Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7 Degree-Sign at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue-based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preparation of cobalt ferrite nanoparticles via a novel solvothermal approach using divalent iron salt as precursors

Graphical abstract: CoFe{sub 2}O{sub 4} nanoparticles are obtained via solvothermal approach using Fe{sup 2+} salt as iron resource. The magnetic properties can be modified by some additives. Display Omitted Highlights: ► CoFe{sub 2}O{sub 4} nanoparticles are synthesized by a facile one-step novel solvothermal method. ► The system is firstly performed in water–glycol mixture solvent with an ordinary air surrounding. ► The ferrous ions are used as iron source without adding oxidant. ► It is firstly found the low-coercivity CoFe{sub 2}O{sub 4} nanoparticles can be obtained with the help of some additives in the synthesis system. -- Abstract: Cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles are synthesized by a facile novel solvothermal method. The reactions are firstly performed in water–glycol system and Fe{sup 2+} salt is used as iron source without oxidant help. Some factors influenced the reactions, including temperature, reaction time, additives, are investigated. The samples are characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscopy (SEM), respectively. The magnetic properties of some samples are detected by vibrating sample magnetometry techniques (VSM). It is firstly found that the magnetism of cobalt ferrites nanomaterials can be modified by some additives. The coercivity of CoFe{sub 2}O{sub 4} nanoparticles evidently decreases from 600 to 50 Oe in the presence of PEG-4000 in the system.

36 MATERIALS SCIENCE↗

MISPR : an open-source package for high-throughput multiscale molecular simulations

Computational tools provide a unique opportunity to study and design optimal materials by enhancing our ability to comprehend the connections between their atomistic structure and functional properties. However, designing materials with tailored functionalities is complicated due to the necessity to integrate various computational-chemistry software (not necessarily compatible with one another), the heterogeneous nature of the generated data, and the need to explore vast chemical and parameter spaces. The latter is especially important to avoid bias in scattered data points-based models and derive statistical trends only accessible by systematic datasets. Here, we introduce a robust high-throughput multi-scale computational infrastructure coined MISPR (Materials Informatics for Structure–Property Relationships) that seamlessly integrates classical molecular dynamics (MD) simulations with density functional theory (DFT). By enabling high-performance data analytics and coupling between different methods and scales, MISPR addresses critical challenges arising from the needs of automated workflow management and data provenance recording. The major features of MISPR include automated DFT and MD simulations, error handling, derivation of molecular and ensemble properties, and creation of output databases that organize results from individual calculations to enable reproducibility and transparency. In this work, we describe fully automated DFT workflows implemented in MISPR to compute various properties such as nuclear magnetic resonance chemical shift, binding energy, bond dissociation energy, and redox potential with support for multiple methods such as electron transfer and proton-coupled electron transfer reactions. The infrastructure also enables the characterization of large-scale ensemble properties by providing MD workflows that calculate a wide range of structural and dynamical properties in liquid solutions. MISPR employs the methodologies of materials informatics to facilitate understanding and prediction of phenomenological structure–property relationships, which are crucial to designing novel optimal materials for numerous scientific applications and engineering technologies.

36 MATERIALS SCIENCE↗

Creating an Interprocedural Analyst-Oriented Data Flow Representation for Binary Analysts (CIAO)

National security missions require understanding third-party software binaries, a key element of which is reasoning about how data flows through a program. However, vulnerability analysts protecting software lack adequate tools for understanding data flow in binaries. To reduce the human time burden for these analysts, we used human factors methods in a rolling discovery process to derive user-centric visual representation requirements. We encountered three main challenges: analysis projects span weeks, analysis goals significantly affect approaches and required knowledge, and analyst tools, techniques, conventions, and prioritization are based on personal preference. To address these challenges, we initially focused our human factors methods on an attack surface characterization task. We generalized our results using a two-stage modified sorting task, creating requirements for a data flow visualization. We implemented these requirements partially in manual static visualizations, which we informally evaluated, and partially in automatically generated interactive visualizations, which have yet to be integrated into workflows for evaluation. Our observations and results indicate that 1) this data flow visualization has the potential to enable novel code navigation, information presentation, and information sharing, and 2) it is an excellent time to pursue research applying human factors methods to binary analysis workflows.

42 ENGINEERING↗

Fluorescence properties of Tb{sup 3+} and Sm{sup 3+} activated novel LiAl{sub 7}B{sub 4}O{sub 17} host via solution combustion synthesis

Graphical abstract: - Highlights: • New LiAl{sub 7}B{sub 4}O{sub 17}:Tb{sup 3+}, Sm{sup 3+} phosphors were synthesized first time by solution combustion method. • The LiAl{sub 7}B{sub 4}O{sub 17}:Tb{sup 3+} emissions; 489, 544, 586 and 623 nm (λ{sub ex} = 234 nm). • Also for LiAl{sub 7}B{sub 4}O{sub 17}:Sm{sup 3+}; 564, 601 and 649 nm (λ{sub ex} = 403 nm). • Synthesized materials were characterized by powder XRD, FE-SEM. • Concentration quenching mechanism and critical transfer distance of Tb{sup 3+} and Sm{sup 3+} in the prepared sample has been investigated. - Abstract: Novel LiAl{sub 7}B{sub 4}O{sub 17} (LABO) phosphor activated with trivalent rare earth ions (RE = Tb, Sm) was synthesized by using solution combustion synthesis. The powder X-ray diffraction (XRD), field emission-scanning electron microscope (FE-SEM), photoluminescence (PL), critical transfer distance (R{sub c}) and quenching mechanism studies were employed to characterize the samples. Under ultraviolet irradiation of the LiAl{sub 7}B{sub 4}O{sub 17}: Tb{sup 3+}, Sm{sup 3+} phosphors exhibit the typical green ({sup 5}D{sub 4} → {sup 7}F{sub j} = 6, 5, 4 and 3) emission band of the Tb{sup 3+} ions, as well as an orange-red and red ({sup 4}G{sub 5/2} → {sup 6}H{sub J=5/2,} {sub 7/2,} {sub 9/2}) emission bands of the Sm{sup 3+} ions. These results suggest that Tb{sup 3+} and Sm{sup 3+} activated LABO phosphor could be promising in vision of the necessity for solid state lighting applications.

36 MATERIALS SCIENCE↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗

MultiTaskDeltaNet: change detection-based image segmentation for operando ETEM with application to carbon gasification kinetics

Transforming in situ transmission electron microscopy (TEM) imaging into a tool for spatially-resolved operando characterization of solid-state reactions requires automated, high-precision semantic segmentation of dynamically evolving features. However, traditional deep learning methods for semantic segmentation often face limitations due to the scarcity of labeled data, visually ambiguous features of interest, and scenarios involving small objects. To tackle these challenges, we introduce MultiTaskDeltaNet (MTDN), a novel deep learning architecture that creatively reconceptualizes the segmentation task as a change detection problem. By implementing a unique Siamese network with a U-Net backbone and using paired images to capture feature changes, MTDN effectively leverages minimal data to produce high-quality segmentations. Furthermore, MTDN utilizes a multi-task learning strategy to exploit correlations between physical features of interest. In an evaluation using data from in situ environmental TEM (ETEM) videos of filamentous carbon gasification, MTDN demonstrated a significant advantage over conventional segmentation models, particularly in accurately delineating fine structural features. Notably, MTDN achieved a 10.22% performance improvement over conventional segmentation models in predicting small and visually ambiguous physical features. This work bridges key gaps between deep learning and practical TEM image analysis, advancing automated characterization of nanomaterials in complex experimental settings.

08 HYDROGEN↗

Synthesis, structural characterization, and electronic structure of the novel Zintl phase Ba 2 ZnP 2

The novel Zintl phase dibarium zinc diphosphide (Ba 2 ZnP 2 ) was synthesized for the first time. This was accom­plished using the Pb flux technique, which allowed for the growth of crystals of adequate size for structural determination via single-crystal X-ray diffraction methods. The Ba 2 ZnP 2 com­pound was determined to crystallize in a body-centered ortho­rhom­bic space group, Ibam (No. 72). Formally, this crystallographic arrangement belongs to the K 2 SiP 2 structure type. Therefore, the structure can be best described as infinite [ZnP 2 ] 4– polyanionic chains with divalent Ba 2+ cations located between the chains. All valence electrons are partitioned, which conforms to the Zintl–Klemm concept and suggests that Ba 2 ZnP 2 is a valence-precise com­position. In conclusion, the electronic band structure of this new com­pound, com­puted with the aid of the TB–LMTO–ASA code, shows that Ba 2 ZnP 2 is an intrinsic semiconductor with a band gap of ca 0.6 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrothermal synthesis of nanocrystalline VO{sub 2} from poly(diallyldimethylammonium) chloride and V{sub 2}O{sub 5}

Novel vanadium dioxide nanorods were fabricated from V{sub 2}O{sub 5} in the presence of a reducing agent, the poly(diallyldimethylammonium chloride) (PDDA) via a hydrothermal method at 180 {sup o}C for 48 h. The samples produced were characterized by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), infrared spectroscopy (FTIR), nitrogen adsorption (BET) and thermogravimetry (TG/DTG). The nanorods obtained are approximately 50 nm wide and from 300 to 500 nm long and presents high surface area (42 m{sup 2} g{sup -1}). The nanocrystalline B phase VO{sub 2} is not produced by hydrothermal treatment in the absence of the PDDA polyelectrolyte.

36 MATERIALS SCIENCE↗

Proton light yield in organic scintillators using a double time-of-flight technique

Recent progress in the development of novel organic scintillators necessitates modern characterization capabilities. As the primary means of energy deposition by neutrons in these materials is n-p elastic scattering, knowledge of the proton light yield is paramount. This work establishes a new model-independent method to continuously measure the proton light yield in organic scintillators over a broad energy range. Using a deuteron breakup neutron source at the 88-in. Cyclotron at Lawrence Berkeley National Laboratory and an array of organic scintillators, the proton light yield of EJ-301 and EJ-309, commercially available organic liquid scintillators from Eljen Technology, was measured via a double time-of-flight technique. The light yield was determined using a kinematically over-constrained system in the proton energy range of 1–20 MeV. The effect of the pulse integration length on the magnitude and shape of the proton light yield relation was also explored. In conclusion, this work enables accurate simulation of the performance of advanced neutron detectors and supports the development of next-generation neutron imaging systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of Lithium Content and Sintering Additives in Tape Cast Lithium Garnet Electrolyte Sheets

The lithium garnet (LLZO) remains one of the most promising electrolyte materials for producing solid state batteries. Tape casting is one method for producing the thin ceramic electrolyte layer required for a high-performance solid state battery. Processing of LLZO is complicated by several factors including lithium volatilization, abnormal grain growth and phase instability. Many of these issues are exacerbated in tape cast sheets by the sheets' higher surface area to volume ratio, when compared to pellet processing methods. Here, we report on an environmentally friendly aqueous tape casting process for LLZO using methylcellulose as a binder and compare final sheet properties to other, solvent-based, options. Solids loading, binder content, dispersant composition, and wetting agent type are varied to improve ease of casting and enhance properties of the as-cast tape. Lithium content in sintered LLZO sheets is controlled by the inclusion of excess Li 2 CO 3 as lithium source in the ceramic tape itself and by a novel method of producing a lithium-saturated furnace atmosphere. Sintering time and temperature are optimized, and rapid thermal processing is investigated as a method of reducing lithium loss. Al 2 O 3 and MgO are examined for use as sintering additives. Characterization of LLZO sheets is performed with XRD, EIS and SEM. Li 2 CO 3 and sintering additive levels are optimized for ionic conductivity and density. The optimization effort improved the conductivity and density of 100µm thick sintered sheets to greater than 3x10 -4 S/cm conductivity and 90% density.

36 MATERIALS SCIENCE↗

Understanding and Tailoring Diffusion and Co-Adsorption Inside the Confined Pores of Metal-Organic Frameworks (Final Scientific/Technical Report for Award DE-SC0019902)

The aim of this program was to gain a fundamental understanding of the behavior of various guest molecules in nano-confined environments, such as metal organic frameworks (MOFs), using a combination of novel synthesis, ab initio modeling, and in situ characterization. Through this project, we developed a concise understanding of the mechanisms that control adsorption/desorption of gaseous molecules and their mixtures, leading to design/synthesis guidelines for MOFs with desired functionality. We further developed methods to disentangle kinetic from thermodynamic effects during adsorption, as well as to characterize the interactions at play. In the first funding cycle, the focus was on the unambiguously characterization of co-adsorption and diffusion of gasses/vapors and their mixtures. In the second funding cycle, the focus was on characterizing the effects of the nano-confinement on the kinetics and thermodynamics of adsorption processes inside MOFs, again with an emphasis on mixtures of gasses and vapors. The nano-confinement can tip the thermodynamic vs. kinetic balance, and current understanding and theory based on single-component analysis can lead to incorrect predictions for mixtures. This is of particular interest in real-world applications, where gasses/vapors are typically mixed, contain impurities, or are often exposed to humid conditions. Our main findings were: (i) within confined environments the adsorption behavior of mixed gasses/vapors can be drastically different from the “sum” of the corresponding single phases; (ii) co-adsorption is often competitive and detrimental to performance, but it can also be cooperative and beneficial; (iii) in some co-adsorbed gasses/vapors, molecules that are strongly bound in the single-component phase can be replaced by molecules that are nominally weaker bound (molecular exchange) due to guest-guest interactions that lower the kinetic barriers and favor the final adsorption state; (iv) kinetic and thermodynamic effects can be precisely controlled through pore-size engineering and synthesis; and, (v) kinetic effects can be identified and disentangled from thermodynamic effects during adsorption through a series of sequential and simultaneous gas loading measurements. The short-term goal of this program was the controlling and understanding of common MOF systems in real-world situations where gasses/vapors are mixed, which will have an important impact on industrial processes and applications from gas storage and sequestration to catalysis and sensors. The long-term goals include the development of theoretical and experimental methods for gaining a fundamental understanding of adsorption/reaction processes within MOFs, as well as new guidelines for synthesizing MOFs with tailored physical and chemical properties.

36 MATERIALS SCIENCE↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Used Fuel Storage Monitoring Using Helium-4 Scintillation Fast Neutron Detectors and Neutron Spectral Analysis

This project aimed to address the technology gap in the reliable methods to verify contents of sealed dry storage casks for spent nuclear fuel. Helium-4 gas scintillation neutron detectors was proposed to be developed into a neutron spectroscopy and imaging system for nuclear security and safeguards applications. 4 He gas is significantly more available than 3 He gas and it has unique advantages such as low gamma interaction probability and direct detection of fast neutrons. Due to the sheer amount of fissile materials in a single dry cask, there is a significant neutron fluence emitted whose energies range from thermal to uncollided high-energy neutrons suitable for the detection capability of the 4 He detectors. Our project demonstrated the first ever neutron spectroscopic capabilities using 4 He detectors, explored novel detector design and performed detector characterization. It further qualified the detectors for use in various applications including high-flux environments with significant gamma-fluence. Computer simulations were used to test various large cask measurement system designs and tests, beyond the compact prototype system and laboratory measurements exploring the feasibility of the neutron spectroscopic approach. Although some cask-characterization methods proved unfeasible, alternative characterization methods using the He-4 detectors were explored and generated promising results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel vibration-based fault diagnostic algorithm for gearboxes under speed fluctuations without rotational speed measurement

The localized failures of gears introduce cyclic-transient impulses in the measured gearbox vibration signals. These impulses are usually identified from the sidebands around gear-mesh harmonics through the spectral analysis of cyclo-stationary signals. However, in practice, several high-powered applications of gearboxes like wind turbines are intrinsically characterized by nonstationary processes that blur the measured vibration spectra of a gearbox and deteriorate the efficacy of spectral diagnostic methods. Although order-tracking techniques have been proposed to improve the performance of spectral diagnosis for nonstationary signals measured in such applications, the required hardware for the measurement of rotational speed of these machines is often unavailable in industrial settings. Moreover, existing tacho-less order-tracking approaches are usually limited by the high time-frequency resolution requirement, which is a prerequisite for the precise estimation of the instantaneous frequency. To address such issues, a novel fault-signature enhancement algorithm is proposed that can alleviate the spectral smearing without the need of rotational speed measurement. This proposed tacho-less diagnostic technique resamples the measured acceleration signal of the gearbox based on the optimal warping path evaluated from the fast dynamic time-warping algorithm, which aligns a filtered shaft rotational harmonic signal with respect to a reference signal assuming a constant shaft rotational speed estimated from the approximation of operational speed. The effectiveness of this method is validated using both simulated signals from a fixed-axis gear pair under nonstationary conditions and experimental measurements from a 750-kW planetary wind turbine gearbox on a dynamometer test rig. Lastly, the results demonstrate that the proposed algorithm can identify fault information from typical gearbox vibration measurements carried out in a resource-constrained industrial environment.

17 WIND ENERGY↗

Synthesis and Characterization of a Novel Ligand and Spectroscopic Study of the Formation of its Complexes with Different Cations and Their Sensory Characteristics

A new ligand (L), N,N′-bis(2-hydroxybenzyl)-1,2-diaminoethane, was synthesized and characterized. The sensing behavior of L toward various metal ions was investigated by spectrofluorometric and UV-Vis spectrophotometric methods. The sensor displayed selective and sensitive recognition toward Fe{sup 3+} and Fe{sup 2+} in acetonitrile. The fluorescence of L was quenched mainly by Fe{sup 3+}, and a considerable enhancement of fluorescence was observed in the presence of Zn{sup 2+}. Using multivariate hard modeling and stoichiometry, the concentration, spectral profiles, and formation constants of the studied complexes were calculated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing a supernova’s standing accretion shock instability with neutrinos and gravitational waves

Here, we perform a novel multi-messenger analysis for the identification and parameter estimation of the Standing Accretion Shock Instability (SASI) in a core collapse supernova with neutrino and gravitational wave (GW) signals. In the neutrino channel, this method performs a likelihood ratio test for the presence of SASI in the frequency domain. For gravitational wave signals we process an event with a modified constrained likelihood method. Using simulated supernova signals, the properties of the Hyper-Kamiokande neutrino detector, and O3 LIGO Interferometric data, we produce the two-dimensional probability density distribution (PDF) of the SASI activity indicator and calculate the probability of detection P D as well as the false identification probability P FI . We discuss the probability to establish the presence of the SASI as a function of the source distance in each observational channel, as well as jointly. Compared to a single-messenger approach, the joint analysis results in P D (at P FI = 0.1) of SASI activities that is larger by up to ≈ 40% for a distance to the supernova of 5 kpc. We also discuss how accurately the frequency and duration of the SASI activity can be estimated in each channel separately. Our methodology is suitable for implementation in a realistic data analysis and a multi-messenger setting.