Understanding Critical Systematics on Neutrino Oscillation Experiments from Neutrino-Nucleus Interactions. Final report

This is a final report on the DOE grant DE-SC0017946: Understanding Critical Systematics on Neutrino Oscillation Experiments from Neutrino-Nucleus Interactions. The goal of this proposal was to better understand the complex many-body dynamics of neutrino-nucleus interactions in order to control the systematic uncertainties that will dominate current and future long-baseline neutrino experiments. This work was focused on a new and experimentally challenging aspect of the problem: measuring the abundance and kinematics of final state nucleons. The research leveraged two different detectors and beam energies: the Near Detector (ND) of the NOvA Experiment, off-axis on the NuMI beam- line, and the Accelerator Neutrino Neutron Interaction Experiment (ANNIE), on the Booster Neutrino Beam (BNB). The techniques developed will also help reject the dominant neutrino-induced backgrounds limiting future proton decay searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron monitoring and electrode calorimetry experiments in the HIP-1 Hot Ion Plasma

Results are presented for two diagnostic procedures on HIP-1: neutron diagnostics to determine where neutrons originated within the plasma discharge chamber and electrode calorimetry to measure the steady-state power absorbed by the two anodes and cathodes. Results are also reported for a hot-ion plasma formed with a continuous-cathode rod, one that spans the full length of the test section, in place of the two hollow cathodes. The outboard neutron source strength increased relative to that at the midplane when (1) the cathode tips were moved farther outboard, (2) the anode diameters were increased, and (3) one of the anodes was removed. The distribution of neutron sources within the plasma discharge chamber was insensitive to the division of current between the two cathodes. For the continuous cathode, increasing the discharge current increased the midplane neutron source strength relative to the outboard source strength. Each cathode absorbed from 12 to 15 percent of the input power regardless of the division of current between the cathodes. The anodes absorbed from 20 to 40 percent of the input power. The division of power absorption between the anodes varied with plasma operating conditions and electrode placement.

Reinmann, J. J.↗

Calibration of ITER Instant Power Neutron Monitors: Recommended Scenario of Experiments at the Reactor

Instant power is a key parameter of the ITER. Its monitoring with an accuracy of a few percent is an urgent and challenging aspect of neutron diagnostics. In a series of works published in Problems of Atomic Science and Technology, Series: Thermonuclear Fusion under a common title, the step-by-step neutronics analysis was given to substantiate a calibration technique for the DT and DD modes of the ITER. A Gauss quadrature scheme, optimal for processing “expensive” experiments, is used for numerical integration of {sup 235}U and {sup 238}U detector responses to the point sources of 14-MeV neutrons. This approach allows controlling the integration accuracy in relation to the number of coordinate mesh points and thus minimizing the number of irradiations at the given uncertainty of the full monitor response. In the previous works, responses of the divertor and blanket monitors to the isotropic point sources of DT and DD neutrons in the plasma profile and to the models of real sources were calculated within the ITER model using the MCNP code. The neutronics analyses have allowed formulating the basic principles of calibration that are optimal for having the maximum accuracy at the minimum duration of in situ experiments at the reactor. In this work, scenarios of the preliminary and basic experimental ITER runs are suggested on the basis of those principles. It is proposed to calibrate the monitors only with DT neutrons and use correction factors to the DT mode calibration for the DD mode. It is reasonable to perform full calibration only with {sup 235}U chambers and calibrate {sup 238}U chambers by responses of the {sup 235}U chambers during reactor operation (cross-calibration). The divertor monitor can be calibrated using both direct measurement of responses at the Gauss positions of a point source and simplified techniques based on the concepts of equivalent ring sources and inverse response distributions, which will considerably reduce the amount of measurements. It is shown that the monitor based on the average responses of the horizontal and vertical neutron chambers remains spatially stable as the source moves and can be used in addition to the staff monitor at neutron fluxes in the detectors four orders of magnitude lower than on the first wall, where staff detectors are located. Owing to low background, detectors of neutron chambers do not need calibration in the reactor because it is actually determination of the absolute detector efficiency for 14-MeV neutrons, which is a routine out-of-reactor procedure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fission neutron activations of stainless steel and its corresponding elemental components

Characterizing neutron activation of stainless steel is a critical task for many applications, and yet little activation data is available for this alloy. To address the need, a series of neutron activation experiments have been performed using the Flattop critical assembly at the National Criticality Experiments Research Center. Several experimental conditions were probed for complete understanding of the neutron environment, including foil composition and position within the assembly. The experimental results reported here will aid in the production of stainless steel benchmarks for a range of nuclear data applications including those used in nuclear forensics analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Vacancy-driven variations in the phonon density of states of fast neutron irradiated nuclear graphite

Research examining radiation damage and its effects in graphite began in the 1940’s during the development of moderated nuclear reactors. Interest in this topic is expanding because of emerging applications associated with fullerenes and carbon nanostructures as well as its long-standing use as a fission moderator. In this work, we report the measurements of the full phonon density of states of irradiated nuclear graphite using inelastic neutron scattering experiments at room temperature. The samples were previously exposed to different levels of neutron doses and irradiation temperatures. The phonon density of states of perfect and defected graphite supercells including different configurations of vacancies and interstitials were calculated using first-principles direct method. Despite high neutron irradiation doses, the scattering measurements show that the induced damage is localized, and the layered structure is preserved. In conclusion, a comparison of the measured phonon densities of states of irradiated samples with those calculated of defected supercells indicates that the main changes observed are mainly attributed to formation of vacancies.

36 MATERIALS SCIENCE↗

Spin and Parity Assignment of Neutron Resonances using Gamma-ray Multiplicity

Decay gamma rays following neutron capture on various isotopes are collected by the Detector for Advanced Neutron Capture Experiments (DANCE) array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation (160 detectors) and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a given isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. The multiplicity distribution contains the signatures of spin and parity of the capture state. Under suitable circumstances where the difference between spins of the initial (capture) and final (ground) state is large enough, the signatures in the multiplicity distribution can be used in improving the spin assignment of the initial state. The spin assignment is applied with varying degree of success to difference isotopes and description of this application for {sup 95}Mo, {sup 151,153}Eu, and {sup 155,157}Gd is reviewed briefly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New measurements of the coherent and incoherent neutron scattering lengths of 13C

The techniques of neutron interferometry and neutron diffraction were used to determine the coherent and incoherent neutron scattering lengths of 13C. From a neutron interferometry measurement of the optical path difference in liquid samples: 13CS2 versus natCS2, we obtain a bound coherent scattering length of bcoh,13C = 6.502 0.003 fm which differs appreciably from the standard tabulated value of 6.19 0.09 fm. The resulting contrast of only 0.146(3) fm with respect to bcoh,natC = 6.6484 0.0013 fm has consequences for neutron diffraction experiments involving 13C isotopic substitution. Combining our result for bcoh,13C with precise neutron diffraction measurements of the self-scattering intensities of liquid samples: 13CS2 versus natCS2, and 13CO2 versus 12CO2, we deduce a bound incoherent scattering length of bincoh,13C = −0.73 0.14 fm that is consistent with the standard tabulated value of −0.52 0.09 fm. The results presented here have required accurate measurements of small effects, for which particular attention has been given to the data analysis.

carbon isotopes↗

Spin and parity assignments for {sup 94,95}Mo neutron resonances

The {gamma} rays following the {sup 94,95}Mo(n,{gamma}) reactions were measured as a function of incident neutron energy by the time-of-flight method with the DANCE (Detector for Advanced Neutron Capture Experiments) array of 160 BaF{sub 2} scintillation detectors at the Los Alamos Neutron Science Center. The targets were enriched samples: 91.59% {sup 94}Mo and 96.47% {sup 95}Mo. The {gamma}-ray multiplicities and energy spectra for different multiplicities were measured in s- and p-wave resonances up to E{sub n}=10 keV for {sup 94}Mo and up to E{sub n}=2 keV for {sup 95}Mo. Definite spins and parities were assigned in {sup 96}Mo for about 60% of the resonances, and tentative spins and parities were assigned for the remaining resonances. In {sup 95}Mo the parities were determined for the observed resonances, confirming previously known assignments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test of the statistical model in {sup 96}Mo with the BaF{sub 2}{gamma} calorimeter DANCE array

The {gamma}-ray cascades following the {sup 95}Mo(n,{gamma}){sup 96}Mo reaction were studied with the {gamma} calorimeter DANCE (Detector for Advanced Neutron Capture Experiments) consisting of 160 BaF{sub 2} scintillation detectors at the Los Alamos Neutron Science Center. The {gamma}-ray energy spectra for different multiplicities were measured for s- and p-wave resonances below 2 keV. The shapes of these spectra were found to be in very good agreement with simulations using the DICEBOX statistical model code. The relevant model parameters used for the level density and photon strength functions were identical with those that provided the best fit of the data from a recent measurement of the thermal {sup 95}Mo(n,{gamma}){sup 96}Mo reaction with the two-step-cascade method. The reported results strongly suggest that the extreme statistical model works very well in the mass region near A=100.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fundamental Neutron Physics: Theory and Analysis

The goal of the proposed research is the study of the possible manifestations of new physics beyond the Standard model in fundamental neutron physics, with emphasis on fundamental symmetries and "exotic'' interactions. The main part of the research will be focused on theoretical support of the search for Time Reversal Invariance Violation (TRIV) in neutron nuclei scattering. The existence of our universe, and the prevalence of matter over antimatter, requires TRIV (the impossibility of going from the past to the future). However, the source of TRIV in the Standard model is not strong enough to explain why our universe exists. Thus, the observation of large TRIV effects will be a clear signal of new physics. The proposed research topics include calculations of Parity Violating (PV) and TRIV effects in neutron nuclei scattering on different targets, and the study of the possible manifestations of new physics in neutron-decays, neutron-antineutron oscillations, and in interactions of ultra-cold neutrons with nuclei. This research will provide theoretical support to the ongoing experimental programs related to the search for TRIV in neutron scattering at Los Alamos National Laboratory and J-PARC (Japan), and will contribute in the efforts in searching for new physics in fundamental neutron physics experiments at the Oak Ridge National Laboratory, and at other national and international neutron research centers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

The ORNL High Flux Isotope Reactor and New Advanced Fuel Testing Capabilities

The U.S. Department of Energy s High Flux Isotope Reactor (HFIR), located at the Oak Ridge National Laboratory (ORNL), was originally designed (in the 1960s) primarily as a part of the overall program to produce transuranic isotopes for use in the heavy-element research program of the United States. Today, the reactor is a highly versatile machine, producing medical and transuranic isotopes and performing materials test experimental irradiations and neutron-scattering experiments. The ability to test advanced fuels and cladding materials in a thermal neutron spectrum in the United States is limited, and a fast-spectrum irradiation facility does not currently exist in this country. The HFIR has a distinct advantage for consideration as a fuel/cladding irradiation facility because of the extremely high neutron fluxes that this reactor provides over the full thermal- to fast-neutron energy range. New test capabilities have been developed that will allow testing of advanced nuclear fuels and cladding materials in the HFIR under prototypic light-water reactor (LWR) and fast-reactor (FR) operating conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Pulsed Die-Away Experiments at LLNL [Slides]

This presentation discusses why PNDA is ideal for TSL validations as it does not require fissile material, it has very simple target shapes and compositions, it is only sensitive to absorption and scattering of target medium, and that well conducted experiments have uncertainties of 0.1% - 0.5%. The presentation concludes by examining PNDA’s advantages and its role in nuclear data validations as it offers a cost-effective experiment for an integral benchmark, it provides the ability to focus on specific cross section data validation including thermal neutron absorption and thermal scattering laws, and the low experimental uncertainty makes it an excellent benchmark candidate. Additionally, it is easily tunable and can facilitate temperature dependent cross section validation by cooling or heating up targets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Scattering Application of Polarized Solid Target in Materials Research

Neutron scattering is one of the most important tools for materials research. However, neutrons are very expensive to produce. Even with the best sources, such as the newly completed Spallation Neutron Source at the Oak Ridge National Laboratory, most neutron scattering experiments are still flux limited. One way to improve the experimental data is polarized neutron scattering from polarized solid target: the strong spin-dependent neutron scattering cross-section can increase the coherent scattering and decrease the incoherent scattering at the same time, thereby significantly enhancing the signal to noise ratio. Hydrogen, abundant in most soft condensed matters, has a strong spin-dependent scattering cross-section. Early applications of polarized neutron scattering in biological soft condensed matters have already demonstrated the huge potential of this technique. Here we describe the polarized target program at the SNS. The program is under active construction and is aimed at serving neutron scattering at the SNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on the neutron energy distribution measurements at the RECH-1 Chilean nuclear reactor

Neutron activations experiments has been perform at the RECH-1 Chilean Nuclear Reactor to measure its neutron flux energy distribution. Samples of pure elements was activated to obtain the saturation activities for each reaction. Using - ray spectroscopy we identify and measure the activity of the reaction product nuclei, obtaining the saturation activities of 20 reactions. GEANT4 and MCNP was used to compute the self shielding factor to correct the cross section for each element. With the Expectation-Maximization algorithm (EM) we were able to unfold the neutron flux energy distribution at dry tube position, near the RECH-1 core. In this work, we present the unfolding results using the EM algorithm.