Search NASA⌕ Search

SEARCH · Search NASA

Results for “POLYVINYLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Magnetic field alignment of emulsions to produce porous articles

The use of magnetic fields in the production of porous articles is generally described. Certain embodiments are related to methods of producing porous articles in which magnetic fields are applied to an emulsion to align emulsion droplets. In some embodiments, after the emulsion droplets have been aligned, the emulsion droplets and/or the medium surrounding the emulsion droplets can be removed to leave behind a porous article. According to certain embodiments, polyvinyl alcohol can be used, for example, to stabilize the emulsion droplets and/or bind together components of the porous article. In some embodiments, water-soluble liquid alcohol can be used, for example, to stabilize the suspension of electronically conductive material within a phase of the emulsion.

36 MATERIALS SCIENCE↗

Swell Behavior of Elastomers with a Hydrothermal Liquefaction Bio-Crude and a Fast Pyrolysis Bio-Oil

The compatibility of seventeen elastomer materials with two heavy biofuels (fast pyrolysis bio-oil and hydrothermal liquefaction (HTL) bio-crude) and diesel was assessed through volume change measurements. The elastomers included two fluorocarbons, six acrylonitrile rubbers (NBRs), and one each of fluorosilicone, neoprene, polyurethane, silicone, epichlorohydrin rubber (ECO), a blend of polyvinyl chloride and NBR (OZO), styrene butadiene rubber (SBR), hydrogenated NBR (HNBR) and ethylene propylene diene monomer (EPDM). The specimens were immersed in each test fuel for four weeks at 50°C and then measured for volume change. Afterwards, the specimens were dried, and the volume was remeasured. Ingeneral, the bio-oil produced unacceptable swelling in the fluoroelastomers, ECO, OZO, neoprene, polyurethane, SBR, HNBR, EPDM, silicone and five of the NBRs. In most cases, the HTL bio-crude produced lower (though still unacceptable) swelling than the bio-oil. Materials that showed good compatibility with the HTL biocrude were the fluoroelastomers, OZO, and silicone.

Kass, Michael↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. IEC test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including: poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 cm to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 Degrees C, 65 Degrees C, 75 Degrees C, or 85 Degrees C), respectively. Characterizations were made using a UV-VIS-NIR spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15 kJ?mol-1-80 kJ/mol-1, with an average of 48 kJ/mol-1, similar to the average of 45 kJ/mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

Nanofibers decorated with nanoparticles and methods of their manufacture

Nanostructured materials, and methods and apparatus for their production are provided. Nanostructured materials comprise nanofibers having nanoparticles deposited along the outer surface thereof. The size of the nanofibers and nanoparticles, and the spacing of such nanoparticles along the nanofibers may be controlled over a wide range. Nanostructured materials may comprise a plurality of such nanofibers interwoven together to form fiber cloth-like materials. Many materials may be used to form the nanofibers including polymer nanofiber materials (e.g., polyvinyl alcohol (PVA) polyvinylpyrrolidone (PVP), etc.) along with compatible nanoparticle materials (e.g., salts or other crystallizable materials).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Recovery of uranium from phosphoric acid medium by polymeric composite beads encapsulating organophosphorus extractants

The present study deals with the preparation and evaluation of the poly-ethersulfone (PES) based composite beads encapsulating synergistic mixture of D2EHPA and Cyanex 923 (at 4:1 mole ratio) for the separation of uranium from phosphoric acid medium. SEM was used for the characterization of the composite materials. Addition of 1% PVA (polyvinyl alcohol) improved the internal morphology and porosity of the beads. Additionally, microscopic examination of the composite bead confirmed central coconut type cavity surrounded by porous polymer layer of the beads through which exchange of metal ions take place. Effect of various experimental variables including aqueous acidity, metal ion concentration in aqueous feed, concentration of organic extractant inside the beads, extractant to polymer ratio, liquid to solid (L/S) ratio and temperature on the extraction of uranium was studied. Increase in acidity (1-6 M), L/S ratio (1- 10), metal ion concentration (0.2-3 g/L U{sub 3}O{sub 8}) and polymer to extractant ratio (1:4 -1:10) led to decrease in extraction of uranium. At 5.5 M (comparable to wet process phosphoric acid concentration) the extraction of uranium was about 85% at L/S ratio 5. Increase in extractant concentration inside the bead resulted in enhanced extraction of metal ion. Increase in temperature in the range of 30 to 50 Celsius degrees increased the extraction, whereas further increase to 70 C degrees led to the decrease in extraction of uranium. Amongst various reagents tested, stripping of uranium was quantitative by 12% Na{sub 2}CO{sub 3} solution. Polymeric beads were found to be stable and reusable up-to 10 cycles of extraction/stripping. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Polymer Lifetime in Plutonium Storage Containers - 18508

The plutonium facility at Los Alamos National Laboratory utilizes stainless steel containers for interim storage of plutonium compounds, metals, alloys, and process residues. Various polymer materials are used in these containers, including neoprene rubber gaskets, Viton O-rings, polytetrafluoroethylene membranes, and polyvinyl chloride bags. The DOE Manual, M441.1-1, requires storage containers to have a technically justified design life, and these polymer components play a key role in the determination of the overall design life for the containers. The capabilities at Los Alamos for monitoring degradation and estimating the design life of polymer materials used in plutonium storage containers will be described, along with the results of the lifetime determination studies for the polymer components used in SAVY-4000 and Hagan containers and some proposed alternatives. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colorimetric Detection and Surface Decontamination of Metal Ions by Using Strippable Polymers - 20024

Strippable coating is a low cost and efficient decontamination method far more compatible for the cleaning of surfaces. This method allows contaminant entrapment and removal from different types of surfaces and also characterized by low-secondary waste generation after decontamination. The present work deals with the elaboration and testing of a new composition of Polyvinyl alcohol (PVA) aqueous solutions utilize the TTA (Thenoyl trifluoroacetone) ligand, employed as a strippable coating for the removal of metal ions e.g., UO{sub 2}{sup +2}, Ni{sup +2}, Cu{sup +2}, Fe{sup +3}, V{sup +5}, Eu{sup +3} and Cs{sup +} from 'contaminated' surfaces. The study aims at developing contaminant-sensing and decontaminating coatings for the detection and removal of metal ions from non porous surfaces. This 'smart' coating is shown to exhibit a clear contaminant dependent response in the form of color variation, and a detection sensitivity less than 0.5 μg per cm{sup 2}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chlorine Validation through Critical Integral Experiments

An increased interest in the validation of chlorine nuclear data, specifically 35Cl, in recent years has led to the prioritization of conducting chlorine critical experiments for nuclear data validation and criticality safety evaluations. A previous experiment was conducted with PVC and CPVC (chlorinated polyvinyl chloride) to reduce the margin of subcriticality for PF-4 operations with aqueous plutonium chloride solutions. Challenges in determining the composition of specific polymers, namely the CPVC, made it difficult to characterize, and therefore benchmark. Additional materials that were utilizable for chlorine validation were not immediately clear, as form, strength, purity, and composition are all important. A series of possible absorber materials were identified and studied, but ultimately granular sodium chloride was chosen. In addition to the needs of LANL’s PF-4 other industry collaborators have brought attention to the need for chlorine validation. Specifically, the need for HEU electrorefining with LiCl salts at Y-12 was taken into consideration for this experiment, with the experimental configurations being finely tuned to best meet their needs. Needs for validation were also presented by Idaho National Lab (INL) and TerraPower for validation of their Molten Chloride Reactor Experiment (MCRE) and Molten Chloride Fast Reactor (MCFR) and have also been considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Two-Dimensional Computational Fluid Dynamics and Conduction Simulations of Heat Transfer in Horizontal Window Frames with Internal Cavities

This paper assesses the accuracy of the simplified frame cavity conduction/convection and radiation models presented in ISO 15099 and used in software for rating and labeling window products. Temperatures and U-factors for typical horizontal window frames with internal cavities are compared; results from Computational Fluid Dynamics (CFD) simulations with detailed radiation modeling are used as a reference. Four different frames were studied. Two were made of polyvinyl chloride (PVC) and two of aluminum. For each frame, six different simulations were performed, two with a CFD code and four with a building-component thermal-simulation tool using the Finite Element Method (FEM). This FEM tool addresses convection using correlations from ISO 15099; it addressed radiation with either correlations from ISO 15099 or with a detailed, view-factor-based radiation model. Calculations were performed using the CFD code with and without fluid flow in the window frame cavities; the calculations without fluid flow were performed to verify that the CFD code and the building-component thermal-simulation tool produced consistent results. With the FEM-code, the practice of subdividing small frame cavities was examined, in some cases not subdividing, in some cases subdividing cavities with interconnections smaller than five millimeters (mm) (ISO 15099) and in some cases subdividing cavities with interconnections smaller than seven mm (a breakpoint that has been suggested in other studies). For the various frames, the calculated U-factors were found to be quite comparable (the maximum difference between the reference CFD simulation and the other simulations was found to be 13.2 percent). A maximum difference of 8.5 percent was found between the CFD simulation and the FEM simulation using ISO 15099 procedures. The ISO 15099 correlation works best for frames with high U-factors. For more efficient frames, the relative differences among various simulations are larger. Temperature was also compared, at selected locations on the frames. Small differences was found in the results from model to model. Finally, the effectiveness of the ISO cavity radiation algorithms was examined by comparing results from these algorithms to detailed radiation calculations (from both programs). Our results suggest that improvements in cavity heat transfer calculations can be obtained by using detailed radiation modeling (i.e. view-factor or ray-tracing models), and that incorporation of these strategies may be more important for improving the accuracy of results than the use of CFD modeling for horizontal cavities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Synthetic Hydrogel Composite with the Mechanical Behavior and Durability of Cartilage

Here, we report the first hydrogel with the strength and modulus of cartilage in both tension and compression, and the first to exhibit cartilage-equivalent tensile fatigue strength at 100 000 cycles. These properties are achieved by infiltrating a bacterial cellulose (BC) nanofiber network with a poly(vinyl alcohol) (PVA)–poly(2-acrylamido-2-methyl-1-propanesulfonic acid sodium salt) (PAMPS) double network hydrogel. The BC provides tensile strength in a manner analogous to collagen in cartilage, while the PAMPS provides a fixed negative charge and osmotic restoring force similar to the role of aggrecan in cartilage. The hydrogel has the same aggregate modulus and permeability as cartilage, resulting in the same time-dependent deformation under confined compression. The hydrogel is not cytotoxic, has a coefficient of friction 45% lower than cartilage, and is 4.4 times more wear-resistant than a PVA hydrogel. The properties of this hydrogel make it an excellent candidate material for replacement of damaged cartilage.

36 MATERIALS SCIENCE↗

Biocompatibility and Recanalization Characteristics of Hydrogel Microspheres with Polyzene-F as Polymer Coating

The objective of this study was to evaluate inflammatory response and recanalization after embolization with a new spherical embolic agent based on a core and shell design with a hydrogel core of polymethylmethacrylate (PMMA) and a Polyzene-F nanoscale coating in a porcine kidney model. Thirty-six minipigs were enrolled for superselective renal embolization. Polyzene-F-coated PMMA particles and uncoated PMMA particles with a diameter of 300-600 {mu}m were used. Either 4 or 12 weeks post-embolization, arteriography of the embolized kidneys was performed and then compared with pre- and immediate post-embolization arteriograms using a specific recanalization score to determine the extent of recanalization. Using a microscopic inflammation score (Banff classification), the embolized organs were examined for local inflammatory effects which occurred in response to the embolic agent. In Polyzene-F-coated particles, the Banff classification showed an average inflammation score of 0.26 {+-} 0.58 at 4 weeks and of 0.08 {+-} 0.28 at 12 weeks. In uncoated particles, the Banff score measured 0.37 {+-} 0.6 at 4 weeks, which was higher, but without a statistically significant difference. According to the recanalization score used in this study, mild angiographic recanalization was evident in all groups, without statistically significant differences (3.0 {+-} 0.71 in coated particles, 3.09 {+-} 0.81 in uncoated particles; p = 0.74). We conclude that both uncoated hydrogel particles and Polyzene-F-coated embolic agents triggered virtually no inflammatory response and effectively occluded target arteries. This study demonstrates good biocompatibility of the new embolic material. As in other spherical embolic agents, recanalization can occur to some degree.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Vertebroplasty and Bone Cement Leakage: Clinical Experience with a New High-Viscosity Bone Cement and Delivery System for Vertebral Augmentation in Benign and Malignant Compression Fractures

The aim of this study was to assess the feasibility of and venous leakage reduction in percutaneous vertebroplasty (PV) using a new high-viscosity bone cement (PMMA). PV has been used effectively for pain relief in osteoporotic and malignant vertebral fractures. Cement extrusion is a common problem and can lead to complications. Sixty patients (52 female; mean age, 72.2 {+-} 7.2) suffering from osteoporosis (46), malignancy (12), and angiomas (2), divided into two groups (A and B), underwent PV on 190 vertebrae (86 dorsal, 104 lumbar). In Group A, PV with high-viscosity PMMA (Confidence, Disc-O-Tech, Israel) was used. This PMMA was injected by a proprietary delivery system, a hydraulic saline-filled screw injector. In Group B, a standard low-viscosity PMMA was used. Postprocedural CT was carried out to detect PMMA leakages and complications. Fisher's exact test and Wilcoxon rank test were used to assess significant differences (p < 0.05) in leakages and to evaluate the clinical outcome. PV was feasible, achieving good clinical outcome (p < 0.0001) without major complications. In Group A, postprocedural CT showed an asymptomatic leak in the venous structures of 8 of 98 (8.2%) treated vertebrae; a discoidal leak occurred in 6 of 98 (6.1%). In Group B, a venous leak was seen in 38 of 92 (41.3%) and a discoidal leak in 12 of 92 (13.0%). Reduction of venous leak obtained by high-viscosity PMMA was highly significant (p < 0.0001), whereas this result was not significant (p = 0.14) related to the disc. The high-viscosity PMMA system is safe and effective for clinical use, allowing a significant reduction of extravasation rate and, thus, leakage-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Approach to Treatment of Unexpected Vertebroplasty Complication

We report a novel approach to treatment of an unexpected complication of vertebroplasty. During initial positioning of transpedicular vertebroplasty needles in a 73-year-old woman, we encountered unexpected ease of needle advancement resulting in progression of the needle through the anterior cortex of the thoracic vertebral body. The transpedicular needle advanced into the mediastinum and, presumably, the adventitia of the descending thoracic aorta. Administration of polymethylmethacrylate cement was performed to tamponade bleeding at the time of the procedure and to reduce the risk of potential delayed bleeding complications within the mediastinum. The treatment was successful and the patient had no immediate or delayed complications as a result of the unintended needle advancement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Extraspinal Painful Bone Metastases with Percutaneous Cementoplasty: A Prospective Study of 50 Patients

The aim of this study was to assess the efficacy of percutaneous cementoplasty (PC) with polymethylmethacrylate (PMMA) in painful extravertebral lytic bone metastases not responding to conventional therapy. Fifty patients (25 females), mean age 64.7 {+-} 11.2 years, underwent PC after giving informed consent. Procedures were performed under fluoroscopy (1/50) or combined fluoroscopy-CT (49/50) guidance in local anesthesia or under deep sedation in 7 patients with large metastases who underwent radiofrequency thermoablation (RFA) in the same session. Seventy lesions were treated (1-6 per patient; average, 1.4 {+-} 0.9), arranging in size from 1 to 10 cm (average, 3.6 {+-} 2.1 cm). Mean volume of PMMA per lesion was 5.9 {+-} 3.2 ml (range, 1.5-15.0 ml). Pain was prospectively evaluated on an 11-point visual analog scale (VAS) before and after the procedure (follow-up, 15 to 36 months). Mean VAS score dropped from 9.1 {+-} 1.2 (range: 6-10) to 2.1 {+-} 2.5 (range: 0-9). Mean VAS difference was 7.0 {+-} 2.3 (range, 1-10; p < 0.0001, Wilcoxon signed rank test). Forty-seven of the 50 patients (94%) suspended narcotic drugs, in 22 (44%) pain was controlled with a nonsteroidal anti-inflammatory drug, in 25 (50%) analgesic therapy was suspended, and 13 of 50 (26%) had complete pain regression. In 3 of the 50 patients (6%) pain was not improved. No statistical difference between osteoplasty and osteoplasty plus RFA was found (p = 0.8338, Mann-Whitney test). No complications arose during the procedure. Two patients with metastases in the femoral diaphysis reported a fracture 1 month after treatment. PC is effective to obtain pain regression in painful bone metastases not responding to conventional analgesic therapy; bone consolidation cannot be obtained in the diaphysis of long weight-bearing bones.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Midterm Follow-Up of Vertebral Geometry and Remodeling of the Vertebral Bidisk Unit (VDU) After Percutaneous Vertebroplasty of Osteoporotic Vertebral Fractures

The purpose of this study was to investigate geometrical stability and preservation of height gain of vertebral bodies after percutaneous vertebroplasty during 2 years' follow-up and to elucidate the geometric remodeling process of the vertebral bidisk unit (VDU) of the affected segment. Patients with osteoporotic vertebral compression fractures with pain resistant to analgetic drugs were treated with polymethylmethacrylate vertebroplasty. Mean {+-} standard error cement volume was 5.1 {+-} 2.0 ml. Vertebral geometry was documented by sagittal and coronal reformations from multidetector computed tomography data sets: anterior, posterior, and lateral vertebral heights, end plate angles, and compression index (CI = anterior/posterior height). Additionally, the VDU (vertebral bodies plus both adjacent disk spaces) was calculated from the multidetector computed tomography data sets: anterior, posterior, and both lateral aspects. Patients were assigned to two groups: moderate compression with CI of >0.75 (group 1) and severe compression with CI of <0.75 (group 2). A total of 83 vertebral bodies of 30 patients (7 men, 23 women, age 70.7 {+-} 9.7 years, range 40-82 years) were treated with vertebroplasty and prospectively followed for 24 months. In the moderate compression group (group 1), the vertebral heights were stabilized over time at the preinterventional levels. Compared with group 1, group 2 showed a greater anterior height gain (+2.8 {+-} 2.2 mm vs. +0.8 {+-} 2.0 mm, P < 0.001), better reduction of end plate angle (-4.9 {+-} 4.8{sup o} vs. -1.0 {+-} 2.7{sup o}, P < 0.01), and improved CI (+0.12 {+-} 0.13 vs. +0.02 {+-} 0.07, P < 0.01) and demonstrated preserved anterior height gain at 2 years (+1.2 {+-} 3.2 mm, P < 0.01) as well as improved end plate angles (-5.2 {+-} 5.0{sup o}, P < 0.01) and compression indices (+0.11 {+-} 0.15, P < 0.01). Thus, posterior height loss of vertebrae and adjacent intervertebral disk spaces contributed to a remodeling of the VDU, resulting in some compensation of the kyphotic malposition of the affected vertebral segment. Vertebroplasty improved vertebral geometry during midterm follow-up. In severe vertebral compression, significant height gain and improvement of end plate angles were achieved. The remodeling of the VDUs contributes to reduction of kyphosis and an overall improvement of the statics of the spine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Occlusion of an Intraosseous Arteriovenous Malformation With Percutaneous Injection of Polymethylmethacrylate

Primary intraosseous arteriovenous malformations are rare. Many minimally invasive procedures can be considered preoperative steps and/or definitive treatment. The case reported regards a young woman with a voluminous arteriovenous extratroncular infiltrating malformation of the humerus. She underwent several treatments, but none of them was completely occlusive. The last treatment consisted of direct percutaneous puncture of the intraosseous alteration and injection of polymethylmethacrylate (PMMA), which is normally used in percutaneous vertebroplasty. We obtained complete occlusion of the humerus lytic lesion. To the best of our knowledge, this represents the first case of intraosseous AVM treated by percutaneous injection of PMMA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗