Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Electroformed Nickel Mirrors for the Next Generation Space Telescope

This paper summarizes the work to date on a novel mirror fabrication technique being developed at the Marshall Space Flight Center for potential use on the Next Generation Space Telescope (NGST). This technique involves forming an extremely lightweight mirror by electroplating nickel and nickel based alloys onto a highly polished precision mandrel. The resulting mirror shell can then be backed up with or attached to a lightweight structure to produce a mirror element that is on the order of 15 kg/sq m areal density. Since the mirrors are fabricated from a mandrel (or master), subsequent mirrors can be made with very high economy; this technique is particularly suited to segmented mirrors schemes whereby large apertures are achieved through the deployment of smaller segments. Control of the electroplating process is the key element for producing high quality optics; bath chemistry and real time control of the plating current density yields uniform grained electroforms with zero residual stress. To accomplish this, a special electronic sensor was developed whereby the residual stress can be monitored as the nickel is electrolytically deposited. This information is used in a feedback loop to modulate current density which, in turn, directly governs the residual stress. Details pertaining to this and other aspects of the fabrication of a half meter mirror will be published along with test results and metrology data.

Redmon, John W.↗

Non-Equilibrium Actinide Radiation Chemistry and the Nuclear Fuel Cycle

Actinides are inherently unstable elements that frequently coexist with other radioisotopes, generating intense ionizing radiation fields that drive the formation of non equilibrium oxidation states. These transient species exert a profound mechanistic influence on the radiation response of actinide containing systems due to their unique redox chemistry. Despite their importance, they remain poorly understood, yet such insight is essential for advancing actinide science and accurately predicting radiation driven behavior. Actinide separations—critical for nuclear energy technologies, strategic deterrence, space exploration, and nuclear medicine—depend on precise control of actinide oxidation states to recover targeted elements from complex matrices such as used nuclear fuel. However, during these processes, actinides, their coordination complexes, and the separation media are all exposed to intense, multicomponent (alpha, beta, gamma, etc.) radiation fields that can alter process efficiency, selectivity, and chemical stability. Understanding, controlling, and mitigating radiation induced reactions is therefore key to innovating and optimizing next generation separation technologies. This seminar will provide an overview of the nuclear fuel cycle and non equilibrium actinide radiation chemistry in the context of recovering actinides from used nuclear fuel, with a particular emphasis on direct dissolution–based reprocessing strategies. We will explore time resolved electron pulse radiolysis and alpha and gamma dose accumulation studies, integrated with multiscale computational modeling, to elucidate the molecular level roles of radiation driven, non equilibrium actinide species in process performance and in the radiolytic stability of organic ligands used for actinide recovery. These insights offer new pathways for designing advanced separation methods and next generation solvent systems, with broad implications for the future of the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Improving qubit coherence time through detailed materials analysis

This study investigates the defects, imperfections, and variations in superconducting Nb thin films deposited on sapphire substrates. Two samples, W114 and W118, were fabricated using DC Magnetron Sputtering and Electron Cyclotron Resonance (ECR), respectively. Each sample was analyzed at five distinct spots to compare elemental homogeneity and thickness variations. Scanning Electron Microscopy (SEM) was employed to examine surface morphology, while Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) provided elemental and chemical state analyses. SEM revealed distinct structures in W114 and a uniform surface in W118. EDS showed higher aluminum and oxygen signals in W118, indicating a thicker film. XPS detected a higher Nb₂O₅ signal in W118, attributed to a thicker oxygen layer. These findings highlight the critical role of precise material characterization in advancing quantum computing technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NANOGrav 12.5 Year Data Set: Monitoring Interstellar Scattering Delays

We extract interstellar scintillation parameters for pulsars observed by the NANOGrav radio pulsar timing program. Dynamic spectra for the observing epochs of each pulsar were used to obtain estimates of scintillation timescales, scintillation bandwidths, and the corresponding scattering delays using a stretching algorithm to account for frequency-dependent scaling. We were able to measure scintillation bandwidths for 28 pulsars at1500 MHz and 15 pulsars at 820 MHz. We examine scaling behavior for 17 pulsars and find power-law indices ranging from−0.7 to−3.6, though these may be biased shallow due to insufficient frequency resolution at lower frequencies. We were also able to measure scintillation timescales for six pulsars at 1500 MHz and seven pulsars at820 MHz. There is fair agreement between our scattering delay measurements and electron-density model predictions for most pulsars. We derive interstellar scattering-based transverse velocities assuming isotropic scattering and a scattering screen halfway between the pulsar and Earth. We also estimate the location of the scattering screens assuming proper motion and interstellar scattering-derived transverse velocities are equal. We find no correlations between variations in scattering delay and either variations in dispersion measure or flux density. For most pulsars for which scattering delays are measurable, we find that time-of-arrival uncertainties for a given epoch are larger than our scattering delay measurements, indicating that variable scattering delays are currently subdominant in our overall noise budget but are important for achieving precisions of tens of nanoseconds or less.

Jacob E Turner↗

SEDS1 mission software verification using a signal simulator

The first flight of the Small Expendable Deployer System (SEDS1) is schedule to fly as the secondary payload of a Delta 2 in March, 1993. The objective of the SEDS1 mission is to collect data to validate the concept of tethered satellite systems and to verify computer simulations used to predict their behavior. SEDS1 will deploy a 50 lb. instrumented satellite as an end mass using a 20 km tether. Langley Research Center is providing the end mass instrumentation, while the Marshall Space Flight Center is designing and building the deployer. The objective of the experiment is to test the SEDS design concept by demonstrating that the system will satisfactorily deploy the full 20 km tether without stopping prematurely, come to a smooth stop on the application of a brake, and cut the tether at the proper time after it swings to the local vertical. Also, SEDS1 will collect data which will be used to test the accuracy of tether dynamics models used to stimulate this type of deployment. The experiment will last about 1.5 hours and complete approximately 1.5 orbits. Radar tracking of the Delta II and end mass is planned. In addition, the SEDS1 on-board computer will continuously record, store, and transmit mission data over the Delta II S-band telemetry system. The Data System will count tether windings as the tether unwinds, log the times of each turn and other mission events, monitor tether tension, and record the temperature of system components. A summary of the measurements taken during the SEDS1 are shown. The Data System will also control the tether brake and cutter mechanisms. Preliminary versions of two major sections of the flight software, the data telemetry modules and the data collection modules, were developed and tested under the 1990 NASA/ASEE Summer Faculty Fellowship Program. To facilitate the debugging of these software modules, a prototype SEDS Data System was programmed to simulate turn count signals. During the 1991 summer program, the concept of simulating signals produced by the SEDS electronics systems and circuits was expanded and more precisely defined. During the 1992 summer program, the SEDS signal simulator was programmed to test the requirements of the SEDS Mission software, and this simulator will be used in the formal verification of the SEDS Mission Software. The formal test procedures specification was written which incorporates the use of the signal simulator to test the SEDS Mission Software and which incorporates procedures for testing the other major component of the SEDS software, the Monitor Software.

Pierson, William E.↗

Cryogenic Quenching Process for Electronic Part Screening

The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

Sheldon, Douglas J.↗

Spectral Addressability in a Modular Two Qubit System

The combination of structural precision and reproducibility of synthetic chemistry is perfectly suited for the creation of chemical qubits, the core units of a quantum information science (QIS) system. By exploiting the atomistic control inherent to synthetic chemistry, we address a fundamental question of how the spin–spin distance between two qubits impacts electronic spin coherence. To achieve this goal, in this study we designed a series of molecules featuring two spectrally distinct qubits, an early transition metal, Ti 3+ , and a late transition metal, Cu 2+ with increasing separation between the two metals. The spectral separation between the two metals enables us to probe each metal individually in the bimetallic species and compare it with monometallic control samples. Coherence times found to be governed by the distance to nuclear spins on the other qubit’s ligand framework. This finding offers guidance for the design of spectrally addressable molecular qubits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Equilibrium Actinide Radiation Chemistry and the Nuclear Fuel Cycle

Invited John and Naomi Fackler Lectureship in Chemistry and English seminar at Valparaiso University, IN, USA. Actinides are inherently unstable elements that frequently coexist with other radioisotopes, generating intense ionizing radiation fields that drive the formation of non-equilibrium oxidation states. These transient species exert a profound mechanistic influence on the radiation response of actinide-containing systems due to their unique redox chemistry. Despite their importance, they remain poorly understood, yet such insight is essential for advancing actinide science and accurately predicting radiation-driven behavior. Actinide separations—critical for nuclear energy technologies, strategic deterrence, space exploration, and nuclear medicine—depend on precise control of actinide oxidation states to recover targeted elements from complex matrices such as used nuclear fuel. However, during these processes, actinides, their coordination complexes, and the separation media are all exposed to intense, multicomponent (alpha, beta, gamma, etc.) radiation fields that can alter process efficiency, selectivity, and chemical stability. Understanding, controlling, and mitigating radiation-induced reactions is therefore key to innovating and optimizing next-generation separation technologies. This seminar will provide an overview of the nuclear fuel cycle and non-equilibrium actinide radiation chemistry in the context of recovering actinides from used nuclear fuel, with a particular emphasis on direct-dissolution–based reprocessing strategies. We will explore time-resolved electron pulse radiolysis and gamma dose accumulation studies to elucidate the molecular-level roles of radiation-driven, non-equilibrium actinide species in process performance and in the radiolytic stability of organic ligands used for actinide recovery. These insights offer new pathways for designing advanced separation methods and next-generation solvent systems, with broad implications for the future of the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Connection between Coherent Acoustic Phonons and Bright-Field Contrast in Ultrafast Electron Microscopy

Intense ultrafast photoexcitation of archetypal semiconducting materials, such as Ge and GaAs, ends in the rapid generation of large charge-carrier densities that propagate outward from the high-fluence region at initially hypersonic velocities. This produces a number of interesting effects that become interwoven with the underlying lattice; including the development of acoustic-type propagating oscillatory modes, excitation of coherent propagating strain waves, and coalescence of phase behaviors of the acoustic phonons and charge carriers via wave-particle drag. Using bright-field imaging in an ultrafast electron microscope, we directly imaged the behavior of photoexcited, nanoscale coherent strain waves in single-crystal Ge. In addition to single preferential wavevectors and initially hypersonic phase velocities (up to 35 nm/ps), we were able to directly resolve single-phonon constant velocities and an overall time-varying phase-velocity dispersion to the bulk speed of sound over approximately one nanosecond. Comparison to dispersion behaviors expected for symmetric and asymmetric Lamb-type modes showed good agreement with experiments, suggesting the preferential excitation of a single, symmetric first-order mode. Yet, quantitative comparison to the expected and measured contrast strengths associated with the coherent dynamics is needed in order to further elucidate the precise microscopic mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale ultrafast lattice modulation with a free-electron laser

Ultrafast optical laser-based techniques have enabled the probing of atomistic processes at their intrinsic temporal scales with femto- and attosecond resolution. However, the long wavelengths of optical lasers have prevented their interrogation and manipulation with nanoscale spatial specificity. Advances in hard X-ray free-electron lasers have enabled progress in developing X-ray transient-grating spectroscopy, a technique that aims to coherently control elementary excitations with nanoscale X-ray standing waves. Thus far, the realization of this technique at the nanoscale has been a challenge. Here we demonstrate X-ray transient-grating spectroscopy with spatial periods of the order of 10 nm via the subfemtosecond synchronization of two hard X-ray pump pulses at a precisely controlled crossing angle. This creates a thermal grating and preferentially excites coherent longitudinal acoustic phonon modes with the transient-grating wavevector. On probing with a third, variably delayed, X-ray pulse with the same photon energy, time-and-wavevector-resolved measurements of the modulation of the induced scattering intensity provide evidence of ballistic thermal transport at nanometre scales. Finally, these results highlight the potential of X-ray transient gratings as a powerful platform for studying nanoscale transport in condensed matter and the coherent control of nanoscale dynamics.

nonlinear optics↗

Two-dimensional ultraviolet imagery with a microchannel-plate/resistive-anode detector

An imaging ultraviolet detector has been designed for use with a precision pointed telescope flown on a sounding rocket. Resolution of better than 80 microns over a field of 5 mm has been achieved. The ultraviolet image is converted to electrons at the front surface of a CsI coated chevron microchannel-plate electron multiplier. For each photoelectron, the multiplier produces a burst of about 3,000,000 electrons, which impinges on a tellurium-coated resistive anode with four evaporated hyperbolic readout electrodes. The sizes of the four resulting output pulses are digitized to 10 bit accuracy and telemetered to the ground, where they are divided in pairs to give the x and y coordinates of the photoelectron event. The coordinates are used to generate a picture in real time, and are recorded for computer processing later. The detector was successfully flown in December 1978. Good images of Jupiter and Capella in hydrogen Lyman alpha emission were obtained.

Opal, C. B.↗

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

Formation of the oxyl’s potential energy surface by the spectral kinetics of a vibrational mode

One of the most reactive intermediates for oxidative reactions is the oxyl radical, an electron-deficient oxygen atom. The discovery of a new vibration upon photoexcitation of the oxygen evolution catalysis detected the oxyl radical at the SrTiO3 surface. The vibration was assigned to a motion of the sub-surface oxygen underneath the titanium oxyl (Ti–O●−) created upon hole transfer to (or electron extraction from) a hydroxylated surface site. Evidence for such an interfacial mode is derived from its spectral shape, which exhibited a Fano resonance—a coupling of a sharp normal mode to continuum excitations. Here, this Fano resonance is utilized to derive precise formation kinetics of the oxyl radical and its associated potential energy surface (PES). From the Fano lineshape, the formation kinetics are obtained from the anti-resonance (the kinetics of the coupling factor), the resonance (the kinetics of the coupled continuum excitations), and the frequency integrated spectrum (the kinetics of the normal mode’s cross-section). All three perspectives yield logistic function growth with a half-rise of 2.3 ± 0.3 ps and a time constant of 0.48 ± 0.09 ps. A non-equilibrium transient associated with photoexcitation is separated from the rise of the equilibrated PES. The logistic function characterizes the oxyl coverage at the very initial stages (t ∼ 0) to have an exponential growth rate that quickly decreases toward zero as a limiting coverage is reached. Such time-dependent reaction kinetics identify a dynamic activation barrier associated with the formation of a PES and quantify it for oxyl radical coverage.

Chemistry↗

New MeV-Scale Capabilities in Large Neutrino LArTPCs Using Ambient Radiogenic and Cosmogenic Activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing and interpreting MeV-scale energy depositions present in their data. We use data from MicroBooNE, an 85 tonnes LArTPC exposed to Fermilab neutrino beams from 2015 until 2021, to demonstrate new calorimetric and particle discrimination capabilities for isolated $\sim \mathrm{O}(1 \mathrm{MeV})$ energy depositions referred to as blips. We observe a concentration of low energy ( $<3$ MeV ) blips around fiberglass mechanical support struts along the TPC edges with energy spectrum features consistent with the Compton edge of 2.614 MeV Tl-208 decay gamma rays. These features are used to verify proper calibration of electron energy scales in MicroBooNE's data to few percent precision and to measure the specific activity of Tl-208 in the fiberglass composing these struts. Cosmogenicallyproduced blips above 3 MeV in reconstructed energy are used to showcase the ability of large LArTPCs to distinguish between low-energy proton and electron energy depositions.

Andrade Aldana, Diego Armando↗

Precise measurement of the nuclear dependence of the EMC effect in light nuclei

Measurements of inclusive electron scattering cross-section ratios from light nuclei over a wide range of the Björken G (0.3 ? G ? 1) up to &2 = 8.3 GeV2 were made as part of experiment E10-10-008, which was conducted in Hall C at the Thomas Jefferson National Accelerator Facility. The measurements were performed using a beam energy of 10.602 GeV and an average beam current of 45 `A. This dissertation provides a thorough description of the experiment as well as the extracted ratios of inclusive nuclear cross-sections with respect to the deuterium cross-sections (the EMC effect) for the targets 9Be, 12C, 10B, and 11B. The nuclear dependence of the inclusive inelastic electron scattering cross-section has been measured for the first time in 10B and 11B.

Karki, Abishek↗

Optimization of a phase-space beam position and size monitor for low-emittance light sources

The recently developed vertical phase-space beam position and size monitor (ps-BPM) system has proven to be able to measure the electron-source position, angle, size and divergence simultaneously in the vertical plane at a single location of a beamline. The optimization of the ps-BPM system is performed by ray-tracing simulation to maximize the instrument sensitivity and resolution. The contribution of each element is studied, including the monochromator, the K -edge filter, the detector and the source-to-detector distance. An optimized system is proposed for diffraction-limited storage rings, such as the Advanced Photon Source Upgrade project. The simulation results show that the ps-BPM system can precisely monitor the source position and angle at high speed. Precise measurements of the source size and divergence will require adequate resolution with relatively longer integration time.

47 OTHER INSTRUMENTATION↗