Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Use of fractography and sectioning techniques to study fracture mechanisms

Recent investigations of the effect of microstructure on the fracture mechanisms and fracture toughness of steels, aluminum alloys, and titanium alloys have used standard fractographic techniques and a sectioning technique on specimens plastically deformed to various strains up to fracture. The specimens are prepared metallographically for observation in both optical and electron beam instruments. This permits observations to be made about the fracture mechanism as it occurs in thick sections and helps remove speculation from the interpretation of fractographic features. This technique may be used in conjunction with other standard techniques such as extraction replicas and microprobe analyses. Care must be taken to make sure that the microstructural features which are observed to play a role in the fracture process using the sectioning technique can be identified with fractography.

Van Stone, R. H.↗

Distributed Framework for Dynamic Telescope and Instrument Control

Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see httD://www.jxta.org,) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a device's IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a Principal Investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have been working with the Submillimetre High Angular Resolution Camera IInd Generation (SHARCII) at the CSO to investigate using IRC capabilities with the SHARC instrument.

Ames, Troy J.↗

The ParaScope parallel programming environment

The ParaScope parallel programming environment, developed to support scientific programming of shared-memory multiprocessors, includes a collection of tools that use global program analysis to help users develop and debug parallel programs. This paper focuses on ParaScope's compilation system, its parallel program editor, and its parallel debugging system. The compilation system extends the traditional single-procedure compiler by providing a mechanism for managing the compilation of complete programs. Thus, ParaScope can support both traditional single-procedure optimization and optimization across procedure boundaries. The ParaScope editor brings both compiler analysis and user expertise to bear on program parallelization. It assists the knowledgeable user by displaying and managing analysis and by providing a variety of interactive program transformations that are effective in exposing parallelism. The debugging system detects and reports timing-dependent errors, called data races, in execution of parallel programs. The system combines static analysis, program instrumentation, and run-time reporting to provide a mechanical system for isolating errors in parallel program executions. Finally, we describe a new project to extend ParaScope to support programming in FORTRAN D, a machine-independent parallel programming language intended for use with both distributed-memory and shared-memory parallel computers.

Cooper, Keith D.↗

Phase segregation and miscibility of TiO x nanocomposites in Gd-doped ceria solid electrolyte material

Electro-chemo-mechanical (ECM) coupling refers to mechanical deformation due to electrochemically driven compositional change in a solid. An ECM actuator producing micrometre-size displacements and long-term stability at room temperature was recently reported, comprising a 20 mol% Gd-doped ceria (20GDC), a solid electrolyte membrane, placed between two working bodies made of TiO x /20GDC (Ti-GDC) nanocomposites with Ti concentration of 38 mol%. The volumetric changes originating from oxidation or reduction in the local TiO x units are hypothesized to be the origin of mechanical deformation in the ECM actuator. Studying the Ti concentration-dependent structural changes in the Ti-GDC nanocomposites is therefore required for (i) understanding the mechanism of dimensional changes in the ECM actuator and (ii) maximizing the ECM response. Here, the systematic investigation of the local structure of the Ti and Ce ions in Ti-GDC over a broad range of Ti concentrations using synchrotron X-ray absorption spectroscopy and X-ray diffraction is reported. The main finding is that, depending on the Ti concentration, Ti atoms either form a cerium titanate or segregate into a TiO 2 anatase-like phase. The transition region between these two regimes with Ti(IV) concentration between 19% and 57% contained strongly disordered TiO x units dispersed in 20GDC containing Ce(III) and Ce(IV) and hence rich with oxygen vacancies. As a result, this transition region is proposed to be the most advantageous for developing ECM-active materials.

47 OTHER INSTRUMENTATION↗

Mitigating Scatter in Mechanical Properties in AISI 410 Fabricated via Arc-Based Additive Manufacturing Process

Wire-based metal additive manufacturing utilizes the ability of additive manufacturing to fabricate complex geometries with high deposition rates (above 7 kg/h), thus finding applications in the fabrication of large-scale components, such as stamping dies. Traditionally, the workhorse materials for stamping dies have been martensitic steels. However, the complex thermal gyrations induced during additive manufacturing can cause the evolution of an inhomogeneous microstructure, which leads to a significant scatter in the mechanical properties, especially the toughness. Therefore, to understand these phenomena, arc-based additive AISI 410 samples were fabricated using robotic gas metal arc welding (GMAW) and were subjected to a detailed characterization campaign. The results show significant scatter in the tensile properties as well as Charpy V-notch impact toughness data, which was then correlated to the microstructural heterogeneity and delta (δ) ferrite formation. Post-processing (austenitizing and tempering) treatments were developed and an ~70% reduction in the scatter of tensile data and a four-times improvement in the toughness were obtained. The changes in mechanical properties were rationalized based on the microstructure evolution during additive manufacturing. Based on these, an outline to tailor the composition of “printable” steels for tooling with isotropic and uniform mechanical properties is presented and discussed.

36 MATERIALS SCIENCE↗

Variable-Tension-Cord Suspension/Vibration-Isolation System

A system for mechanical suspension and vibration isolation of a machine or instrument is based on the use of Kevlar (or equivalent aromatic polyamide) cord held in variable tension between the machine or instrument and a surrounding frame. The basic concept of such a tensioned-cord suspension system (including one in which the cords are made of aromatic polyamide fibers) is not new by itself; what is new here is the additional provision for adjusting the tension during operation to optimize vibration- isolation properties. In the original application for which this system was conceived, the objective is to suspend a reciprocating cryocooler aboard a space shuttle and to prevent both (1) transmission of launch vibrations to the cryocooler and (2) transmission of vibrations from the cryocooler to samples in a chamber cooled by the cryocooler. The basic mechanical principle of this system can also be expected to be applicable to a variety of other systems in which there are requirements for cord suspension and vibration isolation. The reciprocating cryocooler of the original application is a generally axisymmetric object, and the surrounding frame is a generally axisymmetric object with windows (see figure). Two cords are threaded into a spoke-like pattern between attachment rings on the cryocooler, holes in the cage, and cord-tension- adjusting assemblies. Initially, the cord tensions are adjusted to at least the level necessary to suspend the cryocooler against gravitation. Accelerometers for measuring vibrations are mounted (1) on the cold tip of the cryocooler and (2) adjacent to the cage, on a structure that supports the cage. During operation, a technician observes the accelerometer outputs on an oscilloscope while manually adjusting the cord tensions in an effort to minimize the amount of vibration transmitted to and/or from the cryocooler. A contemplated future version of the system would include a microprocessor-based control subsystem that would include cord-tension actuators. This control subsystem would continually adjust the cord tension in response to accelerometer feedback to optimize vibration-isolation properties as required for various operating conditions. The control system could also adjust cord tensions (including setting the two cords to different tensions) to suppress resonances. Other future enhancements could include optimizing the cord material, thickness, and braid; optimizing the spoke patterns; and adding longitudinal cords for applications in which longitudinal stiffness and vibration suppression are required.

Villemarette, Mark L.↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LDR cryogenics

A brief summary from the 1985 Large Deployable Reflector (LDR) Asilomar 2 workshop of the requirements for LDR cryogenic cooling is presented. The heat rates are simply the sum of the individual heat rates from the instruments. Consideration of duty cycle will have a dramatic effect on cooling requirements. There are many possible combinations of cooling techniques for each of the three temperatures zones. It is clear that much further system study is needed to determine what type of cooling system is required (He-2, hybrid or mechanical) and what size and power is required. As the instruments, along with their duty cycles and heat rates, become better defined it will be possible to better determine the optimum cooling systems.

Nast, T.↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

JWST Integrated Science Instruments Module (ISIM) completed its system-level space simulation testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered to the next level of integration with the Optical Telescope Element (OTE), to form OTIS (OTE + ISIM), after concluding a series of three cryo-vacuum (CV) tests. During these tests, the complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration following mechanical environmental tests (vibration and acoustics). From one test to the next, shortcomings of the facility were uncovered and associated improvements in operational capabilities and reliability of the facility were required to enable the project to verify system-level requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

Yew, Calinda↗

Generation and injection of e.m. waves in space plasma by means of a long orbiting tether

The generation and injection of electromagnetic waves in space plasma by means of a long orbiting tether are considered. The objectives include an estimation of the portions of the primary electrodynamic power developed by the tether that goes to excite each of various wave generation and injection mechanisms expected to be present during a tether's orbital flight, an evaluation of the signal levels associated with each one of the mechanisms above, and verification of their detectability with state-of-the-art instrumentation on the Earth surface or elsewhere. The generation and injection of Alfven waves and electron whistler waves were identified as the most relevant mechanisms activited by the electrodynamic tether. The physical mechanisms that govern these two families of phenomena were investigated and the ratio between the power that goes in Alfven waves and in whistlers was derived. The analysis of the possible production of accelerated electrons by the electrodynamic tether was initiated.

Source record↗

AEROICESTUDY-Colorado State University Ice Spectrometer

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0 °C down to -26 to -29 °C) of atmospheric ice nucleating particle (INP) concentrations taken at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). A filter sampler was mounted approximately 6 m above ground level atop the GIF rooftop platform. Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm diameter Nuclepore polycarbonate filters were used. Filters were typically drawn for either a full day period (9AM-5PM CDT) or broken up into morning (9AM-12PM CDT) and afternoon (1PM-5PM CDT) periods. Additionally, 4 overnight filters were taken (6PM-8AM CDT). The volume of air filtered was typically between 3000 and 8000 standard liters for daily samples. After collection, filters were stored at -20 °C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurement of INPs, collected aerosol particles were re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples were cooled at 0.33 °C per min and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Two-tailed, 95% confidence intervals for binomial sampling were based on Equation 2 from Agresti and Coull (1998). Aliquots of suspensions from selected samples were also heat treated (95 °C for 20 min) to denature and deactiv

54 ENVIRONMENTAL SCIENCES↗

A Low Mass Translation Mechanism for Planetary FTIR Spectrometry using an Ultrasonic Piezo Linear Motor

One of the key components of a Fourier Transform Infrared Spectrometer (FTIR) is the linear translation stage used to vary the optical path length between the two arms of the interferometer. This translation mechanism must produce extremely constant velocity motion across its entire range of travel to allow the instrument to attain high signal-to-noise ratio and spectral resolving power. A new spectrometer is being developed at the Jet Propulsion Laboratory under NASA s Planetary Instrument Definition and Development Program (PIDDP). The goal of this project is to build upon existing spaceborne FTIR spectrometer technology to produce a new instrument prototype that has drastically superior spectral resolution and substantially lower mass, making it feasible for planetary exploration. In order to achieve these goals, Alliance Spacesystems, Inc. (ASI) has developed a linear translation mechanism using a novel ultrasonic piezo linear motor in conjunction with a fully kinematic, fault tolerant linear rail system. The piezo motor provides extremely smooth motion, is inherently redundant, and is capable of producing unlimited travel. The kinematic rail uses spherical Vespel(R). rollers and bushings, which eliminates the need for wet lubrication, while providing a fault tolerant platform for smooth linear motion that will not bind under misalignment or structural deformation. This system can produce velocities from 10 - 100 mm/s with less than 1% velocity error over the entire 100-mm length of travel for a total mechanism mass of less than 850 grams. This system has performed over half a million strokes under vacuum without excessive wear or degradation in performance. This paper covers the design, development, and testing of this linear translation mechanism as part of the Planetary Atmosphere Occultation Spectrometer (PAOS) instrument prototype development program.

Heverly, Matthew↗

Vertical distribution of boundary layer new particle formation and implications for nanoparticle growth mechanisms (Final Report)

New particles can form high above ground in the atmosphere before such formation events are observed by ground-based instruments. Once formed, these particles can take up significant amounts of water vapor, which has implications on the mechanisms by which nanoparticles grow and, ultimately, impact cloud formation processes. These observations motivated the research performed in this project using a combination of modeling, laboratory experiments, and the analysis of field observations. We hypothesized is that ground-based measurements do not always accurately represent the location and timing of new particle formation events, nor do they adequately characterize the dominant physical and chemical processes that are responsible for the subsequent growth of newly formed particles. Essentially, we wanted to study the new particle formation process under conditions that we expect may be more relevant to the actual location in the atmosphere where such events take place, which are often characterized by higher relative humidities, lower temperatures, and a broader range of precursors and oxidants compared to those observed at ground level. This project had two main objectives, each of which directly addressed our hypothesis. Our first is to investigate the timing, distribution, meteorological conditions, and nanoparticle properties associated with boundary layer new particle formation through the analysis of ARM field campaigns such as HI-SCALE and long-term observations and observations performed in other locales such as in China and India where atmospheric conditions could play a crucial role in determining the mechanisms of new particle formation. This activity provided a comprehensive description, both in time and in space, of the gases and nanoparticle properties that are responsible for these events. We also performed modeling studies to explore the vertical profile and timing of new particle formation events from these campaigns. Our second objective was to perform laboratory and process-level modeling studies to investigate the role that conditions such as low ambient temperature, high relative humidity, and different oxidants such as nitrate radical play in determining unique chemical pathways for nanoparticle growth. In doing so, we revisited the representation of nanoparticle growth in global models and updated assumptions of formation and growth based on the findings of the field, laboratory, and process-level-model work. Our research provides crucial insights into the most important regions of the atmospheric boundary layer for future observational and modeling studies. It also identifies the most relevant environmental conditions, precursors, and oxidants that are responsible for nanoparticle growth, which will aid in the design of laboratory studies and process-level model experiments. The unique pathways that we discovered can be incorporated into regional and global models, thereby improving predictions and attribution of the role of new particle formation in, e.g., air pollution formation and cloud properties.

54 ENVIRONMENTAL SCIENCES↗

Platinum nanoparticle compression: Combining in situ TEM and atomistic modeling

The mechanical behavior of nanoparticles governs their performance and stability in many applications. However, the small sizes of technologically relevant nanoparticles, with diameters in the range of 10 nm or less, significantly complicate experimental examination. These small nanoparticles are difficult to manipulate onto commercial test platforms and deform at loads that are below the typical noise floor of the testing instruments. Here, we synthesized small platinum nanoparticles directly onto a mechanical tester and used a modified nanomanipulator to enhance load resolution to the nanonewton scale. We demonstrated the in situ compression of an 11.5-nm platinum nanoparticle with simultaneous high-resolution measurements of load and particle morphology. Molecular dynamics simulations were performed on similarly sized particles to achieve complementary measurements of load and morphology, along with atomic resolution of dislocations. The experimental and simulation results revealed comparable values for the critical resolved shear stress for failure, 1.28 and 1.15 GPa, respectively. Altogether, this investigation demonstrated the promise of, and some initial results from, the combination of atomistic simulations and in situ experiments with an unprecedented combination of high spatial resolution and high load resolution to understand the behavior of metal nanoparticles under compression.

42 ENGINEERING↗

Design of a Loss of Coolant Blowdown Capsule for Remote Assembly with High Burnup Fuel

The Transient Water Irradiation System is an enhanced capability capsule type irradiation vehicle designed to support fuel safety research for light water reactor specimens in the Transient Reactor Test Facility and is designed to simulate loss of coolant and reactivity-initiated accidents. The capsule was designed, deployed, and commissioned with fresh fuel specimens to validate instrumentation and prepare for previously irradiated high burnup specimens. The irradiation system features an extensive in-situ instrumentation package to detect phenomena typical to light water reactor fuels. To accommodate the assembly with high burnup specimens inside the Hot Fuel Examination Facility, and to ensure instrumentation integrity is maintained throughout assembly, the design was updated to support remote handling. The updated design features a hinge mechanism which allows for remote pre-irradiated specimen loading and assembly while protecting sensitive instrumentation by relocating during loading. Fixtures and equipment have been developed to handle the experiment capsule and components in cell, and to support remote assembly. The experiment module also includes radiation shielding and contamination control to support operations after removal from the hot cell.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗