Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Emergent Phenomena at Mott Interfaces – a Time- and Depth-Resolved Approach (Final Technical Report)

This is the final technical report for Award DE-SC0019297, Emergent Phenomena at Mott Interfaces – a Time- and Depth-Resolved Approach. This research program aimed to address the scientific questions related to the emergence and control of non-equilibrium electronic phases of matter in strongly correlated Mott oxides and their interfaces. We were focusing specifically on exploiting the interfaces in heterostructures and superlattices, containing Mott oxides CaMnO 3 and LaNiO 3 because in such systems, precise control of electronic and magnetic structure in the ground state can be achieved through dimensionality, heterostructuring, interface termination, and lattice strain. We utilized advanced x-ray spectroscopic and scattering techniques, to investigate these phenomena. Additionally, we used intense THz electric-field pulses generated by a femtosecond laser to directly modify the electronic structure and magnetic states of the ultrathin LaNiO 3 and CaMnO 3 layers in such heterostructures, with the objectives of disentangling, understanding, and harnessing control over the intricate competing interactions responsible for two-dimensional magnetism and metal-insulator transition at the interfaces.

36 MATERIALS SCIENCE↗

Investigation of SF6 Alternatives in Spark Gap Switches for GWP Reduction

This primary purpose of this project was to evaluate alternative gas mixtures to sulfur hexafluoride (SF6) developed for high voltage power delivery applications for use in high voltage spark gap switches. These SF6 alternatives lower global warming potential emissions and enable improvements to the pressure-voltage design space. A combined experimental, computational, and theoretical study was used to quantify the impact of persistent breakdown products on the breakdown distribution of SF6-replacement gas mixtures. Viable SF6 replacements suitable for use in spark gap switches were studied to enable performance and agility improvements for next-generation pulsed power research relevant to national security missions. Experimental campaign included establishing parameters of switch gases as function of concentration. Various concentrations and pressures were tested for trends in breakdown voltage, repeatability, and durability, and breakdown constituents. A zero-dimensional plasma global model was used to simulate the plasma arc decay and recombination process in spark-gap switches relevant to the Z machine. Finally, a complete and consistent set of electron-neutral collision cross-sections for the novel insulating gas C4F7N is reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗

Modeling Z-Pinches with the FLASH code

Z-Pinches occur when large amounts of current are run axially through a cylindrical conducting material, and the magnetic pressure causes said material to implode radially to its z-axis. They are useful concepts in a large range of physics and fields like fusion. Simulating these experiments are important to not only national laboratories but also in the private sector as well. FLASH is an open source MHD code that is a useful option for modeling these experiments. However, the physics needed to be verified against an actual theory. Using a paper written by S.A Slutz, Z-Pinch experiments were run with FLASH based on the parameters described in the paper, and then results were validated against the theory presented. This verified that FLASH, although has some discrepancies in the theory due to a difference in physics calculations, remains a powerful tool for modeling Z-Pinch experiments not only on the scale of the Z-Machine from Sandia National Laboratory, but also at the scale of the proposed Next Generation Pulsed Power (NGPP) machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sound Speeds of Solids from Ultrasonic Pulse Receiver Measurements

A common method of determining elastic material properties is utilizing an ultrasonic pulse receiver. This is a non-destructive test (NDT) causing no plastic deformation of the material. It requires a pulse generator, oscilloscope, and two transducers to measure the sound velocity of a material. Both longitudinal and shear sound velocities may be obtained by utilizing the appropriate transducer. Acoustic nondestructive testing methods are often used in manufacturing certification processes and for material defect detection in industry. These methods can also be utilized to directly measure the elastic moduli of a material without damaging the material. Overall, it is a low-cost experiment with minimal preparation, and is easy to use.

36 MATERIALS SCIENCE↗

Completely Positive Map for Noisy Driven Quantum Systems Derived by Keldysh Expansion

Accurate modeling of decoherence errors in quantum processors is crucial for analyzing and improving gate fidelities. To increase the accuracy beyond that of the Lindblad dynamical map, several generalizations have been proposed, and the exploration of simpler and more systematic frameworks is still ongoing. In this paper, we introduce a decoherence model based on the Keldysh formalism. This formalism allows us to include non-periodic drives and correlated quantum noise in our model. In addition to its wide range of applications, our method is also numerically simple, and yields a CPTP map. These features allow us to integrate the Keldysh map with quantum-optimal-control techniques. We demonstrate that this strategy generates pulses that mitigate correlated quantum noise in qubit state-transfer and gate operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extracting the Dynamic Magnetic Contrast in Time-Resolved X-Ray Transmission Microscopy

Using a time-resolved detection scheme in scanning transmission X-ray microscopy (STXM), we measured element resolved ferromagnetic resonance (FMR) at microwave frequencies up to 10 GHz and a spatial resolution down to 20 nm at two different synchrotrons. We present different methods to separate the contribution of the background from the dynamic magnetic contrast based on the X-ray magnetic circular dichroism (XMCD) effect. The relative phase between the GHz microwave excitation and the X-ray pulses generated by the synchrotron, as well as the opening angle of the precession at FMR can be quantified. A detailed analysis for homogeneous and inhomogeneous magnetic excitations demonstrates that the dynamic contrast indeed behaves as the usual XMCD effect. The dynamic magnetic contrast in time-resolved STXM has the potential be a powerful tool to study the linear and nonlinear, magnetic excitations in magnetic micro- and nano-structures with unique spatial-temporal resolution in combination with element selectivity.

36 MATERIALS SCIENCE↗

Pulse measurement apparatus and method

An embodiment of the invention is directed to a pulse measuring system that measures a characteristic of an input pulse under test, particularly the pulse shape of a single-shot, nano-second duration, high shape-contrast optical or electrical pulse. An exemplary system includes a multi-stage, passive pulse replicator, wherein each successive stage introduces a fixed time delay to the input pulse under test, a repetitively-gated electronic sampling apparatus that acquires the pulse train including an entire waveform of each replica pulse, a processor that temporally aligns the replicated pulses, and an averager that temporally averages the replicated pulses to generate the pulse shape of the pulse under test. An embodiment of the invention is directed to a method for measuring an optical or an electrical pulse shape. The method includes the steps of passively replicating the pulse under test with a known time delay, temporally stacking the pulses, and temporally averaging the stacked pulses. An embodiment of the invention is directed to a method for increasing the dynamic range of a pulse measurement by a repetitively-gated electronic sampling device having a rated dynamic range capability, beyond the rated dynamic range of the sampling device; e.g., enhancing the dynamic range of an oscilloscope. The embodied technique can improve the SNR from about 300:1 to 1000:1. A dynamic range enhancement of four to seven bits may be achieved.

47 OTHER INSTRUMENTATION↗

Operational experiences of the spallation neutron source superconducting linac and power ramp-up

The spallation neutron source (SNS) is a second generation pulsed neutron source and designed to provide a 1-GeV, 1.44-MW proton beam to a mercury target for neutron production. Since the commissioning of the accelerator complex in 2006, the SNS has started its operation for neutron production and beam power ramp-up has been in progress toward the design goal. All subsystems of the SNS were designed and developed for substantial improvements compared to existing accelerators because the design beam power is almost an order of magnitude higher compared to existing neutron facilities and the achievable neutron scattering performance will exceed present sources by more than a factor of 20 to 100. In this paper, the operational experiences with the SNS Superconducting Linac (SCL), Power Ramp-up Plan to reach the design goal and the Power Upgrade Plan (PUP) will be presented including machine, subsystem and beam related issues.

43 PARTICLE ACCELERATORS↗

A Drive Laser for Multi-Bunch Photoinjector Operation

Numerous electron beam applications would benefit from increased average current without sacrificing beam brightness. Work is underway at LLNL to investigate the performance of X-band photoinjectors that would generate electron bunches at a rate matching the RF drive frequency, i.e. one bunch per RF cycle. A critical part of this effort involves development of photo-cathode drive laser technology. Here we present a new laser architecture that can generate pulse trains at repetition rates up to several GHz. This compact, fiber-based system is driven directly by the accelerator RF and so is inherently synchronized with the accelerating fields, and scales readily over a wide range of drive frequencies (L-band through X-band). The system will be required to produce 0.5 {mu}J, {approx}200 fs rise time, spatially and temporally shaped UV pulses designed to optimize the electron beam brightness. Presented is the current status of this system, producing 2 ps pulses from a continuous-wave source.

42 ENGINEERING↗

Real-time Studies of Shocked Polycrystalline Materials with Single-Pulse X-ray Diffraction

Characteristic K-α x-rays used for single-pulse XRD are conventionally produced by a 37-stage high-voltage Marx pulse generator coupled to a vacuum needle-and-washer x-ray diode via coaxial transmission line. A large field-of-view x-ray image plate detection system typically enables observation of several Debye-Scherrer rings. Recently, we have developed a fiber-optic reducer, coupled to a CCD camera, to obtain low-noise, large field-of-view images. The direct beam spot is produced by bremsstrahlung radiation attenuated by a twomillimeter tungsten beam stop. Determination of the direct beam position is necessary to perform the ring integration.

36 MATERIALS SCIENCE↗

Plasma discharge self-cleaning filtration system

The present invention is directed to a novel method for cleaning a filter surface using a plasma discharge self-cleaning filtration system. The method involves utilizing plasma discharges to induce short electric pulses of nanoseconds duration at high voltages. These electrical pulses generate strong Shockwaves that disintegrate and dislodge particulate matter located on the surface of the filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

As a pulsed neutron source, a Dense Plasma Focus (DPF) has a wide range of applications including active interrogation of special nuclear materials. In order to measure the material properties of interest with high accuracy and low uncertainties, the properties of the neutron pulse generated by the DPF must be well characterized including the peak neutron energy and the neutron energy density. These quantities can be inferred by measuring neutron counts on a collection of radiation detectors at difference distances using time-of-flight (TOF) principles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Memory cell comprising coupled Josephson junctions

Methods and apparatus are disclosed for operating a memory cell formed from the plurality of coupled Josephson junctions. The memory cell is configured such that applying an electrical signal to the junctions can cause at least one, but not all, of the junctions to change their respective phase states. Subsequent writes to the memory cell using substantially the same electrical pulse do not change the phase state of the plurality of junctions. The memory cell can be ready by providing another electrical pulse to one of the junctions and receiving an output electrical pulse generated in response by a different Josephson junction of the memory cell. A set of phase states are selected to represent the logic values that are stable across anticipated operating conditions for the memory cell. Methods of selecting electrical parameters and manufacturing memory cells are further disclosed.

97 MATHEMATICS AND COMPUTING↗

High speed driver for particle beam deflector

A system, method and apparatus for providing pulsed power comprises a trigger comprising a pulse generator and a photonic transmitter and a multi-stage switch comprising a gate driver circuit, the gate driver circuit further comprising a plurality of transistors connected in series and a plurality of driver stages wherein each of the transistors is turned on and off simultaneously by the plurality of driver stages.

Frolov, Daniil↗

Rational nano-coulomb ionization

An ion pulse generator includes a triboelectric generator, an ion emitter and a conductive surface. The triboelectric generator includes a first electrode, a spaced apart second electrode and a first triboelectric layer. The triboelectric generator generates a predetermined amount of charge as a result of relative movement of the first triboelectric layer. The ion emitter is electrically coupled to the first electrode. The conductive surface is electrically coupled to the second electrode and is spaced apart from the ion emitter at a predetermined distance. Generation of the predetermined amount of charge causes formation of ions between the ion emitter and the conductive surface.

Li, Anyin↗

Total internal reflection enabled wide-field Coherent anti-Stokes Raman scattering microscopy

A system is provided. The system has a femtosecond oscillator to generate pulses used for pump and probe beams. A photonic crystal fiber is disposed in a path of the probe beam and produces pulses for a chirped probe beam. A high NA objective receives the pump and the chirped probe beam, redirects the received beams through a dielectric substrate towards an interface between a sample and the dielectric substrate to cause total internal reflection (TIR) at the sample-substrate interface, and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. The dielectric substrate is transparent to the responsive light, the pump and the chirped probe beam. An image is produced having a specific image size using the received backward-propagating beam.

Doughty, Benjamin L.↗

Multimodal nonlinear optical imaging via evanescent wave excitation

A system for multimodal nonlinear optical imaging is provided. Each mode uses a high NA objective to cause total internal reflection excitation at a sample-substrate interface. The system has a femtosecond oscillator to generate pulses used for two beams. The objective receives at least one beam, redirects the received at least one beam through a dielectric substrate to cause the TIR and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. Different modes or combinations of the distinct modalities may be selected to access complementary chemical and structural information for various chemical species near the sample-substrate interface. Each mode may have mode-specific control such as selective beam blocking, power ratios and filtering.

Doughty, Benjamin L.↗