Offline Arterial Signal Timing Optimization for Closely Spaced Intersections

The stop-and-go driving behavior at a busy arterial causes a significant amount of fuel waste and emissions that could be reduced. For closely spaced intersections, the traditional bottom-up signal timing approach could fail under high volumes when the queues reach the upstream intersections. A well-coordinated arterial should manage the queue length to prevent the control from failing. Traditionally, coordination among signalized intersections for an arterial means finding the good offsets for each intersection. The control of the intersections along an arterial can also be coordinated by optimizing splits. Splits impact the capacity of an intersection. Similar to the highway, the capacity drop could cause growing queues. This work is based on the Virtual Phase-Link (VPL) model, a street traffic model designed for online traffic model predictive control, to obtain a top-down offline arterial signal timing. The VPL-based model can guarantee capacity consistency in intersections along an arterial. We, therefore, adopted the VPL-based model and developed an offline signal timing optimization approach. The proposed timing derived from the VPL-based offline signal timing optimization showed very good results in simulation. We also collected field experiment data, which demonstrated overall energy reductions and speed improvements on some sections of the study arterial.

47 OTHER INSTRUMENTATION↗

Efficient and Collision-Free Anticipative Cruise Control in Randomly Mixed Strings

Connected intelligent vehicle following can improve safety and efficiency compared to today's road transport, but real traffic in the near future will not provide an ideal setting for its deployment. Unconnected human-driven vehicles will follow variable behavior patterns that combine with differences in dynamic capability to create heterogeneous scenarios. In this paper, connected automated vehicles employ model predictive control for following in traffic that may include both heavy and passenger vehicles at quasi-random positions. Adding further realism, some quasi-randomly mixed vehicles are completely unconnected and equipped with the reactive intelligent driver model using pseudorandom parameters. A mixed-integer quadratic programming formulation adapts the predictive algorithm to diverse powertrain operating point constraints. The preceding vehicle's control input is estimated from velocity and brake light observations and used to probabilistically generate a preview for the ego vehicle. Here, a terminal constraint designed using particle kinematics prevents collisions due to shortsightedness. Results are simulated at various heavy and predictive vehicle concentrations in the presence of packet loss. Linear fuel economy improvements between 1.4% and 1.9% per 10% increase in predictive vehicle penetration rate are shown.

33 ADVANCED PROPULSION SYSTEMS↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coordination of Energy Storage and Distributed Generation for Voltage Control and Peak-valley Filling

The increasing penetration of distributed energy resources (DERs) in distribution network (DN) poses challenges on voltage control. In addition, the growing integration of DERs also reshapes the traditional load profile. To comprehensively address the voltage control and peak-valley filling in DN, this paper proposes a model predictive control (MPC) based optimization framework. The proposed method can achieve coordinated voltage control and peak-valley filling by adjusting the reactive power output from distributed generations (DGs) and the charging/discharging of energy storage systems (ESS). The performance of the proposed method is demonstrated by simulations on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Distributed Frequency Control of Prosumer-Based Electric Energy Systems

In this paper, we propose a distributed frequency regulation framework for prosumer-based electric energy systems, where a prosumer (producer-consumer) is defined as an intelligent agentwhich can produce, consume, and/or store electricity. Despite the frequency regulators being distributed, stability can be ensured while avoiding inter-area oscillations using a limited control effort. To achieve this, a fully distributed one-step model-predictive control protocol is proposed and analyzed, whereby each prosumer communicates solely with its neighbors in the network. The efficacy of the proposed frequency regulation framework is shown through simulations on two real-world electric energy systems of different scale and complexity. We show that prosumers can indeed bring frequency and power deviations to their desired values after small perturbations.

Nazari, MH↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

Trajectory Shaper: A Solution for Disrupted Cooperative Adaptive Cruise Control

Cooperative adaptive cruise control (CACC) can effectively reduce energy consumption, alleviate traffic congestion, and enhance safety. However, communication-related constraints and uncooperative vehicle users can disrupt CACC during real-world operations, significantly undermining the putative benefits of CACC. To alleviate the negative impacts of disrupted CACC, this study develops the trajectory shaper (TS) methods as backup solutions for two scenarios: (i) communication between vehicles is infeasible, and vehicles execute adaptive cruise control (ACC) using local sensor measurements; (ii) follower vehicles reject forming a cooperative platoon and execute their local distributed controllers using the information attained via communication. When communication is infeasible, a distributed TS is devised on each vehicle to modify the sensor measurements, enabling safe and efficient ACC operations. When communication is available but uncooperative agents are involved, the lead vehicle of the platoon executes a centralized TS to modify the information shared with uncooperative agents, achieving optimal platoon-level performance. The centralized and distributed TSs are implemented based on the model predictive control algorithms to yield optimal modifications on input information. Robustness is also factored to tackle model uncertainties during TS operations to ensure safety and efficiency. Numerical experiments validate the control performance of the proposed TSs.

Zhou, Anye [ORNL] (ORCID:0000000301455579)↗

Resonance Suppression based on Predictive Control of Grid-following Inverters with LCL Filter in Weak Grid Condition

This paper presents an effective resonance suppression control when grid interactive inverter with LCL filter experience weak grid conditions. The resonance suppression mechanism is based on finite-set model predictive control (FSMPC) with adaptive cost function to alter the controller objectives seamlessly. The large parasitic impedance and low short circuit ratio (SCR) of weak grid challenges the operation of gridconnected inverters. Specifically, the LCL filter resonance may get excited, resulting in collapse of the inverter operation. To address this issue, an effective active damping approach is implemented in the proposed control. In the proposed active damping scheme for resonance suppression, the feedback currents are switched based on the operating conditions of inverter. During the stiff grid conditions, grid current serves as feedback to the controller. While in the weak grid conditions, the inverter current is selected as feedback signal. The toggling action between these two feedback currents is determined by comparing moving RMS of grid current with threshold current as constraint in the cost function of the proposed MPC scheme. The threshold current for toggling action is based on the reference active and reactive power setpoints plus an acceptable band of variation. The theoretical analysis is verified by several case studies.

Umar, Muhammad Farooq↗

Time-Varying Output Delay Compensation-A Model-Free Approach and its Application on Cooperative On-Ramp Merging

This paper presents a model-free approach to compensate for time-varying output delay in networked control systems. The proposed architecture combines a model-free observer and the Smith predictor. The model-free observer estimates the current state while handling modeling errors and uncertainties of the system. The Smith predictor moves the effect of time delay outside the control closed-loop using the estimated delayed output and the actual output of the plant. The proposed method is applied to a cooperative on-ramp merging problem. First, an ultra-local model predictive control is implemented to provide a computationally efficient online speed planner agnostic to the vehicle dynamics. After that, a model-free observer is designed to estimate the current state. Finally, the proposed architecture is tested against a time-varying output delay with an upper bound of 200 milliseconds. The results demonstrate the effectiveness of the proposed method with improved tracking of intervehicle distance.

Waleed khan, Muhammad [The University of Texas at ↗

Distributed MPC for Efficient Coordination of Storage and Renewable Energy Sources Across Control Areas

In electric power systems, multiple entities are responsible for ensuring an economic and reliable way of delivering power from producers to consumers. With the increase of variable renewable generation it is becoming increasingly important to take advantage of the individual entities' (and their areas') capabilities for balancing variability. Hence, in this paper, we employ and extend the approximate Newton directions method to optimally coordinate control areas leveraging storage available in one area to balance variable resources in another area with only minimal information exchange among the areas. The problem to be decomposed is a model predictive control problem including generation constraints, energy storage constraints, and AC power flow constraints. Singularity issues encountered when formulating the respective Newton-Raphson steps due to intertemporal constraints are addressed and extensions to the original decomposition method are proposed to improve the convergence rate and required communication of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Deep Reinforcement Learning Algorithm for Distribution System Cyber Attack Defense With High Penetration of DERs

With grid modernization, smart inverters are increasingly used to execute advanced controls for distribution network reliability. However, this also increases the cyber-attack space. Here this paper focuses on the defense approaches to restore the system to normal operation circumstances in the presence of cyber-attacks. A unique deep reinforcement learning (DRL) method is developed to minimize voltage violations and reduce power losses for impacted feeders. The defense problem is reformulated as a Markov decision-making process to dynamically control DERs while minimizing load shedding. This is achieved via an improved soft actor-critic (SAC)-based DRL algorithm, which can govern DER set points and load-shedding scenarios in discrete and continuous modes via the auto-tune entropy and Gaussian policy features. Numerical comparison results on the modified IEEE 123-node system with other control approaches, such as Volt-VAR (VV), Volt-Watt (VW), and model predictive control (MPC) show that the proposed method can eliminate voltage violations and provide feasible control actions that perform complete mitigation of cyber-threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Nonlinear Subspace Modeling for Prediction and Control of Molten Iron Quality Indices in Blast Furnace Ironmaking

Blast furnace (BF) in ironmaking is a nonlinear dynamic process with complicated physical-chemical reactions, where multi-phase and multi-field coupling and large time delay occur during its operation. In BF operation, the molten iron temperature (MIT) as well as Si, P and S contents of molten iron are the most essential molten iron quality (MIQ) indices, whose measurement, modeling and control have always been important issues in metallurgic engineering and automation field. This paper develops a novel data-driven nonlinear state space modeling for the prediction and control of multivariate MIQ indices by integrating hybrid modeling and control techniques. First, to improve modeling efficiency, a data-driven hybrid method combining canonical correlation analysis and correlation analysis is proposed to identify the most influential controllable variables as the modeling inputs from multitudinous factors would affect the MIQ indices. Then, a Hammerstein model for the prediction of MIQ indices is established using the LS-SVM based nonlinear subspace identification method. Such a model is further simplified by using piecewise cubic Hermite interpolating polynomial method to fit the complex nonlinear kernel function. Compared to the original Hammerstein model, this simplified model can not only significantly reduce the computational complexity, but also has almost the same reliability and accuracy for a stable prediction of MIQ indices. Last, in order to verify the practicability of the developed model, it is applied in designing a genetic algorithm based nonlinear predictive controller for multivariate MIQ indices by directly taking the established model as a predictor. Industrial experiments show the advantages and effectiveness of the proposed approach.

Blast furnace (BF)↗

Online data-enabled predictive control

We develop an online data-enabled predictive (ODeePC) control method for optimal control of unknown systems, building on the recently proposed DeePC (Coulson et al., 2019). Our proposed ODeePC method leverages a primal-dual algorithm with real-time measurement feedback to iteratively compute the corresponding real-time optimal control policy as system conditions change. The proposed ODeePC conceptual-wise resembles standard adaptive system identification and model predictive control (MPC), but it provides a new alternative for the standard methods. ODeePC is enabled by computationally efficient methods that exploit the special structure of the Hankel matrices in the context of DeePC with Fast Fourier Transform (FFT) and primal-dual algorithm We provide theoretical guarantees regarding the asymptotic behavior of ODeePC, and we demonstrate its performance through numerical examples.

97 MATHEMATICS AND COMPUTING↗

Learning Constrained Parametric Differentiable Predictive Control Policies With Guarantees

We present differentiable predictive control (DPC), a method for offline learning of constrained neural control policies for nonlinear dynamical systems with performance guarantees. We show that the sensitivities of the parametric optimal control problem can be used to obtain direct policy gradients. Specifically, we employ automatic differentiation (AD) to efficiently compute the sensitivities of the model predictive control (MPC) objective function and constraints penalties. To guarantee safety upon deployment, we derive probabilistic guarantees on closed-loop stability and constraint satisfaction based on indicator functions and Hoeffding’s inequality. We empirically demonstrate that the proposed method can learn neural control policies for various parametric optimal control tasks. In particular, we show that the proposed DPC method can stabilize systems with unstable dynamics, track time-varying references, and satisfy nonlinear state and input constraints. Our DPC method has practical time savings compared to alternative approaches for fast and memory-efficient controller design. Specifically, DPC does not depend on a supervisory controller as opposed to approximate MPC based on imitation learning. We demonstrate that, without losing performance, DPC is scalable with greatly reduced demands on memory and computation compared to implicit and explicit MPC while being more sample efficient than model-free reinforcement learning (RL) algorithms.

97 MATHEMATICS AND COMPUTING↗

Comparison of MPC Formulations for Building Control under Commercial Time-of-Use Tariffs

© 2019 IEEE. Most medium and large commercial buildings in the U.S. are subject to complex electricity tariffs that combine both Time-of-Use (TOU) energy and demand charges. This study analyses the performances of different economic Model Predictive Control (MPC) formulations, from the standpoints of monthly bill reduction, load shifting, and peak demand reduction. Simulations are performed on many simplified commercial building models, with multiple TOU demand charges, and under various summer conditions. Results show that compared to energy-only MPC, the traditional method for dealing with demand charges significantly reduces peak demand and owner bill, however, highlight a lack of load shifting capability. A proposed incremental approach is presented, which better balances the bill components in the objective function. In the case study presented, this method can improve monthly bill savings and increase load shifting during demand response events, while keeping a similarly low peak demand, compared to traditional MPC methods taking into account demand charges.

Cutsem, Olivier Van↗

Biomimetic model-based advanced control strategy integrated with multi-agent optimization for nonlinear chemical processes

Here, a novel framework is proposed for integrating biomimetic-based advanced control and multi-agent optimization approaches for nonlinear chemical process applications. In particular, a Biologically-Inspired Optimal Control Strategy, denoted as BIO-CS, is combined with multi-agent optimization (MAO) techniques to provide optimal solutions for dynamic systems. In this combined framework, the BIO-CS algorithm employs gradient-based optimal control solvers for the intermediate problems associated with the leader-follower agents’ local interactions. Also, the MAO uses the capabilities of heuristic-based optimization techniques by sharing process information to obtain optimal operating setpoints for the controller considering an overall process objective. The applicability of the proposed method is demonstrated using a nonlinear, multivariable, process model of a fermentation system. Specifically, the optimal operating points are computed by the MAO implementation for setpoint tracking, trajectory tracking and plant-model mismatch scenarios for BIO-CS application. Results of the developed framework are compared to a gradient-based Sequential Quadratic Programming (SQP) technique and a classical proportional-integral (PI) controller in terms of optimization and control studies, respectively. As an additional contribution, BIO-CS is also cast as a model predictive controller (MPC) for the first time and compared to the agent-based BIO-CS approach in terms of computational time and tracking error. Closed-loop control results show up to 46% improvement in tracking performance during transient for the multi-agent BIO-CS when compared to BIO-CS as MPC for additional computational expense. The obtained results illustrate the capabilities of this novel integrated framework including BIO-CS as MPC to achieve desired nonlinear system performance for various scenarios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗