Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A Mechanistic Model of Early FcεRI Signaling: Lipid Rafts and the Question of Protection from Dephosphorylation

We present a model of the early events in mast cell signaling mediated by FceRI where the plasma membrane is composed of many small ordered lipid domains (rafts), surrounded by a non-order region of lipids consisting of the remaining plasma membrane. The model treats the rafts as transient structures that constantly form and breakup, but that maintain a fixed average number per cell. The rafts have a high propensity for harboring Lyn kinase, aggregated, but not unaggregated receptors, and the linker for the activation of T cells (LAT). Phosphatase activity in the rafts is substantially reduced compared to the nonraft region. We use the model to analyze published experiments on the rat basophilic leukemia (RBL)- 2H3 cell line that seem to contradict the notion that rafts offer protection. In these experiments IgE was cross-linked with a multivalent antigen and then excess monovalent hapten was added to break-up cross-links. The dephosphorylation of the unaggregated receptor (nonraft associated) and of LAT (raft associated) were then monitored in time and found to decay at similar rates, leading to the conclusion that rafts offer no protection from dephosphorylation. In the model, because the rafts are transient, a protein that is protected while in a raft will be subject to dephosphorylation when the raft breaks up and the protein finds itself in the nonraft region of the membrane. We show that the model is consistent with the receptor and LAT dephosphorylation experiments while still allowing rafts to enhance signaling by providing substantial protection from phosphatases.

59 BASIC BIOLOGICAL SCIENCES↗

A meta-analysis of the association between gender and protective behaviors in response to respiratory epidemics

Respiratory infectious disease epidemics and pandemics are recurring events that levy a high cost on individuals and society. The health-protective behavioral response of the public plays an important role in limiting respiratory infectious disease spread. Health-protective behaviors take several forms. Behaviors can be categorized as pharmaceutical (e.g., vaccination uptake, antiviral use) or non-pharmaceutical (e.g., hand washing, face mask use, avoidance of public transport). Due to the limitations of pharmaceutical interventions during respiratory epidemics and pandemics, public health campaigns aimed at limiting disease spread often emphasize both non-pharmaceutical and pharmaceutical behavioral interventions. Understanding the determinants of the public’s behavioral response is crucial for devising public health campaigns, providing information to parametrize mathematical models, and ultimately limiting disease spread. While other reviews have qualitatively analyzed the body of work on demographic determinants of health-protective behavior, this meta-analysis quantitatively combines the results from 85 publications to determine the global relationship between gender and health-protective behavioral response. The results show that women in the general population are about 50% more likely than men to adopt/practice non-pharmaceutical behaviors. Conversely, men in the general population are marginally (about 12%) more likely than women to adopt/practice pharmaceutical behaviors. It is possible that factors other than pharmaceutical/non-pharmaceutical status not included in this analysis act as moderators of this relationship. We find these results suggest an inherent difference in how men and women respond to epidemic and pandemic respiratory infectious diseases. In conclusion, this information can be used to target specific groups when developing non-pharmaceutical public health campaigns and to parameterize epidemic models incorporating demographic information.

60 APPLIED LIFE SCIENCES↗

Investigating the effectiveness of many-core network processors for high performance cyber protection systems. Part I, FY2011.

This report documents our first year efforts to address the use of many-core processors for high performance cyber protection. As the demands grow for higher bandwidth (beyond 1 Gbits/sec) on network connections, the need to provide faster and more efficient solution to cyber security grows. Fortunately, in recent years, the development of many-core network processors have seen increased interest. Prior working experiences with many-core processors have led us to investigate its effectiveness for cyber protection tools, with particular emphasis on high performance firewalls. Although advanced algorithms for smarter cyber protection of high-speed network traffic are being developed, these advanced analysis techniques require significantly more computational capabilities than static techniques. Moreover, many locations where cyber protections are deployed have limited power, space and cooling resources. This makes the use of traditionally large computing systems impractical for the front-end systems that process large network streams; hence, the drive for this study which could potentially yield a highly reconfigurable and rapidly scalable solution.

99 GENERAL AND MISCELLANEOUS↗

Solving the software protection problem with intrinsic personal physical unclonable functions.

Physical Unclonable Functions (PUFs) or Physical One Way Functions (P-OWFs) are physical systems whose responses to input stimuli (i.e., challenges) are easy to measure (within reasonable error bounds) but hard to clone. The unclonability property comes from the accepted hardness of replicating the multitude of characteristics introduced during the manufacturing process. This makes PUFs useful for solving problems such as device authentication, software protection, licensing, and certified execution. In this paper, we focus on the effectiveness of PUFs for software protection in offline settings. We first argue that traditional (black-box) PUFs are not useful for protecting software in settings where communication with a vendor's server or third party network device is infeasible or impossible. Instead, we argue that Intrinsic PUFs are needed to solve the above mentioned problems because they are intrinsically involved in processing the information that is to be protected. Finally, we describe how sources of randomness in any computing device can be used for creating intrinsic-personal-PUFs (IP-PUF) and present experimental results in using standard off-the-shelf computers as IP-PUFs.

99 GENERAL AND MISCELLANEOUS↗

Foundations for Protecting Renewable-Rich Distribution Systems.

High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid introduces new challenges to protection of such systems. This is because the existing protection systems are designed with two assumptions: 1) system is single-sourced, resulting in unidirectional fault current, and (2) fault currents are easily detectable due to much higher magnitudes compared to load currents. Due to the fact that most renewables interface with the grid though inverters, and inverters restrict their current output to levels close to the full load currents, both these assumptions are no longer valid - the system becomes multi-sourced, and overcurrent-based protection does not work. The primary scope of this study is to analyze the response of a grid-tied inverter to different faults in the grid, leading to new guidelines on protecting renewable-rich distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Inverter Based Resource Negative Sequence Current Injection on Transmission System Protection

This report documents the results of analysis performed to investigate the impact of inverter-based resource (IBR) response to unbalanced faults on transmission system protective relay dependability and security. Electromagnetic transient (EMT) simulations were performed to simulate IBR response to these faults using existing manufacturer-developed EMT models for four separate IBRs. The study team was composed of IBR manufacturers, relay manufacturers, transmission providers, reliability coordinators and industry consultants with experience in EMT simulation and system protection. The results indicate that under certain conditions, IBR response can result in protective relay misoperations if current protection practices, which were developed based on conventional power sources, are not adapted to the characteristics of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Electron Ion Collider Machine Protection System: On the necessity of the MPS abort system for Rapid Cycling Synchrotron

The Electron Ion Collider (EIC) accelerator complex includes multiple high-energy high-power accelerators [1]. Operation of such a complex is associated with numerous dangers of possible damage to the equipment. The EIC machine protection system (MPS) scope is to protect the components of each accelerator from damage by the beam. The EIC MPS design, commissioning and operation is closely interconnected with the protection of various accelerator subsystems, such as RF-system, cryogenics, vacuum system etc. Yet, the primary goal of the MPS is to protect the EIC accelerators from the possible damage caused by electron and proton beams.

43 PARTICLE ACCELERATORS↗

Electron Ion Collider Machine Protection System: Requirements for an Electron Storage Ring abort system

The Electron Ion Collider (EIC) accelerator complex includes multiple high-energy high-power accelerators [1]. Operation of such a complex is associated with numerous hazards and risks of possible damage to the equipment. The EIC machine protection system (MPS) scope is to protect the components of each accelerator from damage by the beam. The EIC MPS design, commissioning and operation is closely interconnected with the protection of various accelerator subsystems, such as RF-system, cryogenics, vacuum system etc. Yet, the primary goal of the MPS is to protect the EIC accelerators from the possible damage caused by electron and proton beams.

43 PARTICLE ACCELERATORS↗

Assessment of Pump Coastdown and Reactor Protection Scram Delays during Station Blackout Conditions

This report presents an assessment of the impact of pump coastdown time and reactor protection scram delays for the Versatile Test Reactor (VTR) during Protected Station Blackout (PSBO) conditions. While previous simulations for the VTR assumed centrifugal pumps in the primary system, the current pre-conceptual design uses electromagnetic (EM) pumps. Because there is uncertainty as to what the parameters of the EM pump design will be, this report focuses on the impact of the flow coastdown and the reactor protection scram delay, not on the needs of the pump design. PSBO transient simulations were performed using the SAS4A/SASSYS-1 fast reactor safety analysis code (version 5.2.3). The model used in the simulations is based on the FY18 SAS4A/SASSYS-1 model. A change to the model was made to replace the centrifugal pump model with an electromagnetic pump model with a motor generator as a coastdown mechanism. The results of the PSBO transient simulations were assessed against the criteria used in Reference 2 with an additional 50°C for conservatism to account for uncertainties. The results show that as the delay before scramming the rods increases, the moment of inertia of the coastdown mechanism must increase to satisfy the criteria. By increasing the moment of inertia to extend the flow coastdown, temperatures can be kept below the desired limits with reactor protection scram delays between 3 and 10 seconds.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

2022 Peer Review Project Summary: Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (mediumvoltage) level may also become common as a means for improving distribution reliability and resilience. The objective of this multiyear project is to increase the adoption of microgrids in secondary networks and meshed distribution systems by developing novel protection schemes that allow for safe reliable operation of DERs in secondary networks. We will address these challenges by working with the appropriate stakeholders of secondary network operators, protection vendors, and standards committee. The outcomes of this project include: a) development and/or demonstration of candidate methods for enabling protection of secondary networks containing high levels of DER; b) development of modeling and testing tools for protection systems designed for use with secondary networks including DERs; and c) development of new industrial partnerships to facilitate widespread results dissemination and eventual commercialization of results as appropriate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Protection and Control for High Penetration PV and Grid Resilience (Final Technical Report)

The report summarizes the work and accomplishments of DOE SETO funded project 36533 “Adaptive Protection and Control for High Penetration PV and Grid Resilience”. In order to increase the amount of distributed solar power that can be integrated into the distribution system, new methods for optimal adaptive protection, artificial intelligence or machine learning based protection, and time domain traveling wave protection are developed and demonstrated in hardware-in-the-loop and a field demonstration.

14 SOLAR ENERGY↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

Synchrophasor-Based Zonal Current Differential Protection for Secondary Low Voltage Networks

This report describes an approach to utilizing phasor measurement unit (PMU) data from multiple Intelligent Electronics Devices (IEDs) in a low-voltage network to produce a differential scheme for protecting the medium-voltage feeder and low-voltage network transformers. The proposed protection scheme is designed and prototyped on a real-time automation controller. Its performance is evaluated using real-time controller hardware-in-the-loop simulation. Lab testing results indicate that the proposed protection scheme allows significant distributed energy resources (DER) backfeed and enables selective and fast protection of medium voltage feeders.

42 ENGINEERING↗

Leveraging PMU for Protection and Control

This presentation discusses the application of synchronized measurement in transmission system protection. The proposed wide area system protection (WASP) scheme uses PMU data to perform zonal current differential protection for the whole transmission system with high IBR penetration. This novel protection concept uses synchronized measurement, which is one of the key tasks proposed in the award DE-EE0010655.

14 SOLAR ENERGY↗

Utility Experience with Inverter-Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. This report identifies various protection challenges due to IBRs that industry is facing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY24 – FY25 Efforts to Revive the ANS-54.8 Liquid Metal Fire Protection in LMR Plants Standard

The current multi-year effort seeks to utilize national laboratory support from Argonne to expedite revival of the ANS-54.8 standard titled “Liquid Metal Fire Protection in LMR Plants.” To achieve that objective, the following tasks were identified: Task 1 involves working directly with ANS to revive the ANS-54.8 Working Group. This was to be accomplished by completing necessary paperwork, submitting that paperwork to ANS for approval, enlisting potential working group members from industry, the NRC, national laboratories, and universities, and organizing and leading Working Group activities. The overall purpose of the Working Group is to develop an updated draft of ANS-54.8 for review and approval by ANS consensus committees, the ANS Standards Board, and certification from ANSI. Task 2 focuses on leveraging historical information and expertise at Argonne related to sodium fire protection systems and strategies. For more than a decade, Argonne has worked on both international and domestic projects related to sodium fire protection system development and evaluation. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group on important considerations that may be addressed in an updated draft of ANS-54.8. Task 3 focuses on leveraging Argonne experience in the development of and use of analysis methods and tools for the simulation of sodium fire scenarios and evaluation of the effectiveness of sodium fire protection systems and strategies. For more than a decade, Argonne has recovered, modified, and utilized several historical sodium fire analysis software tools. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group of best practices for sodium fire progression analysis that may be addressed in an updated draft of ANS-54.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final report and documentation for the security enabled programmable switch for protection of distributed internetworked computers LDRD.

An increasing number of corporate security policies make it desirable to push security closer to the desktop. It is not practical or feasible to place security and monitoring software on all computing devices (e.g. printers, personal digital assistants, copy machines, legacy hardware). We have begun to prototype a hardware and software architecture that will enforce security policies by pushing security functions closer to the end user, whether in the office or home, without interfering with users' desktop environments. We are developing a specialized programmable Ethernet network switch to achieve this. Embodied in this device is the ability to detect and mitigate network attacks that would otherwise disable or compromise the end user's computing nodes. We call this device a 'Secure Programmable Switch' (SPS). The SPS is designed with the ability to be securely reprogrammed in real time to counter rapidly evolving threats such as fast moving worms, etc. This ability to remotely update the functionality of the SPS protection device is cryptographically protected from subversion. With this concept, the user cannot turn off or fail to update virus scanning and personal firewall filtering in the SPS device as he/she could if implemented on the end host. The SPS concept also provides protection to simple/dumb devices such as printers, scanners, legacy hardware, etc. This report also describes the development of a cryptographically protected processor and its internal architecture in which the SPS device is implemented. This processor executes code correctly even if an adversary holds the processor. The processor guarantees both the integrity and the confidentiality of the code: the adversary cannot determine the sequence of instructions, nor can the adversary change the instruction sequence in a goal-oriented way.

99 GENERAL AND MISCELLANEOUS↗