Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

CPR methodology with new steady-state criterion and more accurate statistical treatment of channel bow

An overview is given of existing CPR design criteria and the methods used in BWR reload analysis to evaluate the impact of channel bow on CPR margins. Potential weaknesses in today's methodologies are discussed. Westinghouse in collaboration with KKL and Axpo - operator and owner of the Leibstadt NPP - has developed an optimized CPR methodology based on a new criterion to protect against dryout during normal operation and with a more rigorous treatment of channel bow. The new steady-state criterion is expressed in terms of an upper limit of 0.01 for the dryout failure probability per year. This is considered a meaningful and appropriate criterion that can be directly related to the probabilistic criteria set-up for the analyses of Anticipated Operation Occurrences (AOOs) and accidents. In the Monte Carlo approach a statistical modeling of channel bow and an accurate evaluation of CPR response functions allow the associated CPR penalties to be included directly in the plant SLMCPR and OLMCPR in a best-estimate manner. In this way, the treatment of channel bow is equivalent to all other uncertainties affecting CPR. Emphasis is put on quantifying the statistical distribution of channel bow throughout the core using measurement data. The optimized CPR methodology has been implemented in the Westinghouse Monte Carlo code, McSLAP. The methodology improves the quality of dryout safety assessments by supplying more valuable information and better control of conservatisms in establishing operational limits for CPR. The methodology is demonstrated with application examples from the introduction at KKL. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Serpent and MCNP Calculations of the Energy Deposition in the Transformational Challenge Reactor

This paper focuses on the calculation of the energy deposition in the Transformational Challenge Reactor by two major Monte Carlo codes: Serpent and MCNP. The first software computation relies on Kinetic Energy Released per unit Mass (KERMA) factors while the second one relies on Q-values. The results from these two independent computation methodologies are in very good agreement; however, Serpent runs much faster than MCNP (for the same computational model) and allows for a detailed energy deposition distribution from a 1-mm-side square mesh with a relative statistical error between 0.5% and 1%. This detailed energy deposition is suitable for multiphysics analyses aimed at design optimizations. In order to calculate the energy deposition, Serpent needs enhanced ACE files (distributed by the software developers). Unlike other Monte Carlo software that uses inputs based on Python or Java languages, the Serpent input syntax is very similar to that of MCNP; a Python script can convert a MCNP input to a Serpent input in seconds. For simulations not requiring the calculation of the energy deposition, Serpent can also read nuclear data from MCNP ACE files, which eventually improves the comparison of the results of the two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An uncertainty quantification method relevant to material test reactors

Within material test reactor calculations, energy dependent flux and reaction rate uncertainties are typically not quantified when performing as-run analyses to determine the neutron field experienced by the experiment. When high fidelity Monte-Carlo codes are used in such analyses, straight forward methods to calculate output uncertainties are not available, instead expert opinion is used to postulate computational uncertainties. New methods to propagate uncertainties through these high fidelity simulations are available when sufficient computational power is available. A tool is developed here for sampling any part of an MCNP input from random distributions to determine output uncertainties based on those inputs. Another tool is developed to sample nuclear data cross-section in ACE format using multi-group nuclear data covariances. The Total Monte-Carlo Method and Gesellschaft für Anlagen-und Reaktorsicherheit method (GRS) are implemented and compared to one another as well as MCNP sensitivity and uncertainty calculations. The methods were applied to the Godiva critical sphere k-eigenvalue, the UAM pin-cell benchmark energy dependent flux and reaction rates, and the Advanced Test Reactor energy dependent flux within an experimental location. Furthermore, the two methods agree well, with GRS allowing for an order of magnitude speedup for reaction rate uncertainty calculations and several orders of magnitude for eigenvalue uncertainty calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation of neutron and gamma fluxes in support to the interpretation of measuring devices irradiated in the core periphery of the OSIRIS Material Testing Reactor

Technological irradiations carried out in material testing reactors (MTRs) are used to study the behavior of materials under irradiation conditions required by different types of nuclear power plants (NPPs). For MTRs, specific instrumentation is required for the experiment monitoring and for the characterization of irradiation conditions, in particular the flux of neutrons and photons. To measure neutron and photon flux in experimental locations, different sensors can be used, such as SPNDs (self-powered neutron detectors), SPGDs (self-powered gamma detectors) and ionization chambers. These sensors involve interactions producing ultimately a measurable electric current. Various sensors have been recently tested in the core periphery of the OSIRIS reactor (located at the CEA-Saclay center) in order to qualify their responses to the neutron and the photon flux. One of the key input data for this qualification is to have a relevant evaluation of neutron and gamma fluxes at the irradiation location. The objective of this work is to evaluate the neutron and the gamma flux in the core periphery of the OSIRIS reactor. With this intention, specific neutron-photonic three-dimensional calculations have been performed and are mainly based on the TRIPOLI-4{sup R} three-dimensional continuous-energy Monte Carlo code, developed by CEA (Saclay Center) and extensively validated against reactor dosimetry benchmarks. In the case of the OSIRIS reactor, TRIPOLI-4{sup R} code has been validated against experimental results based on neutron flux and nuclear heating measurements performed in ex-core and in-core experiments. In this work, simultaneous contribution of neutrons and gamma photons in the core periphery is considered using neutron-photon coupled transport calculations. Contributions of prompt and decay photons have been taken into account for the gamma flux calculation. Specific depletion codes are used upstream to provide the decay-gamma sources required by TRIPOLI-4 calculations. In this paper, the neutron-photonic calculation scheme used for the neutron-gamma flux evaluation in the OSIRIS core periphery will be first detailed. Then, a comparison of calculated and measured values of neutron and gamma fluxes will be introduced. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation of SPND Beta-Current in AP1000 core

The Self-Powered Neutron Detectors (SPNDs) are widely used in Generation-III commercial PWR due to its small size and external-power free character. It can measure the in-core neutron flux density immediately to obtain the power profile in the core. To better understand the actual state of the simulated core, a SPND beta-current simulation module has been established in the NECP-Bamboo code. Firstly, neutron simulation is carried out in the lattice code Bamboo-Lattice together with nuclide depletion simulation to obtain the depleted composition of the entire lattice including the SPND, and the few-group parameters including density and cross section of emitter material. Secondly, the depleted lattice can then be piped into a Monte-Carlo code for neutron-photon-electron simulation to obtain the electron escape efficiency from the emitter of the SPND to the corresponding collector. Thirdly, the electron escape efficiency can be parameterized into the function of the lattice state parameters similarly to the common few-group constants. Finally, the beta-current was calculated by the core code Bamboo-Core simultaneously with the simulation of the core operation process. The beta-current of the Vanadium SPND in the AP1000 core was simulated and analyzed in this paper. Comparison between simulation and measurement of the beta-current distribution in the specific core state is shown in this paper to verify the effectiveness of the method and the code. The radial normalized current distribution is in good agreement with the measurement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo Simulations of the Water Draining Experiment of Giacint Critical Assembly

The MCNP6 computer program has been successfully extended to simulate reactor dynamics problems with moving parts of the geometries. Different from the dynamic method developed in other Monte Carlo codes, a movement scheme has been developed to account for the geometrical parts motion during the particle random walk. The MCNP6 computer program has been used to simulate two transient experiments of the Giacint critical assembly. The MCNP6 calculated total neutron flux was compared with that from the Serpent simulation. An excellent agreement was obtained between the results of the two Monte Caro computer programs. The MCNP6 calculated total neutron flux was also compared with the two measured transients. The MCNP6 results predicted a faster transient than the experimental data. The MCNP6 transient simulation was improved with an adjusted geometrical model which shifts the fuel rods slightly to match the measured reactivity worth due to the drained water. (c) 2021 Elsevier Ltd. All rights reserved.

MCNP, Moving Geometries, Monte Carlo Reactor Trans↗

Multi-scale Modelling of bcc-Fe Based Alloys for Nuclear Applications

Understanding the basic mechanisms that determine microstructure changes in neutron irradiated steels is vital for a safe lifetime management of existing nuclear reactors and a safe design of future nuclear options. Low-alloyed ferritic steels containing Cu, Ni, Mn and Si as principal solute atoms are used as structural materials for current reactor vessels. The microstructural evolution under irradiation in alloys is decided by the interplay between defect formation and thermodynamic driving forces, together determining the appearance of phase transformations (precipitation, segregation,...) and favouring or delaying the nucleation and growth of point-defect clusters, their diffusion and their mutual recombination or removal at sinks. A reliable description of the production, evolution and accumulation of radiation damage must therefore start from the atomic level and requires being able to describe multicomponent systems for timescales ranging from few picoseconds to years. This goal demands firstly the fabrication of interatomic potentials for alloys that must be both consistent with the thermodynamic properties of the system and capable of reproducing correctly the characteristic solute-point defect interactions, versus ab initio or experimental data. Secondly the performance of extensive molecular dynamics (MD) simulations, to grasp the main mechanisms of defect production, diffusion, mutual interaction, and interaction with solute atoms and impurities. Thirdly, the development of simulation tools capable of describing the microstructure evolution beyond the time-frame and length-scale of MD, while reproducing as much as possible the atomic-level origin of the mechanisms governing the evolution of the system, including phase changes. In this presentation the results of recent efforts made in this direction in the case of Fe-Cu, Fe-Cr and Fe-Ni alloys, as basic model alloys for the description of steels of technological relevance, are highlighted. In particular, advanced techniques to fit interatomic potentials consistent with thermodynamics are proposed and the results of their application to the mentioned alloys are presented. Next, the development of advanced methods, based on the use of artificial intelligence, to improve both the physical reliability and the computational efficiency of kinetic Monte Carlo codes for the study of point-defect clustering and phase changes beyond the scale of MD, is reported. These recent progresses bear the promise of being able, in the near future, of producing reliable tools for the description of the microstructure evolution of realistic model alloys under irradiation. (author)

36 MATERIALS SCIENCE↗

Verification of High-Fidelity Neutronics Code PROTEUS for C5G7 Benchmark Problems

Under the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the 3D whole core transport code PROTEUS has been developed at Argonne National Laboratory to perform the detailed 3D transport calculation for various reactor types including irregular or complex geometric reactors. PROTEUS includes two distinct transport solvers: SN and MOC. Among them, the MOC solver based on the extruded geometry, thus named MOCEX, can produce the faithful 3-D transport solutions by employing the rigorous and robust 2D/3D MOC formulation. This formulation overcomes the drawbacks of a full 3D MOC method requiring enormous memory and computational resources and resolves the instability issues of the 2D/1D method as well. The solution of MOCEX converges to that of a Monte Carlo code as the discretization of angle, space and energy is refined, unlike the 2D/1D method. As a verification and validation (V and V) effort of PROTEUS-MOCEX, this paper presents verification test results using the well-known 3D C5G7 benchmark problems by solving and comparing eigenvalues and pin powers with MCNP solutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The effects of mapping CT images to Monte Carlo materials on GEANT4 proton simulation accuracy

Purpose: Monte Carlo simulations of radiation therapy require conversion from Hounsfield units (HU) in CT images to an exact tissue composition and density. The number of discrete densities (or density bins) used in this mapping affects the simulation accuracy, execution time, and memory usage in GEANT4 and other Monte Carlo code. The relationship between the number of density bins and CT noise was examined in general for all simulations that use HU conversion to density. Additionally, the effect of this on simulation accuracy was examined for proton radiation. Methods: Relative uncertainty from CT noise was compared with uncertainty from density binning to determine an upper limit on the number of density bins required in the presence of CT noise. Error propagation analysis was also performed on continuously slowing down approximation range calculations to determine the proton range uncertainty caused by density binning. These results were verified with Monte Carlo simulations. Results: In the presence of even modest CT noise (5 HU or 0.5%) 450 density bins were found to only cause a 5% increase in the density uncertainty (i.e., 95% of density uncertainty from CT noise, 5% from binning). Larger numbers of density bins are not required as CT noise will prevent increased density accuracy; this applies across all types of Monte Carlo simulations. Examining uncertainty in proton range, only 127 density bins are required for a proton range error of <0.1 mm in most tissue and <0.5 mm in low density tissue (e.g., lung). Conclusions: By considering CT noise and actual range uncertainty, the number of required density bins can be restricted to a very modest 127 depending on the application. Reducing the number of density bins provides large memory and execution time savings in GEANT4 and other Monte Carlo packages.

60 APPLIED LIFE SCIENCES↗

Comparison of air-kerma strength determinations for HDR {sup 192}Ir sources

Purpose: To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) {sup 192}Ir brachytherapy sources maintained by University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. Methods: The improved, laser-aligned seven-distance apparatus of University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR {sup 192}Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the {sup 192}Ir air-kerma calibration coefficient from the NIST air-kerma standards at {sup 137}Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A{sub wall} for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. Results: The average measurements when using the inverse N{sub K} interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Conclusions: Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that it is not necessary to update the current standard maintained at the UWADCL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preparation of nuclear libraries with deterministic and stochastic methods for LWR reflectors

The explicit reflector methodology is used in the system of codes CASMO-5 / SIMULATE-3 to include the reflector around the active core into the computational region and avoid adopting any ad-hoc or experimental albedo coefficients as boundary conditions. However, to complete the core calculation, a set of cross sections and discontinuity factors is needed for the reflector nodes and the accuracy of these nuclear parameters influences the final results, in particular along the peripheral regions of the core. In this paper the explicit reflector methodology of CASMO-5 is adopted to evaluate the few-group cross sections and discontinuity factors of the different reflector cases, based on the design of Generation II and III LWR reactors. In addition, in the perspective of using Monte-Carlo codes as a complementary option for lattice calculations of reflector configurations, the stochastic SERPENT code is also included as part of this benchmark. With the latter, the impact of applying 2-D reflector models with homogenized materials instead of explicit representation of the real geometrical structures is moreover evaluated and shown to be limited. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Watts Bar I ex-core analyses using VERA - 25430

The integration and direct coupling of the Oak Ridge National Laboratory (ORNL) Shift Monte Carlo code within the Consortium for Advanced Simulation of Light Water Reactors (CASL) Virtual Environment for Reactor Applications (VERA) offers unique capabilities that combine high-fidelity in-core and ex-core radiation transport. In this recent development activity, the deterministic neutronics code MPACT performs the in-core radiation transport with temperature feedback using COBRA-TF (CTF), and provides the fission source to Shift for a follow-on fixed source radiation transport calculation to determine ex-core quantities of interest. The coupling of MPACT to Shift allows the neutron source for the ex-core transport to be calculated from the time-dependent, fully coupled MPACT solution. This paper presents the first use of VERA to perform coupon irradiation for code-to-code comparison of its ex-core capabilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Simulation with on the fly Doppler Broadening treatment in RMC

In conventional transient analysis, thermal hydraulics calculations are generally coupled to deterministic neutronics solvers. Due to the limited accuracy of deterministic methods and the rapid development of computer power, Monte Carlo neutronics calculations have received increasing attention nowadays. One of challenges for Monte Carlo methods coupled to thermal hydraulics calculations is the temperature dependent cross sections. Taking the detailed temperature distribution feedback into account, each nuclide may be in a large range of temperatures, pre-generated libraries at every temperature point are no longer applicable owing to unaffordable memory footprint. Different solutions have been proposed to deal with this problem. TMS, accounting for Doppler broadening effect by the explicit treatment of thermal motion, was used to model fast transients in Serpent 2. Stochastic mixing, using two sets of libraries for each nuclide and mixing them to get the correct temperature, was used in transient analysis by Sjenitzer and Hoogenboom. Besides, there are other on the fly Doppler broadening methods being developed, including series expansion of cross sections, multipole representation, different integration algorithms based on Doppler broadening equation. In this paper, on the fly Doppler broadening treatment based on integration algorithms was applied to transient calculation in Reactor Monte Carlo code RMC . In the following section, the integration algorithms implemented and dynamic simulation method in RMC is briefly introduced. Finally, a pure physical transient fuel assembly model was chosen for numerical validation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of the Monte Carlo Adjoint-Weighted and Differential Operator Perturbation Methods

Two perturbation theory methodologies are implemented for k-eigenvalue calculations in the continuous-energy Monte Carlo code, MCNP6. A comparison of the accuracy of these techniques, the differential operator and adjoint-weighted methods, is performed numerically and analytically. Typically, the adjoint-weighted method shows better performance over a larger range; however, there are exceptions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

RIBs for reaction studies at near-barrier energies: the facility EXOTIC at LNL

A new facility, named EXOTIC, for the in-flight production of light low-energy weakly bound Radioactive Ion Beams (RIBs) is now fully operational at the Laboratori Nazionali di Legnaro (LNL) of the INFN. In this contribution we will present the facility, the Monte-Carlo code we developed to properly describe the reaction dynamics inside the production target, the experimental results achieved and a list of possible RIBs delivered from the facility EXOTIC in the next future.

43 PARTICLE ACCELERATORS↗

Multi-cycle reload analysis of a long cycle gas-cooled fast modular reactor

There is currently significant interest in deploying HALEU-fueled fast reactors, including the General Atomics (GA) Fast Modular Reactor (FMR). Such reactors can achieve very long fuel cycles, but with multi-batch loading will take decades to reach equilibrium. This motivates design and analysis of both the initial core and multi-cycle reload, which is typically performed using fast-running, deterministic fast reactor codes such as the Argonne Reactor Computation (ARC) codes. In this paper, multicycle reload of the GA FMR is analyzed using the ARC codes. The GA FMR utilizes 19.75 % enriched fuel in a 16 year cycle with a three-batch strategy, with twice-burned fuel placed on the core periphery. The GA FMR has a softened neutron spectrum due to reflecting elements in the core, so the neutronic solution is first benchmarked against the OpenMC Monte Carlo code. Discrepancy on k eff is 400–600 pcm, likely due to the softened neutron spectrum, heterogeneous fuel assembly design and central reflector. However, the rms discrepancy on the assembly power distribution is only 0.6 %, despite the presence of the central reflector. A reload strategy is devised for the first three cycles of such a reactor, ultimately spanning the first 45–48 years of its operation. The fresh core uses 19.75 %, 19.25 % and 16.75 % enriched fuel in place of fresh, once-burned and twice-burned and is then subsequently refueled with only 19.75 % enriched fuel. The cycle length is varied over 3 cycles of operation to balance fuel utilization and reactor availability, specifically with use of an extended 18-year Cycle 1, followed by a shortened 11-year Cycle 2. Cycle 3 is close to the target 16-year length. Finally, placing twice burned assemblies next to the GA FMR central reflector can reduce power peaking by 3 %, at the expense of slightly reducing the cycle length.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

60 APPLIED LIFE SCIENCES↗