Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operation optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Sensitive magnetic force detection with a carbon nanotube resonator

We propose a technique for sensitive magnetic point force detection using a suspended carbon nanotube (CNT) mechanical resonator combined with a magnetic field gradient generated by a ferromagnetic gate electrode. Numerical calculations of the mechanical resonance frequency show that single Bohr magneton changes in the magnetic state of an individual magnetic molecule grafted to the CNT can translate to detectable frequency shifts, on the order of a few kHz. The dependences of the resonator response to device parameters such as length, tension, CNT diameter, and gate voltage are explored and optimal operating conditions are identified. A signal-to-noise analysis shows that, in principle, magnetic switching at the level of a single Bohr magneton can be read out in a single shot on timescales as short as 10 μs. This force sensor should enable new studies of spin dynamics in isolated single molecule magnets, free from the crystalline or ensemble settings typically studied.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Revisiting single photon avalanche diode current-voltage modeling and transient characteristics

A model for the current-voltage and transient behavior of Single Photon Avalanche Diodes (SPADs) based on device physics is presented. The results of the model are compared to actual measurements and a reasonable fit is seen. Additionally, the model provides a useful tool for designing quenching circuitry and determining optimal operation conditions of the SPAD.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Z{sub 1/2}, EH{sub 5}, and Ci1 deep defects on the performance of n-type 4H-SiC epitaxial layers Schottky detectors: Alpha spectroscopy and deep level transient spectroscopy studies

Spectroscopic performance of Schottky barrier alpha particle detectors fabricated on 50 μm thick n-type 4H-SiC epitaxial layers containing Z{sub 1/2}, EH{sub 5}, and Ci1 deep levels were investigated. The device performance was evaluated on the basis of junction current/capacitance characterization and alpha pulse-height spectroscopy. Capacitance mode deep level transient spectroscopy revealed the presence of the above-mentioned deep levels along with two shallow level defects related to titanium impurities (Ti(h) and Ti(c)) and an unidentified deep electron trap located at 2.4 eV below the conduction band minimum, which is being reported for the first time. The concentration of the lifetime killer Z{sub 1/2} defects was found to be 1.7 × 10{sup 13} cm{sup −3}. The charge transport and collection efficiency results obtained from the alpha particle pulse-height spectroscopy were interpreted using a drift-diffusion charge transport model. Based on these investigations, the physics behind the correlation of the detector properties viz., energy resolution and charge collection efficiency, the junction properties like uniformity in barrier-height, leakage current, and effective doping concentration, and the presence of defects has been discussed in details. The studies also revealed that the dominating contribution to the charge collection efficiency was due to the diffusion of charge carriers generated in the neutral region of the detector. The 10 mm{sup 2} large area detectors demonstrated an impressive energy resolution of 1.8% for 5486 keV alpha particles at an optimized operating reverse bias of 130 V.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced electrocaloric effect in displacive-type organic ferroelectrics

We explore the intrinsic feature of electrocaloric effect (ECE) accompanied by ferroelectric (FE)-paraelectric (PE) transition for displacive-type organic ferroelectrics using Green's function theory. It is demonstrated that decreasing elastic constant K or increasing spin-lattice coupling λ can enhance the ECE, as well as polarization P and transition temperature T{sub C}. Indeed, one expects that the optimal operating temperature for solid-state refrigeration is around room temperature, at which the ECE achieves its maximum. As T{sub C} is tuned to ∼310 K, it presents larger ECE response and remanent polarization with lower coercive field for smaller K value, suggesting that well flexible displacive-type organic ferroelectrics are excellent candidates both for electric cooling and data storage in the design of nonvolatile FE random-access memories. Furthermore, in an electric field, it provides a bridge between a Widom line that denotes FE-PE crossover above T{sub C} and a metaelectric transition line below T{sub C} that demonstrates an FE switching behavior with an antiparallel field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of ion source characterization diagnostics in INTF

INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range

The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial symmetry breaking in single-frequency CCP discharge with transverse magnetic field

An independent control of the flux and energy of ions impacting on an object immersed in a plasma is often desirable for many industrial processes such as microelectronics manufacturing. We demonstrate that a simultaneous control of these quantities is possible by a suitable choice of a static magnetic field applied parallel to the plane electrodes in a standard single frequency capacitively coupled plasma device. Our particle-in-cell simulations show a 60% reduction in the sheath width (that improves control of ion energy) and a fourfold increase in the ion flux at the electrode as a consequence of the altered ion and electron dynamics due to the ambient magnetic field. A detailed analysis of the particle dynamics is presented, and the optimized operating parameters of the device are discussed. In conclusion, the present technique offers a simple and attractive alternative to conventional dual frequency based devices that often suffer from undesirable limitations arising from frequency coupling and electromagnetic effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle transport constraints via Bayesian spectral fitting of multiple atomic lines

Optimized operation of fusion devices demands detailed understanding of plasma transport, a problem that must be addressed with advances in both measurement and data analysis techniques. In this work, we adopt Bayesian inference methods to determine experimental particle transport, leveraging opportunities from high-resolution He-like ion spectra in a tokamak plasma. The Bayesian spectral fitting code is used to analyze resonance (w), forbidden (z), intercombination (x, y), and satellite (k, j) lines of He-like Ca following laser blow-off injections on Alcator C-Mod. This offers powerful transport constraints since these lines depend differently on electron temperature and density, but also differ in their relation to Li-like, He-like, and H-like ion densities, often the dominant Ca charge states over most of the C-Mod plasma radius. Using synthetic diagnostics based on the AURORA package, we demonstrate improved effectiveness of impurity transport inferences when spectroscopic data from a progressively larger number of lines are included.

47 OTHER INSTRUMENTATION↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a LaB6 tip as a thermionically enhanced photoemitter

There is a widespread interest in time-resolved electron spectroscopies such as ultrafast electron diffraction, ultrafast electron microscopy, and ultrafast electron energy loss spectroscopy. These techniques require pulsed electron beams with both high current and brightness. LaB6 is commonly used as a thermionic emitter because of its low work function and high electron yield. However, its use as a pulsed photocathode has not been widely explored. Here, we present measurements of the electron yield from a LaB6 filament exposed to 392 nm UV ultrafast laser pulses under a wide range of filament temperatures. We find that sample heating strongly enhances photoelectron yield, an effect known as thermionically enhanced photoemission. However, it also creates potentially undesirable, continuous thermionic background. We conclude that the ideal optimal operating conditions strongly depend on the type of measurement and require defining and quantifying an appropriate figure of merit.

Physics↗

Parameters of an electric-discharge generator of iodine atoms for a chemical oxygen-iodine laser

Laser-induced fluorescence is used for measuring the concentration of iodine molecules at the output of an electric-discharge generator of atomic iodine. Methyl iodide CH{sub 3}I is used as the donor of atomic iodine. The fraction of iodine extracted from CH{sub 3}I in the generator is {approx}50%. The optimal operation regimes are found in which 80%-90% of iodine contained in the output flow of the generator was in the atomic state. This fraction decreased during the iodine transport due to recombination and was 20%-30% at the place where iodine was injected into the oxygen flow. The fraction of the discharge power spent for dissociation was {approx}3%. (elements of laser setups)

74 ATOMIC AND MOLECULAR PHYSICS↗

Design and analysis of confirmation experiments

The statistical literature and practitioners have long advocated the use of confirmation experiments as the final stage of a sequence of designed experiments to verify that the optimal operating conditions identified as part of a response surface methodology strategy are attainable and able to achieve the value of the response desired. Yet, until recently there has been a gap between this recommendation and details about how to perform an analysis to quantitatively assess whether the confirmation runs are adequate. Likewise, there has been little in the way of specific recommendations for the number and nature of the confirmation runs that should be performed. In this article, we propose analysis methods to assess agreement between the mean response from previous experiments and the confirmation experiment, and suggest a strategy for the design of confirmation experiments that more fully explores the region around the optimum.

97 MATHEMATICS AND COMPUTING↗

Humidified single-scattering albedometer (H-CAPS-PM SSA ): Design, data analysis, and validation

In this work, we report the development and validation of a new humidified aerosol single-scattering albedometer to quantify the effects of water uptake on submicrometer particle optical properties. The instrument simultaneously measures in situ aerosol light extinction ( σ ep ) and scattering ( σ sp ) using a cavity-attenuated phase shift-single scattering albedo particulate matter (PM) monitor (CAPS-PM SSA , Aerodyne Research, Inc., Billerica, MA, USA). It retrieves by difference aerosol light absorption ( σ ap ) and directly quantifies aerosol single-scattering albedo (SSA), the aerosol “brightness.” We custom built a relative humidity (RH) control system using a water vapor-permeable membrane humidifier and coupled it to the CAPS-PM SSA to enable humidified aerosol observations. Our humidified instrument (H-CAPS-PM SSA ) overcomes problems with noise caused by mirror purge-flow humidification, heating, and characterizing cell RH. Careful angular truncation corrections in scattering, particularly for larger particles, were combined with empirical observations. Results show that the optimal operational size to be D p < 400 nm. The H-CAPS-PM SSA was evaluated with several pure single-component aerosols including ammonium sulfate ((NH 4 ) 2 SO 4 ), absorbing nigrosin, and levoglucosan, an organic biomass smoke tracer. The measured σ ep , σ sp , and the derived optical hygroscopicity parameter ( κ ) for size-selected ammonium sulfate are in good agreement with literature values. For dry size-selected nigrosin in the 100 < D p < 400 nm range, SSA values increased from ~0.3 to 0.65 with increasing D p . The enhancement in nigrosin σ ap at RH = 80% was a factor of 1.05–1.20 relative to dry conditions, with the larger particles showing greater enhancement. SSA increased with RH with the largest fractional enhancement measured for the smallest particles. For polydisperse levoglucosan, we measured an optical κ of 0.26 for both light extinction and scattering and negligible absorption. Our new instrument enables reliable observations of the effects of ambient humidity on mixed aerosol optical properties, particularly for light-absorbing aerosols whose climate forcing is uncertain due to measurement gaps.

54 ENVIRONMENTAL SCIENCES↗

On the hydrophilicity of electrodes for capacitive energy extraction

The so-called Capmix technique for energy extraction is based on the cyclic expansion of electrical double layers to harvest dissipative energy arising from the salinity difference between freshwater and seawater. Its optimal performance requires a careful selection of the electrical potentials for the charging and discharging processes, which must be matched with the pore characteristics of the electrode materials. While a number of recent studies have examined the effects of the electrode pore size and geometry on the capacitive energy extraction processes, there is little knowledge on how the surface properties of the electrodes affect the thermodynamic efficiency. In this paper, we investigate the Capmix processes using the classical density functional theory for a realistic model of electrolyte solutions. The theoretical predictions allow us to identify optimal operation parameters for capacitive energy extraction with porous electrodes of different surface hydrophobicity. Finally, in agreement with recent experiments, we find that the thermodynamic efficiency can be much improved by using most hydrophilic electrodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On Building Predictive Digital Twin Incorporating Wave Predicting Capabilities: Case Study on UMaine Experimental Campaign - FOCAL

The response of floating wind turbines (FWT) are susceptible to stochastic wave variations. For the optimal operation of FWT, a comprehensive understanding of the phaseresolved wave dynamics and the consequential system response is crucial for real-time monitoring and control. A multi-variate, multi-step, long short term memory (MLSTM), a type of recurrent neural network (RNN) is used to capture complex system dynamics for real-time application. Results indicate that the integration of a wave prediction-reconstruction (WRP) model substantially enhances prediction accuracy by 50% on average relative to the baseline model. The improvement is consistent across various wave extremity and prediction horizons, thereby significantly broadening the scope for timely and precise predictive capabilities.

17 WIND ENERGY↗

CEBAF accelerator achievements

In the past decade, nuclear physics users of Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) have benefited from accelerator physics advances and machine improvements. As of early 2011, CEBAF operates routinely at 6 GeV, with a 12 GeV upgrade underway. This article reports highlights of CEBAF's scientific and technological evolution in the areas of cryomodule refurbishment, RF control, polarized source development, beam transport for parity experiments, magnets and hysteresis handling, beam breakup, and helium refrigerator operational optimization.

43 PARTICLE ACCELERATORS↗

Stimulated Raman adiabatic passage with unequal couplings: Beyond two-photon resonance

The technique of stimulated Raman adiabatic passage (STIRAP) is a highly efficient tool for coherent population transfer in a chainwise-connected three-state quantum system. It is widely accepted that the two-photon resonance between the two end states of the chain is a crucial condition for STIRAP. This assumption is indeed correct when the two driving fields, pump and Stokes, produce nearly equal couplings for their respective transitions. We show analytically, supported by numeric examples, that when the pump and Stokes couplings differ significantly, the two-photon population transfer profile is distorted and its center is shifted away from the two-photon resonance; hence, the optimal operation of STIRAP demands a two-photon detuning. We derive simple analytic estimates for the center and the width of the two-photon profile. The results are of potential importance in situations when the pump and Stokes fields are of different physical natures (e.g., laser and cavity fields) or when two-photon resonance is unwanted (e.g., in the presence of residual light).

74 ATOMIC AND MOLECULAR PHYSICS↗

Generalized theory of double-resonance optical pumping of {sup 4}He

We present extensions to the theory of double-resonance laser pumping of {sup 4}He in the context of magnetometer instrumentation. This extended theory allows for arbitrary optical polarization, magnetic resonance (H{sub 1}) coil orientation, and overall instrument orientation relative to the ambient magnetic field. Steady-state solutions are presented for portions of the extended parameter space. These calculations are used to analyze the shot-noise-limited sensitivities for helium magnetometers for selected parameter values, and we find that linearly polarized light can have a relatively simple orientational dependence for a particular choice of angle between the H{sub 1} coils and the light polarization vector. Calculations are also compared to experimentally measured magnetic resonance curves, and a shot-noise limit on sensitivity of 6 fT/{radical}(Hz) is determined for a particular magnetometer apparatus using a cell 2.4 cm in diameter and 7.5 cm in length. This extended theory can be utilized to select optimal operational parameter values and obtain ideal sensitivities for helium magnetometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗