Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

SU-E-CAMPUS-J-05: Quantitative Investigation of Random and Systematic Uncertainties From Hardware and Software Components in the Frameless 6DBrainLAB ExacTrac System

Purpose: To evaluate setup accuracy and quantify individual systematic and random errors for the various hardware and software components of the frameless 6D-BrainLAB ExacTrac system. Methods: 35 patients with cranial lesions, some with multiple isocenters (50 total lesions treated in 1, 3, 5 fractions), were investigated. All patients were simulated with a rigid head-and-neck mask and the BrainLAB localizer. CT images were transferred to the IPLAN treatment planning system where optimized plans were generated using stereotactic reference frame based on the localizer. The patients were setup initially with infrared (IR) positioning ExacTrac system. Stereoscopic X-ray images (XC: X-ray Correction) were registered to their corresponding digitally-reconstructed-radiographs, based on bony anatomy matching, to calculate 6D-translational and rotational (Lateral, Longitudinal, Vertical, Pitch, Roll, Yaw) shifts. XC combines systematic errors of the mask, localizer, image registration, frame, and IR. If shifts were below tolerance (0.7 mm translational and 1 degree rotational), treatment was initiated; otherwise corrections were applied and additional X-rays were acquired to verify patient position (XV: X-ray Verification). Statistical analysis was used to extract systematic and random errors of the different components of the 6D-ExacTrac system and evaluate the cumulative setup accuracy. Results: Mask systematic errors (translational; rotational) were the largest and varied from one patient to another in the range (−15 to 4mm; −2.5 to 2.5degree) obtained from mean of XC for each patient. Setup uncertainty in IR positioning (0.97,2.47,1.62mm;0.65,0.84,0.96degree) was extracted from standard-deviation of XC. Combined systematic errors of the frame and localizer (0.32,−0.42,−1.21mm; −0.27,0.34,0.26degree) was extracted from mean of means of XC distributions. Final patient setup uncertainty was obtained from the standard deviations of XV (0.57,0.77,0.67mm,0.39,0.35,0.30degree). Conclusion: Statistical analysis was used to calculate cumulative and individual systematic errors from the different hardware and software components of the 6D-ExacTrac-system. Patients were treated with cumulative errors (<1mm,<1degree) with XV image guidance.

60 APPLIED LIFE SCIENCES↗

Relatively scaled ECE temperature profiles of KSTAR plasmas

A scheme to obtain relatively scaled profiles of electron cyclotron emission (ECE) temperature directly from uncalibrated raw radiometer data is proposed and has been tested for the 2009 campaign KSTAR plasmas. The proposed method utilizes a position controlled system to move the plasma adiabatically and compares ECE radiometer channels at the same relative radial positions assuming the profile consistency during the adiabatic change. This scaling method is an alternative solution when an absolute calibration is unreliable or too time consuming. The application to the two dimensional ECE imaging data, wherein calibration is extremely difficult, may also prove to be useful.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of local position invariance using a double-cavity laser system

The results of testing local position invariance, which is a constituent of the Einstein equivalence principle, in a 'null' gravitational redshift experiment are reported. The processing of the experimental data collected during the five-month operation of a double-c avity laser system, where one cavity operates in the free generation mode and the frequency of the second cavity is stabilized with the nonlinear ultranarrow absorption resonance of the methane molecule, has confirmed the universality of the gravitational redshift law at a level of 0.9%. This result almost doubly improves the best existing accuracy (1.7%) of testing local position invariance for clocks of different physical natures.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-482: In Vivo Dosimetry of An Anthropomorphic Phantom by Using the RADPOS System for Proton Beam Therapy

Purpose: Delivered doses in an anthropomorphic phantom were evaluated by using the RADPOS system for proton beam therapy. Methods: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing simultaneous online measurements of dose and spatial position. Through the RADPOS system, dose evaluation points can be determined. In vivo proton dosimetry was evaluated by using the RADPOS system and anthropomorphic head and neck phantom. MOSFET doses measured at 3D positions obtained with the RADPOS were compared to the treatment plan values that were calculated by a simplified Monte Carlo (SMC) method. Although the MOSFET response depends strongly on the linear energy transfer (LET) of proton beam, the MOSFET responses to proton beams were corrected with the SMC. Here, the SMC calculated only dose deposition determined by the experimental depth–dose distribution and lateral displacement of protons due to both multiple scattering effect in materials and incident angle. As a Result, the SMC could quickly calculate accurate doses in even heterogeneities. Results: In vivo dosimetry by using the RADPOS, as well as the MOSFET doses agreed in comparison with calculations by the SMC in the range of −3.0% to 8.3%. Most measurement errors occurred because of the uncertainties of dose calculations due to the position error of 1 mm. Conclusion: We evaluated the delivered doses in the anthropomorphic phantom by using the RADPOS system for proton beam therapy. The MOSFET doses agreed in comparison with calculations by the SMC within the measurement error. Therefore, we could successfully control the uncertainties of the measurement positions by using the RADPOS system within 1 mm in in vivo proton dosimetry. We aim for the clinical application of in vivo proton dosimetry with this RADPOS system.

60 APPLIED LIFE SCIENCES↗

The art and power of data imaging

Data imaging and visual data assessment are veritable gold mines in the scientist's quest to understand and accurately interpret numerical data. Graphical displays of various aspects of a dataset offer the analyst insight to the data that no mathematical computation or statistic can provide. It is difficult, at best, for even a skilled and observant statistician to understand the underlying structure of a dataset. Often, there is either too little data to get a good 'picture' of the structure that might be present or there is so much data that one cannot readily assimilate it. Of course, the latter problem (too much data) is, in reality, no problem at all given the abilities of modern computers and software systems to manage large amounts of data. Advances in computer technology and the advent of the global positioning satellite system have enabled scientists from many fields of endeavor to collect and view data in its spatial context. Visual images constructed from spatially referenced data reveal the inherent richness and structure in the data and lead to more informed conclusions. So powerful is data collected with spatial context that a relatively new branch of mathematical statistics, geo-spatial statistics, has emerged. Geo-spatial statistics seek to exploit this context rich data form to better understand the spatial and co-relationships that might exist, but would be otherwise hidden in tabular data or obscured with classic statistical approaches. This paper (and accompanying presentation) will show the power that visual data assessment possesses to understand radiological scanning data and to make confident and accurate decisions based on the data images. It will challenge the traditional mathematical concept of detection limits for scanning. It will demonstrate that more data, even if the individual datum comprising the dataset is of 'poorer quality' (i.e., has a larger uncertainty and, thus, a larger calculated minimum detection value), is significantly more powerful than a smaller dataset comprised of higher quality measurements. This presentation will cause the open-minded health physicist to rethink how they prescribe, collect, evaluate, and make decisions based upon radiological scan data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE PROGENITOR OF SUPERNOVA 2011dh/PTF11eon IN MESSIER 51

We have identified a luminous star at the position of supernova (SN) 2011dh/PTF11eon, in pre-SN archival, multi-band images of the nearby, nearly face-on galaxy Messier 51 (M51) obtained by the Hubble Space Telescope with the Advanced Camera for Surveys. This identification has been confirmed, to the highest available astrometric precision, using a Keck-II adaptive-optics image. The available early-time spectra and photometry indicate that the SN is a stripped-envelope, core-collapse Type IIb, with a more compact progenitor (radius {approx} 10{sup 11} cm) than was the case for the well-studied SN IIb 1993J. We infer that the extinction to SN 2011dh and its progenitor arises from a low Galactic foreground contribution, and that the SN environment is of roughly solar metallicity. The detected object has absolute magnitude M{sup 0}{sub V} Almost-Equal-To -7.7 and effective temperature {approx}6000 K. The star's radius, {approx}10{sup 13} cm, is more extended than what has been inferred for the SN progenitor. We speculate that the detected star is either an unrelated star very near the position of the actual progenitor, or, more likely, the progenitor's companion in a mass-transfer binary system. The position of the detected star in a Hertzsprung-Russell diagram is consistent with an initial mass of 17-19 M{sub Sun }. The light of this star could easily conceal, even in the ultraviolet, the presence of a stripped, compact, very hot ({approx}10{sup 5} K), nitrogen-rich Wolf-Rayet star progenitor.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Development and Applications of a Two-dimensional Tip-Tilting Stage System with Nanoradian-Level Positioning Resolution

In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sketching Algorithms in Distributed Systems

In this position paper, we discuss exciting recent advancements in sketching algorithms applied to distributed systems. That is, we look at randomized algorithms that simultaneously reduce the data dimensionality, offer potential privacy benefits, while maintaining verifiably high levels of algorithm accuracy and performance in multi-node computational setups. We look at next steps and discuss the applicability to real systems.

97 MATHEMATICS AND COMPUTING↗

Model Reduction by Generalized Falk Method for Efficient Field-Circuit Simulations

The Generalized Falk Method (GFM) for coordinate transformation, together with two model-reduction strategies based on this method, are presented for efficient coupled field-circuit simulations. Each model-reduction strategy is based on a decision to retain specific linearly-independent vectors, called trial vectors, to construct a vector basis for coordinate transformation. The reduced-order models are guaranteed to be stable and passive since the GFM is a congruence transformation of originally symmetric positive definite systems. We also show that, unlike the Pad´e-via-Lanczos (PVL) method, the GFM does not generate unstable positive poles while reducing the order of circuit problems. Further, the proposed GFM is also faster when compared to methods of the type Lanczos (or Krylov) that are already widely used in circuit simulations for electrothermal and electromagnetic problems. The concept of response participation factors is introduced for the selection of the trial vectors in the proposed model-reduction methods. Further, we present methods to develop simple equivalent circuit networks for the field component of the overall field-circuit system. The implementation of these equivalent circuit networks in circuit simulators is discussed. With the proposed model-reduction strategies, significant improvement on the efficiency of the generalized Falk method is illustrated for coupled field-circuit problems.

42 ENGINEERING↗

Optical measurements for turbulence characterization in RFX-mod edge

The edge of the reversed field pinch experiment RFX-mod (R=2 m, a=0.46 m) is characterized by a complex magnetic topology and strong pressure gradients. A set of fast spectroscopic diagnostics has been designed to characterize both main plasma edge parameters and turbulence, including coherent structures (blobs) and radial profiles of the thermodynamic variables. Measurements of the edge radial profiles of electron density (n{sub e}), temperature (T{sub e}), and pressure (P{sub e}) are obtained by a thermal helium beam diagnostic, which locally measures the ratios of the spectral lines emitted by a neutral He cloud puffed into hydrogen plasma discharges. A gas puff imaging system allows the high frequency (1 MHz bandwidth) measurement of the fluctuations of He I emissivity in the same positions. The system measures both the intermittent behavior of the edge turbulence and n{sub e}, T{sub e}, and P{sub e} profiles of the corresponding coherent structures, with a resolution down to 6 {mu}s. The optical diagnostics are complemented by a set of triaxial magnetic coils to simultaneously characterize the edge magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generic solar photovoltaic system dynamic simulation model specification

This document is intended to serve as a specification for generic solar photovoltaic (PV) system positive-sequence dynamic models to be implemented by software developers and approved by the WECC MVWG for use in bulk system dynamic simulations in accordance with NERC MOD standards. Two specific dynamic models are included in the scope of this document. The first, a Central Station PV System model, is intended to capture the most important dynamic characteristics of large scale (> 10 MW) PV systems with a central Point of Interconnection (POI) at the transmission level. The second, a Distributed PV System model, is intended to represent an aggregation of smaller, distribution-connected systems that comprise a portion of a composite load that might be modeled at a transmission load bus.

14 SOLAR ENERGY↗

Model Validation and Demonstration of a Hydrogen Fuel Cell Parcel Delivery Truck

With an emphasis on reducing fossil fuel consumption and emissions, major delivery service corporations have begun deploying and operating Class 6 battery electric delivery vans. Fuel cell hybrid delivery vans offer a zero emissions solution with extended range and route planning flexibility. This paper follows a prior publication [1] on the vehicle modeling and design and presents demonstration data and a validation of the prior modeling and design effort. Here, the validation exercise shows that the modeling tools predict performance and energy efficiency within 5% for most of the routes, while the demonstration data shows that in service operation fuel economy was over 14 km/kg of hydrogen gas. In addition, results from a range test showed the vehicle design and onboard hydrogen storage was able to surpass the design target range of 200 km.

08 HYDROGEN↗

SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin, Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion: The initial BrainLAB IR system based on rigidity of the mask-frame setup is not sufficient for accurate stereotactic positioning; however, with X-ray imageguidance sub-millimeter accuracy is achieved with negligible deviations in dose coverage. The angular corrections (mean angle summation=1.84°) are important and cause considerable deviations in dose coverage.

60 APPLIED LIFE SCIENCES↗

Analog Systems for Edge Optimization

Over the past decade, analog computing has the subject of substantial research interest providing a path toward improved computational efficiency in the post-Dennard era. Analog matrix vector multiplication (MVM) accelerators provide a popular approach given the ubiquity of MVM operations in numerous applications. However, historically analog computing systems can struggle with applications requiring high precision due to the inherent susceptibility of these systems to analog non-idealities. Therefore, prior work on analog systems has focused either on applications known to be tolerant of limited precision (e.g., neural network inference), or using expensive techniques to emulate high-precision using many analog MVM operations. In this work, we propose an alternative approach. Motivated by recent advances in inexact nonlinear solvers and optimizers, we explore the potential of co-designing optimization algorithms which can take full advantage of the fundamentally inexact analog MVM operations. To enable these co-designed algorithms we also develop a general mathematical theory of the precision and energy efficiency of analog operations, and a new system architecture for tightly-coupled analog and digital computation. Finally, we examine the applicability of analog computing to a wider class of symmetric positive definite systems and find potential in using analog operations as a sparse approximate inverse preconditioner. With these core innovations, this project provides a path toward effectively implementing optimization algorithms on power-constrained autonomous and semi-autonomous systems.

97 MATHEMATICS AND COMPUTING↗

Operating characteristics of a new ion source for KSTAR neutral beam injection system

A new positive ion source for the Korea Superconducting Tokamak Advanced Research neutral beam injection (KSTAR NBI-1) system was designed, fabricated, and assembled in 2011. The characteristics of the arc discharge and beam extraction were investigated using hydrogen and helium gas to find the optimum operating parameters of the arc power, filament voltage, gas pressure, extracting voltage, accelerating voltage, and decelerating voltage at the neutral beam test stand at the Korea Atomic Energy Research Institute in 2012. Based on the optimum operating condition, the new ion source was then conditioned, and performance tests were primarily finished. The accelerator system with enlarged apertures can extract a maximum 65 A ion beam with a beam energy of 100 keV. The arc efficiency and optimum beam perveance, at which the beam divergence is at a minimum, are estimated to be 1.0 A/kW and 2.5 uP, respectively. The beam extraction tests show that the design goal of delivering a 2 MW deuterium neutral beam into the KSTAR Tokamak plasma is achievable.

43 PARTICLE ACCELERATORS↗