Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods and Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Impacts of Biofuel Blending on MCCI Ignition Delay with Review of Methods for Defining Cycle-by-Cycle Ignition Points from Noisy Cylinder Pressure Data: Preprint

Conventional diesel combustion, also known as Mixing-Controlled Compression Ignition (MCCI), is expected to be the primary power source for medium- and heavy-duty vehicles for decades to come. Displacing petroleum-based ultra-low-sulfur diesel (ULSD) as much as possible with low-net-carbon biofuels will become necessary to help mitigate effects on climate change. Neat biofuels may have difficulty meeting current diesel fuel standards but blends of 30% biofuel in ULSD show potential as ‘drop-in’ fuels. These blends must not make significant changes to the combustion phasing of the MCCI process if they are to be used interchangeably with neat ULSD. An important aspect of MCCI phasing is the ignition delay (ID), i.e. the time between the start of fuel injection and the initial premixed autoignition that initiates the MCCI process. Bench experiments can evaluate the expected ignition delay of a fuel via cetane number (CN) or alternative methods such as the indicated cetane number (ICN); however, neither CN nor ICN correlate perfectly with the ignition delay measured in actual engine experiments. Furthermore, there is no standardized methodology on how to quantify MCCI ignition delay from engine cylinder pressure measurements, creating difficulties in cross-study comparison. In this study, several engine ignition delay calculation methods are evaluated for robustness in deriving ignition delay on both a cycle-averaged and cycle-to-cycle basis. Eight biofuel blends with varying ICN, oxygen concentration and other fuel properties were used to study the different methods. This yields a thorough analysis of how certain biofuel blends affect ignition delay and the entire MCCI process, as well as a thorough evaluation of the differences between the ID calculation methods. Many of these methods are equally valid, but the choice of method has a significant impact on the resulting ID, which must be carefully considered when evaluating results across multiple studies.

47 OTHER INSTRUMENTATION↗

The eXtended virtual element method for elliptic problems with weakly singular solutions

This paper introduces a novel eXtended virtual element method, an extension of the conforming virtual element method. The X-VEM is formulated by incorporating appropriate enrichment functions in the local spaces. The method is designed to handle highly generic enrichment functions, including singularities arising from fractured domains. By achieving consistency on the enrichment space, the method is proven to achieve arbitrary approximation orders even in the presence of singular solutions. The paper includes a complete convergence analysis under general assumptions on mesh regularity, and numerical experiments validating the method’s accuracy on various mesh families, demonstrating optimal convergence rates in the L 2 - and H 1 - norms on fractured or L-shaped domains.

97 MATHEMATICS AND COMPUTING↗

Geant4 and beyond: recent progress in precision physics modeling - Paper 100

This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Vision-based inspection of prefabricated components using camera poses: Addressing inherent limitations of image-based 3D reconstruction

Modular construction can lead to additional cost overruns and delays when a defect is found on the construction site and is not easily repairable. Researchers have developed various methods that use image-based 3D reconstruction for quality assessment, but they have inherent limitations, such as inconsistency and dealing with surfaces with reflectivity and limited visual features. Therefore, this paper presents a vision-based quality assessment method using cameras for prefabricated components by addressing these limitations. Specifically, this paper proposes a novel quality inspection method with sub-millimeter accuracy using cameras focused on leveraging camera poses (as opposed to 3D point clouds that are often not consistent in quality) from the image-based 3D reconstruction. The 3D point estimation by computing triangulation was used for achieving accurate measurement. The proposed method is validated using six different variances and two case studies – an aluminum pipe with a reflective surface and a fabricated concrete column. Furthermore, the results demonstrate the accuracy and effectiveness of the proposed method.

42 ENGINEERING↗

Integration of Photovoltaics into Building Energy Usage through Advanced Control of Rooftop Unit

This paper presents a computational approach to forecast photovoltaic (PV) power in kW based on a neural network linkage of publicly available cloud cover data and on-site solar irradiance sensor data. We also describe a control approach to utilize rooftop air conditioning units (RTUs) to support renewable integration. The PV forecasting method is validated using data from a rooftop PV panel installed on the Distributed Energy, Communications, and Controls (DECC) laboratory at Oak Ridge National Laboratory. The validation occurs in multiple phases to ensure that each component of the approach is the best representation of the actual expected output. The control of the RTU is based on model predictive methods.

Starke, Michael R↗

The 2019 Edition of the IRPhEP Handbook

The International Reactor Physics Experiment Evaluation Project (IRPhEP) [1] was established to preserve and evaluate integral reactor physics experiment data, including separate or special effects measurements for nuclear energy and technology applications. Numerous international experiments have been performed over the past several decades to support reactor operations, safety, measurements, and design. Those experiments represent a significant investment of infrastructure, cost, and expertise that, in many instances, cannot be as easily reproduced. They represent valuable resources of data for present and future research, and provide the basis for recording, development, and validation of methods [2]. The primary focus of the IRPhEP is to provide an extensively peer-reviewed set of reactor physics integral data suitable for reactor designers and safety analysts to not just validate the analytical tools necessary to design next-generation nuclear reactors, but to establish the safety basis for their operation. Contributors worldwide collaborate to evaluate and review selected benchmark experiments for inclusion in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook) [3]. More detailed discussion of the IRPhEP, including highlighted reactor physics benchmark evaluations, can be found in the November and December 2014 editions of Nuclear Science and Engineering [1]. Several new evaluations, and revisions to existing benchmarks have been prepared for inclusion in the 2019 edition of the IRPhEP Handbook (see Table I).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operando Freezing Cryogenic Electron Microscopy of Active Battery Materials

Abstract Understanding structural and chemical evolution of battery materials during operation is critical to achieving safe, efficient, and long-lasting energy storage. Cryogenic electron microscopy (cryo-EM) has become a valuable tool in battery characterization, leveraging low temperatures to improve stability of sensitive materials under electron beam irradiation. However, typical cryo-EM sample preparations leave extended time between the electrochemical point of interest and ex situ freezing of samples, during which active structures may relax, degrade, or otherwise evolve. Here, we detail a method for operando freezing cryo-EM to preserve and characterize native electrode and interfacial structures that arise during battery cycling, based on an operando plunge freezer and cold sample removal process. We validate the method on multiple electrode materials and quantify and discuss the freezing rate achieved. Operando freezing cryo-EM can be used to directly visualize transient features that arise at active electrochemical interfaces, to enable deeper understanding of structural evolution and interfacial chemistry in batteries and other electrochemical systems.

25 ENERGY STORAGE↗

An Inrush Current Limit Method for SiC-based Multi-level Grid-connected Converter During Low-Voltage Ride-Through

Low-voltage ride-through is one of the grid requirements for grid-connected converters, and during the transient of grid voltage change, a large inrush current could be induced due to the control delay of the converter. This inrush current is more severe in SiC-based multi-level converters due to the small filter inductance, which is selected based on harmonics consideration. In this paper, a PWM mask method is used to limit the inrush current of a cascaded H-bridge-based grid-connected converter during the transient of grid voltage change. Simulation and experiment results are provided to validate this method.

Li, Haiguo↗

The Poor Academic’s DC-Offset for Reversing Polarity in Electrochemical Cells: Application to Redox Flow Cells

We provide a simple and inexpensive manual DC-offset method for extending the accepted voltage range of a battery cycler to negative voltages, without interfering with the actual operation of the electrochemical cell under the test or exceeding the voltage specs of the battery cycler instrument. We describe the working principles of the method and validate the proposed setup by operating short-term and long-term redox flow battery cycling using compositionally symmetric cell, with open-circuit voltage of zero, and full cell configurations. The method can be used to extend the capability of battery cycler instrumentation to operate any electrochemical cell that requires the polarity to be reversed during operation. Applications include cycling of other symmetric cells (e.g., Li-ion cells), implementation of polarity reversal steps for rejuvenation of electroactive species or rebalancing electrochemical cells, and alternating polarity for electrochemical synthesis.

25 ENERGY STORAGE↗

Spectral Transfer Learning Using Information Geometry for a User-Independent Brain-Computer Interface

Recent advances in signal processing and machine learning techniques have enabled the application of Brain-Computer Interface (BCI) technologies to fields such as medicine, industry, and recreation; however, BCIs still suffer from the requirement of frequent calibration sessions due to the intra- and inter-individual variability of brain-signals, which makes calibration suppression through transfer learning an area of increasing interest for the development of practical BCI systems. In this paper, we present an unsupervised transfer method (spectral transfer using information geometry,STIG),which ranks and combines unlabeled predictions from an ensemble of information geometry classifiers built on data from individual training subjects. The STIG method is validated in both off-line and real-time feedback analysis during a rapid serial visual presentation task (RSVP). For detection of single-trial, event-related potentials (ERPs), the proposed method can significantly outperform existing calibration-free techniques as well as out perform traditional within-subject calibration techniques when limited data is available. Here, this method demonstrates that unsupervised transfer learning for single-trial detection in ERP-based BCIs can be achieved without the requirement of costly training data, representing a step-forward in the overall goal of achieving a practical user-independent BCI system.

60 APPLIED LIFE SCIENCES↗

Performance analysis of Wald-statistic based network detection methods for radiation sources

There have been increasingly large deployments of radiation detection networks that require computationally fast algorithms to produce prompt results over ad-hoc sub-networks of mobile devices, such as smart-phones. These algorithms are in sharp contrast to complex network algorithms that necessitate all measurements to be sent to powerful central servers. In this work, at individual sensors, we employ Wald-statistic based detection algorithms which are computationally very fast, and are implemented as one of three Z-tests and four chi-square tests. At fusion center, we apply the K-out-of-N fusion to combine the sensors hard decisions. We characterize the performance of detection methods by deriving analytical expressions for the distributions of underlying test statistics, and by analyzing the fusion performances in terms of K, N, and the false-alarm rates of individual detectors. We experimentally validate our methods using measurements from indoor and outdoor characterization tests of the Intelligence Radiation Sensors Systems (IRSS) program. In particular, utilizing the outdoor measurements, we construct two important real-life scenarios, boundary surveillance and portal monitoring, and present the results of our algorithms.

Sen, Satyabrata↗

SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previously developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Novel Selectivity-Based Forensic Toxicological Validation of a Paper Spray Mass Spectrometry Method for the Quantitative Determination of Eight Amphetamines in Whole Blood

Paper spray tandem mass spectrometry is used to identify and quantify eight individual amphetamines in whole blood in 1.3 min. The method has been optimized and fully validated according to forensic toxicology guidelines, for the quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methylamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxymethamphetamine (PMMA), and 4-fluoroamphetamine (4-FA). Additionally, a new concept of intrinsic and application-based selectivity is discussed, featuring increased confidence in the power to discriminate the amphetamines from other chemically similar compounds when applying an ambient mass spectrometric method without chromatographic separation. Accuracy was within ±15% and average precision was better than 15%, and better than 20% at the LLOQ. Detection limits between 15 and 50 ng/mL were obtained using only 12 μL of whole blood. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal-to-noise assessment for diffusion tensor imaging with single data set and validation using a difference image method with data from a multicenter study

Purpose: To describe a quantitative method for determination of SNR that extracts the local noise level using a single diffusion data set. Methods: Brain data sets came from a multicenter study (eight sites; three MR vendors). Data acquisition protocol required b = 0, 700 s/mm{sup 2}, fov = 256 × 256 mm{sup 2}, acquisition matrix size 128 × 128, reconstruction matrix size 256 × 256; 30 gradient encoding directions and voxel size 2 × 2 × 2 mm{sup 3}. Regions-of-interest (ROI) were placed manually on the b = 0 image volume on transverse slices, and signal was recorded as the mean value of the ROI. The noise level from the ROI was evaluated using Fourier Transform based Butterworth high-pass filtering. Patients were divided into two groups, one for filter parameter optimization (N = 17) and one for validation (N = 10). Six white matter areas (the genu and splenium of corpus callosum, right and left centrum semiovale, right and left anterior corona radiata) were analyzed. The Bland–Altman method was used to compare the resulting SNR with that from the difference image method. The filter parameters were optimized for each brain area, and a set of “global” parameters was also obtained, which represent an average of all regions. Results: The Bland–Altman analysis on the validation group using “global” filter parameters revealed that the 95% limits of agreement of percent bias between the SNR obtained with the new and the reference methods were −15.5% (median of the lower limit, range [−24.1%, −8.9%]) and 14.5% (median of the higher limits, range [12.7%, 18.0%]) for the 6 brain areas. Conclusions: An FT-based high-pass filtering method can be used for local area SNR assessment using only one DTI data set. This method could be used to evaluate SNR for patient studies in a multicenter setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast permeability measurement for tight reservoir cores using only initial data of the one chamber pressure pulse decay test

Here, in this study, a mathematical model for fast determination of the permeabilities of tight rocks using measurements taken from the initial period of the One Chamber Pressure Pulse Decay (OC-PPD) test is presented. The model applies to measurements taken both before and after the pressure pulse front has reached the downstream end of the specimen. The analytical solutions for the pressure decay in the upstream chamber are derived based on a parabolic arc approximation of pore pressure distribution along the test specimen. This approximation allows converting the initial–boundary value problem of fluid diffusion in the specimen, governed by partial differential equations, to a system of ordinary differential equations that can be easily solved by explicit formulae. Thus, an explicit formula for the pressure decay rate is obtained, which enables inverse analysis of the initial experimental data to estimate the rock permeability. The proposed method expedites the pulse decay test as it does not require the system to reach equilibrium. The method is validated with three sets of experimental data of the OC-PPD test using helium as the diffusing fluid, for which the relative error of the permeability is found to be less than 6%. This method is particularly useful if the equilibrium time of the pulse decay test for rock specimens with permeabilities in the range of nano-Darcy takes hours or days.

early-time solution↗

Effect of Nucleation Heterogeneity on Mineral Precipitation in Confined Environments

Abstract The formation of new mineral phases in confined environments, especially in porous media, is crucial for various geological processes like mineralization and diagenesis. The nucleation and precipitation of minerals are initiated at the microscale through fluid‐rock interaction, where dissolution of primary phases leads to supersaturated conditions and nucleation and growth of secondary ones. Previous research has focused primarily on either precipitation or nucleation, without fully exploring their combined impact. Our study introduces a computational framework that integrates classical nucleation theory with the micro‐continuum method. We validated our model by comparing with experiments, and discovered that different surface nucleation rate changes the mode of precipitation from a preferential to uniform precipitate textures. Furthermore, our study uncovered that the conventional deterministic precipitation method tends to underestimate the permeability of the porous matrix. In contrast, the new framework significantly improves model accuracy by incorporating preferential precipitation and heterogeneous nucleation.

58 GEOSCIENCES↗

Classifying supernovae using only galaxy data

We present a new method for probabilistically classifying supernovae (SNe) without using SN spectral or photometric data. Unlike all previous studies to classify SNe without spectra, this technique does not use any SN photometry. Instead, the method relies on host-galaxy data. We build upon the well-known correlations between SN classes and host-galaxy properties, specifically that core-collapse SNe rarely occur in red, luminous, or early-type galaxies. Using the nearly spectroscopically complete Lick Observatory Supernova Search sample of SNe, we determine SN fractions as a function of host-galaxy properties. Using these data as inputs, we construct a Bayesian method for determining the probability that an SN is of a particular class. This method improves a common classification figure of merit by a factor of >2, comparable to the best light-curve classification techniques. Of the galaxy properties examined, morphology provides the most discriminating information. We further validate this method using SN samples from the Sloan Digital Sky Survey and the Palomar Transient Factory. We demonstrate that this method has wide-ranging applications, including separating different subclasses of SNe and determining the probability that an SN is of a particular class before photometry or even spectra can. Since this method uses completely independent data from light-curve techniques, there is potential to further improve the overall purity and completeness of SN samples and to test systematic biases of the light-curve techniques. Further enhancements to the host-galaxy method, including additional host-galaxy properties, combination with light-curve methods, and hybrid methods, should further improve the quality of SN samples from past, current, and future transient surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic Loss Factor Modeling and Attribution on Unlabeled PV Energy Data

We present a novel approach for modeling the loss factors of photovoltaic power generation systems (PV systems). This method is a white-box machine learning model built on convex optimization that is fast, interpretable, and auditable. It takes as an input the measured daily energy produced by the system, over a multi-year period, and returns a multiplicative decomposition model of the daily energy signal and full attribution of the total energy loss to each feature. The methods section of this paper has two major components: (1) the description of the signal decomposition (SD) model, expressed in the SD framework, and (2) the attribution of total energy losses via Shapley values. We validate the method on synthetic and open-source data sets and compare to similar methods from the literature.

artificial intelligence↗