Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid (Spanish Version)

This is the Spanish version of 'Greening the Grid - Integrating Variable Renewable Energy into the Grid: Key Issues'. To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, and Planning for a High RE Future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Critical Coupling in High-Power Resonant Systems

Power reflections are a fundamental challenge in high-power resonant systems, causing energy loss, limiting per- formance, and potentially damaging critical components. This problem is particularly acute in applications such as lower hybrid current drive (LHCD) for tokamak-based nuclear fusion, where efficient, stable power transfer to the plasma is paramount. In this work, we introduce and experimentally demonstrate the virtual critical coupling (VCC) mechanism, a nonmechanical method to achieve reflection-free excitation in high-power S-band resonators. VCC utilizes a temporally shaped excitation signal with a precise complex frequency, tailored to the resonator’s characteristics to enable complete energy absorption. Using a custom low-level RF system and a 5-MW S-band klystron, we conducted experiments from low power (32 mW) to high power (600 kW). Furthermore, the results demonstrate a greater than ninefold reduction in the reflection coefficient compared to conventional monochromatic excitation. This signal processing-based approach offers a robust path toward enhancing the efficiency and stability of high-power resonant systems, with significant implications for particle accelerators and the advancement of nuclear fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, Planning for a High RE Future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aqueous titanium redox flow batteries—State-of-the-art and future potential

Market-driven deployment of inexpensive (but intermittent) renewable energy sources, such as wind and solar, in the electric power grid necessitates grid-stabilization through energy storage systems Redox flow batteries (RFBs), with their rated power and energy decoupled (resulting in a sub-linear scaling of cost), are an inexpensive solution for the efficient electrochemical storage of large amounts of electrical energy. Titanium-based RFBs, first developed by NASA in the 1970s, are an interesting albeit less examined chemistry and are the focus of the present review. Ti, constituting 0.6% of the Earth’s crust and an ingredient in inexpensive white paints, is amongst the few elements (V and Mn being some others) which exhibit multiple soluble oxidation states in aqueous electrolytes. Further, the very high (approaching 10 M) solubility of Ti in low pH solutions suggests the possibility of developing exceptionally high energy density aqueous Redox Flow Batteries systems. With these advantages in mind, we present the state-of the-art in Ti-RFBs with a focus on Ti/Mn, Ti/Fe and Ti/Ce couples and systems that use Ti as an additive (such as Ti/V/Mn). The inherent advantages of inexpensive Ti actives and relatively high energy density is contrasted with potential side-reactions resulting in reduced energy efficiency. Technological pathways are presented with a view to overcoming critical bottlenecks and a vision is presented for the future development of Ti-RFBs.

25 ENERGY STORAGE↗

Optimal Wind Power Uncertainty Intervals for Electricity Market Operation

It is important to select an appropriate uncertainty level of the wind power forecast for power system scheduling and electricity market operation. Traditional methods hedge against a predefined level of wind power uncertainty, such as a specific confidence interval or uncertainty set, which leaves the questions of how to best select the appropriate uncertainty levels. To bridge this gap, this paper proposes a model to optimize the forecast uncertainty intervals of wind power for power system scheduling problems, with the aim of achieving the best trade-off between economics and reliability. Then we reformulate and linearize the models into a mixed integer linear programming (MILP) without strong assumptions on the shape of the probability distribution. In order to invest the impacts on cost, reliability, and prices in a electricity market, we apply the proposed model on a twosettlement electricity market based on a six-bus test system and on a power system representing the U.S. state of Illinois. The results show that the proposed method can not only help to balance the economics and reliability of the power system scheduling, but also help to stabilize the energy prices in electricity market operation.

electricity market↗

Transient Stability of the US Western Interconnection with High Wind and Solar Generation

The addition of large amounts of wind and solar generation to bulk power systems that are traditionally subject to operating constraints set by transient limitations is the subject of considerable concern in the industry. The US Western Interconnection (WI) is expected to experience substantial additional growth in both wind and solar generation. These plants will, to some extent, displace large central station thermal generation, both coal and gas-fired, which have traditionally helped maintain stability. This paper reports the results of a study that investigated the transient stability of the WI with high penetrations of wind and solar generation. The main goals of this work were to (1) create a realistic, baseline model of the WI, (2) test selected transient stability events, (3) investigate the impact of large amounts of wind and solar generation, and (4) examine means to improve performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal Wide-area Damping Control for Mitigating Inter-area Oscillations in Power Systems

The active damping of inter-area oscillations of low frequencies has been successfully demonstrated to improve the dynamic response of the power grid in a satisfactory manner. It also enhances the system stability and reliability as well. The existence of inter-area oscillations has already become one of the key challenges in large-scale interconnected power grids because they are detrimental to the achievement of maximum power transfer and optimal power flow. This project focuses on the development of a universal damping control based on phasor measurements so that it can be easily implemented by a mix of various fast-acting resources to effectively mitigate inter-area oscillations. With the proposed advanced damping control strategies, the power grid stability and reliability can be managed in a much more flexible manner by utilizing different resources that are geographically dispersed in both the transmission and distribution systems. Moreover, higher power transfer capacity can be also achieved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of microgrid resilience through co-simulation of power system dynamics and communication systems

The interdependence of power and communication systems in smart grid technologies is acknowledged, but difficult to quantify. Communication systems can be essential to maintaining stability in microgrids that are islanded due to extreme events. Though many power system studies assume the presence of communication networks, detailed modeling of power and communication systems for dynamic studies of microgrids is rare. The work presented in this paper develops a framework for power and communication system co-simulation to study the impact of communications system on microgrid stability. An operational use case is examined where a battery energy storage system operates to offset the loss of generation in an islanded microgrid. The framework is evaluated for different communication technologies, network structures, and communication media.

Thekkumparambath Mana, Priya↗

Integrating Variable Renewable Energy - Russia

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, Planning for a High RE Future. This is a Russian-language translation of Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid, originally published in English in May 2015.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control system design method

A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.

47 OTHER INSTRUMENTATION↗

Phasor Measurement Unit and Its Application in Modern Power Systems

The introduction of phasor measuring units (PMUs) in power systems significantly improves the possibilities for monitoring and analyzing power system dynamics. Synchronized measurements make it possible to directly measure phase angles between corresponding phasors in different locations within the power system. Improved monitoring and remedial action capabilities allow network operators to utilize the existing power system in a more efficient way. Improved information allows fast and reliable emergency actions, which reduces the need for relatively high transmission margins required by potential power system disturbances. In this chapter, the applications of PMU in modern power systems are presented. Specifically, the topics touched in this chapter include state estimation, voltage and transient stability, oscillation monitoring, event and fault detection, situation awareness, and model validation. A case study using Characteristic Ellipsoid method based on PMU to monitor power system dynamic is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress in L-Band Power Distribution System R&D at SLAC

We report on the L-band RF power distribution system (PDS) developed at SLAC for Fermilab's NML superconducting test accelerator facility. The makeup of the system, which allows tailoring of the power distribution to cavities by pairs, is briefly described. Cold test measurements of the system and the results of high power processing are presented. We also investigate the feasibility of eliminating the expensive, lossy circulators from the PDS by pair-feeding cavities through custom 3-dB hybrids. A computational model is used to simulate the impact on cavity field stability due to the reduced cavity-to-cavity isolation.

43 PARTICLE ACCELERATORS↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems: Preprint

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Impact of Inverter-Interfaced Renewable Generation on Transient Stability at Varying Levels of Penetration: Preprint

The transient dynamics of conventional power systems are dominated by synchronous generators, and low-inertia inverters serve as the primary interface between power systems and renewable energy resources. Increasing penetration levels of inverter-interfaced generation are impacting the transient dynamics of power systems. In this paper, we attempt to quantify these impacts at different penetration levels. An elementary system including one inverter, one synchronous generator, and one load is studied under different parameter variations to assess the transient dynamics of the system. To quantify transient stability, the post-fault regions of attraction of the system are estimated by the sample-based basin stability approach with parallel computing technology. The simulation results suggest that different inverter penetration levels, inertias of the generator, inverter controller gains, and phase-locked loop controller gains have a clear impact on the regions of attraction as well as on the transient dynamics of proposed systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗