Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Light Propagation Considerations For Internally Clad Sapphire Optical Fiber Using the 6Li(n,)3H Reaction

Optical frequency domain reflectometry measurements in internally clad single crystal sapphire fiber have received attention in recent years due to their high temperature distributed sensing potential. As work with these fibers has proceeded, there have been some inconsistencies in the results. Deeper investigation and testing has identified two critical considerations for the proper functioning of these fibers. First, users must address the propagation of multimode light along the outer surface of the fiber. Here, by observing the far-field image of an internally clad sapphire fiber when adding index matching fluid to the outer fiber surface, we demonstrate the effects of removing the higher order modes from these fibers. The addition of index matching fluid resulted in nearly single mode performance where multimode performance was previously observed. Second, users must address the effect that coupling the fiber to the interrogator via silica based fiber has on the internally clad sapphire fibers performance. Direct fusion splicing of silica to sapphire, as has been used in the recent work with these fibers, has a mode filtering effect which can be beneficial towards the modal behavior of the fibers. However, in this paper we demonstrate that the splicing can cause a sensing failure due to little or no low order mode light, that is useful for sensing, returning to the detector. The positive results from recent years have demonstrated that optical frequency domain reflectometry sensing performance will be successful in clad sapphire fiber; but only when the considerations described herein are addressed properly.

47 OTHER INSTRUMENTATION↗

CCN Measurements at Urban Site during CoURAGE

Cloud condensation nuclei (CCN) measurements were collected during CoURAGE from March - June 2025 at the BSEC urban atmospheric chemistry supersite (39.32057 N, 76.6246 W). CCN number concentrations (# cm-3) were obtained at a frequency of 1 second using a cloud condensation nuclei counter (CCN-100, Droplet Measurement Technologies). The CCN counter was operated in stepping mode, measuring CCN over a range of supersaturations from 0.2 to 1.0%. The settings of the instrument were set such that the supersaturation increased in increments of 0.2% up to the maximum supersaturation, and then decreased in increments of 0.2% down to the minimum supersaturation in a repeating cycle. The supersaturation of the instrument was calibrated weekly using ammonium sulfate. The weekly calibrated supersaturation values have been applied to the data. Data during transitions between supersaturation values were removed and replaced with a value of -999. Transitions are defined as the first 210 seconds after a new supersaturation value to ensure the instrument has stabilized following a change in supersaturation. Data were also flagged with a value of -999 if there were concerns with the function of the instrument, specifically the presence of alarm codes, fogging of the optical particle counter (1st stage monitor > 0.4 V), or a sheath to sample flow ratio outside the expected range (< 9 or > 11).

CCN number density↗

Dephasingless two-color terahertz generation

A laser pulse composed of a fundamental and an appropriately phased second harmonic can drive a time-dependent current of photoionized electrons that generates broadband THz radiation. Over the propagation distances relevant to many experiments, dispersion causes the relative phase between the harmonics to evolve. This “dephasing” slows the accumulation of THz energy and results in a multi-cycle THz pulse with significant angular dispersion. Here, we introduce a novel optical configuration that compensates the relative phase evolution, allowing for the formation of a half-cycle THz pulse with almost no angular dispersion. The configuration uses the spherical aberration of an axilens to map a prescribed radial phase variation in the near field to a desired longitudinal phase variation in the far field. Simulations that combine this configuration with an ultrashort flying focus demonstrate the formation of a half-cycle THz pulse with a controlled emission angle and 1/4 the angular divergence of the multi-cycle pulse created by a conventional optical configuration.

47 OTHER INSTRUMENTATION↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

Abstract We report on the design and performance of the B icep3 instrument and its first three-year data set collected from 2016 to 2018. B icep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. B icep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μ K CMB s and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μ K arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μ K arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Smart Adhesive Joint with High-Definition Fiber-Optic Sensing for Automotive Applications

Structural health monitoring of fiber-reinforced composite-based joints for automotive applications during their manufacturing and on-demand assessment for its durability in working environments is critically needed. High-definition fiber-optic sensing is an effective method to measure internal strain/stress development using minimally invasive continuous sensors. The sensing fiber diameters are in the same order of magnitude when compared to reinforcement (glass, basalt, or carbon fibers) used in polymer composites. They also offer a unique ability to monitor the evolution of residual stresses after repeated thermal exposure with varying temperatures for automotive components/joints during painting using an electrophoretic painting process. In this paper, a high-definition fiber-optic sensor utilizing Rayleigh scattering is embedded within an adhesive joint between a carbon fiber-reinforced thermoset composite panel and an aluminum panel to measure spatially resolved strain development, residual strain, and thermal expansion properties during the electrophoretic paint process-simulated conditions. The strain measured by the continuous fiber-optic sensor was compared with an alternate technique using thermal digital image correlation. The fiber-optic sensor was able to identify the spatial variation of residual strains for a discontinuous carbon fiber-reinforced composite with varying local fiber orientations and resin content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-purpose, all-sky photometric redshifts for the Legacy Imaging Surveys Data Release 8

ABSTRACT In this paper, we present photometric redshift (photo-z) estimates for the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys, currently the most sensitive optical survey covering the majority of the extragalactic sky. Our photo-z methodology is based on a machine-learning approach, using sparse Gaussian processes augmented with Gaussian mixture models (GMMs) that allow regions of parameter space to be identified and trained separately in a purely data-driven way. The same GMMs are also used to calculate cost-sensitive learning weights that mitigate biases in the spectroscopic training sample. By design, this approach aims to produce reliable and unbiased predictions for all parts of the parameter space present in wide area surveys. Compared to previous literature estimates using the same underlying photometry, our photo-zs are significantly less biased and more accurate at z > 1, with negligible loss in precision or reliability for resolved galaxies at z < 1. Our photo-z estimates offer accurate predictions for rare high-value populations within the parent sample, including optically selected quasars at the highest redshifts (z > 6), as well as X-ray or radio continuum selected populations across a broad range of flux (densities) and redshift. Deriving photo-z estimates for the full Legacy Imaging Surveys Data Release 8, the catalogues provided in this work offer photo-z estimates predicted to be of high quality for ≳9 × 108 galaxies over ${\sim}19\, 400\, \text{deg}^{2}$ and spanning 0 < z ≲ 7, offering one of the most extensive samples of redshift estimates ever produced.

79 ASTRONOMY AND ASTROPHYSICS↗

Hurtado summer 2025 REDWOODS PWFS code

This release includes code developed by Benjamin Gerard and Joel Hurtado in summer 2025 to model the performance of different modes of the reflective three-sided pyramid wavefront sensor instrument within the REDWOODS module of the Shane Adaptive Optics system at Lick observatory.

Gerard, BenjaminL [Lawrence Livermore National Lab↗

Holographic Lithography for Industrial Nanomanufacturing

The participant constructed interference lithography experiments on their prototype of a coordinated holographic industrial-scale electromagnetic lithography (CHISEL) tool. These experiments involved generating several laser beams and interfering them in photosensitive materials, whereupon subsequent development resulted in micro- and nano-structured samples. We characterized these samples using scanning electron microscopy and various optical interrogation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber optic sensing for strain and temperature

Fiber optic sensing for strain and temperature. This presentation reports the status of the R&D work performed at FNAL on a novel diagnostic tool for superconducting magnet based on fiber optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗