Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Method for Making Measurements of the Post-Combustion Residence Time in a Gas Turbine Engine

A system and method of measuring a residence time in a gas-turbine engine is provided, whereby the method includes placing pressure sensors at a combustor entrance and at a turbine exit of the gas-turbine engine and measuring a combustor pressure at the combustor entrance and a turbine exit pressure at the turbine exit. The method further includes computing cross-spectrum functions between a combustor pressure sensor signal from the measured combustor pressure and a turbine exit pressure sensor signal from the measured turbine exit pressure, applying a linear curve fit to the cross-spectrum functions, and computing a post-combustion residence time from the linear curve fit.

Miles, Jeffrey H↗

A Wireless Fluid-Level Measurement Technique

This paper presents the application of a recently developed wireless measurement acquisition system to fluid-level measurement. This type of fluid-level measurement system alleviates many shortcomings of fluid-level measurement methods currently being used, including limited applicability of any one fluid-level sensor design. Measurement acquisition shortcomings include the necessity for power to be supplied to each sensor and for the measurement to be extracted from each sensor via a physical connection to the sensor. Another shortcoming is existing measurement systems require that a data channel and signal conditioning electronics be dedicated to each sensor. Use of wires results in other shortcomings such as logistics needed to add or replace sensors, weight, potential for electrical arcing and wire degradations. The fluid level sensor design is a simple passive inductor-capacitor circuit that is not subject to mechanical failure that is possible when float and lever-arm systems are used. Methods are presented for using the sensor in caustic, acidic or cryogenic fluids. Oscillating magnetic fields are used to power the sensor. Once electrically excited, the sensor produces a magnetic field response. The response frequency corresponds to the amount to fluid within the capacitor s electric field. The sensor design can be modified for measuring the level of any fluid or fluent substance that can be stored in a non-conductive reservoir. The interrogation method for discerning changes in the sensor response frequency is also presented.

Woodard, Stanley E.↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large space antenna communications systems: Integrated Langley Research Center/Jet Propulsion Laboratory technology development activities. 1: Introduction

The Jet Propulsion Laboratory and the Langley Research Center have been developing technology related to large space antennas (LSA) during the past several years. The need for a communication system research program became apparent during the recent studies for the Land Mobile Satellite System. This study indicated the need for additional research in (1) electromagnetic analysis methods, (2) design and development of multiple beam feed systems, and (3) the measurement methods for LSA reflectors.

Campbell, T. G.↗

Interiors of Enceladus and Rhea

Measurement method and data set: Gravity field parameters determined by means of range rate measurements over multiple arcs across flyby. Optical imaging not required when reliable a priori estimates of spacecraft state vector are available. Interior of Enceladus: Density of 1605 +/-14 kg/cu m, higher than pre-Cassini estimates, requires a substantial amount of rock to warmer interior to enhance likelihood of differentiation of water from rock-metal. Assume no porosity. Assuming Io s mean density for the rock-metal component, one finds its fractional mass to be 0.52+/-0.06. There is evidence that Enceladus may be differentiated: a) Areas devoid of craters must be geologically young. b) Systems of ridges, fractures, and groove indicate that the surface has been tectonically altered. c) Viscous relaxation of craters has occurred, and d) The plumes near the South pole indicate venting of subsurface volatiles.

gravity fields↗

Method for Making Measurements of the Post-Combustion Residence Time in a Gas Turbine Engine

A method of measuring a residence time in a gas-turbine engine is disclosed that includes measuring a combustor pressure signal at a combustor entrance and a turbine exit pressure signal at a turbine exit. The method further includes computing a cross-spectrum function between the combustor pressure signal and the turbine exit pressure signal, calculating a slope of the cross-spectrum function, shifting the turbine exit pressure signal an amount corresponding to a time delay between the measurement of the combustor pressure signal and the turbine exit pressure signal, and recalculating the slope of the cross-spectrum function until the slope reaches zero.

Miles, Jeffrey H.↗

Fuel spray diagnostics

Several laser measurement methods are being studied to provide the capability to make droplet size and velocity measurements under a variety of spray conditions. The droplet sizing interferometer (DSI) promises to be a successful technique because of its capability for rapid data acquisition, compilation and analysis. Its main advantage is the ability to obtain size and velocity measurements in air-fuel mixing studies and hot flows. The existing DSI at NASA Lewis is a two-color, two-component system. Two independent orthogonal measurements of size and velocity components can be made simultaneously. It also uses an off-axis large-angle light scatter detection. The fundamental features of the system are optics, signal processing and data management system. The major component includes a transmitter unit, two receiver units, two signal processors, two data management systems, two Bragg cell systems, two printer/plotters, a laser, power supply and color monitor.

Bosque, M. A.↗

Rate constant for the reaction SO + BrO yields SO2 + Br

The rate of the radical-radical reaction SO + BrO yields SO2 + Br has been determined at 298 K in a discharge flow system near 1 torr pressure with detection of SO and BrO via collision-free sampling mass spectrometry. The rate constant was determined using two different methods: measuring the decay of SO radicals in the presence of an excess of BrO and measuring the decay of BrO radicals in excess SO. The results from the two methods are in reasonable agreement and the simple mean of the two values gives the recommended rate constant at 298 K, k = (5.7 + or - 2.0) x 10 to the -11th cu cm/s. This represents the first determination of this rate constant and it is consistent with a previously derived lower limit based on SO2 formation. Comparison is made with other radical-radical reactions involving SO or BrO. The reaction SO + BrO yields SO2 + Br is of interest for models of the upper atmosphere of the earth and provides a potential coupling between atmospheric sulfur and bromine chemistry.

Brunning, J.↗

Comparison between design and installed acoustic characteristics of NASA Lewis 9- by 15-foot low-speed wind tunnel acoustic treatment

The test section of the NASA Lewis 9- by 15-Foot Low-Speed Wind Tunnel was acoustically treated to allow the measurement of sound under simulated free-field conditions. The treatment was designed for high sound absorption at frequencies above 250 Hz and for withstanding the environmental conditions in the test section. In order to achieve the design requirements, a fibrous, bulk-absorber material was packed into removable panel sections. Each section was divided into two equal-depth layers packed with material to different bulk densities. The lower density was next to the facing of the treatment. The facing consisted of a perforated plate and screening material layered together. Sample tests for normal-incidence acoustic absorption were also conducted in an impedance tube to provide data to aid in the treatment design. Tests with no airflow, involving the measurement of the absorptive properties of the treatment installed in the 9- by 15-foot wind tunnel test section, combined the use of time-delay spectrometry with a previously established free-field measurement method. This new application of time-delay spectrometry enabled these free-field measurements to be made in nonanechoic conditions. The results showed that the installed acoustic treatment had absorption coefficients greater than 0.95 over the frequency range 250 Hz to 4 kHz. The measurements in the wind tunnel were in good agreement with both the analytical prediction and the impedance tube test data.

Dahl, Milo D.↗

An intercomparison of five ammonia measurement techniques

Results obtained from five techniques for measuring gas-phase ammonia at low concentration in the atmosphere are compared. These methods are: (1) a photofragmentation/laser-induced fluorescence (PF/LIF) instrument; (2) a molybdenum oxide annular denuder sampling/chemiluminescence detection technique; (3) a tungsten oxide denuder sampling/chemiluminescence detection system; (4) a citric-acid-coated denuder sampling/ion chromatographic analysis (CAD/IC) method; and (5) an oxalic-acid-coated filter pack sampling/colorimetric analysis method. It was found that two of the techniques, the PF/LIF and the CAD/IC methods, measured approximately 90 percent of the calculated ammonia added in the spiking tests and agreed very well with each other in the ambient measurements.

Williams, E. J.↗

X-Ray Diffraction (XRD) Characterization Methods for Sigma=3 Twin Defects in Cubic Semiconductor (100) Wafers

An X-ray defraction (XRD) characterization method for sigma=3 twin defects in cubic semiconductor (100) wafers includes a concentration measurement method and a wafer mapping method for any cubic tetrahedral semiconductor wafers including GaAs (100) wafers and Si (100) wafers. The methods use the cubic semiconductor's (004) pole figure in order to detect sigma=3/{111} twin defects. The XRD methods are applicable to any (100) wafers of tetrahedral cubic semiconductors in the diamond structure (Si, Ge, C) and cubic zinc-blend structure (InP, InGaAs, CdTe, ZnSe, and so on) with various growth methods such as Liquid Encapsulated Czochralski (LEC) growth, Molecular Beam Epitaxy (MBE), Organometallic Vapor Phase Epitaxy (OMVPE), Czochralski growth and Metal Organic Chemical Vapor Deposition (MOCVD) growth.

Park, Yeonjoon↗

The Prospect for Remote Sensing of Cirrus Clouds with a Submillimeter-Wave Spectrometer

Given the substantial radiative effects of cirrus clouds and the need to validate cirrus cloud mass in climate models, it is important to measure the global distribution of cirrus properties with satellite remote sensing. Existing cirrus remote sensing techniques, such as solar reflectance methods, measure cirrus ice water path (IWP) rather indirectly and with limited accuracy. Submillimeter/wave radiometry is an independent method of cirrus remote sensing based on ice particles scattering the upwelling radiance emitted by the lower atmosphere. A new aircraft instrument, the Far Infrared Sensor for Cirrus (FIRSC), is described. The FIRSC employs a Fourier Transform Spectrometer (FTS). which measures the upwelling radiance across the whole submillimeter region (0.1 1.0-mm wavelength). This wide spectral coverage gives high sensitivity to most cirrus particle sizes and allows accurate determination of the characteristic particle size. Radiative transfer modeling is performed to analyze the capabilities of the submillimeter FTS technique. A linear inversion analysis is done to show that cirrus IWP, particle size, and upper-tropospheric temperature and water vapor may be accurately measured, A nonlinear statistical algorithm is developed using a database of 20000 spectra simulated by randomly varying most relevant cirrus and atmospheric parameters. An empirical orthogonal function analysis reduces the 500-point spectrum (20 - 70/cm) to 15 "pseudo-channels" that are then input to a neural network to retrieve cirrus IWP and median particle diameter. A Monte Carlo accuracy study is performed with simulated spectra having realistic noise. The retrieval errors are low for IWP (rms less than a factor of 1.5) and for particle sizes (rins less than 30%) for IWP greater than 5 g/sq m and a wide range of median particle sizes. This detailed modeling indicates that there is good potential to accurately measure cirrus properties with a submillimeter FTS.

Evans, K. Franklin↗

Experimental results on a wall interference correction method with interface measurements

A wall interference assessment and correction method for subsonic two-dimensional wind tunnel testing is presented. This method calculates a pressure coefficient and angle of attack correction based on velocity measurements on interfaces inside of the wind tunnel. A mathematical representation of the test article is not required. An experimental verification of the suggested technique is given. A NACA 0012 airfoil is tested at a Mach number of 0.70 and at two different angles of attack. Calculated blockage corrections show reasonable agreement with results based on Hackett's method. Corrected surface pressures compare favorably to free-air flow field data if the tunnel flow field is subsonic. The present wall interference correction method can be applied to transonic tunnel flow fields with some restrictions. Errors are estimated and it is shown that the expected error in calculating the pressure coefficient correction on the model surface is in the order of the error of pressure coefficient measurement on interfaces. Necessary testing equipment in existing tunnels can easily be modified if the present method is applied.

Lo, C. F.↗

Accurately measuring the ionic conductivity of membranes via the direct contact method

Accurately measuring the ionic conductivity of membranes is important both for assessing the performance of new membranes as well as for advancing the fundamental understanding of electric field-driven ion transport in membranes. Yet, despite a considerable number of reports on the topic, there is no standardized method for ionic conductivity measurements. One of the main challenges with ionic conductivity measurements is isolating the membrane resistance from the other resistances in the electrochemical cell. In this study, we present a detailed discussion of factors that affect ionic conductivity measurements with the commonly used direct contact method, in which the membrane contacts the electrodes. Such factors include external resistances due to imperfect contact between the membrane and electrodes, residual impedances due to the sample holder and wiring, and fringe effects. Further, we also present and validate simple methods for isolating the true membrane ionic conductivity in both the through-plane and in-plane orientations. These methods can be implemented with virtually any membrane to obtain accurate and reproducible ionic conductivity values. Finally, we outline recommendations for performing ionic conductivity measurements with the direct contact method and a set of parameters to verify when reporting these results.

36 MATERIALS SCIENCE↗

Mechanical Characterization of the NIF Ignition Target TMPSA Bonding Flexure

The Thermo-Mechanical Package Sub-Assembly (TMPSA) provides a critical mechanical, thermal, and electrical interface between a silicon arm and a TMP aluminum can in a NIF ignition target. During assembly, sixteen silicon pads are bonded to the aluminum using a fixture that positions the components and applies a repeatable prescribed displacement through a compliant flexure. The flexure converts fixture interference into displacement and reaction force. Because bondline thickness variation must be maintained within +/-4 µm, consistent flexure behavior is important to the assembly process. With a recent string of TMPSAs exhibiting low bond strength, the flexures were inspected. Despite being manufactured to the same specifications, flexures were found to exhibit variation in measured stiffness. Additionally, the measured stiffness values did not always follow the presumed beam mechanics model. This work addresses two questions: whether the bonding fixture is working as intended, and whether the previously made stiffness measurements are accurate representations of the use case. The flexures are analyzed using Euler-Bernoulli beam theory, measured beam dimensions, finite element analysis, and tolerance stack-up calculations. The analysis shows that the fixed-guided beam mechanics model appropriately represents the flexure during TMPSA bonding, but the chisel-tip stiffness measurement method introduces a deformation to the inner ring of the flexure that is not represented during use. The measured stiffness values should therefore be interpreted as test-condition stiffness values rather than direct measurements of operational flexure stiffness. The discrepancy is therefore attributed primarily to the measurement boundary condition rather than to failure of the fixed-guided beam model. Recommendations are provided for GD&T, dimensional inspection, and a representative stiffness testing method to better control bondline variation.

42 ENGINEERING↗