At least 523 records · Page 29

Pressure Barrier Applicability to Polymer Flood Design

Effective oil displacement from a reservoir requires adequate and properly directed pressure gradients in areas of high oil saturation. If the polymer bank is too large or too viscous during a polymer flood, the pressure drop from the injection well to the polymer front may act as a pressure barrier by usurping most of the downstream driving force for oil displacement. Polymer injection pressures must be limited. The maximum allowable injection pressure is commonly constrained by caprock integrity, injection equipment, and/or regulations, even though fractures can be beneficial to polymer injectivity (and even sweep efficiency in some cases). This paper examines when the pressure-barrier concept limits the size and viscosity of the polymer bank during a polymer flood. Both analytical and numerical methods are used to address this issue. We examine the relevance of the pressure barrier concept for a wide variety of circumstances, including oil viscosities ranging from 10-cp (like at Daqing, China) to 1650-cp (like at Pelican Lake, Alberta), vertical wells (like at Tambaredjo, Suriname) versus horizontal wells (like at Milne Point, Alaska), single versus multiple layered reservoirs, permeability contrast, and with versus with crossflow between layers. We also examine the relation between the pressure-barrier concept and fractures and fracture extension during polymer injection. We demonstrate that in reservoirs with single layers, the pressure-barrier concept only limits the optimum viscosity of the injected polymer if the mobility of the polymer bank is less than the mobility of the displaced oil bank. The same is true for multi-zoned reservoirs with no crossflow between layers. Thus, for these cases, the optimum polymer viscosity is likely to be dictated by the mobility of the oil bank, unless other factors (like fracture extension) intervene. For multi-zoned reservoirs with free crossflow between layers, the situation is different. A compromise must be reached between injected polymer viscosity and the efficiency of oil recovery. The relevance of our findings is applied to operations for several existing polymer floods. This work is particularly relevant to viscous-oil reservoirs (like Pelican Lake and others) where the injected polymer viscosities are substantially lower than the oil viscosity

Wang, Dongmei↗

Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger

Design, fabrication, and experimental characterization of the performance of a molten salt (MS)-to-supercritical carbon dioxide (sCO 2 ) heat exchanger (HE) for concentrating solar power (CSP) applications using laser powder bed fusion (LPBF) additive manufacturing (AM) of nickel-based superalloys is presented in this report. The hypothesis is that such additively manufactured HEs will result in a monolithic, compact, low-pressure drop HE that is durable under cyclic operation at high temperature and high pressure in a corrosive salt environment. Two nickel-based superalloys were considered in the project- Haynes 230 (H230) and Haynes 282 (H282). Process windows for LPBF AM were established to provide dense low porosity parts for both alloys. Creep tests results on heat treated AM H230 and H282 samples showed that the AM fabricated specimens were as robust as the wrought specimens and showed no deficit in creep strength at high temperatures. Haynes 282 was down selected for the HE fabrication based on better dimensional tolerance, better corrosion resistance to chloride salt, and higher creep strength.

14 SOLAR ENERGY↗

Transport of liquid state nitrogen through long length service lines during thermal/vacuum testing

Physical and analytical aspects associated with the transport are presented. Included is a definition of the problems and difficulties imposed by the servicing of a typical solid cryogen system, as well as a discussion of the transport requirements and of the rationale which governed their solution. A successful detailed transport configuration is defined, and the application of established mathematics to the design approach is demonstrated. The significance of head pressure, pressure drop, line friction, heat leak, Reynolds number, and the fundamental equilibrium demands of pressure and temperature were examined as they relate to the achievement of liquid state flow. Performance predictions were made for the transport system, and several analytical quantities are tabulated. These data are analyzed and compared with measured and calculated results obtained while actually servicing a solid cryogen system during thermal/vacuum testing.

Florio, F. A.↗

Experimental evaluation of the Skylab orbital workshop ventilation system concept

Extensive testing was conducted to evaluate the Orbital Workshop ventilation concept. Component tests were utilized to determine the relationship between operating characteristics at 1 and 0.34 atm. System tests were conducted at 1 atm within the Orbital Workshop full-scale mockup to assess delivered volumetric flow rate and compartment air velocities. Component tests with the Anemostat circular diffusers (plenum- and duct-mounted) demonstrated that the diffuser produced essentially equivalent airflow patterns and velocities in 1- and 0.34-atm environments. The tests also showed that the pressure drop across the diffuser could be scaled from 1 to 0.34 atm using the atmosphere pressure ratio. Fan tests indicated that the performance of a multiple, parallel-mounted fan cluster could be predicted by summing the single-fan flow rates at a given delta P.

Allums, S. L.↗

Charcoal/Nitrogen Adsorption Cryocooler

Refrigerator with no wear-related moving parts produces 0.5 W of cooling at 118 K. When fully developed, refrigerator needs no electrical power, and life expectancy of more than 10 yr, operates unattended to cool sensitive infrared detectors for long periods. Only moving parts in adsorption cryocooler are check valves. As charcoal is cooled in canister, gas pressure drops, allowing inlet check valve to open and admit more nitrogen. When canister is heated, pressure rises, closing inlet valve and eventually opening outlet valve.

Bard, Steven↗

Simulation of Unique Pressure Changing Steps and Situations in Psa Processes

A more rigorous cyclic adsorption process simulator is being developed for use in the development and understanding of new and existing PSA processes. Unique features of this new version of the simulator that Ritter and co-workers have been developing for the past decade or so include: multiple absorbent layers in each bed, pressure drop in the column, valves for entering and exiting flows and predicting real-time pressurization and depressurization rates, ability to account for choked flow conditions, ability to pressurize and depressurize simultaneously from both ends of the columns, ability to equalize between multiple pairs of columns, ability to equalize simultaneously from both ends of pairs of columns, and ability to handle very large pressure ratios and hence velocities associated with deep vacuum systems. These changes to the simulator now provide for unique opportunities to study the effects of novel pressure changing steps and extreme process conditions on the performance of virtually any commercial or developmental PSA process. This presentation will provide an overview of the cyclic adsorption process simulator equations and algorithms used in the new adaptation. It will focus primarily on the novel pressure changing steps and their effects on the performance of a PSA system that epitomizes the extremes of PSA process design and operation. This PSA process is a sorbent-based atmosphere revitalization (SBAR) system that NASA is developing for new manned exploration vehicles. This SBAR system consists of a 2-bed 3-step 3-layer system that operates between atmospheric pressure and the vacuum of space, evacuates from both ends of the column simultaneously, experiences choked flow conditions during pressure changing steps, and experiences a continuously changing feed composition, as it removes metabolic CO2 and H20 from a closed and fixed volume, i.e., the spacecraft cabin. Important process performance indicators of this SBAR system are size, and the corresponding CO2 and H20 removal efficiencies, and N2 and O2 loss rates. Results of the fundamental behavior of this PSA process during extreme operating conditions will be presented and discussed.

Ebner, Armin D.↗

Surge Pressure Mitigation in the Global Precipitation Measurement Mission Core Propulsion System

The Global Precipitation Measurement (GPM) mission is an international partnership between NASA and JAXA whose Core spacecraft performs cutting-edge measurements of rainfall and snowfall worldwide and unifies data gathered by a network of precipitation measurement satellites. The Core spacecraft's propulsion system is a blowdown monopropellant system with an initial hydrazine load of 545 kg in a single composite overwrapped propellant tank. At launch, the propulsion system contained propellant in the tank and manifold tubes upstream of the latch valves, with low-pressure helium gas in the manifold tubes downstream of the latch valves. The system had a relatively high beginning-of- life pressure and long downstream manifold lines; these factors created conditions that were conducive to high surge pressures. This paper discusses the GPM project's approach to surge mitigation in the propulsion system design. The paper describes the surge testing program and results, with discussions of specific difficulties encountered. Based on the results of surge testing and pressure drop analyses, a unique configuration of cavitating venturis was chosen to mitigate surge while minimizing pressure losses during thruster maneuvers. This paper concludes with a discussion of overall lessons learned with surge pressure testing for NASA Goddard spacecraft programs.

Pressure↗

Design and fabrication of brayton cycle solar heat receiver

A detail design and fabrication of a solar heat receiver using lithium fluoride as the heat storage material was completed. A gas flow analysis was performed to achieve uniform flow distribution within overall pressure drop limitations. Structural analyses and allowable design criteria were developed for anticipated environments such as launch, pressure containment, and thermal cycling. A complete heat receiver assembly was fabricated almost entirely from the refractory alloy, niobium-1% zirconium.

Mendelson, I.↗

Ultrafiltration by a compacted clay membrane. I - Oxygen and hydrogen isotopic fractionation. II - Sodium ion exclusion at various ionic strengths.

Laboratory experiments were carried out to determine the magnitude of the isotopic fractionation of distilled water and of 0.01N NaCl forced to flow at ambient temperature under a hydraulic pressure drop of 100 bars across a montmorillonite disk compacted to a porosity of 35% by a pressure of 330 bars. The ultrafiltrates in both experiments were depleted in D by 2.5% and in O-18 by 0.8% relative to the residual solution. No additional isotopic fractionation due to a salt-filtering mechanism was observed at NaCl concentrations up to 0.01N. Adsorption is most likely the principal mechanism which produces isotopic fractionation, but molecular diffusion may play a minor role. The results suggest that oxygen and hydrogen isotopic fractionation of ground water during passage through compacted clayey sediments should be a common occurrence, in accord with published interpretations of isotopic data from the Illinois and Alberta basins. It is shown how it is possible to proceed from the ion exchange capacity of clay minerals and, by means of the Donnan membrane equilibrium concept and the Teorell-Meyer-Siever theory, develop a theory to explain why and to what extent ultrafiltration occurs when solutions of known concentration are forced to flow through a clay membrane.

Coplen, T. B.↗

Analyzing Thermal Conditions In Rocket Engines

Computer code, RTE, developed to perform three-dimensional thermal analyses of rocket thrust chambers. Calculates rate of heat transfer from combustion gases to coolant, coolant-temperature rise and pressure drop, and temperature profiles within cooling-jacket wall. Also calculates combustion-gas wall static pressure, temperature and enthalpy, as well as coolant pressure, temperature, and mach number for all stations. Program used for any propellant combination and most coolants commonly used in rockets. Code used for both regeneratively and radiatively cooled engines. However, in case of regeneratively cooled engines, applicability limited to engines featuring single-pass cooling and rectangular cooling channels.

Naraghi, M. H. N.↗

Incompressible flow in stepped labyrinth seals

A steped labyrinth seal was experimentally investigated to determine the effects of pressure ratio, shaft speed, number of teeth, and tooth/step location upon the leakage through the seal for incompressible flow. The dependence of the flow coefficient upon the number of throttles and pressure ratio are similar to those for straight-through labyrinth seals. It can be noted that the axial location of the throttle with respect to the step had a special effect upon the flow coefficient. That is, the dependency of the flow coefficient upon rotation rate and the number of throttles changes with axial location. It was found that the minimum flow coefficient was obtained when the seal teeth were centered on the step surface. Axial pressure distribution measurements show that when the teeth are centered on the step, the pressure drop from cavity to cavity is almost uniform. It is speculated that the obtaining of this uniform pressure gradient is the cause for the enhanced performance of the stepped labyrinth seal when operated in that configuration.

Morrison, G. L.↗

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗

Large Eddy Simulation of Externally Induced Ingress about an Axial Seal by Stator Vanes

Turbine inlet temperatures in advanced gas turbines could be as high as 2000 °C. To prevent ingress of this hot gas into the wheelspace between the stator and rotor disks, whose metals can only handle temperatures up to 850 °C, rim seals and sealing flows are used. This study examines the abilities of large eddy simulation (LES) based on the WALE subgrid model and Reynolds-averaged Navier–Stokes (RANS) based on the SST model in predicting ingress in a rotor–stator configuration with vanes but no blades, a configuration with experimental data for validation. Results were obtained for an operating condition, where the ratio of the external Reynolds number to the rotational Reynolds number is 0.538. At this operating condition, both LES and RANS were found to correctly predict the coefficient of pressure, C p , located downstream of the vanes and upstream of the seal, but only LES was able to correctly predict the sealing effectiveness. This shows C p by itself is inadequate in quantifying externally induced ingress. RANS was unable to predict the sealing effectiveness because it significantly under predicted the pressure drop in the hot gas path along the axial direction, especially about the seal region. This affected the pressure difference across the seal in the radial direction, which ultimately drives ingress.

42 ENGINEERING↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗

Hydraulic model of the proposed Water Recovery and Management system for Space Station Freedom

A model of the Water Recovery and Management (WRM) system utilizing SINDA '85/FLUINT to determine its hydraulic operation characteristics, and to verify the design flow and pressure drop parameters is presented. The FLUINT analysis package is employed in the model to determine the flow and pressure characteristics when each of the different loop components is operational and contributing to the overall flow pattern. The water is driven in each loop by storage tanks pressurized with cabin air, and is routed through the system to the desired destination.

Martin, Charles E.↗

Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system's liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems, but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.6 lb. The water side and gas side pressure drops were 0.8 psid and 0.5 inches of water, respectively. Performance of the heat exchanger at the nominal pressure of 4.1 psia was measured at 94%, while a gas inlet pressure of 25 psia resulted in an effectiveness of 84%. These results compared well with the model, which was scaled for the small size. Modeling of certain phenomena that affect performance, such as flow distribution in the headers was particularly difficult due to the small size of the heat exchanger. Data from the tests has confirmed the correction factors that were used in these parts of the model.

Jennings, Mallory↗

Prediction of performance of centrifugal pumps during starts under pressure

Method which calculates start-up characteristics of centrifugal pumps reveals a capacity to predict pressure drop characteristics of pumps with vaned diffusers. Calculations are based on pump geometry, design-point flow, speed, and pressure rise, and the pump characteristic within range of approximately ten percent of the design-point flow.

Rostafinski, W.↗