A low noise switching converter-regulator for main power control in a space power system
Variable ratio dc transformer regulator used to process main vehicle power from solar array battery power system in radio astronomy explorer spacecraft
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Variable ratio dc transformer regulator used to process main vehicle power from solar array battery power system in radio astronomy explorer spacecraft
Accuracy requirements for the SPS antenna pointing control consists of a mechanical pointing accuracy of three arc minutes and an electronic phased array pointing accuracy of three arc seconds. Results of this study, based on the factors considered in current analysis, show that the three arc minute overall pointing control accuracy can be achieved for the SPS in practice.
Explore the source record for details and available documents.
There is provided a climate control system for a parked vehicle that includes a solar panel, thermostatic switch, fans, and thermoelectric coolers. The solar panel can serve as the sole source of electricity for the system. The system affords convenient installation and removal by including solar panels that are removably attached to the exterior of a vehicle. A connecting wire electrically connects the solar panels to a housing that is removably mounted to a partially opened window on the vehicle. The thermostatic switch, fans, and thermoelectric coolers are included within the housing. The thermostatic switch alternates the direction of the current flow through the thermoelectric coolers to selectively heat or cool the interior of the vehicle. The interior surface of the thermoelectric coolers are in contact with interior heat sinks that have air circulated across them by an interior fan. Similarly, the exterior surface of the thermoelectric coolers are in contact with exterior heat sinks that have air circulated across them by an exterior fan.
No abstract provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.
The solar power satellite (SPS) concept envisions several hundred thousand synchronized microwave power amplifiers operating in parallel to produce an aggregate power output of 5-10 GW. This power is to be transferred to earth with the aid of a microwave/millimeter-wave beaming system operating in a synchronous orbit. The reference phase control system is considered along with aspects of pilot signal parameter selection. A power transponder analysis is conducted and an SPS performance evaluation is performed. Attention is given to system jitters and imperfections, the definition of power transfer efficiency, and the effects of system imperfections on SPS efficiency. It is found that the power transfer efficiency is relatively insensitive to the amplitude jitters. However, the effects of location jitters can produce a severe degradation of efficiency.
This paper presents a digitally controlled programmable point-of-load regulator for next-generation power systems. A novel digital control scheme was designed to minimize single-event effect (SEE)-induced transient effects. By effectively programming the loop transmission, the POL can trade off transient response time with SET robustness. The IC works with 1 to 5.5 V input voltage, 1-4.5V regulated output voltage, high efficiency (peak efficiency at 94%) and power of up to 5 W. The design was fabricated in the AMI i2t100 0.7 mu m complimentary, metal-oxide semiconductor (CMOS) process and characterized with the Jet Propulsion Laboratory (JPL) pulsed laser system.
This talk will present the work which has been done at NASA Marshall Space Flight Center involving the use of Artificial Intelligence to control the power system in a spacecraft. The presentation will include a brief history of power system automation, and some basic definitions of the types of artificial intelligence which have been investigated at MSFC for power system automation. A video tape of one of our autonomous power systems using co-operating expert systems, and advanced hardware will be presented.
This paper presents duty control and analysis of the three-phase voltage source inverter (VSI) to adjust the output power for three-phase wireless power transfer (WPT) applications. Analytical results show significant reductions in the inverter dc link ripple current with the three-phase system over single-phase WPT counterparts. Simulation and experimental results for an 18 kW three-phase series-series WPT system are included to validate the duty control and analysis. Experimental results also demonstrated the output voltage can be controlled over a wide range by adjusting the inverter duty.
This paper presents the use of feedforward control to reduce the input side DC link capacitance of series-series compensated wireless power transfer (WPT) systems. Compared to conventional control schemes for WPT systems, the proposed feedforward-based approach achieves significant reduction in the DC link capacitor without any complicated voltage or current sensing requirements from the secondary side. This results in more compact hardware architecture. The proposed method shows minimal increase in the turn-on switching loss of the inverter. The switching loss is analyzed, and detailed results are presented relating the switching loss to the DC link capacitance and voltage ripple for proper tradeoff between losses and capacitor size. Simulation and experimental results presented validate the proposed scheme.
The NASA Marshall Space Flight Center (MSFC) has developed two autonomous electrical power system breadboards. The first breadboard, the autonomously managed power system (AMPS), is a two power channel system featuring energy generation and storage and 24-kW of switchable loads, all under computer control. The second breadboard, the space station module/power management and distribution (SSM/PMAD) testbed, is a two-bus 120-Vdc model of the Space Station power subsystem featuring smart switchgear and multiple knowledge-based control systems. NASA/MSFC is combining these two breadboards to form a complete autonomous source-to-load power system called the large autonomous spacecraft electrical power system (LASEPS). LASEPS is a high-power, intelligent, physical electrical power system testbed which can be used to derive and test new power system control techniques, new power switching components, and new energy storage elements in a more accurate and realistic fashion. LASEPS has the potential to be interfaced with other spacecraft subsystem breadboards in order to simulate an entire space vehicle. The two individual systems, the combined systems (hardware and software), and the current and future uses of LASEPS are described.
Here, this letter investigates the importance of integrating the coherency knowledge for designing controllers to dampen sustained oscillations in wide-area power networks with significant penetration of inverter-interfaced resources. Coherency is a fundamental property of power systems, where time-scale separation in frequency dynamics leads to clustered behavior among generators of different groups. Large-scale penetration of inverter-driven low inertia resources replacing conventional synchronous generators (SGs) can lead to perturbation in the coherent partitioning; hence, integrating such information is of utmost importance for oscillation control designs. We present the coherency-aware design of a distributed output feedback-based reinforcement learning method that additionally incorporates risk constraints to capture the uncertainties related to net-load fluctuations. The use of domain-aware coherency information has produced improved training and oscillation performance than the coherency-agnostic control design, hence proving to be effective in controller design. Finally, we validated the proposed method with numerical experiments on the benchmark IEEE 68-bus test system.
In legacy control rooms the operators might have 20 to 30 alarms to deal with on 12 control boards, during a reactor trip. The new digital alarm system in the upgraded control room will display between 150 and 200 alarm points on a single screen. This overload of information prevents the operators from identifying any abnormal alarms quickly without having to scroll through the alarm list looking for the abnormal alarms. One way to tackle this problem could be to attempt to create a state-based alarm system which would identify plant states and would identify which alarms are expected in those states and suppress them from the alarm screen so that any unexpected alarms would be displayed and easily identified to the operators. This can be done today but is very labor intensive in that an operator or training instructor would be required to run scenarios and log the alarms to be suppressed. The hope is that Machine Learning (ML) can provide an alternative solution with less manual effort required.
The use of radioisotope thermoelectric generators (RTG) as the primary source of energy in unmanned spacecraft is discussed. RTG output control, power conditioning system requirements, the electrical design, and circuit performance are also discussed.
With the rise of inverter-based resources (IBRs) within the power system, the control of grid-connected converters (GCCs) has become pertinent due to the fact they interface IBRs to the grid. The conventional method of control for a GCC such as the voltage-sourced converter (VSC) is through a decoupled control loop in the synchronous reference frame. However, this model-based control method is sensitive to parameter changes causing deterioration in controller performance. Data-driven approaches such as machine learning can be utilized to design controllers that are capable of operating GCCs in various system conditions. This work explores a deep learning-based control method for a three-phase grid-connected VSC, specifically utilizing a long short-term memory (LSTM) network for robust control. Simulations of a conventional controlled VSC are conducted using Simulink to collect data for training the LSTM-based controller. The LSTM model is built and trained using the Keras and TensorFlow libraries in Python and tested in Simulink. The performance of the LSTM-based controller is evaluated under different case studies and compared to the conventional method of control. Simulation results demonstrate the effectiveness of this approach by outperforming the conventional controller and maintaining stability under different system parameter changes.