-term monitoring strategy will combine subsurface and surface measurements using spectroscopic tools, geophysical tools, and sensors to monitor the parameters controlling contaminant attenuation. The advantage of this approach is that it will detect the potential for contaminant remobilization from engineered and natural attenuation zones, allowing potential adverse changes to be mitigated before contaminant attenuation is reversed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active control of electron cyclotron emission radiometer channel frequencies for improved electron temperature measurements

As advanced scenarios are developed for tokamak operations, the demand for flexibility of the electron cyclotron emission (ECE) channels’ locations has increased. The tunable feature of yttrium iron garnet (YIG) filters provides this spatial flexibility. Here, we present a method of performing ECE measurements on fixed flux surfaces instead of fixed frequencies. This is achieved by adjusting YIG filters utilized in the intermediate frequency section to frequencies associated with flux surfaces in regions of interest during the discharge. Here, the key components are the application of tunable YIG filters and a control program that calculates the filter settings using flux information from real-time reconstruction equilibria (EFIT). This fast procedure facilitates T e measurements in regions of interest to investigate plasma dynamic behaviors.

47 OTHER INSTRUMENTATION↗

Self-tuning wave energy converter (WEC) controller for changing sea states

Systems and methods for a WEC controller that uses a self-tuning proportional-integral control law prescribing motor torques to maximize electrical power generation and automatically tune the controller to maximize power absorption. In an embodiment, the controller may be part of any resonant WEC system. The control law relies upon an identified model of device intrinsic impedance to generate a frequency-domain estimate of the wave-induced excitation force and measurements of device velocities. The control law was tested in irregular sea-states that evolved over hours (a rapid, but realistic time-scale) and that changed instantly (an unrealistic scenario to evaluate controller response).

Bacelli, Giorgio↗

Evaluation of Radiography for TRISO Buffer Layer Density Measurement

Tristructural isotropic (TRISO) fuel particles consist of a central uranium-bearing kernel and a series of coating layers designed to retain fission products and to ensure fuel performance. Several parameters such as thickness and density must be measured for these coating layers to show that they conform with fuel specifications. Current methods for measuring the density of pyrolytic carbon and silicon carbide layers (liquid gradient density column) and the buffer layer (mercury porosimetry) generate Resource Conservation and Recovery Act (RCRA) radiological-mixed waste. In addition, measurement of buffer and inner pyrolytic carbon layer densities require hot sampling or interrupted coating runs and the mercury porosimetry method used for buffer density measurement only measures the mean buffer density, not the interparticle distribution. A new approach has been evaluated to measure the density of coating layers in TRISO particles based on the dependence of x-ray attenuation in radiographs on material density. This method does not generate RCRA mixed waste, measures density on a particle-by-particle basis, and in principle is capable of measuring the density of all coating layers in a single process. Initial results using thinned TRISO particle sections to evaluate radiography measurement of density as a quality control characterization method are reported herein. In this work, the primary focus is on measurement of the density of the buffer layer; however, with appropriate calibration the method should be applicable to other coating layers. Improvements to the initial method and a full demonstration of the method on the remaining coating layers may be pursued as a future effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Are low-cost sensors good enough for IAQ controls?

This study used laboratory testing to evaluate low-cost (about $\$ 200$ US) IAQ monitors that measured PM2.5 to determine if they are suitable for controlling IAQ for ventilation or air cleaning systems. Current Indoor Air Quality (IAQ) standards and approaches to minimizing pollutants depend almost exclusively on using dilution with outdoor air for some generic, continuously generated contaminant (e.g., ASHRAE Standard 62.2-2016). Some standards include measurement of CO 2 (e.g., EN 13779 standard (CEN, 2007) and NEN 8088 (NEN, 2011)) – however this is not because CO 2 itself is a pollutant of concern, but rather because it can be used as an occupancy indicator or as something that correlates with bioeffluents. Ideally, we would like to measure contaminant concentrations directly and ventilate to control their concentration within acceptable limits. This would ensure that concentrations do not got too high (as they can if emission rates exceed our assumptions) and also allow for ventilation reductions, and resulting energy savings, if concentrations are low. Until recently, it was impractical to consider direct contaminant control in residential (and many commercial) spaces due to the high cost and maintenance requirements for monitoring equipment. In the past couple of years low-cost sensors have been developed for some contaminants of concern – the greatest example of which is for particles. These sensors have been incorporated into low-cost (<$250 US) IAQ monitors. Finally, this has opened up the possibility of direct control of ventilation (and filtration systems) by sensing particles. However, it is important to evaluate these monitors to determine if their results are sufficiently good to control a ventilation system.

47 OTHER INSTRUMENTATION↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Quantum Zeno Control of Superconducting Qubit Coherence

The Quantum Zeno Effect (QZE) dictates how the dynamics of a quantum system can be modified through continuous or discrete measurements [1]. It has gained increasing attention in quantum computing community in recent years, both due to its inevitable implications for qubit readout as well as for its promise for enabling new methods of quantum state control such as reservoir engineering and Zeno-dragging. Here, we investigate Zeno effects implemented via weak measurements for controlling superconducting-qubit coherence during gate and readout operations in a multi-qubit setup. Building on prior observations [2] that measurement backaction can both suppress and enhance qubit relaxation, we predict and measure QZE-altered qubit coherence times by manipulating the spectral overlap of qubit spectrum with background noise sources. We also discuss modifications and opportunities for controllable QZE due to anharmonic effects in multi-level superconducting atoms. [1] S. Greenfield, A. Kamal, J. Dressel, E. Levenson-Falk, arXiv:2506.12679 (2025) [2] Thorbeck, Z. Xiao, L. Govia, A. Kamal, Phys. Rev. Lett. 132, 090602 (2024)

Seidel, Olivia [Texas U., Arlington; Fermilab]↗